Publication


Featured researches published by Levi J. Hargrove.


IEEE Transactions on Biomedical Engineering | 2007

A Comparison of Surface and Intramuscular Myoelectric Signal Classification

Levi J. Hargrove; Kevin B. Englehart; Bernard Hudgins

The surface myoelectric signal (MES) has been used as an input to controllers for powered prostheses for many years. As a result of recent technological advances it is reasonable to assume that there will soon be implantable myoelectric sensors which will enable the internal MES to be used as input to these controllers. An internal MES measurement should have less muscular crosstalk allowing for more independent control sites. However, it remains unclear if this benefit outweighs the loss of the more global information contained in the surface MES. This paper compares the classification accuracy of six pattern recognition-based myoelectric controllers which use multi-channel surface MES as inputs to the same controllers which use multi-channel intramuscular MES as inputs. An experiment was designed during which surface and intramuscular MES were collected simultaneously for 10 different classes of isometric contraction. There was no significant difference in classification accuracy as a result of using the intramuscular MES measurement technique when compared to the surface MES measurement technique. Impressive classification accuracy (97%) could be achieved by optimally selecting only three channels of surface MES


IEEE Transactions on Biomedical Engineering | 2011

Continuous Locomotion-Mode Identification for Prosthetic Legs Based on Neuromuscular–Mechanical Fusion

He Huang; Fan Zhang; Levi J. Hargrove; Zhi Dou; Daniel R. Rogers; Kevin B. Englehart

In this study, we developed an algorithm based on neuromuscular-mechanical fusion to continuously recognize a variety of locomotion modes performed by patients with transfemoral (TF) amputations. Electromyographic (EMG) signals recorded from gluteal and residual thigh muscles and ground reaction forces/moments measured from the prosthetic pylon were used as inputs to a phase-dependent pattern classifier for continuous locomotion-mode identification. The algorithm was evaluated using data collected from five patients with TF amputations. The results showed that neuromuscular-mechanical fusion outperformed methods that used only EMG signals or mechanical information. For continuous performance of one walking mode (i.e., static state), the interface based on neuromuscular-mechanical fusion and a support vector machine (SVM) algorithm produced 99% or higher accuracy in the stance phase and 95% accuracy in the swing phase for locomotion-mode recognition. During mode transitions, the fusion-based SVM method correctly recognized all transitions with a sufficient predication time. These promising results demonstrate the potential of the continuous locomotion-mode classifier based on neuromuscular-mechanical fusion for neural control of prosthetic legs.


IEEE Transactions on Neural Systems and Rehabilitation Engineering | 2011

Determining the Optimal Window Length for Pattern Recognition-Based Myoelectric Control: Balancing the Competing Effects of Classification Error and Controller Delay

Lauren H. Smith; Levi J. Hargrove; Blair A. Lock; Todd A. Kuiken

Pattern recognition-based control of myoelectric prostheses has shown great promise in research environments, but has not been optimized for use in a clinical setting. To explore the relationship between classification error, controller delay, and real-time controllability, 13 able-bodied subjects were trained to operate a virtual upper-limb prosthesis using pattern recognition of electromyogram (EMG) signals. Classification error and controller delay were varied by training different classifiers with a variety of analysis window lengths ranging from 50 to 550 ms and either two or four EMG input channels. Offline analysis showed that classification error decreased with longer window lengths ( p <; 0.01). Real-time controllability was evaluated with the target achievement control (TAC) test, which prompted users to maneuver the virtual prosthesis into various target postures. The results indicated that user performance improved with lower classification error (p <; 0.01 ) and was reduced with longer controller delay ( p <; 0.01), as determined by the window length. Therefore, both of these effects should be considered when choosing a window length; it may be beneficial to increase the window length if this results in a reduced classification error, despite the corresponding increase in controller delay. For the system employed in this study, the optimal window length was found to be between 150 and 250 ms , which is within acceptable controller delays for conventional multistate amplitude controllers.


Biomedical Signal Processing and Control | 2008

A training strategy to reduce classification degradation due to electrode displacements in pattern recognition based myoelectric control

Levi J. Hargrove; Kevin B. Englehart; Bernard Hudgins

Abstract Pattern recognition based myoelectric control systems rely on detecting repeatable patterns at given electrode locations. This work describes an experiment to determine the effect of electrode displacements on pattern classification accuracy, and a classifier training strategy to accommodate this degradation. The results show that electrode displacements adversely affect classification accuracy, but training the system to recognize plausible displacement locations mitigates the effect. Furthermore, a combination of time-domain and autoregressive features appears to yield the best classification accuracy and is least affected by electrode displacements.


IEEE Transactions on Neural Systems and Rehabilitation Engineering | 2010

Multiple Binary Classifications via Linear Discriminant Analysis for Improved Controllability of a Powered Prosthesis

Levi J. Hargrove; Erik Scheme; Kevin B. Englehart; Bernard Hudgins

This paper describes a novel pattern recognition based myoelectric control system that uses parallel binary classification and class specific thresholds. The system was designed with an intuitive configuration interface, similar to existing conventional myoelectric control systems. The system was assessed quantitatively with a classification error metric and functionally with a clothespin test implemented in a virtual environment. For each case, the proposed system was compared to a state-of-the-art pattern recognition system based on linear discriminant analysis and a conventional myoelectric control scheme with mode switching. These assessments showed that the proposed control system had a higher classification error (p < 0.001) but yielded a more controllable myoelectric control system (p < 0.001) as measured through a clothespin usability test implemented in a virtual environment. Furthermore, the system was computationally simple and applicable for real-time embedded implementation. This work provides the basis for a clinically viable pattern recognition based myoelectric control system which is robust, easily configured, and highly usable.


IEEE Transactions on Biomedical Engineering | 2009

Principal Components Analysis Preprocessing for Improved Classification Accuracies in Pattern-Recognition-Based Myoelectric Control

Levi J. Hargrove; Guanglin Li; Kevin B. Englehart; Bernard Hudgins

Information extracted from multiple channels of the surface myoelectric signal (MES) recording sites can be used as inputs to control systems for powered upper limb prostheses. For small, closely spaced muscles, such as the muscles in the forearm, the detected MES often contains contributions from more than one muscle, the contribution from each specific muscle being modified by the dispersive propagation through the volume conductor between the muscle and the detection points. In this paper, the measured raw MES signals are rotated by class-specific principal component matrices to spatially decorrelate the measured data prior to feature extraction. This ldquotunesrdquo the data to allow a pattern recognition classifier to better discriminate the test motions. This processing technique was used to significantly (p<0.01) reduce pattern recognition classification error for both intact limbed and transradial amputee subjects.


IEEE Transactions on Biomedical Engineering | 2013

Classification of Simultaneous Movements Using Surface EMG Pattern Recognition

Aaron J. Young; Lauren H. Smith; Elliott J. Rouse; Levi J. Hargrove

Advanced upper limb prostheses capable of actuating multiple degrees of freedom (DOFs) are now commercially available. Pattern recognition algorithms that use surface electromyography (EMG) signals show great promise as multi-DOF controllers. Unfortunately, current pattern recognition systems are limited to activate only one DOF at a time. This study introduces a novel classifier based on Bayesian theory to provide classification of simultaneous movements. This approach and two other classification strategies for simultaneous movements were evaluated using nonamputee and amputee subjects classifying up to three DOFs, where any two DOFs could be classified simultaneously. Similar results were found for nonamputee and amputee subjects. The new approach, based on a set of conditional parallel classifiers was the most promising with errors significantly less ( p <; 0.05) than a single linear discriminant analysis (LDA) classifier or a parallel approach. For three-DOF classification, the conditional parallel approach had error rates of 6.6% on discrete and 10.9% on combined motions, while the single LDA had error rates of 9.4% on discrete and 14.1% on combined motions. The low error rates demonstrated suggest than pattern recognition techniques on surface EMG can be extended to identify simultaneous movements, which could provide more life-like motions for amputees compared to exclusively classifying sequential movements.


IEEE Transactions on Biomedical Engineering | 2012

Improving Myoelectric Pattern Recognition Robustness to Electrode Shift by Changing Interelectrode Distance and Electrode Configuration

Aaron J. Young; Levi J. Hargrove; Todd A. Kuiken

Pattern recognition of myoelectric signals for prosthesis control has been extensively studied in research settings and is close to clinical implementation. These systems are capable of intuitively controlling the next generation of dexterous prosthetic hands. However, pattern recognition systems perform poorly in the presence of electrode shift, defined as movement of surface electrodes with respect to the underlying muscles. This paper focused on investigating the optimal interelectrode distance, channel configuration, and electromyography feature sets for myoelectric pattern recognition in the presence of electrode shift. Increasing interelectrode distance from 2 to 4 cm improved pattern recognition system performance in terms of classification error and controllability ( p <; 0.01). Additionally, for a constant number of channels, an electrode configuration that included electrodes oriented both longitudinally and perpendicularly with respect to muscle fibers improved robustness in the presence of electrode shift (p <; 0.05). We investigated the effect of the number of recording channels with and without electrode shift and found that four to six channels were sufficient for pattern recognition control. Finally, we investigated different feature sets for pattern recognition control using a linear discriminant analysis classifier and found that an autoregressive set significantly (p <; 0.01) reduced sensitivity to electrode shift compared to a traditional time-domain feature set.


The New England Journal of Medicine | 2013

Robotic leg control with EMG decoding in an amputee with nerve transfers

Levi J. Hargrove; Ann M. Simon; Aaron J. Young; Robert D. Lipschutz; Suzanne B. Finucane; Douglas G. Smith; Todd A. Kuiken

The clinical application of robotic technology to powered prosthetic knees and ankles is limited by the lack of a robust control strategy. We found that the use of electromyographic (EMG) signals from natively innervated and surgically reinnervated residual thigh muscles in a patient who had undergone knee amputation improved control of a robotic leg prosthesis. EMG signals were decoded with a pattern-recognition algorithm and combined with data from sensors on the prosthesis to interpret the patients intended movements. This provided robust and intuitive control of ambulation--with seamless transitions between walking on level ground, stairs, and ramps--and of the ability to reposition the leg while the patient was seated.


Journal of Rehabilitation Research and Development | 2011

Target Achievement Control Test: Evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses

Ann M. Simon; Levi J. Hargrove; Blair A. Lock; Todd A. Kuiken

Despite high classification accuracies (~95%) of myoelectric control systems based on pattern recognition, how well offline measures translate to real-time closed-loop control is unclear. Recently, a real-time virtual test analyzed how well subjects completed arm motions using a multiple-degree of freedom (DOF) classifier. Although this test provided real-time performance metrics, the required task was oversimplified: motion speeds were normalized and unintended movements were ignored. We included these considerations in a new, more challenging virtual test called the Target Achievement Control Test (TAC Test). Five subjects with transradial amputation attempted to move a virtual arm into a target posture using myoelectric pattern recognition, performing the test with various classifier (1- vs 3-DOF) and task complexities (one vs three required motions per posture). We found no significant difference in classification accuracy between the 1- and 3-DOF classifiers (97.2% +/- 2.0% and 94.1% +/- 3.1%, respectively; p = 0.14). Subjects completed 31% fewer trials in significantly more time using the 3-DOF classifier and took 3.6 +/- 0.8 times longer to reach a three-motion posture compared with a one-motion posture. These results highlight the need for closed-loop performance measures and demonstrate that the TAC Test is a useful and more challenging tool to test real-time pattern-recognition performance.

Collaboration


Dive into the Levi J. Hargrove's collaboration.

Top Co-Authors

Avatar

Todd A. Kuiken

Rehabilitation Institute of Chicago

View shared research outputs
Top Co-Authors

Avatar

Ann M. Simon

Rehabilitation Institute of Chicago

View shared research outputs
Top Co-Authors

Avatar

Aaron J. Young

Georgia Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Lauren H. Smith

Rehabilitation Institute of Chicago

View shared research outputs
Top Co-Authors

Avatar

Elliott J. Rouse

Rehabilitation Institute of Chicago

View shared research outputs
Top Co-Authors

Avatar

Kevin B. Englehart

University of New Brunswick

View shared research outputs
Top Co-Authors

Avatar

Tommaso Lenzi

Rehabilitation Institute of Chicago

View shared research outputs
Top Co-Authors

Avatar

Blair A. Lock

Rehabilitation Institute of Chicago

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge