Li-Guo Zhu
China Academy of Engineering Physics
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Li-Guo Zhu.
Optics Express | 2016
Sen-Cheng Zhong; Jun Li; Zhao-Hui Zhai; Li-Guo Zhu; Jiang Li; Ping-Wei Zhou; Jian-Heng Zhao; Zeren Li
We proposed a cylindrical lens telescope tilted pulse front pumping scheme for high energy terahertz pulse generation. The optimum pump laser spectral bandwidth and crystal cooling temperature for OR in LN crystal were researched systematically. Excitated by 800-nm laser, more than 0.19 mJ energy and 0.27% efficiency terahertz pulses generation was demonstrated with the optimum bandwidth pumping and 150 K cooling temperature for the first time.
Applied Physics Letters | 2015
Yang Xiao; Zhao-Hui Zhai; Qiwu Shi; Li-Guo Zhu; Jun Li; Wanxia Huang; Fang Yue; Yanyan Hu; Qi-Xian Peng; Zeren Li
The ultrafast terahertz (THz) modulation characteristic during photo-induced insulator-to-metal transition (IMT) of undoped and tungsten (W)-doped VO2 film was investigated at picoseconds time scale using time-resolved THz spectroscopy. W-doping slows down the photo-induced IMT dynamic processes (both the fast non-thermal process and the slow metallic phase propagation process) in VO2 film and also reduces the pump fluence threshold of photo-induced IMT in VO2 film. Along with the observed broadening of phase transition temperature window of IMT in W-doped VO2, we conclude that W-doping prevents metallic phase domains from percolation. By further extracting carrier properties from photo-induced THz conductivity at several phase transition times, we found that the electron-electron correlation during IMT is enhanced in W-doped VO2.
Review of Scientific Instruments | 2009
Li-Guo Zhu; Wen-Cong Chen; Xi-Ming Zhu; Yi-Kang Pu; Zeren Li
A chromatic-free spatially resolved diagnostic system for microplasma measurement is proposed and demonstrated, which consists of an optical chromatic-free microscope mirror system, an electron multiplying charge coupled device (EMCCD), and bandpass filters. The diagnostic system free of chromatic aberrations with a spatial resolution of about 6 microm is achieved. The factors that limit the resolution of this diagnostic system have been analyzed, which are optical diffraction, the pixel size of the EMCCD, and the thickness of the microplasma. In this paper, the optimal condition for achieving a maximum resolution power has been analyzed. With this diagnostic system, we revealed the spatial nonuniformity of a microwave atmospheric-pressure argon microplasma. Furthermore, the spatial distribution of the time-averaged effective electron temperature has been estimated from the intensity distributions of 750.4 and 415.8 nm emissions.
AIP Advances | 2016
Liang-Hui Du; Jiang Li; Zhao-Hui Zhai; Kun Meng; Qiao Liu; Sen-Cheng Zhong; Ping-Wei Zhou; Li-Guo Zhu; Zeren Li; Qi-Xian Peng
Perfect absorbers with broadband absorption of terahertz (THz) radiation are promising for applications in imaging and detection to enhance the contrast and sensitivity, as well as to provide concealment. Different from previous two-dimensional structures, here we put forward a new type of THz absorber based on sawtooth-shape doped-silicon with near-unit absorption across a broad spectral range. Absorbance over 99% is observed numerically from 1.2 to 3 THz by optimizing the geometric parameters of the sawtooth structure. Our absorbers can operate over a wide range of incident angle and are polarization insensitive. The underlying mechanisms due to the combination of an air-cavity mode and mode-matching resonance on the air-sawtooth interface are analyzed in terms of the field patterns and electromagnetic power loss features.
International Seminar on Photonics, Optics, and Its Applications (ISPhOA 2014) | 2015
Zeren Li; Kun Meng; Tunan Chen; Tao Chen; Li-Guo Zhu; Qiao Liu; Zhao Li; Fei Li; Sen-Cheng Zhong; Hua Feng; Jianheng Zhao
The refractive indices, absorption coefficients and complex dielectric constants spectra of paraffin-embedded brain glioma and normal brain tissues have been measured by a terahertz time domain spectroscopy (THz-TDS) system in the range of 0.2 – 2.0 THz. The spectral differences between glioma and normal brain tissues were obtained. Our results indicate that, compared with normal tissue, glioma had higher refractive index, absorption coefficient, and dielectric constant. Based on these results, the suitable frequency components for different methods of glioma imaging (intensity imaging, coherent imaging and terahertz pulsed imaging) are analyzed.
Applied Physics Letters | 2009
Li-Guo Zhu; Zhi-Bo Zhang; Xi-Ming Zhu; Yi-Kang Pu; Zeren Li
The characteristics of the electron energy in a microwave atmospheric-pressure argon microplasma are investigated by a spatially resolved optical emission spectroscopy. By adding tiny amount of xenon ( 8.3 eV is quite different from that of the electrons with energy >11.5 eV. Spatial distribution of the population ratio between 4p and 5p levels of Ar atom is also determined. Furthermore, with a collisional-radiative model, it is found that the spatial variation of this population ratio is mainly attributed to the spatial nonuniformity of the effective electron temperature.
Applied Physics Letters | 2018
Hongfu Zhu; Liang-Hui Du; Jiang Li; Qiwu Shi; Bo Peng; Zeren Li; Wanxia Huang; Li-Guo Zhu
We present a terahertz (THz) amplitude modulation method with near perfect E-field amplitude modulation depths that is based on impedance matching in VO2 thin films during the thermally induced insulator-metal transition (IMT). It was observed that the impedance matching-induced THz amplitude modulation was sensitive to the resistance switching characteristics of the VO2 thin films. By designing the VO2 thin films to have four orders of magnitude of change in resistance during the IMT, we experimentally achieved an E-field amplitude modulation depth of 94.5% (intensity modulation depth of 99.7%) between the insulator phase of VO2 and the impedance matching state, and an E-field amplitude modulation depth of 97.6% (intensity modulation depth of 99.94%) between the impedance matching state and the metallic phase of VO2 at 0.5 THz. The experimental results were consistent with the results of simulations based on the transmission matrix model.
Review of Scientific Instruments | 2016
Zhao-Hui Zhai; Sen-Cheng Zhong; Jun Li; Li-Guo Zhu; Kun Meng; Jiang Li; Qiao Liu; Qixian Peng; Zeren Li; Jianheng Zhao
Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ∼400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.
International Conference on Optical Instruments and Technology 2017: THz/Infrared Technologies and Applications | 2018
Huachuan Huang; Qiao Liu; Li-Guo Zhu; Zeren Li; Liquan Dong; Xiang Zhang; Cunlin Zhang; Zhiming Huang
The hydration of biomolecules is closely related to the dynamic process of their functional expression, therefore, characterizing hydration phenomena is a subject of keen interest. However, direct measurements on the global hydration state of biomolecules couldn’t have been acquired using traditional techniques such as thermodynamics, ultrasound, microwave spectroscopy or viscosity, etc. In order to realize global hydration characterization of amino acid such as L-threonine, terahertz time-domain attenuated total reflectance spectroscopy (THz-TDS-ATR) was adopted in this paper. By measuring the complex permittivity of L-threonine solutions with various concentrations in the THz region, the hydration state and its concentration dependence were obtained, indicating that the number of hydrous water decreased with the increase of concentration. The hydration number was evaluated to be 17.8 when the molar concentration of L-threonine was 0.34 mol/L, and dropped to 13.2 when the molar concentration increased to 0.84 mol/L, when global hydration was taken into account. According to the proposed direct measurements, it is believed that the THz-TDS-ATR technique is a powerful tool for studying the picosecond molecular dynamics of amino acid solutions.
Biomedical Optics Express | 2018
Yi Zou; Qiao Liu; Xia Yang; Huachuan Huang; Jiang Li; Liang-Hui Du; Zeren Li; Jianheng Zhao; Li-Guo Zhu
We demonstrated that attenuated total reflectance terahertz time-domain spectroscopy (ATR THz-TDS) is able to monitor oxidative stress response of living human cells, which is proven in this work that it is an efficient non-invasive, label-free, real-time and in-situ monitoring of cell death. Furthermore, the dielectric constant and dielectric loss of cultured living human breast epithelial cells, and along with their evolution under oxidative stress response induced by high concentration of H2O2, were quantitatively determined in the work. Our observation and results were finally confirmed using standard fluorescence-labeled flow cytometry measurements and visible fluorescence imaging.