Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Li Hsiang Lin is active.

Publication


Featured researches published by Li Hsiang Lin.


Journal of Biomedical Materials Research Part A | 2015

Effects of antibacterial nanostructured composite films on vascular stents: Hemodynamic behaviors, microstructural characteristics, and biomechanical properties

Han Yi Cheng; Wen Tien Hsiao; Li Hsiang Lin; Ya Ju Hsu; Andi Wardihan Sinrang; Keng Liang Ou

The purpose of this research was to investigate stresses resulting from different thicknesses and compositions of hydrogenated Cu-incorporated diamond-like carbon (a-C:H/Cu) films at the interface between vascular stent and the artery using three-dimensional reversed finite element models (FEMs). Blood flow velocity variation in vessels with plaques was examined by angiography, and the a-C:H/Cu films were characterized by transmission electron microscopy to analyze surface morphology. FEMs were constructed using a computer-aided reverse design system, and the effects of antibacterial nanostructured composite films in the stress field were investigated. The maximum stress in the vascular stent occurred at the intersections of net-like structures. Data analysis indicated that the stress decreased by 15% in vascular stents with antibacterial nanostructured composite films compared to the control group, and the stress decreased with increasing film thickness. The present results confirmed that antibacterial nanostructured composite films improve the biomechanical properties of vascular stents and release abnormal stress to prevent restenosis. The results of the present study offer the clinical benefit of inducing superior biomechanical behavior in vascular stents.


Implant Dentistry | 2014

Follow-up Study of Dental Implants With Bioactive Oxide Films on Bone Tissue Healing and Osseointegration: Clinical Radiography and Bone Quality Analysis

Hsi Jen Chiang; Han Yi Cheng; Keng Liang Ou; Andi Wardihan Sinrang; Mao Suan Huang; Li Hsiang Lin

Objective:The purpose of this study was to investigate osseointegration and bone stress resulted during the first 3 months after the installation of functional implants modified with bioactive oxide. Methods:Several studies have investigated finite element models for dental implants; however, only a few have examined a model for the implants during different stages of osseointegration. In this study, mandible models were reconstructed using computer tomographic data, and bone qualities and stress distributions were investigated as well. Results:Bone quality increased rapidly within the 3-month bone healing time. Data analysis indicated that the bone stresses increased with the progress of osseointegration, and the maximum stresses were obtained at the position around the first screw. Conclusion:The results confirmed that functional films could improve the biomechanical properties of the implants and promote the initial bone stability. Furthermore, potential clinical benefit can be obtained due to the inducing superior biomechanical behavior in dental implants.


Journal of Biomedical Materials Research Part B | 2016

Research of electrosurgical unit with novel antiadhesion composite thin film for tumor ablation: Microstructural characteristics, thermal conduction properties, and biological behaviors

Yun-Dun Shen; Li Hsiang Lin; Hsi Jen Chiang; Keng Liang Ou; Han Yi Cheng

The objective of this study was to use surface functionalization to evaluate the antiadhesion property and thermal injury effects on the liver when using a novel electrosurgical unit with nanostructured-doped diamond-like carbon (DLC-Cu) thin films for tumor ablations. The physical and chemical properties of DLC-Cu thin films were characterized by contact angle goniometer, scanning electron microscope, and transmission electron microscope. Three-dimensional (3D) hepatic models were reconstructed using magnetic resonance imaging to simulate a clinical electrosurgical operation. The results indicated a significant increase of the contact angle on the nanostructured DLC-Cu thin films, and the antiadhesion properties were also observed in an animal model. Furthermore, the surgical temperature in the DLC-Cu electrosurgical unit was found to be significantly lower than the untreated unit when analyzed using 3D models and thermal images. In addition, DLC-Cu electrodes caused a relatively small injury area and lateral thermal effect. The results indicated that the nanostructured DLC-Cu thin film coating reduced excessive thermal injury and tissue adherence effect in the liver.


Journal of Nanomaterials | 2015

The application of minimally invasive devices with nanostructured surface functionalization: antisticking behavior on devices and liver tissue interface in rat

Li Hsiang Lin; Ya Ju Hsu; Hsi Jen Chiang; Han Yi Cheng; Che Shun Wang; Keng Liang Ou

This study investigated the thermal injury and adhesion property of a novel electrosurgery of liver using copper-doped diamondlike carbon (DLC-Cu) surface treatment. It is necessary to reduce the thermal damage of surrounding tissues for clinical electrosurgeries. The surface morphologies of stainless steel (SS) coated with DLC (DLC-Cu-SS) films were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Bionic liver models were reconstructed using magnetic resonance imaging (MRI) to simulate electrosurgery. Cell cytotoxicity assays showed that the DLC-Cu thin film was nontoxic. The temperature of tissue decreased significantly with use of the electrosurgical device with nanostructured DLC-Cu films and increased with increasing thickness of the films. Thermography revealed that the surgical temperature in the DLC-Cu-SS electrosurgical device was significantly lower than that in the untreated device in the animal model. Moreover, compared to the SS electrosurgical device, the DLC-Cu-SS electrosurgical device caused a relatively small injury area and lateral thermal effect. The results indicate that the DLC-Cu-SS electrosurgical device decreases excessive thermal injury and ensures homogeneous temperature transformation in the tissues.


Journal of Nanomaterials | 2015

A potential solution to minimally invasive device for oral surgery: evaluation of surgical outcomes in rat

Keng Liang Ou; Li Hsiang Lin; Hsi Jen Chiang; Han Yi Cheng; Shyuan Yow Chen; Chiung Fang Huang

The objective of the present research was to investigate the thermal injury in the brain after minimally invasive electrosurgery using instruments with copper-doped diamond-like carbon (DLC-Cu) surface coating. The surface morphologies of DLC-Cu thin films were characterized using scanning electron microscopy and atomic force microscopy. Three-dimensional brain models were reconstructed using magnetic resonance imaging to simulate the electrosurgical operation. In adult rats, a monopolar electrosurgical instrument coated with the DLC-Cu thin film was used to generate lesions in the brain. Animals were sacrificed for evaluations on postoperative days 0, 2, 7, and 28. Data indicated that the temperature decreased significantly when minimally invasive electrosurgical instruments with nanostructure DLC-Cu thin films were used and continued to decrease with increasing film thickness. On the other hand, the DLC-Cu-treated device created a relatively small thermal injury area and lateral thermal effect in the brain tissues. These results indicated that the DLC-Cu thin film minimized excessive thermal injury and uniformly distributed the temperature in the brain. Taken together, our study results suggest that the DLC-Cu film on copper electrode substrates is an effective means for improving the performance of electrosurgical instruments.


Annals of Biomedical Engineering | 2015

Retraction Note to: Effect of Anti-Sticking Nanostructured Surface Coating on Minimally Invasive Electrosurgical Device in Brain

Han Yi Cheng; Keng Liang Ou; Hsi Jen Chiang; Li Hsiang Lin

The purpose of the present study was to examine the extent of thermal injury in the brain after the use of a minimally invasive electrosurgical device with a nanostructured copper-doped diamond-like carbon (DLC-Cu) surface coating. To effectively utilize an electrosurgical device in clinical surgery, it is important to decrease the thermal injury to the adjacent tissues. The surface characteristics and morphology of DLC-Cu thin film was evaluated using a contact angle goniometer, scanning electron microscopy, and atomic force microscopy. Three-dimensional biomedical brain models were reconstructed using magnetic resonance images to simulate the electrosurgical procedure. Results indicated that the temperature was reduced significantly when a minimally invasive electrosurgical device with a DLC-Cu thin film coating (DLC-Cu-SS) was used. Temperatures decreased with the use of devices with increasing film thickness. Thermographic data revealed that surgical temperatures in an animal model were significantly lower with the DLC-Cu-SS electrosurgical device compared to an untreated device. Furthermore, the DLC-Cu-SS device created a relatively small region of injury and lateral thermal range. As described above, the biomedical nanostructured film reduced excessive thermal injury with the use of a minimally invasive electrosurgical device in the brain.


Annals of Biomedical Engineering | 2015

Effect of Anti-Sticking Nanostructured Surface Coating on Minimally Invasive Electrosurgical Device in Brain.

Han Yi Cheng; Keng Liang Ou; Hsi Jen Chiang; Li Hsiang Lin

The purpose of the present study was to examine the extent of thermal injury in the brain after the use of a minimally invasive electrosurgical device with a nanostructured copper-doped diamond-like carbon (DLC-Cu) surface coating. To effectively utilize an electrosurgical device in clinical surgery, it is important to decrease the thermal injury to the adjacent tissues. The surface characteristics and morphology of DLC-Cu thin film was evaluated using a contact angle goniometer, scanning electron microscopy, and atomic force microscopy. Three-dimensional biomedical brain models were reconstructed using magnetic resonance images to simulate the electrosurgical procedure. Results indicated that the temperature was reduced significantly when a minimally invasive electrosurgical device with a DLC-Cu thin film coating (DLC-Cu-SS) was used. Temperatures decreased with the use of devices with increasing film thickness. Thermographic data revealed that surgical temperatures in an animal model were significantly lower with the DLC-Cu-SS electrosurgical device compared to an untreated device. Furthermore, the DLC-Cu-SS device created a relatively small region of injury and lateral thermal range. As described above, the biomedical nanostructured film reduced excessive thermal injury with the use of a minimally invasive electrosurgical device in the brain.


Journal of Alloys and Compounds | 2010

High-temperature microstructural characteristics of a novel biomedical titanium alloy

Ming Chih Chang; Chin Wan Luo; Mao Suan Huang; Keng Liang Ou; Li Hsiang Lin; Hsin Chung Cheng


Applied Surface Science | 2011

Research of microstructural characteristics on nanocrystalline diamond by microwave plasma CVD

Jing Ming Hung; Li Hsiang Lin; Yung Hsun Shih; Chung Ming Liu; Hsin Chung Cheng; Keng Liang Ou


Journal of Alloys and Compounds | 2015

A mechanistic study on the antibacterial behavior of silver doped bioceramic

Shih Fu Ou; Ren Jei Chung; Li Hsiang Lin; Yi Chen Chiang; Chiung Fang Huang; Keng Liang Ou

Collaboration


Dive into the Li Hsiang Lin's collaboration.

Top Co-Authors

Avatar

Keng Liang Ou

Taipei Medical University

View shared research outputs
Top Co-Authors

Avatar

Han Yi Cheng

Taipei Medical University

View shared research outputs
Top Co-Authors

Avatar

Hsi Jen Chiang

Taipei Medical University

View shared research outputs
Top Co-Authors

Avatar

Chiung Fang Huang

Taipei Medical University Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jing Ming Hung

Taipei Medical University

View shared research outputs
Top Co-Authors

Avatar

Mao Suan Huang

Taipei Medical University

View shared research outputs
Top Co-Authors

Avatar

Yung Hsun Shih

Taipei Medical University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Che Shun Wang

Taipei Medical University

View shared research outputs
Researchain Logo
Decentralizing Knowledge