Journal of Biomechanical Engineering-transactions of The Asme | 2005

3-D Numerical Simulation of Blood Flow Through Models of the Human Aorta

Liam Morris; Patrick Delassus; Anthony Callanan; Michael Walsh; F. Wallis; P. Grace; Timothy M. McGloughlin

A Spiral Computerized Tomography (CT) scan of the aorta were obtained from a single subject and three model variations were examined. Computational fluid dynamics modeling of all three models showed variations in the velocity contours along the aortic arch with differences in the boundary layer growth and recirculation regions. Further down-stream, all three models showed very similar velocity profiles during maximum velocity with differences occurring in the decelerating part of the pulse. Flow patterns obtained from transient 3-D computational fluid dynamics are influenced by different reconstruction methods and the pulsatility of the flow. Caution is required when analyzing models based on CT scans.


Journal of Biomechanical Engineering-transactions of The Asme | 2013

Variability of Computational Fluid Dynamics Solutions for Pressure and Flow in a Giant Aneurysm: The ASME 2012 Summer Bioengineering Conference CFD Challenge

David A. Steinman; Yiemeng Hoi; Paul Fahy; Liam Morris; Michael T. Walsh; Nicolas Aristokleous; Andreas S. Anayiotos; Yannis Papaharilaou; Amirhossein Arzani; Shawn C. Shadden; Philipp Berg; Gábor Janiga; Joris Bols; Patrick Segers; Neil W. Bressloff; Merih Cibis; Frank J. H. Gijsen; Salvatore Cito; Jordi Pallares; Leonard D. Browne; Jennifer A. Costelloe; Adrian G. Lynch; Joris Degroote; Jan Vierendeels; Wenyu Fu; Aike Qiao; Simona Hodis; David F. Kallmes; Hardeep S. Kalsi; Quan Long

Stimulated by a recent controversy regarding pressure drops predicted in a giant aneurysm with a proximal stenosis, the present study sought to assess variability in the prediction of pressures and flow by a wide variety of research groups. In phase I, lumen geometry, flow rates, and fluid properties were specified, leaving each research group to choose their solver, discretization, and solution strategies. Variability was assessed by having each group interpolate their results onto a standardized mesh and centerline. For phase II, a physical model of the geometry was constructed, from which pressure and flow rates were measured. Groups repeated their simulations using a geometry reconstructed from a micro-computed tomography (CT) scan of the physical model with the measured flow rates and fluid properties. Phase I results from 25 groups demonstrated remarkable consistency in the pressure patterns, with the majority predicting peak systolic pressure drops within 8% of each other. Aneurysm sac flow patterns were more variable with only a few groups reporting peak systolic flow instabilities owing to their use of high temporal resolutions. Variability for phase II was comparable, and the median predicted pressure drops were within a few millimeters of mercury of the measured values but only after accounting for submillimeter errors in the reconstruction of the life-sized flow model from micro-CT. In summary, pressure can be predicted with consistency by CFD across a wide range of solvers and solution strategies, but this may not hold true for specific flow patterns or derived quantities. Future challenges are needed and should focus on hemodynamic quantities thought to be of clinical interest.


Journal of Biomechanical Engineering-transactions of The Asme | 2008

3D Reconstruction and Manufacture of Real Abdominal Aortic Aneurysms: From CT Scan to Silicone Model

Barry J. Doyle; Liam Morris; Anthony Callanan; P. Kelly; David A. Vorp; Timothy M. McGloughlin

Abdominal aortic aneurysm (AAA) can be defined as a permanent and irreversible dilation of the infrarenal aorta. AAAs are often considered to be an aorta with a diameter 1.5 times the normal infrarenal aorta diameter. This paper describes a technique to manufacture realistic silicone AAA models for use with experimental studies. This paper is concerned with the reconstruction and manufacturing process of patient-specific AAAs. 3D reconstruction from computed tomography scan data allows the AAA to be created. Mould sets are then designed for these AAA models utilizing computer aided designcomputer aided manufacture techniques and combined with the injection-moulding method. Silicone rubber forms the basis of the resulting AAA model. Assessment of wall thickness and overall percentage difference from the final silicone model to that of the computer-generated model was performed. In these realistic AAA models, wall thickness was found to vary by an average of 9.21%. The percentage difference in wall thickness recorded can be attributed to the contraction of the casting wax and the expansion of the silicone during model manufacture. This method may be used in conjunction with wall stress studies using the photoelastic method or in fluid dynamic studies using a laser-Doppler anemometry. In conclusion, these patient-specific rubber AAA models can be used in experimental investigations, but should be assessed for wall thickness variability once manufactured.


Journal of Endovascular Therapy | 2008

Geometrical enhancements for abdominal aortic stent-grafts.

David S. Molony; Anthony Callanan; Liam Morris; Barry J. Doyle; Michael T. Walsh; Timothy M. McGloughlin

Purpose: To compare the function of 2 stent-graft designs for endovascular abdominal aortic aneurysm repair. Methods: Computational fluid dynamics was used to investigate the performance of a conventional stent-graft versus one with a novel tapered configuration (equal area ratios at the inlet and bifurcation). Idealized geometries (uniplanar) were formed first for both devices. To mimic the clinical setting with pulsatile blood flow, a realistic model (multiplanar) was created for the conventional stent-graft based on computed tomography scans from 3 patients with different aortic geometries. A similar model was created for the tapered stent-graft by mimicking the deployment of the conventional stent-graft through its centerline. Results: The tapered stent-graft model demonstrated reduced secondary flow vortices and wall shear stresses in the iliac limbs compared to the conventional graft in the idealized scenario. The drag forces in the idealized models were similar for both designs, though the tapered stent-graft showed a 4% reduction. Flow was split more evenly between the tapered stent-graft limbs in the realistic scenario. Conclusion: The novel tapered design reduced flow velocities and secondary flows due to its smooth trunk-to-limb transition, while also splitting the flow between the iliac limbs more evenly. In multiplanar models, the out-of-plane curvature was the greatest cause of skewed flow, which reduced the benefits of the tapered stent-graft.


Journal of Biomechanics | 2013

Stent graft performance in the treatment of abdominal aortic aneurysms: The influence of compliance and geometry

Liam Morris; Florian Stefanov; Tim McGloughlin

The long-term success of the endovascular procedure for the treatment of Abdominal Aortic Aneurysms (AAAs ) depends on the secure fixation of the proximal end and the geometry of the stent-graft (SG) device. Variations in SG types can affect proximal fixation and SG hemodynamics. Such hemodynamic variations can have a catastrophic effect on the vascular system and may result from a SG/arterial wall compliance mismatch and the sudden decrease in cross-sectional area at the bifurcation, which may result in decreased distal perfusion, increased pressure wave reflection and increased stress at the interface between the stented and non-stented portion of the vessel. To examine this compliance mismatch, a commercial SG device was tested experimentally under a physiological pressure condition in a silicone AAA model based on computed tomography scans. There was a considerable reduction in compliance of 54% and an increase in the pulse wave velocity of 21%, with a significant amount of the forward pressure wave being reflected. To examine the SG geometrical effects, a commercial bifurcated geometry was compared computationally and experimentally with a geometrical taper in the form of a blended section, which provided a smooth transition from the proximal end to both iliac legs. The sudden contraction of commercial SG at the bifurcation region causes flow separation within the iliac legs, which is known to cause SG occlusion and increased proximal pressure. The blended section along the bifurcation region promotes a greater uniformity of the fluid flow field within the distal legs, especially, during the deceleration phase with reduced boundary layer reversal. In order to reduce the foregoing losses, abrupt changes of cross-section should be avoided. Geometrical tapers could lead to improved clinical outcomes for AAA SGs.


Medical Engineering & Physics | 2011

In vitro evaluation of the effects of intraluminal thrombus on abdominal aortic aneurysm wall dynamics

Florentina Ene; Carine Gachon; Patrick Delassus; Ronan Carroll; Florian Stefanov; Padraig O’Flynn; Liam Morris

The optimum time to treat abdominal aortic aneurysms (AAAs) still remains an uncertain issue. The decision to intervene does not take in account the effects that wall curvature, intraluminal thrombus (ILT) properties and thickness have on rupture. The role of ILT in aneurysm dynamics and rupture has been controversial. In vitro testing of four silicone AAA models incorporating the ILT and aortic bifurcation was studied under physiological conditions. Pressures (P) and diameters (D) were analysed for models with and without ILT at different locations. The diametral strain, compliance and P/D curves were influenced by the presence, elastic stiffness and thickness of the ILT. In this case, the inclusion of ILT reduced the lumen area by 77% that resulted in a 0.5-81% reduction in compliance depending on ILT properties. With an increase in ILT stiffness from 0.05 to 0.2 MPa, the compliance was reduced by 81%. In the region of maximum diameter, there was a reduction of diametral strain and compliance except for the softer ILT which was more compliant throughout the proximal region. The shifting of the maximum diametral strain and compliance to the proximal neck was pronounced by an increase in ILT stiffness, thus creating a possible rupture site.


Journal of Endovascular Therapy | 2016

Systematic Review and Patient-Level Meta-analysis of the Streamliner Multilayer Flow Modulator in the Management of Complex Thoracoabdominal Aortic Pathology:

Niamh Hynes; Sherif Sultan; Ala Elhelali; Edward B. Diethrich; Edel P Kavanagh; Mohamed Sultan; Florian Stefanov; Patrick Delassus; Liam Morris

Purpose: To examine the safety and short-term efficacy of the Streamliner Multilayer Flow Modulator (SMFM) in the management of patients with complex thoracoabdominal aortic pathology who are unfit for alternative interventions. Methods: Biomedical databases were systematically searched for articles published between 2008 and 2015 on the SMFM. A patient-level meta-analysis was used to evaluate aneurysm-related survival. Secondary outcomes were all-cause survival, stroke, spinal cord ischemia, renal impairment, and branch vessel patency. Other considerations were the impact of compliance with the instructions for use (IFU) on clinical outcome. Mean values and Kaplan-Meier estimates are presented with the 95% confidence interval (CI). Results: Fifteen articles (3 multicenter cohort studies, 3 observational cohort studies, and 9 case reports) were included, presenting 171 patients (mean age 68.8±12.3 years; 139 men). The mean aneurysm diameter was 6.7±1.6 cm (95% CI 6.4 to 6.9 cm). Technical success reported in 15 studies was 77.2%. Aneurysm-related survival at 1 year was 78.7% (95% CI 71.7% to 84.4%). One-year all-cause survival was 53.7% (95% CI 46.0% to 61.3%). There were no reported cases of spinal cord ischemia, renal insult, or stroke. Conclusion: The SMFM can be safely utilized in some patients with complex thoracoabdominal pathologies provided operators adhere to the IFU. The SMFM is a novel technology with no long-term published data on its sustained effectiveness and a lack of comparative studies. Randomized clinical trials, registries, and continued assessment are essential before this flow-modulating technology can be widely disseminated.


Journal of NeuroInterventional Surgery | 2017

Novel methodology to replicate clot analogs with diverse composition in acute ischemic stroke

Sharon Duffy; Michael Farrell; Kevin Mcardle; John Thornton; David Vale; Eleanor Rainsford; Liam Morris; David S. Liebeskind; Eugene MacCarthy; Michael Gilvarry

Background Translational research on clot composition may be advanced by the use of clot analogs for the preclinical evaluation of mechanical thrombectomy devices. This work describes a novel set of clot analogs to represent a diverse range of fibrin and red blood cell (RBC) compositions for use in acute ischemic stroke (AIS) occlusion models. Method Fresh whole blood obtained from ovine species was used to create seven different clot analog types. Five replicates were formed for each clot type. Varying amounts of whole blood constituents were mixed with thrombotic factors to create clots of varying compositions. Following histological processing, five sections from each clot were stained with H&E and Martius Scarlet Blue. Fibrin, RBC and white blood cell compositions were quantified. Results Histological examination demonstrated that the clot types had a distinct RBC and fibrin composition. No significant difference in composition was shown between replicates (p>0.05), indicating that the method of clot formation was reproducible. Percentage fibrin composition of the clot types was 1%, 8%, 31%, 38%, 64%, 79%, and 100%. A significant difference in fibrin and RBC composition between clot types was observed (p<0.05). Conclusions Seven different clot types were developed to replicate common AIS thrombi. These clot analogs may be beneficial for the preclinical evaluation of endovascular therapies, and may be applied to interventional technique training.


Annals of Biomedical Engineering | 2014

An Experimental Investigation of the Hemodynamic Variations Due to Aplastic Vessels Within Three-Dimensional Phantom Models of the Circle of Willis

Paul Fahy; Peter McCarthy; Sherif Sultan; Niamh Hynes; Patrick Delassus; Liam Morris

A complete circle of Willis (CoW) is found in approximately 30–50% of the population. Anatomical variations, such as absent or surgically clamped vessels, can result in undesirable flow patterns. These can affect the brain’s ability to maintain cerebral perfusion and the formation of cerebral aneurysms. An experimental test system was developed to simulate cerebral physiological conditions through three flexible 3D patient-specific models of complete and incomplete CoW geometries. Flow visualizations were performed with isobaric dyes and the mapped dye streamlines were tracked throughout the models. Three to seven flow impact locations were observed for all configurations, corresponding to known sites for aneurysmal formation. Uni and bi-directional cross-flows occurred along the communicating arteries. The greatest shunting of flow occurred for a missing pre-communicating anterior (A1) and posterior (P1) cerebral arteries. The anterior cerebral arteries had the greatest reduction (15–37%) in efferent flow rates for missing either a unilateral A1 or bilateral P1 segments. The bi-directional cross-flows, with multiple afferent flow mixing, observed along the communicating arteries may explain the propensity of aneurysm formation at these sites. Reductions in efferent flow rates due to aplastic vessel configurations may affect normal brain function.


Journal of Biomechanical Engineering-transactions of The Asme | 2005

That hemodynamics and not material mismatch is of primary concern in bypass graft failure : An experimental argument

T. O'Brien; Liam Morris; Michael Walsh; Timothy M. McGloughlin

The long term patency of end-to-side peripheral artery bypasses are low due to failure of the graft generally at the distal end of the bypass. Both material mismatch between the graft and the host artery and junction hemodynamics are cited as being major factors in disease formation at the junction. This study uses experimental methods to investigate the major differences in fluid dynamics and wall mechanics at the proximal and distal ends for rigid and compliant bypass grafts. Injection moulding was used to produce idealized transparent and compliant models of the graft/ artery junction configuration. An ePTFE graft was then used to stiffen one of the models. These models were then investigated using two-dimensional video extensometry and one-dimensional laser Doppler anemometry to determine the junction deformations and fluid velocity profiles for the rigid and complaint graft anastomotic junctions. Junction strains were evaluated and generally found to be under 5% with a peak stain measured in the stiff graft model junction of 8.3% at 100 mmHg applied pressure. Hemodynamic results were found to yield up to 40% difference in fluid velocities for the stiff/compliant comparison but up to 80% for the proximal/distal end comparisons. Similar strain conditions were assumed for the proximal and distal models while significant differences were noted in their associated hemodynamic changes. In contrasting the fluid dynamics and wall mechanics for the proximal and distal anastomoses, it is evident from the results of this study, that junction hemodynamics are the more variable factor.

Collaboration


Dive into the Liam Morris's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Patrick Delassus

Galway-Mayo Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Florian Stefanov

Galway-Mayo Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Niamh Hynes

Royal College of Surgeons in Ireland

View shared research outputs
Top Co-Authors

Avatar

Paul Fahy

Galway-Mayo Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sherif Sultan

Royal College of Surgeons in Ireland

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ala Elhelali

Galway-Mayo Institute of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge