Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Liisa Porra is active.

Publication


Featured researches published by Liisa Porra.


Physics in Medicine and Biology | 2001

Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent

S Bayat; G. Le Duc; Liisa Porra; Gilles Berruyer; Christian Nemoz; S. Monfraix; Stefan Fiedler; W Thomlinson; Pekka Suortti; C G Standertskjöld-Nordenstam; Anssi Sovijärvi

Small airways play a key role in the distribution of ventilation and in the matching of ventilation to perfusion. The purpose of this study was to introduce an imaging method that allows measurement of regional lung ventilation and evaluation of the function of airways with a small diameter. The experiments were performed at the Medical Beamline of the European Synchrotron Radiation Facility. Monochromatic synchrotron radiation beams were used to obtain quantitative respiration-gated images of lungs and airways in two anaesthetized and mechanically ventilated rabbits using inhaled stable xenon (Xe) gas as a contrast agent. Two simultaneous images were acquired at two different energies, above and below the K-edge of Xe. Logarithmic subtraction of the two images yields absolute Xe concentrations. This technique is known as K-edge subtraction (KES) radiography. Two-dimensional planar and CT images were obtained showing spatial distribution of Xe concentrations within the airspaces, as well as the dynamics of filling with Xe. Bronchi down to 1 mm in diameter were visible both in the subtraction radiographs and in tomographic images. Absolute concentrations of Xe gas were calculated within the tube carrying the inhaled gas mixture, small and large bronchi, and lung tissue. Local time constants of ventilation with Xe were obtained by following the evolution of gas concentration in sequential computed tomography images. The results of this first animal study indicate that KES imaging of lungs with Xe gas as a contrast agent has great potential in studies of the distribution of ventilation within the lungs and of airway function, including airways with a small diameter.


Physics in Medicine and Biology | 2005

Quantitative measurement of regional lung gas volume by synchrotron radiation computed tomography

S. Monfraix; S Bayat; Liisa Porra; Gilles Berruyer; Christian Nemoz; William Thomlinson; Pekka Suortti; Anssi Sovijärvi

The aim of this study was to assess the feasibility of a novel respiration-gated spiral synchrotron radiation computed tomography (SRCT) technique for direct quantification of absolute regional lung volumes, using stable xenon (Xe) gas as an inhaled indicator. Spiral SRCT with K-edge subtraction using two monochromatic x-ray beams was used to visualize and directly quantify inhaled Xe concentrations and airspace volumes in three-dimensional (3D) reconstructed lung images. Volume measurements were validated using a hollow Xe-filled phantom. Spiral images spanning 49 mm in lung height were acquired following 60 breaths of an 80% Xe-20% O2 gas mixture, in two anaesthetized and mechanically ventilated rabbits at baseline and after histamine aerosol inhalation. Volumetric images of 20 mm lung sections were obtained at functional residual capacity (FRC) and at end-inspiration. 3D images showed large patchy filling defects in peripheral airways and alveoli following histamine provocation. Local specific lung compliance was calculated based on FRC/end-inspiration images in normal lung. This study demonstrates spiral SRCT as a new technique for direct determination of regional lung volume, offering possibilities for non-invasive investigation of regional lung function and mechanics, with a uniquely high spatial resolution. An example of non-uniform volume distribution in rabbit lung following histamine inhalation is presented.


American Journal of Respiratory and Critical Care Medicine | 2009

Methacholine and Ovalbumin Challenges Assessed by Forced Oscillations and Synchrotron Lung Imaging

Sam Bayat; Satu Strengell; Liisa Porra; Tibor Z. Jánosi; Ferenc Peták; Heikki Suhonen; Pekka Suortti; Zoltán Hantos; Anssi Sovijärvi; Walid Habre

RATIONALE Methacholine (Mch) is routinely used to assess bronchial hyperreactivity; however, little is known about the differences in the lung response pattern between this provocation and that observed with ovalbumin (Ova) after allergic sensitization. OBJECTIVES To compare (1) the central versus peripheral effects of Mch and Ova within the lung by combining measurements of airway and tissue mechanics with synchrotron radiation (SR) imaging, and (2) to assess the extent to which mechanical and imaging parameters are correlated. METHODS We used the low-frequency forced oscillation technique and SR imaging in control (n = 12) and ovalbumin-sensitized (n = 13) rabbits, at baseline, during intravenous Mch infusion (2.5 microg/kg/min, 5.0 microg/kg/min, or 10.0 microg/kg/min), after recovery from Mch, and after intravenous Ova injection (2.0 mg). We compared intravenous Mch challenge with inhaled Mch (125 mg/ml, 90 s) in a separate group of control animals (n = 5). MEASUREMENTS AND MAIN RESULTS Airway conductance and tissue elastance were measured by low-frequency forced oscillation technique. The central airway cross-sectional area, the ventilated alveolar area, and the heterogeneity of specific ventilation were quantified by SR imaging. Mch infusion induced constriction predominantly in the central airways, whereas Ova provocation affected mainly the peripheral airways, leading to severe ventilation heterogeneities in sensitized animals. Mch inhalation affected both conducting and peripheral airways. The correlations between airway conductance and central airway cross-sectional area (R = 0.71) and between tissue elastance and ventilated alveolar area (R = -0.72) were strong. CONCLUSIONS The pattern of lung response caused by intravenous Mch and Ova are fundamentally different. Although inhaled Mch induces a heterogeneous lung response similar to that observed with intravenous allergen, these similar patterns are due to different mechanisms.


Journal of Synchrotron Radiation | 2008

Relics in medieval altarpieces? Combining X-ray tomographic, laminographic and phase-contrast imaging to visualize thin organic objects in paintings

Kris Krug; Liisa Porra; Paola Coan; Arie Wallert; Joris Dik; Andrea Coerdt; Alberto Bravin; Muthaffar Elyyan; Péter Reischig; L. Helfen; Tilo Baumbach

X-ray radiography is a common tool in the study of old master paintings. Transmission imaging can visualize hidden paint layers as well as the structure of the panel or canvas. In some medieval altarpieces, relics seem to have been imbedded in the wooden carrier of paintings. These are most probably thin organic fibrous materials such as paper or textile, which in traditional radiography are shadowed by the more absorbing surrounding material. This paper studies the application potential of synchrotron-based tomographic and laminographic imaging complemented with phase-contrast imaging for detection of such relics. The techniques are applied to a dummy painting. The results demonstrate that by using these imaging methods it is possible to three-dimensionally visualize hidden cavities in panels and detect thin fibrous low-Z materials sandwiched between a high-Z paint layer and a thick wooden panel.


Journal of Applied Physiology | 2009

Paradoxical conducting airway responses and heterogeneous regional ventilation after histamine inhalation in rabbit studied by synchrotron radiation CT

Sam Bayat; Liisa Porra; Heikki Suhonen; Pekka Suortti; Anssi Sovijärvi

We studied both central conducting airway response and changes in the distribution of regional ventilation induced by inhaled histamine in healthy anesthetized and mechanically ventilated rabbit using a novel xenon-enhanced synchrotron radiation computed tomography (CT) imaging technique, K-edge subtraction imaging (KES). Images of specific ventilation were obtained using serial KES during xenon washin, in three axial lung slices, at baseline and twice after inhalation of histamine aerosol (50 or 125 mg/ml) in two groups of animals (n = 6 each). Histamine inhalation caused large clustered areas of poor ventilation, characterized by a drop in average specific ventilation (sV(m)), but an increase in sV(m) in the remaining lung zones indicating ventilation redistribution. Ventilation heterogeneity, estimated as coefficient of variation (CV) of sV(m) significantly increased following histamine inhalation. The area of ventilation defects and CV were significantly larger with the higher histamine dose. In conducting airways, histamine inhalation caused a heterogeneous airway response combining narrowing and dilatation in individual airways of different generations, with the probability for constriction increasing peripherally. This finding provides further in vivo evidence that airway reactivity in response to inhaled histamine is complex and that airway response may vary substantially with location within the bronchial tree.


Physics in Medicine and Biology | 2008

Simultaneous in vivo synchrotron radiation computed tomography of regional ventilation and blood volume in rabbit lung using combined K-edge and temporal subtraction

Heikki Suhonen; Liisa Porra; Sam Bayat; Anssi Sovijärvi; Pekka Suortti

In K-edge subtraction (KES) imaging with synchrotron radiation computed tomography (SRCT), two images are taken simultaneously using energies above and below the K-absorption edge of a contrast agent. A logarithmic difference image reveals the contrast agent concentration with good accuracy. Similarly, in temporal subtraction imaging (TSI) the reference image is taken before the introduction of the contrast agent. Quantitative comparisons of in vivo images of rabbit lung indicated that similar results for concentrations of iodine in blood vessels and xenon in airways are obtained by KES and TSI, but the level of noise and artifacts was higher in the latter. A linear fit showed that in the lung parenchyma rho(TSI) = (0.97 +/- 0.03)rho(KES) + (0.00 +/- 0.05) for xenon and rho(TSI) = (1.21 +/- 0.15)rho(KES) + (0.0 +/- 0.1) for iodine. For xenon the calculation of time constant of ventilation gave compatible values for both of the methods. The two methods are combined for the simultaneous determination of the xenon concentration (by KES) and the iodine concentration (by TSI) in lung imaging, which will allow simultaneous in vivo determination of ventilation and perfusion.


Anesthesiology | 2013

Effect of positive end-expiratory pressure on regional ventilation distribution during mechanical ventilation after surfactant depletion.

Sam Bayat; Liisa Porra; Gergely Albu; Heikki Suhonen; Satu Strengell; P. Suortti; Anssi Sovijärvi; Ferenc Peták; Walid Habre

Background:Ventilator-induced lung injury occurs due to exaggerated local stresses, repeated collapse, and opening of terminal air spaces in poorly aerated dependent lung, and increased stretch in nondependent lung. The aim of this study was to quantify the functional behavior of peripheral lung units in whole-lung lavage-induced surfactant depletion, and to assess the effect of positive end-expiratory pressure. Methods:The authors used synchrotron imaging to measure lung aeration and regional specific ventilation at positive end-expiratory pressure of 3 and 9 cm H2O, before and after whole-lung lavage in rabbits. Respiratory mechanical parameters were measured, and helium-washout was used to assess end-expiratory lung volume. Results:Atelectatic, poorly, normally aerated, hyperinflated, and trapped regions could be identified using the imaging technique used in this study. Surfactant depletion significantly increased atelectasis (6.3 ± 3.3 [mean ± SEM]% total lung area; P = 0.04 vs. control) and poor aeration in dependent lung. Regional ventilation was distributed to poorly aerated regions with high (16.4 ± 4.4%; P < 0.001), normal (20.7 ± 5.9%; P < 0.001 vs. control), and low (5.7 ± 1.2%; P < 0.05 vs. control) specific ventilation. Significant redistribution of ventilation to normally aerated nondependent lung regions occurred (41.0 ± 9.6%; P = 0.03 vs. control). Increasing positive end-expiratory pressure level to 9 cm H2O significantly reduced poor aeration and recruited atelectasis, but ventilation redistribution persisted (39.2 ± 9.5%; P < 0.001 vs. control). Conclusions:Ventilation of poorly aerated dependent lung regions, which can promote the local concentration of mechanical stresses, was the predominant functional behavior in surfactant-depleted lung. Potential tidal recruitment of atelectatic lung regions involved a smaller fraction of the imaged lung. Significant ventilation redistribution to aerated lung regions places these at risk of increased stretch injury.


Critical Care Medicine | 2011

Effect of positive end-expiratory pressure on regional ventilation distribution during bronchoconstriction in rabbit studied by synchrotron radiation imaging.

Liisa Porra; Heikki Suhonen; Pekka Suortti; Anssi Sovijärvi; Sam Bayat

Objective:To assess the effects of positive end-expiratory pressure on regional ventilation distribution in normal lung and after histamine-induced bronchoconstriction. Design:Experimental study. Setting:International research laboratory. Subjects:Six healthy New Zealand rabbits weighing 2.5 ± 0.1 kg. Interventions:Rabbits were anesthetized, tracheostomized, paralyzed, and mechanically ventilated. Synchrotron radiation computed tomography images of tissue density and specific ventilation were acquired using K-edge subtraction imaging with inhaled stable xenon gas in middle and caudal thoracic levels on 0 and 5 cm H2O positive end-expiratory pressure at baseline and twice after histamine inhalation. Measurements and Main Results:At baseline, a positive end-expiratory pressure of 5 cm H2O significantly increased lung volume. Histamine inhalation caused patchy areas of decreased specific ventilation, including some areas with no ventilation. After histamine, positive end-expiratory pressure significantly increased the area of well-ventilated lung regions and decreased the heterogeneity of specific ventilation. This improvement went together with a significant but limited increase in the area of hyperinflated lung zones. Conclusions:The findings of this study suggest that in mechanically ventilated rabbit with severely heterogeneous bronchoconstriction, a positive end-expiratory pressure of 5 cm H2O significantly improves regional ventilation homogeneity through dilation of flow-limited airways and recruitment of closed airways.


European Journal of Radiology | 2008

Imaging of lung function using synchrotron radiation computed tomography: What's new?

Sam Bayat; Liisa Porra; Heikki Suhonen; Tibor Z. Jánosi; Satu Strengell; Walid Habre; Ferenc Peták; Zoltán Hantos; Pekka Suortti; Anssi Sovijärvi

There is a growing interest in imaging techniques as non-invasive means of quantitatively measuring regional lung structure and function. Abnormalities in lung ventilation due to alterations in airway function such as those observed in asthma and COPD are highly heterogeneous, and experimental methods to study this heterogeneity are crucial for better understanding of disease mechanisms and drug targeting strategies. In severe obstructive diseases requiring mechanical ventilation, the optimal ventilatory strategy to achieve recruitment of poorly ventilated lung zones remains a matter of considerable debate. We have used synchrotron radiation computed tomography (SRCT) for the in vivo study of regional lung ventilation and airway function. This imaging technique allows direct quantification of stable Xenon (Xe) gas used as an inhaled contrast agent using K-edge subtraction imaging. Dynamics of Xe wash-in can be used to calculate quantitative maps of regional specific lung ventilation. More recently, the development of Spiral-CT has allowed the acquisition of 3D images of the pulmonary bronchial tree and airspaces. This technique gives access to quantitative measurements of regional lung volume, ventilation, and mechanical properties. Examples of application in an experimental model of allergic asthma and in imaging lung recruitment as a function of mechanical ventilation parameters will be presented. The future orientations of this technique will be discussed.


Journal of Synchrotron Radiation | 2014

Radiation dose and image quality in K-edge subtraction computed tomography of lung in vivo

Satu Strengell; Jani Keyriläinen; Pekka Suortti; Sam Bayat; Anssi Sovijärvi; Liisa Porra

K-edge subtraction computed tomography (KES-CT) allows simultaneous imaging of both structural features and regional distribution of contrast elements inside an organ. Using this technique, regional lung ventilation and blood volume distributions can be measured experimentally in vivo. In order for this imaging technology to be applicable in humans, it is crucial to minimize exposure to ionizing radiation with little compromise in image quality. The goal of this study was to assess the changes in signal-to-noise ratio (SNR) of KES-CT lung images as a function of radiation dose. The experiments were performed in anesthetized and ventilated rabbits using inhaled xenon gas in O2 at two concentrations: 20% and 70%. Radiation dose, defined as air kerma (Ka), was measured free-in-air and in a 16 cm polymethyl methacrylate phantom with a cylindrical ionization chamber. The dose free-in-air was varied from 2.7 mGy to 8.0 Gy. SNR in the images of xenon in air spaces was above the Rose criterion (SNR > 5) when Ka was over 400 mGy with 20% xenon, and over 40 mGy with 70% xenon. Although in human thorax attenuation is higher, based on these findings it is estimated that, by optimizing the imaging sequence and reconstruction algorithms, the radiation dose could be further reduced to clinically acceptable levels.

Collaboration


Dive into the Liisa Porra's collaboration.

Top Co-Authors

Avatar

Sam Bayat

University of Picardie Jules Verne

View shared research outputs
Top Co-Authors

Avatar

Anssi Sovijärvi

Helsinki University Central Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Heikki Suhonen

European Synchrotron Radiation Facility

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Loïc Dégrugilliers

University of Picardie Jules Verne

View shared research outputs
Top Co-Authors

Avatar

Ludovic Broche

European Synchrotron Radiation Facility

View shared research outputs
Researchain Logo
Decentralizing Knowledge