Linda D. Stewart
Queen's University Belfast
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Linda D. Stewart.
Toxicon | 2009
Linda D. Stewart; Christopher T. Elliott; Andrew D. Walker; Rhonda Curran; Lisa Connolly
Okadaic acid (OA) and structurally related toxins dinophysistoxin-1 (DTX-1), and DTX-2, are lipophilic marine biotoxins. The current reference method for the analysis of these toxins is the mouse bioassay (MBA). This method is under increasing criticism both from an ethical point of view and because of its limited sensitivity and specificity. Alternative replacement methods must be rapid, robust, cost effective, specific and sensitive. Although published immuno-based detection techniques have good sensitivities, they are restricted in their use because of their inability to: (i) detect all of the OA toxins that contribute to contamination; and (ii) factor in the relative toxicities of each contaminant. Monoclonal antibodies (MAbs) were produced to OA and an automated biosensor screening assay developed and compared with ELISA techniques. The screening assay was designed to increase the probability of identifying a MAb capable of detecting all OA toxins. The result was the generation of a unique MAb which not only cross-reacted with both DTX-1 and DTX-2 but had a cross-reactivity profile in buffer that reflected exactly the intrinsic toxic potency of the OA group of toxins. Preliminary matrix studies reflected these results. This antibody is an excellent candidate for the development of a range of functional immunochemical-based detection assays for this group of toxins.
Analytical Chemistry | 2009
Linda D. Stewart; Philipp Hess; Lisa Connolly; Christopher T. Elliott
A rapid analytical optical biosensor-based immunoassay was developed and validated for the detection of okadaic acid (OA) and its structurally related toxins from shellfish matrix. The assay utilizes a monoclonal antibody which binds to the OA group of toxins in order of their toxicities, resulting in a pseudofunctional assay. Single-laboratory validation of the assay for quantitative detection of OA determined that it has an action limit of 120 microg/kg, a limit of detection of 31 microg/kg, and a working range of 31-174 microg/kg. The midpoint on the standard matrix calibration curve is 80 microg/kg, half the current regulatory limit. Inter- and intra-assay studies of negative mussel samples spiked with various OA concentrations produced average coefficient of variation (CV) and standard deviation (SD) values of 7.9 and 10.1, respectively. The assay was also validated to confirm the ability to accurately codetect and quantify dinophysistoxin-1 (DTX-1), DTX-2, and DTX-3 from shellfish matrix. Alkaline hydrolysis was not required for the detection of DTX-3 from matrix. Excellent correlations with the data generated by the biosensor method and liquid chromatography/tandem mass spectrometry (LC/MS/MS) were obtained using a certified reference material (R(2) = 0.99), laboratory reference material, and naturally contaminated mussel samples (R(2) = 0.97). This new procedure could be used as a rapid screening procedure replacing animal-based tests for DSP toxins.
Journal of Medical Microbiology | 1991
Deborah A. Lutton; Sheila Patrick; A. D. Crockard; Linda D. Stewart; Michael J. Larkin; Evelyn Dermott; T. A. McNEILL
The reactivity of four different monoclonal antibodies (MAbs) with populations of Bacteroides fragilis NCTC 9343, enriched by density gradient centrifugation for a large capsule, small capsule and electron-dense layer (EDL) only visible by electronmicroscopy, was examined. The MAbs reacted strongly with polysaccharides present in both the large capsule- and EDL-enriched populations but not in the small capsule-enriched populations. The pattern of labelling was determined by immunoblotting, immunofluorescence and immuno-electronmicroscopy, and flow cytometry. The MAbs labelled cell membrane-associated epitopes in the large capsule- and EDL-enriched populations and cell-free material in the EDL population. By immunoblotting, ladders of repeating polysaccharide subunits were evident in the EDL population but not in the large capsule population. The proportion of cells labelled within each population was determined by flow cytometry. The reactivity of another MAb with the small capsule population was confirmed by flow cytometry. A qualitative indication of epitope expression was obtained by examination of the flow cytometric profiles. Differential expression of the same saccharide epitope was observed both between and within structurally distinct B. fragilis populations. The MAbs were species-specific and cross-reacted with several recent clinical isolates. These polysaccharides may be relevant to the virulence of B. fragilis.
Journal of Medical Microbiology | 1995
Sheila Patrick; Linda D. Stewart; N. Damani; K. G. Wilson; Deborah A. Lutton; Michael J. Larkin; Ian R. Poxton; R. Brown
A monospecific polyclonal antiserum, prepared against Bacteroides fragilis common polysaccharide antigen purified by polyacrylamide gel immunoblot detected B. fragilis, B. thetaiotaomicron, B. ovatus and Prevotella melaninogenica in pus samples from various anatomical sites by immunofluorescence microscopy of the pus. With standard clinical laboratory culture methods, 36% of 147 samples were positive for one or more of the above bacteria. Of these, B. fragilis accounted for 33%. By immunofluorescent labelling of pus with the common antigen antiserum the detection of these bacteria in the samples increased to 50%. All nine of the blood cultures in which B. fragilis was detected by culture contained bacteria positive for the common antigen. Immunofluorescent labelling of pus samples with a selection of monoclonal antibodies specific for surface polysaccharides which are known to be antigenically variable in culture in vitro and in an animal model of infection showed that these polysaccharides are also variable in natural infection. The results indicate that the common polysaccharide antigen, in contrast to the variable surface polysaccharides, is a suitable target for the immunodetection of B. fragilis in clinical samples from a range of anatomical sites.
PLOS ONE | 2013
Linda D. Stewart; James McNair; Lyanne McCallan; Alan Gordon; Irene R. Grant
Immunomagnetic separation (IMS) can selectively isolate and concentrate Mycobacterium bovis cells from lymph node tissue to facilitate subsequent detection by PCR (IMS-PCR) or culture (IMS-MGIT). This study describes application of these novel IMS-based methods to test for M. bovis in a survey of 280 bovine lymph nodes (206 visibly lesioned (VL), 74 non-visibly lesioned (NVL)) collected at slaughter as part of the Northern Ireland bovine TB eradication programme. Their performance was evaluated relative to culture. Overall, 174 (62.1%) lymph node samples tested positive by culture, 162 (57.8%) by IMS-PCR (targeting IS6110), and 191 (68.2%) by IMS-MGIT culture. Twelve (6.9%) of the 174 culture positive lymph node samples were not detected by either of the IMS-based methods. However, an additional 79 M. bovis positive lymph node samples (27 (13.1%) VL and 52 (70.3%) NVL) were detected by the IMS-based methods and not by culture. When low numbers of viable M. bovis are present in lymph nodes (e.g. in NVLs of skin test reactor cattle) decontamination prior to culture may adversely affect viability, leading to false negative culture results. In contrast, IMS specifically captures whole M. bovis cells (live, dead or potentially dormant) which are not subject to any deleterious treatment before detection by PCR or MGIT culture. During this study only 2.7% of NVL lymph nodes tested culture positive, whereas 70.3% of the same samples tested M. bovis positive by the IMS-based tests. Results clearly demonstrate that not only are the IMS-based methods more rapid but they have greater detection sensitivity than the culture approach currently used for the detection of M. bovis infection in cattle. Adoption of the IMS-based methods for lymph node testing would have the potential to improve M. bovis detection in clinical samples.
Journal of Applied Microbiology | 2013
J. Morton; Nitsara Karoonuthaisiri; Linda D. Stewart; Michalina Oplatowska; Christopher T. Elliott; Irene R. Grant
The objectives of this study were to produce Salmonella‐specific peptide ligands by phage display biopanning and evaluate their use for magnetic separation (MS).
Journal of Clinical Microbiology | 2012
Linda D. Stewart; James McNair; Lyanne McCallan; Suzan Thompson; Leonid Kulakov; Irene R. Grant
ABSTRACT This study describes the development and optimization of an immunomagnetic separation (IMS) method to isolate Mycobacterium bovis cells from lymph node tissues. Gamma-irradiated whole M. bovis AF2122/97 cells and ethanol-extracted surface antigens of such cells were used to produce M. bovis-specific polyclonal and monoclonal antibodies in rabbits and mice. They were also used to generate M. bovis-specific peptide ligands by phage display biopanning. The various antibodies and peptide ligands obtained were used to coat MyOne tosyl-activated Dynabeads (Life Technologies), singly or in combination, and evaluated for IMS. Initially, M. bovis capture from Middlebrook 7H9 broth suspensions (concentration range, 10 to 105 CFU/ml) was evaluated by IMS combined with an M. bovis-specific touchdown PCR. IMS-PCR results and, subsequently, IMS-culture results indicated that the beads with greatest immunocapture capability for M. bovis in broth were those coated simultaneously with a monoclonal antibody and a biotinylated 12-mer peptide. These dually coated beads exhibited minimal capture (mean of 0.36% recovery) of 12 other Mycobacterium spp. occasionally encountered in veterinary tuberculosis (TB) diagnostic laboratories. When the optimized IMS method was applied to various M. bovis-spiked lymph node matrices, it demonstrated excellent detection sensitivities (50% limits of detection of 3.16 and 57.7 CFU/ml of lymph node tissue homogenate for IMS-PCR and IMS-culture, respectively). The optimized IMS method therefore has the potential to improve isolation of M. bovis from lymph nodes and hence the diagnosis of bovine tuberculosis.
Journal of Applied Microbiology | 2013
Linda D. Stewart; Antonio Foddai; Christopher T. Elliott; Irene R. Grant
The objective of this study was to develop a novel screening method for detection of viable Mycobacterium avium subsp. paratuberculosis (Map) in milk and faeces, as a rapid alternative to Map culture.
PLOS ONE | 2013
Josephine Morton; Nitsara Karoonuthaisiri; Linda D. Stewart; Christopher T. Elliott; Irene R. Grant
The objective of this study was to produce phage display-derived binders with the ability to distinguish Listeria monocytogenes from other Listeria spp., which may have potential utility to enhance detection of Listeria monocytogenes. To obtain binders with the desired binding specificity a series of surface and solution phage-display biopannings were performed. Initially, three rounds of surface biopanning against gamma-irradiated L. monocytogenes serovar 4b cells were performed followed by an additional surface biopanning round against L. monocytogenes 4b which included prior subtraction biopanning against gamma-irradiated L. innocua cells. In an attempt to further enhance binder specificity for L. monocytogenes 4b two rounds of solution biopanning were performed, both rounds included initial subtraction solution biopanning against L. innocua. Subsequent evaluations were performed on the phage clones by phage binding ELISA. All phage clones tested from the second round of solution biopanning had higher specificity for L. monocytogenes 4b than for L. innocua and three other foodborne pathogens ( Salmonella spp., Escherichia coli and Campylobacter jejuni). Further evaluation with five other Listeria spp. revealed that one phage clone in particular, expressing peptide GRIADLPPLKPN, was highly specific for L. monocytogenes with at least 43-fold more binding capability to L. monocytogenes 4b than to any other Listeria sp. This proof-of-principle study demonstrates how a combination of surface, solution and subtractive biopanning was used to maximise binder specificity. L. monocytogenes-specific binders were obtained which could have potential application in novel detection tests for L. monocytogenes, benefiting both the food and medical industries.
PLOS ONE | 2016
Lorna O’Brien; Linda D. Stewart; Sam A. J. Strain; Irene R. Grant
The generation of novel Mycobacterium avium subsp. paratuberculosis (MAP)-specific monoclonal antibodies and phage-display derived peptide binders, along with their application for the magnetic separation (MS) of MAP cells, is described. Our aim was to achieve even greater MAP capture capability than is possible with peptide-mediated magnetic separation (PMS) using a 50:50 mix of biotinylated-aMp3 and biotinylated-aMptD peptide-coated beads. Gamma-irradiated whole MAP cells and ethanol extracted antigens (EEA) from these cells were used to elicit an immune response and as phage-display biopanning targets. A range of novel binders was obtained and coated onto paramagnetic beads, both individually and in various combinations, for MS evaluation. IS900 PCR was employed after MS to provide quick results. Capture sensitivity was assessed using a range of MAP concentrations after which the most promising beads were tested for their specificity for MAP, by performing MS followed by culture using 10 other Mycobacterium species. Magnetic beads coated with the biotinylated EEA402 peptide demonstrated a greater level of MAP capture than the current PMS method, even when low numbers of MAP (<10 cfu/ml) were present; however these beads also captured a range of other mycobacteria and so lacked capture specificity. Magnetic beads coated with monoclonal antibodies 6G11 and 15D10 (used as a 50:50 mix or as dually coated beads) also demonstrated improved MAP capture relative to the current PMS method, but with little cross-reactivity to other Mycobacterium spp. Therefore, two new MS protocols are suggested, the application of which would be dependent upon the required endpoint. Biotinylated EEA402-coated beads could potentially be used with a MAP-specific PCR to ensure detection specificity, while beads coated with 6G11 and 15D10 monoclonal antibodies could be used with culture or the phage amplification assay.
Collaboration
Dive into the Linda D. Stewart's collaboration.
Thailand National Science and Technology Development Agency
View shared research outputs