Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Linong Wang is active.

Publication


Featured researches published by Linong Wang.


Canadian Journal of Electrical and Computer Engineering-revue Canadienne De Genie Electrique Et Informatique | 2014

Research on Complex Gap Discharge Model of Live Working on EHV and UHV High-Voltage Transmission Lines

Linong Wang; Qiushi Zhang; Jianxun Hu; Kai Liu; Tian Wu; Junhua Wang

This paper obtained the switching impulse flashover characteristic of live working complex gap on extra high voltage (EHV) and ultra high voltage (UHV) high-voltage transmission lines by a large number of experiments. Based on the experimental data and the leader inception discharge model, the complex gap discharge development during the process of entering equipotential and its influencing factors have been analyzed with the electric filed calculation method. Moreover, considering the practical conditions in live working sites, a complex gap discharge model appropriate for side live working on EHV and UHV high-voltage transmission lines has been proposed by introducing a revision coefficient km. It has been found that km is related to the working position and the structure of high-voltage electrode. Through further research on the establishment of the functional relationship, it can provide a comparable accurate theoretical calculation method for the research on the complex gap of live working and can give a guideline for optimizing the test plans.


ieee pes asia-pacific power and energy engineering conference | 2010

Experimental Investigation on Live Working Requirements for 1000kV Ultra High Voltage AC Transmission Line

Yi Hu; Linong Wang; Kai Liu; Guiwei Shao; Ting Liu; Jianxun Hu; Ying Xu; Bin Xiao

To provide technical support and reference for the design and maintenance of 1,000kV AC transmission line, the experimental investigation on live working was carried out systematically. First, according to the system parameters, the over-voltage level and its statistical distribution during the process of live working were analyzed and calculated. And then, at 1:1 ratio scale simulated tower, tests were performed on different live working positions. Based on these, the minimum approach distance and complex gaps were obtained, and the minimum effective insulating length of insulating tools was found too. According to the practical conditions of the lines, suitable full-set screening clothes were developed and tested. And the electric field intensity on human-body surface inside and outside of the screening clothes at different working positions was measured. The results indicate that the climbing worker should dress screening clothes, and the equal potential worker should wear additional electric field shield mask, and use potential rod during the equal potential process.


ieee international magnetics conference | 2015

Design of the rats experiment playground based on the magnetic resonant wireless energy transmission technology

Jingchao Wang; Kaipei Liu; Linong Wang; M. Sun

The radii of both wires are 1 mm . It can be found that the curve of the coupling coefficient of circular coils drops regularly while the horizontal displacement increases from 0 mm to 40 mm . The coupling coefficients between circular coils are 0 .1494, as the horizontal displacement is 25mm . Therefore, the circular coils have enough stability with the horizontal displacement variation.


ieee international magnetics conference | 2015

Temperature prediction study of cable joint conductor based on the PSO algorithms of BP neural network

H. Zhou; Jingchao Wang; K. Liu; Linong Wang

Summary form only given. In power system, cable line is a quite important equipment while cable joint is one of its weak link, which may cause severe losses once break down . Allowing that the cable joint will be accompanied by a rise in temperature no matter what kind of failure occurs, a principle that real-time monitoring and predicting temperature of cable joint is available to own a comprehensive understanding of the cable lines operation, and discover the hidden trouble in cable and improving the safe operation performance of cable wires . Compared with the low monitoring configuration sensitivity, high maintenance cost and low prediction accuracy of traditional monitoring methods, this paper proposes an algorithm based on the PSO(Particle Swarm Optimization) of BP neural network to predict the temperature of wire cable joint which can make up for the present methods temperature detection insufficiency of the cable joint conductor effectively and improve the faults of low prediction accuracy, high initial weight sensitivity of the single BP neural network purposefully . For the collected temperature monitoring data of cable joint, first of all, we should delete some error data that because of misoperation or measuring error, find out the factors which closely associated with forecast . and then imported in MATLAB for data classification, weight setting, data normalization preprocessing, etc . The last is to build the network . In this paper, it is assigned that the individual values optimized by PSO algorithm to the BP networks initial weight and threshold, through training, simulating and obtaining the prediction results for building the new BP neural network . The simulation results show that the BP neural network whose initial weights and threshold optimized by the PSO algorithm has higher prediction precision of conductor temperature and good local searching ability, and also possess the lower probability of network into a local optimum, compared with the single BP neural network . The simulation results as shown in figure 1 Prediction curve of the BP neural network and the PSO algorithms of BP neural network; Figure 2 Error curve of the BP neural network and the PSO algorithms of BP neural network


ieee international magnetics conference | 2015

Research of acoustic vibration technique in online defects detection in porcelain post insulator

K. Liang; Junhua Wang; K. Liu; Linong Wang

High voltage porcelain post insulator is one of the most important facilities in power plant and substation in the procedure of generating and transmitting electric energy which is used to hold up the electric transmission line as support bracket and insulate high voltage, when deteriorated or cracked it will pose a serious threat to the normal operation of power system.


ieee pes asia-pacific power and energy engineering conference | 2010

Research of Safety Protection for Live Working on 1000kV AC Ultra High Voltage Transmission Line

Kai Liu; Linong Wang; Yi Hu; Guiwei Shao; Ting Liu; Jianxun Hu; Bin Xiao

Safety protection research for live working on 1000 kV AC transmission line was made. The screening clothes for live working was developed and tested. Both material of clothes and the characteristics were researched with standards. According to the actual situation of operation, the electric field intensity on different parts of body and the current passing through human were measured in equal-potential process. The research results show the clothes can meet the safety protection requirements for live work on 1000 kV transmission line. The working man should wear full set screening clothes with face screening mask and the potential rod should be used during equal-potential process.


ieee pes asia-pacific power and energy engineering conference | 2009

Research on Minimum Approach Distance for Live Working on 1000kV Ultra High Voltage AC Transmission Line

Linong Wang; Kai Liu; Yi Hu; Guiwei Shao; Ting Liu; Jianxun Hu; Bin Xiao

The switching impulse discharge performances of live working electric structure on outer phase, middle phase and tension string in 1000kV AC transmission line were studied. And based on the results, by calculation and analysis of the risk of live working, the minimum approach distance for live working was determined.


ieee pes asia-pacific power and energy engineering conference | 2009

Research of Effect of Wind-Blown Rain on Power Frequency Flashover Characteristic of Conductor-Tower Air Gap

Yi Hu; Linong Wang; Kai Liu; Guiwei Shao; Ting Liu; Jianxun Hu

At 1:1 ratio scale simulated tower, the effect of rainfall, wind and wind-blown rain on power frequency flashover characteristic of conductor-tower air gap was initial systematically researched at inner and outdoor. The result is that, rainfalK wind speedy wind direction^ wind-blown rain can effect the power frequency flashover characteristic of air gap. The rain reduce the flashover voltage obviously, especially the air gap is small. When the air gap is 1.2m, and the rainfall intensity is 14.4mm/min, the flashover voltage reduced 13.3%, when the air gap is 0.6m, the flashover voltage reduced 16.2% with the same rainfall intensity. The resistivity of rainwater also has influence on the power frequency flashover characteristic of air gap, but its influence is less than that of rainfall intensity. When the resistivity of rainwater is greater than 4x10 3 Omegaldrcm, as the resistivity increase further, the increasing of flashover voltage has the tendency of saturation; when the resistivity of rainwater is less than 2x10 3 Omegaldrcm, the flashover voltage decreases rapidly as the decreasing of the resistivity, and when the resistivity decreases further, the decreasing speed of flashover voltage has the tendency of increasing. The influence of rainfall path is not obviously to the flashover. The wind direction and speed also influence the flashover voltage, when the wind direction is parallel to the discharging path, the strong wind decreases the flashover voltage of conductor-tower air gap, when the wind direction is vertical to the discharging path, the strong wind increases the flashover voltage of conductor-tower air gap. When there is wind-blown rain, and the wind path is parallel to the discharging path, the flashover voltage is less than that when there is only rainfall. And in the test, the influence of wind-blown rain to the power frequency flashover of air gap is about the lineal superposition of the influence on only rainfall and only wind. - Through the test, the following result is putted forward, in the extremely atrocious weather, the air gap of which the power frequency withstand voltage is more than the maximum operating phase voltage of 500kV transmission line is 1.25m when there is no step bolt (The data is not corrected to the high altitude localities.).The research could supply technical base for the design of minimum air gap space of electric transmission line in adverse weather, reduce the windage yaw discharge fault and accident rate, and improve safety operation level and economic benefit of transmission line construction.


Archive | 2012

Practice and simulation training system and method for power distribution live-wire work

Linong Wang; Jianxun Hu; Kai Liu; Ting Liu; Bin Xiao; Zheng Ye


Archive | 2011

Truly simulation training system of distribution live line works

Linong Wang; Jianxun Hu; Kai Liu; Ting Liu; Bin Xiao; Zheng Ye

Collaboration


Dive into the Linong Wang's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bin Xiao

Electric Power Research Institute

View shared research outputs
Top Co-Authors

Avatar

Ting Liu

Electric Power Research Institute

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yi Hu

Electric Power Research Institute

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Tian Wu

Electric Power Research Institute

View shared research outputs
Researchain Logo
Decentralizing Knowledge