Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Lorenz Räber is active.

Publication


Featured researches published by Lorenz Räber.


Journal of the American College of Cardiology | 2012

Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation.

Guillermo J. Tearney; Evelyn Regar; Takashi Akasaka; Tom Adriaenssens; Hiram G. Bezerra; Brett E. Bouma; Nico Bruining; Jin-man Cho; Saqib Chowdhary; Marco A. Costa; Ranil de Silva; Jouke Dijkstra; Carlo Di Mario; Darius Dudeck; Erlin Falk; Marc D. Feldman; Peter J. Fitzgerald; Hector Garcia Garcia; Nieves Gonzalo; Juan F. Granada; Giulio Guagliumi; Niels R. Holm; Yasuhiro Honda; Fumiaki Ikeno; Masanori Kawasaki; Janusz Kochman; Lukasz Koltowski; Takashi Kubo; Teruyoshi Kume; Hiroyuki Kyono

OBJECTIVES The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease. BACKGROUND Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of ~10 μm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and the interest in using this technology is growing. Incorporation of IVOCT in research and daily clinical practice can be facilitated by the development of uniform terminology and consensus-based standards on use of the technology, interpretation of the images, and reporting of IVOCT results. METHODS The IWG-IVOCT, comprising more than 260 academic and industry members from Asia, Europe, and the United States, formed in 2008 and convened on the topic of IVOCT standardization through a series of 9 national and international meetings. RESULTS Knowledge and recommendations from this group on key areas within the IVOCT field were assembled to generate this consensus document, authored by the Writing Committee, composed of academicians who have participated in meetings and/or writing of the text. CONCLUSIONS This document may be broadly used as a standard reference regarding the current state of the IVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVOCT data.


The New England Journal of Medicine | 2008

Recurrent rearrangements of chromosome 1q21.1 and variable pediatric phenotypes

Mefford Hc; Andrew J. Sharp; Carl Baker; Andy Itsara; Zhaoshi Jiang; Karen Buysse; Shuwen Huang; Viv Maloney; John A. Crolla; Diana Baralle; Amanda L. Collins; Catherine L. Mercer; Koenraad K. Norga; Thomy de Ravel; Koenraad Devriendt; Ernie M.H.F. Bongers; Nicole de Leeuw; William Reardon; Stefania Gimelli; Frédérique Béna; Raoul C. M. Hennekam; Alison Male; Lorraine Gaunt; Jill Clayton-Smith; Ingrid Simonic; Soo Mi Park; Sarju G. Mehta; Serena Nik-Zainal; C. Geoffrey Woods; Helen V. Firth

BACKGROUND Duplications and deletions in the human genome can cause disease or predispose persons to disease. Advances in technologies to detect these changes allow for the routine identification of submicroscopic imbalances in large numbers of patients. METHODS We tested for the presence of microdeletions and microduplications at a specific region of chromosome 1q21.1 in two groups of patients with unexplained mental retardation, autism, or congenital anomalies and in unaffected persons. RESULTS We identified 25 persons with a recurrent 1.35-Mb deletion within 1q21.1 from screening 5218 patients. The microdeletions had arisen de novo in eight patients, were inherited from a mildly affected parent in three patients, were inherited from an apparently unaffected parent in six patients, and were of unknown inheritance in eight patients. The deletion was absent in a series of 4737 control persons (P=1.1x10(-7)). We found considerable variability in the level of phenotypic expression of the microdeletion; phenotypes included mild-to-moderate mental retardation, microcephaly, cardiac abnormalities, and cataracts. The reciprocal duplication was enriched in nine children with mental retardation or autism spectrum disorder and other variable features (P=0.02). We identified three deletions and three duplications of the 1q21.1 region in an independent sample of 788 patients with mental retardation and congenital anomalies. CONCLUSIONS We have identified recurrent molecular lesions that elude syndromic classification and whose disease manifestations must be considered in a broader context of development as opposed to being assigned to a specific disease. Clinical diagnosis in patients with these lesions may be most readily achieved on the basis of genotype rather than phenotype.


Circulation | 2012

Very Late Coronary Stent Thrombosis of a Newer-Generation Everolimus-Eluting Stent Compared With Early-Generation Drug-Eluting Stents A Prospective Cohort Study

Lorenz Räber; Michael Magro; Giulio G. Stefanini; Bindu Kalesan; Ron T. van Domburg; Yoshinobu Onuma; Peter Wenaweser; Joost Daemen; Bernhard Meier; Peter Jüni; Patrick W. Serruys; Stephan Windecker

Background— Early-generation drug-eluting stents releasing sirolimus (SES) or paclitaxel (PES) are associated with increased risk of very late stent thrombosis occurring >1 year after stent implantation. It is unknown whether the risk of very late stent thrombosis persists with newer-generation everolimus-eluting stents (EES). Methods and Results— We assessed the risk of stent thrombosis in a cohort of 12 339 patients with unrestricted use of drug-eluting stents (3819 SES, 4308 PES, 4212 EES). Results are incidence rates per 100 person-years after inverse probability of treatment weighting to adjust for group differences. During follow-up of up to 4 years, the overall incidence rate of definite stent thrombosis was lower with EES (1.4 per 100 person-years) compared with SES (2.9; hazard ratio, 0.41; 95% confidence interval, 0.27–0.62; P<0.0001) and PES (4.4; hazard ratio, 0.33; 95% confidence interval, 0.23–0.48; P<0.0001). The incidence rate per 100 person-years of early (0–30 days), late (31 days–1 year), and very late stent thrombosis amounted to 0.6, 0.1, and 0.6 among EES-treated patients; 1.0, 0.3, and 1.6 among SES-treated patients; and 1.3, 0.7, and 2.4 among PES-treated patients. Differences in favor of EES were most pronounced beyond 1 year, with a hazard ratio of 0.33 (EES versus SES; P=0.006) and 0.34 (EES versus PES; P<0.0001). There was a lower risk of cardiac death or myocardial with EES compared with PES (hazard ratio, 0.65; 95% confidence interval, 0.56–0.75; P<0.0001), which was directly related to the lower risk of stent thrombosis–associated events (EES versus PES: hazard ratio, 0.36; 95% confidence interval, 0.23–0.57). Conclusion— Current treatment with EES is associated with a lower risk of very late stent thrombosis compared with early-generation drug-eluting stents.


JAMA | 2012

Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction: the COMFORTABLE AMI randomized trial

Lorenz Räber; Henning Kelbæk; Miodrag Ostojic; Andreas Baumbach; Dik Heg; David Tüller; Clemens von Birgelen; Marco Roffi; Aris Moschovitis; Ahmed A. Khattab; Peter Wenaweser; Robert F. Bonvini; Giovanni Pedrazzini; Ran Kornowski; Klaus Weber; Sven Trelle; Thomas F. Lüscher; Masanori Taniwaki; Christian M. Matter; Bernhard Meier; Peter Jüni; Stephan Windecker

CONTEXT The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). OBJECTIVE To compare stents eluting biolimus from a biodegradable polymer with bare-metal stents in primary PCI. DESIGN, SETTING, AND PATIENTS A prospective, randomized, single-blinded, controlled trial of 1161 patients presenting with STEMI at 11 sites in Europe and Israel between September 19, 2009, and January 25, 2011. Clinical follow-up was performed at 1 and 12 months. INTERVENTION Patients were randomized 1:1 to receive the biolimus-eluting stent (n = 575) or the bare-metal stent (n = 582). MAIN OUTCOME MEASURES Primary end point was the rate of major adverse cardiac events, a composite of cardiac death, target vessel-related reinfarction, and ischemia-driven target-lesion revascularization at 1 year. RESULTS Major adverse cardiac events at 1 year occurred in 24 patients (4.3%) receiving biolimus-eluting stents with biodegradable polymer and 49 patients (8.7%) receiving bare-metal stents (hazard ratio [HR], 0.49; 95% CI, 0.30-0.80; P = .004). The difference was driven by a lower risk of target vessel-related reinfarction (3 [0.5%] vs 15 [2.7%]; HR, 0.20; 95% CI, 0.06-0.69; P = .01) and ischemia-driven target-lesion revascularization (9 [1.6%] vs 32 [5.7%]; HR, 0.28; 95% CI, 0.13-0.59; P < .001) in patients receiving biolimus-eluting stents compared with those receiving bare-metal stents. Rates of cardiac death were not significantly different (16 [2.9%] vs 20 [3.5%], P = .53). Definite stent thrombosis occurred in 5 patients (0.9%) treated with biolimus-eluting stents and 12 patients (2.1%; HR, 0.42; 95% CI, 0.15-1.19; P = .10) treated with bare-metal stents. CONCLUSION Compared with a bare-metal stent, the use of biolimus-eluting stents with a biodegradable polymer resulted in a lower rate of the composite of major adverse cardiac events at 1 year among patients with STEMI undergoing primary PCI. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00962416.


Circulation | 2011

Five-Year Clinical and Angiographic Outcomes of a Randomized Comparison of Sirolimus-Eluting and Paclitaxel-Eluting Stents Results of the Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization LATE Trial

Lorenz Räber; Lea Wohlwend; Mathias Wigger; Mario Togni; Simon Wandel; Peter Wenaweser; Stéphane Cook; Aris Moschovitis; Rolf Vogel; Bindu Kalesan; Christian Seiler; Franz R. Eberli; Thomas F. Lüscher; Bernhard Meier; Peter Jüni; Stephan Windecker

Background— Long-term comparative data of first-generation drug-eluting stents are scarce. We investigated clinical and angiographic outcomes of sirolimus-eluting (SES) and paclitaxel-eluting stents (PES) at 5 years as part of the Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization (SIRTAX) LATE study. Methods and Results— A total of 1012 patients were randomly assigned to SES or PES. Repeat angiography was completed in 444 of 1012 patients (43.8%) at 5 years. Major adverse cardiac events occurred in 19.7% of SES- and 21.4% of PES-treated patients (hazard ratio, 0.89; 95% confidence interval, 0.68 to 1.17; P=0.39) at 5 years. There were no differences between SES and PES in terms of cardiac death (5.8% versus 5.7%; P=0.35), myocardial infarction (6.6% versus 6.9%; P=0.51), and target lesion revascularization (13.1% versus 15.1%; P=0.29). Between 1 and 5 years, the annual rate of target lesion revascularization was 2.0% (95% confidence interval, 1.4% to 2.6%) for SES and 1.4% (95% confidence interval, 0.9% to 2.0%) for PES. Among patients undergoing paired angiography at 8 months and 5 years, delayed lumen loss amounted to 0.37±0.73 mm for SES and 0.29±0.59 mm for PES (P=0.32). The overall rate of definite stent thrombosis was 4.6% for SES and 4.1% for PES (P=0.74), and very late definite stent thrombosis occurred at an annual rate of 0.65% (95% confidence interval, 0.40% to 0.90%). Conclusions— Long-term follow-up of first-generation drug-eluting stents shows no significant differences in clinical and angiographic outcomes between SES and PES. The continuous increase in late lumen loss in conjunction with the ongoing risk of very late stent thrombosis suggests that vascular healing remains incomplete up to 5 years after implantation of first-generation drug-eluting stents. Clinical Trial Registration— http://www.clinicaltrials.gov. Unique identifier: NCT00297661.


European Heart Journal | 2016

Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction: results of the randomized ABSORB ST-segment elevation myocardial infarction-TROFI II trial.

Manel Sabaté; Stephan Windecker; Andrés Iñiguez; Lisette Okkels-Jensen; Angel Cequier; Salvatore Brugaletta; Sjoerd H. Hofma; Lorenz Räber; E.H. Christiansen; Maarten J. Suttorp; Thomas Pilgrim; Gerrit Anne van Es; Yohei Sotomi; Hector M. Garcia-Garcia; Yoshinobu Onuma; Patrick W. Serruys

Abstract Aims Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential to overcome these limitations owing to restoration of native vessel lumen and physiology at long term. The purpose of this randomized trial was to compare the arterial healing response at short term, as a surrogate for safety and efficacy, between the Absorb and the metallic everolimus-eluting stent (EES) in patients with STEMI. Methods and results ABSORB-STEMI TROFI II was a multicentre, single-blind, non-inferiority, randomized controlled trial. Patients with STEMI who underwent primary percutaneous coronary intervention were randomly allocated 1:1 to treatment with the Absorb or EES. The primary endpoint was the 6-month optical frequency domain imaging healing score (HS) based on the presence of uncovered and/or malapposed stent struts and intraluminal filling defects. Main secondary endpoint included the device-oriented composite endpoint (DOCE) according to the Academic Research Consortium definition. Between 06 January 2014 and 21 September 2014, 191 patients (Absorb [n = 95] or EES [n = 96]; mean age 58.6 years old; 17.8% females) were enrolled at eight centres. At 6 months, HS was lower in the Absorb arm when compared with EES arm [1.74 (2.39) vs. 2.80 (4.44); difference (90% CI) −1.06 (−1.96, −0.16); Pnon-inferiority <0.001]. Device-oriented composite endpoint was also comparably low between groups (1.1% Absorb vs. 0% EES). One case of definite subacute stent thrombosis occurred in the Absorb arm (1.1% vs. 0% EES; P = ns). Conclusion Stenting of culprit lesions with Absorb in the setting of STEMI resulted in a nearly complete arterial healing which was comparable with that of metallic EES at 6 months. These findings provide the basis for further exploration in clinically oriented outcome trials.


Circulation | 2012

Long-Term Propensity Score–Matched Comparison of Percutaneous Closure of Patent Foramen Ovale With Medical Treatment After Paradoxical Embolism

Andreas Wahl; Peter Jüni; Marie-Luise Mono; Bindu Kalesan; Fabien Praz; Laura Geister; Lorenz Räber; Krassen Nedeltchev; Heinrich P. Mattle; Stephan Windecker; Bernhard Meier

Background— Patients with ischemic stroke or transient ischemic attack presumably related to patent foramen ovale (PFO) are at risk for recurrent cerebrovascular events. Differences in long-term clinical outcome were investigated among patients with percutaneous PFO closure and those who received medical treatment. Methods and Results— Between 1994 and 2000, 308 consecutive patients with cerebrovascular events presumably related to PFO underwent either percutaneous PFO closure (150 patients) or medical treatment (158 patients). Patients were followed up prospectively for up to 15 years. Seven patients were lost during follow-up. The primary outcome was a composite of stroke, transient ischemic attack, or peripheral embolism. We analyzed 103 propensity score–matched pairs of patients who underwent percutaneous PFO closure or medical treatment. At a median follow-up of 9 years, the primary composite outcome occurred in 11 patients slated to PFO closure (11%) and 22 patients slated to medical treatment (21%; hazard ratio=0.43; 95% confidence interval=0.20–0.94; P=0.033). The treatment effect was driven by a decrease in the risk of transient ischemic attack of 5% versus 14%, respectively (hazard ratio=0.31; 95% confidence interval=0.10–0.94; P=0.039). The risk of all-cause (6% in both groups) and cardiovascular (3% in both groups) mortality appeared to be identical. Conclusion— In this long-term observational, propensity score–matched study, percutaneous PFO closure was more effective than medical treatment for the secondary prevention of recurrent cerebrovascular events among patients with PFO-related transient ischemic attack or stroke.


Circulation | 2011

Five-Year Clinical and Angiographic Outcomes of a Randomized Comparison of Sirolimus-Eluting and Paclitaxel-Eluting Stents

Lorenz Räber; Lea Wohlwend; Mathias Wigger; Mario Togni; Simon Wandel; Peter Wenaweser; Stéphane Cook; Aris Moschovitis; Rolf Vogel; Bindu Kalesan; Christian Seiler; Franz R. Eberli; Thomas F. Lüscher; Bernhard Meier; Peter Jüni; Stephan Windecker

Background— Long-term comparative data of first-generation drug-eluting stents are scarce. We investigated clinical and angiographic outcomes of sirolimus-eluting (SES) and paclitaxel-eluting stents (PES) at 5 years as part of the Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization (SIRTAX) LATE study. Methods and Results— A total of 1012 patients were randomly assigned to SES or PES. Repeat angiography was completed in 444 of 1012 patients (43.8%) at 5 years. Major adverse cardiac events occurred in 19.7% of SES- and 21.4% of PES-treated patients (hazard ratio, 0.89; 95% confidence interval, 0.68 to 1.17; P=0.39) at 5 years. There were no differences between SES and PES in terms of cardiac death (5.8% versus 5.7%; P=0.35), myocardial infarction (6.6% versus 6.9%; P=0.51), and target lesion revascularization (13.1% versus 15.1%; P=0.29). Between 1 and 5 years, the annual rate of target lesion revascularization was 2.0% (95% confidence interval, 1.4% to 2.6%) for SES and 1.4% (95% confidence interval, 0.9% to 2.0%) for PES. Among patients undergoing paired angiography at 8 months and 5 years, delayed lumen loss amounted to 0.37±0.73 mm for SES and 0.29±0.59 mm for PES (P=0.32). The overall rate of definite stent thrombosis was 4.6% for SES and 4.1% for PES (P=0.74), and very late definite stent thrombosis occurred at an annual rate of 0.65% (95% confidence interval, 0.40% to 0.90%). Conclusions— Long-term follow-up of first-generation drug-eluting stents shows no significant differences in clinical and angiographic outcomes between SES and PES. The continuous increase in late lumen loss in conjunction with the ongoing risk of very late stent thrombosis suggests that vascular healing remains incomplete up to 5 years after implantation of first-generation drug-eluting stents. Clinical Trial Registration— http://www.clinicaltrials.gov. Unique identifier: NCT00297661.


The Lancet | 2017

Derivation and validation of the predicting bleeding complications in patients undergoing stent implantation and subsequent dual antiplatelet therapy (PRECISE-DAPT) score: a pooled analysis of individual-patient datasets from clinical trials

Francesco Costa; David van Klaveren; Stefan James; Dik Heg; Lorenz Räber; Fausto Feres; Thomas Pilgrim; Myeong Ki Hong; Hyo Soo Kim; Antonio Colombo; Philippe Gabriel Steg; Thomas Zanchin; Tullio Palmerini; Lars Wallentin; Deepak L. Bhatt; Gregg W. Stone; Stephan Windecker; Ewout W. Steyerberg; Marco Valgimigli

BACKGROUND Dual antiplatelet therapy (DAPT) with aspirin plus a P2Y12 inhibitor prevents ischaemic events after coronary stenting, but increases bleeding. Guidelines support weighting bleeding risk before the selection of treatment duration, but no standardised tool exists for this purpose. METHODS A total of 14 963 patients treated with DAPT after coronary stenting-largely consisting of aspirin and clopidogrel and without indication to oral anticoagulation-were pooled at a single-patient level from eight multicentre randomised clinical trials with independent adjudication of events. Using Cox proportional hazards regression, we identified predictors of out-of-hospital Thrombosis in Myocardial Infarction (TIMI) major or minor bleeding stratified by trial, and developed a numerical bleeding risk score. The predictive performance of the novel score was assessed in the derivation cohort and validated in patients treated with percutaneous coronary intervention from the PLATelet inhibition and patient Outcomes (PLATO) trial (n=8595) and BernPCI registry (n=6172). The novel score was assessed within patients randomised to different DAPT durations (n=10 081) to identify the effect on bleeding and ischaemia of a long (12-24 months) or short (3-6 months) treatment in relation to baseline bleeding risk. FINDINGS The PRECISE-DAPT score (age, creatinine clearance, haemoglobin, white-blood-cell count, and previous spontaneous bleeding) showed a c-index for out-of-hospital TIMI major or minor bleeding of 0·73 (95% CI 0·61-0·85) in the derivation cohort, and 0·70 (0·65-0·74) in the PLATO trial validation cohort and 0·66 (0·61-0·71) in the BernPCI registry validation cohort. A longer DAPT duration significantly increased bleeding in patients at high risk (score ≥25), but not in those with lower risk profiles (pinteraction=0·007), and exerted a significant ischaemic benefit only in this latter group. INTERPRETATION The PRECISE-DAPT score is a simple five-item risk score, which provides a standardised tool for the prediction of out-of-hospital bleeding during DAPT. In the context of a comprehensive clinical evaluation process, this tool can support clinical decision making for treatment duration. FUNDING None.


Journal of the American College of Cardiology | 2011

Long-Term Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents for Coronary Revascularization

Lorenz Räber; Peter Jüni; Eveline Nüesch; Bindu Kalesan; Peter Wenaweser; Aris Moschovitis; Ahmed A. Khattab; Maryam Bahlo; Mario Togni; Stéphane Cook; Rolf Vogel; C Seiler; Bernhard Meier; Stephan Windecker

OBJECTIVES This study sought to compare the unrestricted use of everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing percutaneous coronary intervention. BACKGROUND It is unclear whether there are differences in safety and efficacy between EES and SES during long-term follow-up. METHODS Using propensity score matching, clinical outcome was compared among 1,342 propensity score-matched pairs of patients treated with EES and SES. The primary outcome was a composite of death, MI, and target vessel revascularization. RESULTS The median follow-up was 1.5 years with a maximum of 3 years. The primary outcome occurred in 14.9% of EES- and 18.0% of SES-treated patients up to 3 years (hazard ratio [HR]: 0.83, 95% confidence interval [CI]: 0.68 to 1.00, p = 0.056). All-cause mortality (6.0% vs. 6.5%, HR: 0.92, 95% CI: 0.68 to 1.25, p = 0.59) was similar, risks of myocardial infarction (MI) (3.3% vs. 5.0%, HR: 0.62, 95% CI: 0.42 to 0.92, p = 0.017), and target vessel revascularization (7.0% vs. 9.6%, HR: 0.75, 95% CI: 0.57 to 0.99, p = 0.039) were lower with EES than SES. Definite stent thrombosis (ST) (HR: 0.30, 95% CI: 0.12 to 0.75, p = 0.01) was less frequent among patients treated with EES. The reduced rate of MI with EES was explained in part by the lower risk of definite ST and the corresponding decrease in events associated with ST (HR: 0.25, 95% CI: 0.08 to 0.75, p = 0.013). CONCLUSIONS The unrestricted use of EES appears to be associated with improved clinical long-term outcome compared with SES. Differences in favor of EES are driven in part by a lower risk of MI associated with ST.

Collaboration


Dive into the Lorenz Räber's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bernhard Meier

University Hospital of Bern

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge