Luceil B. North
Baylor College of Medicine
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Luceil B. North.
Chest | 1978
Samuel F. Boushy; Luceil B. North; Agust H. Helgason
Eighteen patients with pleural effusion were examined. Nine patients had malignant neoplasm and in one the pleura was diffusely involved. Nine patients had pleural effusion of inflammatory origin. One of these was due to tuberculosis, one to trichinosis and the other seven were nonspecific. Thoracotomy in three of these seven failed to add additional information. All patients tolerated pneumothorax well with equilibration of pleural space and atmospheric pressure.
Medical Physics | 1977
Benjamin R. Archer; Sharon A. Glaze; Luceil B. North; Stewart C. Bushong
Each section of the Alderson Rando phantom contains a tissue-equivalent plastic coating layer approximately 2 mm thick, applied to both faces. This compensates for material removed in the sawing process. Conventional use of thermoluminescent dosimeters positions them totally or partially within the coating layer. Analysis shows that, in the lung region, dosimeters placed in this layer received a dose averaging 39% lower than those placed at midsection. Where bony structures interfere, some dosimeters in the coating layer received an 18% higher dose than those at midsection. Therefore, positioning dosimeters at the center of a section is recommended.
Radiology | 1979
Benjamin R. Archer; Randall C. Whitmore; Luceil B. North; Stewart C. Bushong
The dose to active bone marrow resulting from anteroposterior (AP) and posteroanterior (PA) chest examinations was estimated using an Alderson Rando phantom and extruded lithium fluoride dosimeters. The AP projections resulted in a mean marrow dose range of 1.9-2.6 mrad (0.019-0.026 mGy) as compared to doses for PA projections of 3.4-3.8 mrad (0.034-0.038 mGy) for optimally diagnostic exposure taken at 70, 90, and 120 kVp.
Radiation Research | 1976
Naresh Prasad; Stewart C. Bushong; Luceil B. North; John Thornby
Groups of male opossum (Didelphis virginiana) at 6 months of age were exposed to 350, 500, 550, 600, 650, 700, and 750 rad of whole-body60 Co radiation at a midline dose rate of 125 rad/min. The 30...
Chest | 1971
Samuel F. Boushy; Donal M. Billig; Luceil B. North; August H. Helgason
The American review of respiratory disease | 2015
Samuel F. Boushy; Howard K. Thompson; Luceil B. North; Alan R. Beale; T. R. Snow
The American review of respiratory disease | 2015
Samuel F. Boushy; Michel H. Aboumrad; Luceil B. North; Agust H. Helgason
The American review of respiratory disease | 1971
Samuel F. Boushy; August H. Helgason; Luceil B. North
Chest | 1973
S. F. Boushy; Luceil B. North
Cancer Research | 1977
Naresh Prasad; Rupi Prasad; John Thornby; Stewart C. Bushong; Luceil B. North; James E. Harrell