Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Luis Gustavo Oliveira de Vasconcellos is active.

Publication


Featured researches published by Luis Gustavo Oliveira de Vasconcellos.


Journal of Applied Oral Science | 2006

Histomorphometric analysis of pure titanium implants with porous surface versus rough surface

Aline Scalone Brentel; Luana Marotta Reis de Vasconcellos; Marize Varella de Oliveira; Mario Lima de Alencastro Graça; Luis Gustavo Oliveira de Vasconcellos; Carlos Alberto Alves Cairo; Yasmin Rodarte Carvalho

The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 weeks after surgery and fragments of the tibiae containing the implants were submitted to histological and histomorphometric analyses to evaluate new bone formation at the implant-bone interface. Means (%) of bone neoformation obtained in the histomorphometric analysis were compared by Students t-test for paired samples at 5% significance level.. The results of the histological analysis showed that osseointegration occurred for both types of implants with similar quality of bone tissue. The histomorphometric analysis revealed means of new bone formation at implant-bone interface of 79.69 ± 1.00% and 65.05 ± 1.23% for the porous- and rough-surface implants, respectively. Statistically significant difference was observed between the two types of implants with respect to the amount new bone formation (p<0.05). In conclusion, the porous-surface implants contributed to the osseointegration because they provide a larger contact area at implant-bone interface.


Materials Research-ibero-american Journal of Materials | 2008

Porous Titanium Scaffolds Produced by Powder Metallurgy for Biomedical Applications

Luana Marotta Reis de Vasconcellos; Marize Varella de Oliveira; Mario Lima de Alencastro Graça; Luis Gustavo Oliveira de Vasconcellos; Yasmin Rodarte Carvalho; Carlos Alberto Alves Cairo

Porous titanium scaffolds are promising materials for biomedical applications such as prosthetic anchors, fillers and bone reconstruction. This study evaluated the bone/titanium interface of scaffolds with interconnected pores prepared by powder metallurgy, using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). Porous scaffolds and dense samples were implanted in the tibia of rabbits, which were subsequently killed 1, 4, and 8 weeks after surgery. Initial bone neoformation was observed one week after implantation. Bone ingrowth in pores and the Ca/P ratio at the interface were remarkably enhanced at 4 and 8 weeks. The results showed that the interconnected pores of the titanium scaffolds promoted bone ingrowth, which increased over time. The powder metallurgy technique thus proved effective in producing porous scaffolds and dense titanium for biomedical applications, allowing for adequate control of pore size and porosity and promoting bone ingrowth.


Journal of Prosthodontics | 2010

Opaque Layer Firing Temperature and Aging Effect on the Flexural Strength of Ceramic Fused to Cobalt-Chromium Alloy

Luis Gustavo Oliveira de Vasconcellos; Leonardo Buso; Geraldo Henrique Leão Lombardo; Rodrigo Othávio de Assunção e Souza; Lafayette Nogueira Junior; Marco Antonio Bottino; Mutlu Özcan

PURPOSE To evaluate the effect of the opaque layer firing temperature and mechanical and thermal cycling on the flexural strength of a ceramic fused to commercial cobalt-chromium alloy (Co-Cr). The hypotheses were that higher opaque layer temperatures increase the metal/ceramic bond strength and that aging reduces the bond strength. MATERIALS AND METHODS Metallic frameworks (25 x 3 x 0.5 mm(3); ISO 9693) (N = 60) were cast in Co-Cr and airborne-particle abraded (Al(2)O(3): 150 mum) at the central area of the frameworks (8 x 3 mm(2)) and divided into three groups (N = 20), according to the opaque layer firing temperature: Gr1 (control)-900 degrees C; Gr2-950 degrees C; Gr3-1000 degrees C. The opaque ceramic (Opaque, Vita Zahnfabrick, Bad Säckingen, Germany) was applied, and the glass ceramic (Vita Omega 900, Vita Zahnfabrick) was fired onto it (thickness: 1 mm). While half the specimens from each group were randomly tested without aging (water storage: 37 degrees C/24 hours), the other half were mechanically loaded (20,000 cycles; 50 N load; distilled water at 37 degrees C) and thermocycled (3000 cycles; 5 degrees C to 55 degrees C, dwell time: 30 seconds). After the flexural strength test, failure types were noted. The data were analyzed using 2-way ANOVA and Tukeys test (alpha= 0.05). RESULTS Gr2 (19.41 +/- 5.5 N) and Gr3 (20.6 +/- 5 N) presented higher values than Gr1 (13.3 +/- 1.6 N) (p= 0.001). Mechanical and thermal cycling did not significantly influence the mean flexural strength values (p > 0.05). Increasing the opaque layer firing temperature improved the flexural bond strength values (p < 0.05). The hypotheses were partially accepted. CONCLUSION Increasing of the opaque layer firing temperature improved the flexural bond strength between ceramic fused to Co-Cr alloy.


Lasers in Medical Science | 2014

Healing of normal and osteopenic bone with titanium implant and low-level laser therapy (GaAlAs): a histomorphometric study in rats

Luana Marotta Reis de Vasconcellos; Mary Anne Moreira Bárbara; Camila Porto Deco; Juliana Campos Junqueira; Renata Falchete do Prado; Ana Lia Anbinder; Luis Gustavo Oliveira de Vasconcellos; Carlos Alberto Alves Cairo; Yasmin Rodarte Carvalho

The study investigates the influence of low-level laser therapy (LLLT) on bone healing in the femur of osteopenic and normal rats with titanium implants. Ovariectomy and control group were randomly submitted to LLLT, which was applied by gallium-aluminum-arsenium (GaAlAs) laser at the surgical site before and after placing the implant, for seven times. Histomorphometric and statistical analysis were performed. Most irradiated groups showed higher values than the nonirradiated groups. The GaAlAs infrared diode laser may improve the osseointegration process in osteopenic and normal bone, particularly based on its effects in the initial phase of bone formation.


Journal of Prosthodontics | 2011

Effect of Airborne-Particle Abrasion and Mechanico-Thermal Cycling on the Flexural Strength of Glass Ceramic Fused to Gold or Cobalt-Chromium Alloy

Luis Gustavo Oliveira de Vasconcellos; Lucas Hian da Silva; Luana Marotta Reis de Vasconcellos; Ivan Balducci; Fernando Eidi Takahashi; Marco Antonio Bottino

PURPOSE To evaluate the effect of airborne-particle abrasion and mechanico-thermal cycling on the flexural strength of a ceramic fused to cobalt-chromium alloy or gold alloy. MATERIALS AND METHODS Metallic bars (n = 120) were made (25 mm × 3 mm × 0.5 mm): 60 with gold alloy and 60 with Co-Cr. At the central area of the bars (8 mm × 3 mm), a layer of opaque ceramic and then two layers of glass ceramic (Vita VM13, Vita Zahnfabrick) were fired onto it (thickness: 1 mm). Ten specimens from each alloy group were randomly allocated to a surface treatment [(tungsten bur or air-particle abrasion (APA) with Al(2) O(3) at 10 mm or 20 mm away)] and mechanico-thermal cycling (no cycling or mechanically loaded 20,000 cycles; 10 N distilled water at 37°C and then thermocycled 3000 cycles; 5°C to 55°C, dwell time 30 seconds) combination. Those specimens that did not undergo mechanico-thermal cycling were stored in water (37°C) for 24 hours. Bond strength was measured using a three-point bend test, according to ISO 9693. After the flexural strength test, failure types were noted. The data were analyzed using three factor-ANOVA and Tukeys test (α= 0.05). RESULTS There were no significant differences between the flexural bond strength of gold and Co-Cr groups (42.64 ± 8.25 and 43.39 ± 10.89 MPa, respectively). APA 10 and 20 mm away surface treatment (45.86 ± 9.31 and 46.38 ± 8.89 MPa, respectively) had similar mean flexural strength values, and both had significantly higher bond strength than tungsten bur treatment (36.81 ± 7.60 MPa). Mechanico-thermal cycling decreased the mean flexural strength values significantly for all six alloy-surface treatment combinations tested when compared to the control groups. The failure type was adhesive in the metal/ceramic interface for specimens surface treated only with the tungsten bur, and mixed for specimens surface treated with APA 10 and 20 mm. CONCLUSIONS Considering the levels adopted in this study, the alloy did not affect the bond strength; APA with Al(2) O(3) at 10 and 20 mm improved the flexural bond strength between ceramics and alloys used, and the mechanico-thermal cycling of metal-ceramic specimens resulted in a decrease of bond strength.


Archive | 2012

Porous Titanium by Powder Metallurgy for Biomedical Application: Characterization, Cell Citotoxity and in vivo Tests of Osseointegration

Luana Marotta Reis de Vasconcellos; Yasmin Rodarte Carvalho; Renata Falchete do Prado; Luis Gustavo Oliveira de Vasconcellos; Mario Lima de Alencastro Graça; Carlos Alberto Alves Cairo

© 2012 de Vasconcellos, licensee InTech. This is an open access chapter distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Porous Titanium by Powder Metallurgy for Biomedical Application: Characterization, Cell Citotoxity and in vivo Tests of Osseointegration


Journal of Craniofacial Surgery | 2013

Microstrain around dental implants supporting fixed partial prostheses under axial and non-axial loading conditions, in vitro strain gauge analysis.

Luis Gustavo Oliveira de Vasconcellos; Renato Sussumu Nishioka; Luana Marotta Reis de Vasconcellos; Ivan Balducci; Alberto Noriyuki Kojima

Abstract The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non–axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N·cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N·cm torque, and axial and non–axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 &mgr;[Latin Small Letter Open E]) and point A (axial) generating the smallest microstrain (208.93 &mgr;[Latin Small Letter Open E]). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non–axial loading conditions, although loading location did influence this magnitude.


International Journal of Oral & Maxillofacial Implants | 2013

In vivo osteogenesis and in vitro Streptococcus mutans adherence: porous-surfaced cylindrical implants vs rough-surfaced threaded implants.

Renata Falchete do Prado; Luis Gustavo Oliveira de Vasconcellos; Luana Marotta Reis de Vasconcellos; Carlos Alberto Alves Cairo; Daniel de Oliveira Leite; Alessandra dos Santos; Antonio Olavo Cardoso Jorge; Rogério de Lima Romeiro; Ivan Balducci; Yasmin Rodarte Carvalho

PURPOSE To analyze and compare bone apposition at the interface of commercially available rough-surfaced, threaded implants with porous-surfaced, cylindrical implants after several healing periods in a rabbit model. In addition, the study aimed to elucidate the influence of the implant surface configuration on Streptococcus mutans adherence. MATERIALS AND METHODS Using a powder metallurgy technique, a new method was developed to produce titanium implants with a dense core and porous surface to increase bone-implant contact (BIC). Sixty implants were placed in 15 rabbits. In each rabbit, two experimental and two control implants were placed in the right or left tibia. The experimental implants were inserted under pressure into the surgical cavity, while the control implants were self-threaded. The rabbits were euthanized at 4, 8, and 12 weeks postinsertion for undecalcified histologic processing and morphometric evaluation of BIC. Additionally, 16 implants, eight experimental and eight control, were incubated with S. mutans to evaluate adherence for each type of implant. Analysis of variance with repeated measures and the Student t test were applied, respectively. RESULTS Histology showed intimate bone-implant interfaces without soft tissue intervention in both groups. Porous-surfaced cylindrical implants showed a higher BIC (72.41% ± 9.47%) than the rough-surfaced screw implants (61.23% ± 14.12%) (P = .013), while no significant difference in S. mutans adherence occurred (P = .351). The implant type effect was more pronounced in the 4-week healing period groups (P = .029). The percentage of BIC was similar throughout the healing periods (P = .333), but gradually increased over time. CONCLUSION Within the limitations of this study, the results suggest that the new implant design increased BIC without provoking greater S. mutans adherence.


PLOS ONE | 2018

In vitro and in vivo biological performance of porous Ti alloys prepared by powder metallurgy

Renata Falchete do Prado; Gabriela Campos Esteves; Evelyn Luzia de Souza Santos; Daiane Acácia Griti Bueno; Carlos Alberto Alves Cairo; Luis Gustavo Oliveira de Vasconcellos; Renata Silveira Sagnori; Fernanda Bastos Pereira Tessarin; Felipe Eduardo de Oliveira; Luciane Dias de Oliveira; Maria Fernanda Lima Villaça-Carvalho; Vinicius André Rodrigues Henriques; Yasmin Rodarte Carvalho; Luana Marotta Reis de Vasconcellos

Titanium (Ti) and Ti-6 Aluminium-4 Vanadium alloys are the most common materials in implants composition but β type alloys are promising biomaterials because they present better mechanical properties. Besides the composition of biomaterial, many factors influence the performance of the biomaterial. For example, porous surface may modify the functional cellular response and accelerate osseointegration. This paper presents in vitro and in vivo evaluations of powder metallurgy-processed porous samples composed by different titanium alloys and pure Ti, aiming to show their potential for biomedical applications. The porous surfaces samples were produced with different designs to in vitro and in vivo tests. Samples were characterized with scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and elastic modulus analyses. Osteogenic cells from newborn rat calvaria were plated on discs of different materials: G1—commercially pure Ti group (CpTi); G2—Ti-6Al-4V alloy; G3—Ti-13 Niobium-13 Zirconium alloy; G4—Ti-35 Niobium alloy; G5—Ti-35 Niobium-7 Zirconium-5 Tantalum alloy. Cell adhesion and viability, total protein content, alkaline phosphatase activity, mineralization nodules and gene expression (alkaline phosphatase, Runx-2, osteocalcin and osteopontin) were assessed. After 2 and 4 weeks of implantation in rabbit tibia, bone ingrowth was analyzed using micro-computed tomography (μCT). EDS analysis confirmed the material production of each group. Metallographic and SEM analysis revealed interconnected pores, with mean pore size of 99,5μm and mean porosity of 42%, without significant difference among the groups (p>0.05). The elastic modulus values did not exhibit difference among the groups (p>0.05). Experimental alloys demonstrated better results than CpTi and Ti-6Al-4V, in gene expression and cytokines analysis, especially in early experimental periods. In conclusion, our data suggests that the experimental alloys can be used for biomedical application since they contributed to excellent cellular behavior and osseointegration besides presenting lower elastic modulus.


Journal of Oral Implantology | 2015

Axial Loads on Implant-Supported Partial Fixed Prostheses for External and Internal Hex Connections and Machined and Plastic Copings: Strain Gauge Analysis

Luis Gustavo Oliveira de Vasconcellos; Alberto Noriyuki Kojima; Renato Sussumu Nishioka; Luana Marotta Reis de Vasconcellos; Ivan Balducci

The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (με). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (α = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.

Collaboration


Dive into the Luis Gustavo Oliveira de Vasconcellos's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ivan Balducci

Sao Paulo State University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge