Lx Wang
Royal Perth Hospital
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Lx Wang.
Pacing and Clinical Electrophysiology | 1998
Lx Wang; Cy Li; Ac Yong; D Kilpatrick
A technique of fast Fourier transform analysis has been used to derive mean ventricular fibrillation (VF) intervals, and to confirm that these VF intervals predict ventricular refractory periods. Twenty episodes of VF were induced by a rapid ventricular pacing in 12 sheep. VF activations in a 10‐second period were simultaneously acquired from 64 epicardial sites with an electrode sock. The VF electrograms were analyzed by a fast Fourier transform analysis. The dominant peak frequency of the VF spectrum in each epicardial site was converted into milliseconds and served as a mean VF interval. The dominant peak frequency of VF electrograms ranged from 8.1 to 11.5 Hz, and the corresponding mean VF intervals were 87 to 124 ms. In five sheep, the mean VF intervals and the effective refractory periods were determined by the extrastimulus technique obtained from 29 epicardial sites. There was a very good correlation between the two parameters when the effective refractory periods were determined at a basic cycle length of 300 ms (r = 0.89, P < 0.001) and 400 ms (r = 0.87, P < 0.001), respectively. VF was induced twice in eight sheep. The maximum difference in the mean VF intervals between the two VF episodes in the same sheep was 3 ms (P > 0.05). In conclusion, mean VF intervals determined by the fast Fourier transform analysis have a good reproducibility and a good correlation with ventricular refractory periods measured by the classic extrastimulus technique. The mean VF intervals could serve as an index of ventricular refractoriness.
International Journal of Cardiology | 1997
Lx Wang; M. J. E. Davis
Periods of failure of ventricular pacing and atrial sensing were discovered on Holter recording in a 10-year-old boy 4 years after the implantation of a dual-chamber pacemaker with endocardial bipolar leads brought out through the right atrial wall. The old generator was explanted and the old leads tested. There was considerable atrial oversensing of an electrical artefact. The pacing threshold of ventricular lead was 1.8 V compared with 0.3 V 6 days post implantation. Post-operative lateral chest X-ray disclosed fractures of both atrial and ventricular leads at the approximate site of exit from the right atriotomy. Review of the preoperative lateral film showed that the fractures had been hidden by an ECG electrode.
The New Zealand Medical Journal | 1996
John K. French; Barbara F. Williams; Hamish Hart; K Woo; Lx Wang; J Grant; Christine Ingram; P Obrien; June Poole; N Sharpe; M. Williams; Harvey D. White
XVI World Congress of the International Society for Heart Research | 1998
D Kilpatrick; Lx Wang; Ac Yong
XIII World Congress of Cardiology | 1998
Lx Wang; D Kilpatrick; Ac Yong
46th Annual Scientific Meeting of the Cardiac Society of Australia and New Zealand | 1998
Lx Wang; Ac Yong; D Kilpatrick
46th Annual Scientific Meeting of the Cardiac Society of Australia and New Zealand | 1998
Lx Wang; Ac Yong; D Kilpatrick
Journal of the American College of Cardiology | 1997
Lx Wang
45th Annual Scientific Meeting of the Cardiac Society of Australia and New Zealand | 1997
Lx Wang; Ac Yong; D Kilpatrick
45th Annual Scientific Meeting of the Cardiac Society of Australia and New Zealand | 1997
Lx Wang; Cy Li; Ac Yong; D Kilpatrick