M. Asif Taqi
Emory University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by M. Asif Taqi.
Journal of NeuroInterventional Surgery | 2014
Osama O. Zaidat; Alicia C. Castonguay; Rishi Gupta; Chung Huan J Sun; Coleman O. Martin; William E. Holloway; Nils Mueller-Kronast; Joey D. English; Italo Linfante; Guilherme Dabus; Tim W. Malisch; Franklin A. Marden; Hormozd Bozorgchami; Andrew Xavier; A Rai; Michael T. Froehler; Aamir Badruddin; Thanh N. Nguyen; M. Asif Taqi; Michael G. Abraham; Vallabh Janardhan; Hashem Shaltoni; Roberta Novakovic; Albert J. Yoo; Alex Abou-Chebl; Peng R. Chen; Gavin W. Britz; Ritesh Kaushal; Ashish Nanda; Mohammad A. Issa
Background Limited post-marketing data exist on the use of the Solitaire FR device in clinical practice. The North American Solitaire Stent Retriever Acute Stroke (NASA) registry aimed to assess the real world performance of the Solitaire FR device in contrast with the results from the SWIFT (Solitaire with the Intention for Thrombectomy) and TREVO 2 (Trevo versus Merci retrievers for thrombectomy revascularization of large vessel occlusions in acute ischemic stroke) trials. Methods The investigator initiated NASA registry recruited North American sites to submit retrospective angiographic and clinical outcome data on consecutive acute ischemic stroke (AIS) patients treated with the Solitaire FR between March 2012 and February 2013. The primary outcome was a Thrombolysis in Myocardial Ischemia (TIMI) score of ≥2 or a Treatment in Cerebral Infarction (TICI) score of ≥2a. Secondary outcomes were 90 day modified Rankin Scale (mRS) score, mortality, and symptomatic intracranial hemorrhage. Results 354 patients underwent treatment for AIS using the Solitaire FR device in 24 centers. Mean time from onset to groin puncture was 363.4±239 min, mean fluoroscopy time was 32.9±25.7 min, and mean procedure time was 100.9±57.8 min. Recanalization outcome: TIMI ≥2 rate of 83.3% (315/354) and TICI ≥2a rate of 87.5% (310/354) compared with the operator reported TIMI ≥2 rate of 83% in SWIFT and TICI ≥2a rate of 85% in TREVO 2. Clinical outcome: 42% (132/315) of NASA patients demonstrated a 90 day mRS ≤2 compared with 37% (SWIFT) and 40% (TREVO 2). 90 day mortality was 30.2% (95/315) versus 17.2% (SWIFT) and 29% (TREVO 2). Conclusions The NASA registry demonstrated that the Solitaire FR device performance in clinical practice is comparable with the SWIFT and TREVO 2 trial results.
Journal of NeuroInterventional Surgery | 2016
Italo Linfante; Amy Starosciak; Gail Walker; Guilherme Dabus; Alicia C. Castonguay; Rishi Gupta; Chung Huan J Sun; Coleman O. Martin; William E. Holloway; Nils Mueller-Kronast; Joey D. English; Tim W. Malisch; Franklin A. Marden; Hormozd Bozorgchami; Andrew Xavier; A Rai; Michael T. Froehler; Aamir Badruddin; Thanh N. Nguyen; M. Asif Taqi; Michael G. Abraham; Vallabh Janardhan; Hashem Shaltoni; Roberta Novakovic; Albert J. Yoo; Alex Abou-Chebl; Peng R. Chen; Gavin W. Britz; Ritesh Kaushal; Ashish Nanda
Background Mechanical thrombectomy with stent-retrievers results in higher recanalization rates compared with previous devices. Despite successful recanalization rates (Thrombolysis in Cerebral Infarction (TICI) score ≥2b) of 70–83%, good outcomes by 90-day modified Rankin Scale (mRS) score ≤2 are achieved in only 40–55% of patients. We evaluated predictors of poor outcomes (mRS >2) despite successful recanalization (TICI ≥2b) in the North American Solitaire Stent Retriever Acute Stroke (NASA) registry. Methods Logistic regression was used to evaluate baseline characteristics and recanalization outcomes for association with 90-day mRS score of 0–2 (good outcome) vs 3–6 (poor outcome). Univariate tests were carried out for all factors. A multivariable model was developed based on backwards selection from the factors with at least marginal significance (p≤0.10) on univariate analysis with the retention criterion set at p≤0.05. The model was refit to minimize the number of cases excluded because of missing covariate values; the c-statistic was a measure of predictive power. Results Of 354 patients, 256 (72.3%) were recanalized successfully. Based on 234 recanalized patients evaluated for 90-day mRS score, 116 (49.6%) had poor outcomes. Univariate analysis identified an increased risk of poor outcome for age ≥80 years, occlusion site of internal carotid artery (ICA)/basilar artery, National Institute of Health Stroke Scale (NIHSS) score ≥18, history of diabetes mellitus, TICI 2b, use of rescue therapy, not using a balloon-guided catheter or intravenous tissue plasminogen activator (IV t-PA), and >30 min to recanalization (p≤0.05). In multivariable analysis, age ≥80 years, occlusion site ICA/basilar, initial NIHSS score ≥18, diabetes, absence of IV t-PA, ≥3 passes, and use of rescue therapy were significant independent predictors of poor 90-day outcome in a model with good predictive power (c-index=0.80). Conclusions Age, occlusion site, high NIHSS, diabetes, no IV t-PA, ≥3 passes, and use of rescue therapy are associated with poor 90-day outcome despite successful recanalization.
Stroke | 2014
Alicia C. Castonguay; Osama O. Zaidat; Roberta Novakovic; Thanh N. Nguyen; M. Asif Taqi; Rishi Gupta; Chung Huan J Sun; Coleman O. Martin; William E. Holloway; Nils Mueller-Kronast; Joey E. English; Italo Linfante; Guilherme Dabus; Tim W. Malisch; Franklin A. Marden; Hormozd Bozorgchami; Andrew Xavier; A Rai; Michael T. Froehler; Aamir Badruddin; Michael G. Abraham; Vallabh Janardhan; Hashem Shaltoni; Albert J. Yoo; Alex Abou-Chebl; Peng R. Chen; Gavin W. Britz; Ritesh Kaushal; Ashish Nanda; Mohammad A. Issa
Background and Purpose— The Solitaire With the Intention for Thrombectomy (SWIFT) and thrombectomy revascularization of large vessel occlusions in acute ischemic stroke (TREVO 2) trial results demonstrated improved recanalization rates with mechanical thrombectomy; however, outcomes in the elderly population remain poorly understood. Here, we report the effect of age on clinical and angiographic outcome within the North American Solitaire-FR Stent-Retriever Acute Stroke (NASA) Registry. Methods— The NASA Registry recruited sites to submit data on consecutive patients treated with Solitaire-FR. Influence of age on clinical and angiographic outcomes was assessed by dichotomizing the cohort into ⩽80 and >80 years of age. Results— Three hundred fifty-four patients underwent treatment in 24 centers; 276 patients were ⩽80 years and 78 were >80 years of age. Mean age in the ⩽80 and >80 cohorts was 62.2±13.2 and 85.2±3.8 years, respectively. Of patients >80 years, 27.3% had a 90-day modified Rankin Score ⩽2 versus 45.4% ⩽80 years (P=0.02). Mortality was 43.9% and 27.3% in the >80 and ⩽80 years cohorts, respectively (P=0.01). There was no significant difference in time to revascularization, revascularization success, or symptomatic intracranial hemorrhage between the groups. Multivariate analysis showed age >80 years as an independent predictor of poor clinical outcome and mortality. Within the >80 cohort, National Institutes of Health Stroke Scale (NIHSS), revascularization rate, rescue therapy use, and symptomatic intracranial hemorrhage were independent predictors of mortality. Conclusion— Greater than 80 years of age is predictive of poor clinical outcome and increased mortality compared with younger patients in the NASA registry. However, intravenous tissue-type plasminogen activator use, lower NIHSS, and shorter revascularization time are associated with better outcomes. Further studies are needed to understand the endovascular therapy role in this cohort compared with medical therapy.
Stroke | 2017
Nils Mueller-Kronast; Osama O. Zaidat; Michael T. Froehler; Reza Jahan; Mohammad Ali Aziz-Sultan; Richard Klucznik; Jeffrey L. Saver; Frank R. Hellinger; Dileep R. Yavagal; Tom L. Yao; David S. Liebeskind; Ashutosh P. Jadhav; Rishi Gupta; Ameer E. Hassan; Coleman O. Martin; Hormozd Bozorgchami; Ritesh Kaushal; Raul G. Nogueira; Ravi H. Gandhi; Eric C. Peterson; Shervin R. Dashti; Curtis A. Given; Brijesh P. Mehta; Vivek Deshmukh; Sidney Starkman; Italo Linfante; Scott H. McPherson; Peter Kvamme; Thomas Grobelny; Muhammad S Hussain
Background and Purpose— Mechanical thrombectomy with stent retrievers has become standard of care for treatment of acute ischemic stroke patients because of large vessel occlusion. The STRATIS registry (Systematic Evaluation of Patients Treated With Neurothrombectomy Devices for Acute Ischemic Stroke) aimed to assess whether similar process timelines, technical, and functional outcomes could be achieved in a large real world cohort as in the randomized trials. Methods— STRATIS was designed to prospectively enroll patients treated in the United States with a Solitaire Revascularization Device and Mindframe Capture Low Profile Revascularization Device within 8 hours from symptom onset. The STRATIS cohort was compared with the interventional cohort of a previously published SEER patient-level meta-analysis. Results— A total of 984 patients treated at 55 sites were analyzed. The mean National Institutes of Health Stroke Scale score was 17.3. Intravenous tissue-type plasminogen activator was administered in 64.0%. The median time from onset to arrival in the enrolling hospital, door to puncture, and puncture to reperfusion were 138, 72, and 36 minutes, respectively. The Core lab–adjudicated modified Thrombolysis in Cerebral Infarction ≥2b was achieved in 87.9% of patients. At 90 days, 56.5% achieved a modified Rankin Scale score of 0 to 2, all-cause mortality was 14.4%, and 1.4% suffered a symptomatic intracranial hemorrhage. The median time from emergency medical services scene arrival to puncture was 152 minutes, and each hour delay in this interval was associated with a 5.5% absolute decline in the likelihood of achieving modified Rankin Scale score 0 to 2. Conclusions— This largest-to-date Solitaire registry documents that the results of the randomized trials can be reproduced in the community. The decrease of clinical benefit over time warrants optimization of the system of care. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT02239640.
Stroke | 2015
Italo Linfante; Gail Walker; Alicia C. Castonguay; Guilherme Dabus; Amy Starosciak; Albert J. Yoo; Alex Abou-Chebl; Gavin W. Britz; Franklin A. Marden; Alexandria Alvarez; Rishi Gupta; Chun Huan J Sun; C Martin; William E. Holloway; Nils Mueller-Kronast; Joey D. English; Tim W. Malisch; Hormozd Bozorgchami; Andrew Xavier; A Rai; Michael T. Froehler; Aamir Badruddin; Thanh Nguyen; M. Asif Taqi; Michael G. Abraham; Vallabh Janardhan; Hashem Shaltoni; Roberta Novakovic; Peng R. Chen; Ritesh Kaushal
Background and Purpose— Failure to recanalize predicts mortality in acute ischemic stroke. In the North American Solitaire Acute Stroke registry, we investigated parameters associated with mortality in successfully recanalized patients. Methods— Logistic regression was used to evaluate baseline characteristics and recanalization parameters for association with 90-day mortality. A multivariable model was developed based on backward selection with retention criteria of P<0.05 from factors with at least marginal significance (P⩽0.10), then refit to minimize the number of excluded cases (missing data). Results— Successfully recanalized patients had lower mortality (25.2% [59/234] versus 46.9% [38/81] P<0.001). There was no difference in symptomatic intracranial hemorrhage between patients with successful versus failed recanalization (9% [21/234] versus 14% [11/79]; P=0.205). However, mortality was significantly higher in patients with symptomatic intracranial hemorrhage (72% [23/32] versus 26% [73/281]; P<0.001). Proximal occlusion (internal carotid artery or vertebrobasilar), initial National Institutes of Health Stroke Scale≥18, use of rescue therapy (P<0.05), and 3+ passes (P<0.10) were associated with mortality in recanalized patients. In the multivariate model with good predictive power (c index=0.72), proximal occlusion, initial National Institutes of Health Stroke Scale≥18, and use of rescue therapy remained significant independent predictors of 90-day mortality. Conclusions— Failure to recanalize and presence of symptomatic intracranial hemorrhage resulted in increased mortality. Despite successful recanalization, proximal occlusion, high National Institutes of Health Stroke Scale, and need for rescue therapy were predictors of mortality.
Stroke | 2018
Osama O. Zaidat; Alicia C. Castonguay; Italo Linfante; Rishi Gupta; Coleman O. Martin; William E. Holloway; Nils Mueller-Kronast; Joey D. English; Guilherme Dabus; Tim W. Malisch; Franklin A. Marden; Hormozd Bozorgchami; Andrew Xavier; A Rai; Michael T. Froehler; Aamir Badruddin; Thanh N. Nguyen; M. Asif Taqi; Michael G. Abraham; Albert J. Yoo; Vallabh Janardhan; Hashem Shaltoni; Roberta Novakovic; Alex Abou-Chebl; Peng R. Chen; Gavin W. Britz; Chung Huan J Sun; Vibhav Bansal; Ritesh Kaushal; Ashish Nanda
Background and Purpose— In acute ischemic stroke, fast and complete recanalization of the occluded vessel is associated with improved outcomes. We describe a novel measure for newer generation devices: the first pass effect (FPE). FPE is defined as achieving a complete recanalization with a single thrombectomy device pass. Methods— The North American Solitaire Acute Stroke Registry database was used to identify a FPE subgroup. Their baseline features and clinical outcomes were compared with non-FPE patients. Clinical outcome measures included 90-days modified Rankin Scale score, National Institutes of Health Stroke Scale score, mortality, and symptomatic intracranial hemorrhage. Multivariate analyses were performed to determine whether FPE independently resulted in improved outcomes and to identify predictors of FPE. Results— A total of 354 acute ischemic stroke patients underwent thrombectomy in the North American Solitaire Acute Stroke registry. FPE was achieved in 89 out of 354 (25.1%). More middle cerebral artery occlusions (64% versus 52.5%) and fewer internal carotid artery occlusions (10.1% versus 27.7%) were present in the FPE group. Balloon guide catheters were used more frequently with FPE (64.0% versus 34.7%). Median time to revascularization was significantly faster in the FPE group (median 34 versus 60 minutes; P=0.0003). FPE was an independent predictor of good clinical outcome (modified Rankin Scale score ⩽2 was seen in 61.3% in FPE versus 35.3% in non-FPE cohort; P=0.013; odds ratio, 1.7; 95% confidence interval, 1.1–2.7). The independent predictors of achieving FPE were use of balloon guide catheters and non-internal carotid artery terminus occlusion. Conclusions— The achievement of complete revascularization from a single Solitaire thrombectomy device pass (FPE) is associated with significantly higher rates of good clinical outcome. The FPE is more frequently associated with the use of balloon guide catheters and less likely to be achieved with internal carotid artery terminus occlusion.
Interventional Neurology | 2014
Syed A. Quadri; Vivek Ramakrishnan; Omid R. Hariri; M. Asif Taqi
Background and Objective: Balloon-assisted coil embolization has become an important adjunct in the endovascular treatment of intracranial aneurysms. The management of broad-necked cerebral aneurysms is technically perplexed due to a variety of factors, which include the difficulty in defining the aneurysm-parent vessel interface angiographically and problems in achieving complete aneurysmal occlusion. This could later predispose to regrowth or recanalization. We sought to determine the safety and efficacy of the TransForm™ occlusion balloon catheter (TOBC) for the coiling of intracranial aneurysms at our institute. Methods: A retrospective review was performed to identify TOBC cases between May 1, 2013, and April 30, 2014. Results: A total of 24 TOBC cases were identified. In 23 cases, the TOBC was used for balloon-remodeled coil embolization, and in 1 case, it was used for vasospasm treatment alone. Out of the total 24 cases in which the TOBC was used, 16 (66.6%) were ruptured aneurysms. Stents were used in 6/23 (26%) cases. In all cases, the balloon could be placed as intended. The inflation and deflation times ranged from 3 to 4 s. No serious complications were noted. In the experience of the authors, the balloon performed the intended role in most cases. Conclusions: This series shows that the TOBC is feasible, safe and useful in the treatment of cerebral aneurysms. The balloon was traceable to the intended site and the preparation, inflation and deflation times were short. We believe that the TOBC has effective utility in treating broad-necked and small aneurysms.
Interventional Neurology | 2018
M. Asif Taqi; Syed A. Quadri; Ajit S. Puri; Brian Fred Fitzsimmons; Jianhua Nancy Jin; A Rai; Curtis A. Given nd; Javier Masso; Ciaran J. Powers; Joey D. English; Osama O. Zaidat
Background and Purpose: Adjunctive treatments like balloon-assisted coil embolization (BACE) and stent-assisted coil embolization play a major role in the treatment of wide-neck and large intracranial aneurysms. The TransForm™ Occlusion Balloon Catheter (TOBC) registry is intended to evaluate the safety, efficacy, and efficiency of BACE using the TOBC. Method and Study Design: The TOBC registry is a prospective multicenter registry trial. Seven sites in the USA and 1 site in Spain participated and enrolled 81 patients. Results: The performance and safety of the TOBC was evaluated based on scoring for different variables. Scores were measured using a semiquantitative rating scale (1 = excellent, 5 = poor). The mean scores for these variables were as follows: visibility under fluoroscopy, 1.8; ability to reach the intended site, 1.6; stability during first positioning, 1.5; stability during inflation, 1.6; stability during deflation, 1.6; ability to temporarily stop flow, 1.6; and ability to assist in coil embolization, 1.7. The mean inflation and deflation times were 4.9 and 5.6 s, respectively. Complete obliteration of the aneurysm (Raymond class I) was achieved in 69.4% of the BACE cases. Thrombus formation occurred in 4/81 (4.8%) of the cases. In all cases, the thrombus resolved with medications, no patient suffered an infarction, and an underlying hypercoagulable state from subarachnoid hemorrhage was considered a contributing factor. Vessel rupture occurred in 1/81 (1.2%) of the cases, but was unrelated to TOBC use. Conclusion: BACE using the TOBC is safe and effective. All variables assessed for performance showed good-to-excellent results.
World Neurosurgery | 2018
Martin M. Mortazavi; Tania Hassanzadeh; Kianoush Khalili; Sajid S. Suriya; M. Asif Taqi; Salman Abbasi Fard; R. Shane Tubbs
BACKGROUND Various techniques have been used for wrap-clipping a ruptured, fusiform intracranial aneurysm; however, there is no available literature on use of the falx cerebri for wrap-clipping. We present a review of the literature, with an illustrative case, of a ruptured fusiform pericallosal artery aneurysm firmly attached to the lower edge of the falx cerebri and not amenable to endovascular intervention. METHODS Although the firm attachment between the inferior falx and the fusiform aneurysm was maintained, a section of the lower thinner part of the falx cerebri firmly attached to the aneurysm was dissected and wrapped around the fusiform aneurysm, and then stabilized with a fenestrated clip. We chose a segment slightly longer than the length of the fusiform aneurysm to avoid pre- and post-wrap-clipping stenosis. RESULTS Postprocedure, except for a small area of numbness on the left distal anterolateral left leg, the patient was neurologically intact and remained neurologically intact at a 12-month follow-up. CONCLUSIONS An inferior thin segment of the falx cerebri can be used for wrap-clipping of ruptured fusiform anterior cerebral artery aneurysms. Furthermore, the inferior falx can be wrapped around the attached fusiform anterior cerebral artery aneurysm without compromising flow, offering a safe solution in these unusually complex cases.
Interventional Neurology | 2018
Tim W. Malisch; Osama O. Zaidat; Alicia C. Castonguay; Franklin A. Marden; Rishi Gupta; Chung-Huan J Sun; Coleman O. Martin; William E. Holloway; Nils Mueller-Kronast; Joey D. English; Italo Linfante; Guilherme Dabus; Hormozd Bozorgchami; Andrew Xavier; A Rai; Michael T. Froehler; Aamir Badruddin; Thanh N. Nguyen; M. Asif Taqi; Michael G. Abraham; Vallabh Janardhan; Hashem Shaltoni; R Novakovic; Albert J. Yoo; Alex Abou-Chebl; Peng R. Chen; Gavin W. Britz; Ritesh Kaushal; Ashish Nanda; Raul G. Nogueira
Background: Various techniques are used to enhance the results of mechanical thrombectomy with stent-retrievers, including proximal arrest with balloon guide catheter (BGC), conventional large bore proximal catheter (CGC), or in combination with local aspiration through a large-bore catheter positioned at the clot interface (Aspiration-Retriever Technique for Stroke [ARTS]). We evaluated the impact of ARTS in the North American Solitaire Acute Stroke (NASA) registry. Summary: Data on the use of the aspiration technique were available for 285 anterior circulation patients, of which 29 underwent ARTS technique, 131 CGC, and 125 BGC. Baseline demographics were comparable, except that ARTS patients are less likely to have hypertension or atrial fibrillation. The ARTS group had more ICA occlusions (41.4 vs. 22% in the BGC, p = 0.04 and 26% in CGC, p = 0.1) and less MCA/M1 occlusions (44.8 vs. 68% in BGC and 62% in CGC). Time from arterial puncture to reperfusion or end of procedure with ARTS was shorter than with CGC (54 vs. 91 min, p = 0.001) and was comparable to the BGC time (54 vs. 67, p = 0.11). Final degree of reperfusion was comparable among the groups (TICI [modified Thrombolysis in Cerebral Infarction] score 2b or higher was 72 vs. 70% for CGC vs. 78% for BGC). Procedural complications, mortality, and good clinical outcome at 90 days were similar between the groups. Key Messages: The ARTS mechanical thrombectomy in acute ischemic stroke patients appears to yield better results as compared to the use of CGCs with no significant difference when compared to BGC. This early ARTS technique NASA registry data are limited by the earlier generation distal large bore catheters and small sample size. Future studies should focus on the comparison of ARTS and BGC techniques.