Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where M. Błażewicz is active.

Publication


Featured researches published by M. Błażewicz.


Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2011

FT-IR study of montmorillonite-chitosan nanocomposite materials.

C. Paluszkiewicz; Ewa Stodolak; Magdalena Hasik; M. Błażewicz

Bone defect is one of the most frequent problems in bone tissue reconstruction in which application of a biomaterial filling is necessary. It creates a still rising demand of biomaterials for bone surgery. Polymer-ceramic nanocomposites (e.g. based on chitosan matrix) is a group of novel materials whose properties such as strength, Youngs modulus, bioactivity and controlled degradation time make them suitable materials for filling bone defects. Investigations of nanocomposite foils which consisted of biopolymer-chitosan (CS) matrix and montmorillonite (MMT) as a nano-filler was the subject of the work. The nanocomposite materials were produced by a two-step dispersion of the nanoparticles in the biopolymer matrix. The first stage involved mechanical stirring and the second one - ultrasonic agitation. Mechanical tests were performed on the nanocomposites and their Youngs modulus was estimated. Significant improvement of mechanical properties of the nanocomposites in comparison with the pure polymer (CS) was observed. The nanocomposite foils (CS/MMT) were subjected to FT-IR spectroscopy investigations whose objective was to explain the reason of the change in mechanical characteristics of the nanocomposites. Transmission and ATR techniques operating in MIR range were used to study the nanocomposites. The FT-IR techniques were used to determine interactions at nanoparticle-biopolymer matrix interface. A pure unmodified CS foil was used as a reference material for FT-IR studies. It was proven that application of FT-IR techniques allows not only to identify phases, but also to explain structural changes in the systems studied.


Acta Biomaterialia | 2008

Comparative in vivo biocompatibility study of single- and multi-wall carbon nanotubes

Aneta Fraczek; Elżbieta Menaszek; C. Paluszkiewicz; M. Błażewicz

Carbon nanotubes are expected to be of use in both genetic engineering and biomaterials engineering. In each of these potential areas of application, nanoparticles are introduced into a living organism either in the form of active biomolecule carriers or as a result of the degradation process of an implant. In the present study we focus on the in vivo behavior of two types of carbon nanotubes (single- and multi-wall nanotubes). Raman and Fourier transform infrared spectroscopy, thermogravimetric analysis and differential scanning calorimetry techniques are used to characterize the materials before introducing them into the living system. The nanotubes were implanted into the skeletal rat muscle. A comparative analysis of the tissue reaction to the presence of the two types of carbon nanotubes was made. It was observed that multi-wall carbon nanotubes were found to form large aggregates within the living tissue, while distinctly smaller particles consisting of single-wall nanotubes were easily phagocytosed by macrophages and transported to local lymph nodes.


Journal of Molecular Structure | 2001

FTIR study of degradation products of aliphatic polyesters–carbon fibres composites

Elżbieta Pamuła; M. Błażewicz; Czesława Paluszkiewicz; Piotr Dobrzynski

Abstract Biodegradable polymer composites based on polylactides and polyglycolides constitute a group of materials characterised by good biocompatibility. They are considered in tissue engineering as scaffolds for cells proliferation and controlled tissue regeneration. Two types of biodegradable polymers possessing different chemical structure, molecular weights and crystallinity degrees and two composite materials made up of them and carbon fibres were analysed in this study. The samples were incubated in aqueous media for 8 weeks and analysed by means of Fourier transform infrared spectroscopy in the attenuated total reflection mode (FTIR-ATR). Infrared spectroscopy enabled identification of degradation products and estimation of the influence of carbon fibres on hydrolytic degradation of analysed polymers. Analysis of the infrared spectra showed that hydrolytic degradation process depends on chemical structure, molecular weight and crystallinity of polymers. Catalytic effect of carbon fibres at the initial stage of polymer degradation was observed. Further degradation is dependent on the properties of polymer.


Journal of Materials Science: Materials in Medicine | 2010

In vitro and in vivo studies on biocompatibility of carbon fibres

I. Rajzer; Elżbieta Menaszek; Lucie Bacakova; Monika Rom; M. Błażewicz

In the present study we focused on the in vitro and in vivo evaluation of two types of carbon fibres (CFs): hydroxyapatite modified carbon fibres and porous carbon fibres. Porous CFs used as scaffold for tissues regeneration could simultaneously serve as a support for drug delivery or biologically active agents which would stimulate the tissue growth; while addition of nanohydroxyapatite to CFs precursor can modify their biological properties (such as bioactivity) without subsequent surface modifications, making the process cost and time effective. Presented results indicated that fibre modification with HAp promoted formation of apatite on the fibre surface during incubation in simulated body fluid. The materials biocompatibility was determined by culturing human osteoblast-like cells of the line MG 63 in contact with both types of CFs. Both tested materials gave good support to adhesion and growth of bone-derived cells. Materials were implanted into the skeletal rat muscle and a comparative analysis of tissue reaction to the presence of the two types of CFs was done. Activities of marker metabolic enzymes: cytochrome c oxidase (CCO) and acid phosphatase were examined to estimate the effect of implants on the metabolic state of surrounding tissues. Presented results evidence the biocompatibility of porous CFs and activity that stimulates the growth of connective tissues. In case of CFs modified with hydroxyapatite the time of inflammatory reaction was shorter than in case of traditional CFs.


Biomaterials | 2002

In vitro response of macrophages to a new carbon-polylactide composite for the treatment of periodontal diseases

Maria Chomyszyn-Gajewska; Barbara Czajkowska; M. Błażewicz; Elżbieta Pamuła; Maria Ptak

The purpose of the study was to examine the response of macrophages and the concentration of selected released cytokines following contact with a new carbon-polylactide composite. The macrophages were grown on samples of the materials and on each of its components separately. Viability of the cells as well as concentrations of interleukins IL-6, IL-10, IL-12 and TNF-alpha were then determined. Some differences in the viability of the cells were demonstrated. They varied according to the kind of material used. After incubation with the serum, the composite and its components induced the release of IL-6, IL-12 and TNF-alpha which did not differ significantly from one another.


Molecules | 2013

Fibrous Polymeric Composites Based on Alginate Fibres and Fibres Made of Poly-ε-caprolactone and Dibutyryl Chitin for Use in Regenerative Medicine

Maciej Boguń; Izabella Krucińska; Agnieszka Kommisarczyk; Teresa Mikołajczyk; M. Błażewicz; Ewa Stodolak-Zych; Elżbieta Menaszek; A. Ścisłowska-Czarnecka

This work concerns the production of fibrous composite materials based on biodegradable polymers such as alginate, dibutyryl chitin (DBC) and poly-ε-caprolactone (PCL). For the production of fibres from these polymers, various spinning methods were used in order to obtain composite materials of different composition and structure. In the case of alginate fibres containing the nanoadditive tricalcium phosphate (TCP), the traditional method of forming fibres wet from solution was used. However in the case of the other two polymers the electrospinning method was used. Two model systems were tested for biocompatibility. The physicochemical and basic biological tests carried out show that the submicron fibres produced using PCL and DBC have good biocompatibility. The proposed hybrid systems composed of micrometric fibres (zinc and calcium alginates containing TCP) and submicron fibres (DBC and PCL) meet the requirements of regenerative medicine. The biomimetic fibre system, the presence of TCP nanoadditive, and the use of polymers with different resorption times provide a framework with specific properties on which bone cells are able to settle and proliferate.


Materials Science and Engineering: C | 2014

Titanium coated with functionalized carbon nanotubes--a promising novel material for biomedical application as an implantable orthopaedic electronic device.

Agata Przekora; Aleksandra Benko; Marek Nocuń; Jan Wyrwa; M. Błażewicz; Grazyna Ginalska

The aim of the study was to fabricate titanium (Ti) material coated with functionalized carbon nanotubes (f-CNTs) that would have potential medical application in orthopaedics as an implantable electronic device. The novel biomedical material (Ti-CNTs-H2O) would possess specific set of properties, such as: electrical conductivity, non-toxicity, and ability to inhibit connective tissue cell growth and proliferation protecting the Ti-CNTs-H2O surface against covering by cells. The novel material was obtained via an electrophoretic deposition of CNTs-H2O on the Ti surface. Then, physicochemical, electrical, and biological properties were evaluated. Electrical property evaluation revealed that a Ti-CNTs-H2O material is highly conductive and X-ray photoelectron spectroscopy analysis demonstrated that there are mainly COOH groups on the Ti-CNTs-H2O surface that are found to inhibit cell growth. Biological properties were assessed using normal human foetal osteoblast cell line (hFOB 1.19). Conducted cytotoxicity tests and live/dead fluorescent staining demonstrated that Ti-CNTs-H2O does not exert toxic effect on hFOB cells. Moreover, fluorescence laser scanning microscope observation demonstrated that Ti-CNTs-H2O surface retards to a great extent cell proliferation. The study resulted in successful fabrication of highly conductive, non-toxic Ti-CNTs-H2O material that possesses ability to inhibit osteoblast proliferation and thus has a great potential as an orthopaedic implantable electronic device.


Bulletin of Materials Science | 2015

Carbon nanotube-based coatings on titanium

E. Długoń; Wojciech Simka; Aneta Fraczek-Szczypta; Wiktor Niemiec; Jarosław Markowski; Marzena Szymanska; M. Błażewicz

This paper reports results of the modification of titanium surface with multiwalled carbon nanotubes (CNTs). The Ti samples were covered with CNTs via electrophoretic deposition (EPD) process. Prior to EPD process, CNTs were functionalized by chemical treatment. Mechanical, electrochemical and biological properties of CNT-covered Ti samples were studied and compared to those obtained for unmodified titanium surface. Atomic force microscopy was used to investigate the surface topography. To determine micromechanical characteristics of CNT-covered metallic samples indentation tests were conducted. Throughout electrochemical studies were performed in order to characterize the impact of the coating on the corrosion of titanium substrate. In vitro experiments were conducted using the human osteoblast NHOst cell line. CNT layers shielded titanium from corrosion gave the surface-enhanced biointegrative properties. Cells proliferated better on the modified surface in comparison to unmodified titanium. The deposited layer enhanced cell adhesion and spreading as compared to titanium sample.


Journal of Molecular Structure | 1999

Application of vibrational spectroscopy in the in vitro studies of carbon fiber-polylactic acid composite degradation.

M. Błażewicz; Maria Chomyszyn Gajewska; Czesława Paluszkiewicz

Abstract Vibrational spectroscopy was used for assessment of new material for stomatology, for guided tissue regeneration (GTR) techniqe.Implants applied in the healing of periodontal defects using GTR technique have to meet stringent requirements concerning their chemical as well physical properties.At present the implants prepared from two layers membranes differing in porosity in their outer and inner layers are studied clinically. Composite plates prepared by us consist of three layers: polylactic acid film, carbon fibres coated with polylactic acid and carbon fabric.Vibrational spectroscopic studies of the material; polylactic acid- carbon fiber have made it possible to analyse chemical reactions occurring between the polymer and carbon surface. Analysis of the IR spectra of samples treated in Ringer solution allowed to describe the phenomena resulting from the composite degradation. It was shown that material biostability is related to the presence of carbon fibers.


Biomedical Materials | 2016

Hybrid chitosan/β-1,3-glucan matrix of bone scaffold enhances osteoblast adhesion, spreading and proliferation via promotion of serum protein adsorption.

Agata Przekora; Aleksandra Benko; M. Błażewicz; Grazyna Ginalska

Initial protein adsorption to the material surface is crucial for osteoblast adhesion, survival, and rapid proliferation resulting in intensive new bone formation. The aim of this study was to demonstrate that modification of a chitosan matrix of chitosan/hydroxyapatite (chit/HA) biomaterial for bone tissue engineering applications with linear β-1,3-glucan (curdlan) leads to promotion of serum protein adsorption to the resultant scaffold (chit/glu/HA) and thus in enhancement of osteoblast adhesion, spreading and proliferation. Fabricated biomaterials were pre-adsorbed with different protein solutions and then protein adsorption and osteoblast behavior on the scaffolds were compared. Moreover, surface chemical composition, wettability and surface energy of biomaterials were compared. Modification of the chitosan matrix with β-1,3-glucan introduces a greater polarpart in the resultant chitosan/β-1,3-glucan matrix presumably resulting from more OH groups within the curdlan structure. Moreover, FTIR-ATR results suggest that there might be some sort of chemical interaction between the NH group of chitosan and the OH group of β-1,3-glucan. As a consequence, the chit/glu/HA scaffold adsorbs significantly more adhesion proteins that are crucial for osteoblasts compared to the chit/HA material, providing a higher density culture of well-spread osteoblasts on its surface. Obtained results revealed that not only is chit/glu/HA biomaterial a promising scaffold for bone tissue engineering applications, but the specific polysaccharide chit/glu matrix itself is promising for use in the biomedical material field to modify various biomaterials in order to enhance osteoblast adhesion and proliferation on their surfaces.

Collaboration


Dive into the M. Błażewicz's collaboration.

Top Co-Authors

Avatar

E. Długoń

AGH University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Aleksandra Benko

AGH University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ewa Stodolak-Zych

AGH University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Marek Nocuń

AGH University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

C. Paluszkiewicz

AGH University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Grazyna Ginalska

Medical University of Lublin

View shared research outputs
Top Co-Authors

Avatar

Agata Przekora

Medical University of Lublin

View shared research outputs
Researchain Logo
Decentralizing Knowledge