Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where M. Born is active.

Publication


Featured researches published by M. Born.


Stroke | 2005

Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: A prospective, intra-individual comparative analysis with digital subtraction angiography

Winfried A. Willinek; Marcus von Falkenhausen; M. Born; J Gieseke; Tobias Höller; Thomas Klockgether; Hj Textor; Hans H. Schild; Horst Urbach

Background and Purpose— Concomitant disease of the supra-aortic arteries can influence the outcome of surgical treatment of carotid artery stenosis. However, sensitivity and specificity data of noninvasive contrast-enhanced 3-dimensional (3D) magnetic resonance angiography (CE MRA) for the detection of steno-occlusive disease of the entire supra-aortic arteries including the circle of Willis remain unclear. We aimed to intra-individually compare high-spatial-resolution CE 3D MRA and digital subtraction angiography (DSA) for the assessment of steno-occlusive vascular disease of the supra-aortic arteries. Methods— CE MRA and DSA of the supra-aortic arteries were prospectively performed in 50 consecutive patients. Intra-individual comparison of CE MRA and DSA was available in 833 arteries. High-spatial-resolution CE MRA comprised a measured voxel size of 0.81 mm × 0.81 mm × 1 mm (0.66 mm3). Steno-occlusive vascular disease of the 833 arteries was assessed independently by 2 radiologists according to the NASCET criteria. Results— CE MRA had a sensitivity of 100% (73/73), a specificity of 99.3% (760/765), a positive predictive value of 93.6% (73/78), and a negative predictive value of 100% (760/760) by using a 70% to 99% threshold of arterial diameter stenosis. For detection of occlusion, sensitivity, specificity, PPV, and NPV value of CE MRA were 100%, respectively. Conclusions— Noninvasive high-spatial-resolution CE MRA is suited to replace diagnostic DSA for the detection of steno-occlusive disease of the supra-aortic arteries.


Journal of Magnetic Resonance Imaging | 2005

Sensitivity encoding (SENSE) for contrast-enhanced 3D MR angiography of the abdominal arteries.

M. Born; Winfried A. Willinek; Jürgen Gieseke; Marcus von Falkenhausen; Hans H. Schild; Christiane K. Kuhl

To assess sensitivity encoding (SENSE) for contrast‐enhanced MR angiography (CE‐MRA) of the abdominal arteries in comparison with standard MRA protocols.


Radiology | 2003

Time-of-Flight MR Angiography: Comparison of 3.0-T Imaging and 1.5-T Imaging—Initial Experience

Winfried A. Willinek; M. Born; Birgit Simon; Henriette J. Tschampa; Carsten Krautmacher; Jürgen Gieseke; Horst Urbach; Hans J. Textor; Hans H. Schild


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2004

Sensitivity Encoding (SENSE) zur intrakraniellen time-of-flight MR Angiographie mit 1024er Matrix bei 3.0T

Winfried A. Willinek; J Gieseke; M. Born; M von Falkenhausen; Hj Textor; Horst Urbach; H. H. Schild; Christiane K. Kuhl


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2004

Renale Diatrizoatexkretion (Gastrografin) als diagnostisch verwertbarer Hinweis auf ösophagogastrointestinale Nahtdehiszenzen und Perforationen

M. Born; C. Axmann; R. Kader; M von Falkenhausen; C Manka; Winfried A. Willinek; H. H. Schild


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2007

Pediatric imaging at 3T

M. Born; J Gieseke; Ursula E. Jaeger; Torsten Sommer; Winfried A. Willinek; H. H. Schild


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2004

Hochfeld MR Angiographie der supraaortalen Arterien bei 3.0T: erlaubt der Signalgewinn die Verwendung der Quadratur-Körperspule an Stelle der Hals-Nackenspule?

Winfried A. Willinek; J Gieseke; M von Falkenhausen; M. Born; Hj Textor; Christiane K. Kuhl; Horst Urbach; H. H. Schild


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2004

3.0T intracranial MR angiography at 1024 matrix using Sensitivity Encoding (SENSE)

Winfried A. Willinek; J Gieseke; M. Born; M von Falkenhausen; C Manka; Hj Textor; Christiane K. Kuhl; H. H. Schild


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2004

CE-MRA of abdominal and peripheral vessels at 3.0 T – initial experiences

M. Born; J Gieseke; Winfried A. Willinek; Christiane K. Kuhl; G. Lutterbey; M von Falkenhausen; H. H. Schild


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2004

3.0T CE MRA of the supraaortic arteries: Does the signal gain at high field allow to replace the phased array coil by the quadrature body coil?

Winfried A. Willinek; J Gieseke; M. Born; M von Falkenhausen; Thomas A. Bayer; R Blömer; Hj Textor; Horst Urbach; H. H. Schild

Collaboration


Dive into the M. Born's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge