M.C. Carmona-Benitez
Case Western Reserve University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by M.C. Carmona-Benitez.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2013
D. S. Akerib; X. Bai; S. Bedikian; E. Bernard; A. Bernstein; A. Bolozdynya; A. Bradley; D. Byram; S. B. Cahn; C. Camp; M.C. Carmona-Benitez; D. Carr; J.J. Chapman; A.A. Chiller; C. Chiller; K. Clark; T. Classen; T. Coffey; A. Curioni; E. Dahl; S. Dazeley; L. de Viveiros; A. Dobi; E. Dragowsky; E. Druszkiewicz; B. Edwards; C.H. Faham; S. Fiorucci; R.J. Gaitskell; K.R. Gibson
The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles (WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross-section per nucleon of 2×10-46cm2, equivalent to ∼1event/100kg/month in the inner 100-kg fiducial volume (FV) of the 370-kg detector. The overall background goals are set to have <1 background events characterized as possible WIMPs in the FV in 300 days of running. This paper describes the design and construction of the LUX detector.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2013
D. S. Akerib; X. Bai; E. Bernard; A. Bernstein; A. Bradley; D. Byram; S. B. Cahn; M.C. Carmona-Benitez; D. Carr; J.J. Chapman; K. Clark; T. Coffey; B. Edwards; L. de Viveiros; M. R. Dragowsky; E. Druszkiewicz; C.H. Faham; S. Fiorucci; R.J. Gaitskell; K.R. Gibson; C. Hall; M. Hanhardt; B. Holbrook; M. Ihm; R. G. Jacobsen; L. Kastens; K. Kazkaz; N.A. Larsen; C. Lee; A. Lindote
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U/<0.3 232Th/<8.3 40K/2.0±0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of ×124 238U/×19 232Th/×18 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5–6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of ×125 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of ×136. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.
Physical Review D | 2016
D. S. Akerib; H.M. Araújo; X. Bai; A.J. Bailey; J. Balajthy; P. Beltrame; E. Bernard; A. Bernstein; T. P. Biesiadzinski; E. M. Boulton; A. Bradley; R. Bramante; S. B. Cahn; M.C. Carmona-Benitez; C. Chan; J.J. Chapman; A.A. Chiller; C. Chiller; A. Currie; J. E. Cutter; T. J. R. Davison; L. de Viveiros; A. Dobi; J. Dobson; E. Druszkiewicz; Blair Edwards; C.H. Faham; S. Fiorucci; R.J. Gaitskell; V. M. Gehman
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170 000 highly pure and spatially uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a reanalysis of the LUX run 3 weakly interacting massive particle search.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2012
D. S. Akerib; X. Bai; S. Bedikian; E. Bernard; A. Bernstein; A. Bradley; S. B. Cahn; M.C. Carmona-Benitez; D. Carr; J.J. Chapman; K. Clark; T. Classen; T. Coffey; S. Dazeley; L. de Viveiros; A. Dobi; M. R. Dragowsky; E. Druszkiewicz; C.H. Faham; S. Fiorucci; R.J. Gaitskell; K.R. Gibson; C. Hall; M. Hanhardt; B. Holbrook; M. Ihm; R. G. Jacobsen; L. Kastens; K. Kazkaz; R. Lander
Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpoint, there is no single source or beam, but rather a collection of sources with potentially complicated spatial extent. LUXSim is a simulation framework used by the LUX collaboration that takes a component-centric approach to event generation and recording. A new set of classes allows for multiple radioactive sources to be set within any number of components at run time, with the entire collection of sources handled within a single simulation run. Various levels of information can also be recorded from the individual components, with these record levels also being set at run time. This flexibility in both source generation and information recording is possible without the need to recompile, reducing the complexity of code management and the proliferation of versions. Within the code itself, casting geometry objects within this new set of classes rather than as the default Geant4 classes automatically extends this flexibility to every individual component. No additional work is required on the part of the developer, reducing development time and increasing confidence in the results. We describe the guiding principles behind LUXSim, detail some of its unique classes and methods, and give examples of usage.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2012
D. S. Akerib; X. Bai; S. Bedikian; E. Bernard; A. Bernstein; A. Bradley; S. B. Cahn; M.C. Carmona-Benitez; D. Carr; J.J. Chapman; K. Clark; T. Classen; T. Coffey; A. Curioni; S. Dazeley; L. de Viveiros; M. R. Dragowsky; E. Druszkiewicz; C.H. Faham; S. Fiorucci; R.J. Gaitskell; K.R. Gibson; C. Hall; M. Hanhardt; B. Holbrook; M. Ihm; R. G. Jacobsen; L. Kastens; K. Kazkaz; R. Lander
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline suppression that allows for a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This paper describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.
Physical Review D | 2018
D. S. Akerib; S. Alsum; H.M. Araújo; X. Bai; A.J. Bailey; J. Balajthy; P. Beltrame; E. Bernard; A. Bernstein; T. P. Biesiadzinski; E. M. Boulton; P. Brás; D. Byram; M.C. Carmona-Benitez; C. Chan; A. Currie; J. E. Cutter; T. J. R. Davison; A. Dobi; E. Druszkiewicz; Blair Edwards; Fallon; A. Fan; S. Fiorucci; R.J. Gaitskell; J. Genovesi; C. Ghag; M. Gilchriese; C. Hall; S. J. Haselschwardt
Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. We present a measurement of liquid xenon scintillation characteristics in the LUX dark matter detector and develop a pulse shaped based discrimination parameter to be used for particle identification. To accurately measure the scintillation characteristics, we develop a template-fitting method to reconstruct the detection time of photons. Analyzing calibration data collected during the 2013-16 LUX WIMP search, we measure a singlet-to-triplet scintillation ratio for electron recoils (ER) that is consistent with existing literature, and we make a first-ever measurement of the NR singlet-to-triplet ratio at recoil energies below 74 keV. A prompt fraction discrimination parameter exploits the difference of the photon time spectra for NR and ER events and is optimized to have the least number of ER events that occur in the 50\% NR acceptance region. When this discriminator is used in conjunction with charge-to-light discrimination on the calibration data, the signal-to-noise ratio in the NR dark matter acceptance region increases by up to a factor of two.
26th International Conference on Low Temperature Physics, LT 2011 | 2012
Dongming Mei; D. S. Akerib; X. H. Bai; S. Bedikian; E. Bernard; A. Bolozdynya; A. Bradley; S. B. Cahn; C. Camp; M.C. Carmona-Benitez; D. Carr; J.J. Chapman; K. Clark; T. Classen; T. Coffey; A. Curioni; E. Dahl; S. Dazeley; L. de Viveiros; M. R. Dragowsky; E. Druszkiewicz; C.H. Faham; S. Fiorucci; R.J. Gaitskell; K.R. Gibson; C. Hall; M. Hanhardt; B. Holbrook; M. Ihm; R. G. Jacobsen
Observation of rotational curve of spiral galaxies shows that a large fraction (~23%) of the mass density of the universe is unaccounted for. Such a significant percentage of missing dark matter suggests that the universe may consist of new types of elementary particles. A compelling explanation for the new particles is the existence of Weakly Interacting Massive Particles (WIMPs), which are non-baryonic particles characterized by particle physics theories beyond the Standard Model. WIMPs are believed to only interact through the weak force and gravity; hence the interaction cross section with ordinary matter is extremely small. Therefore, experimental techniques that combine low radioactivity, low energy thresholds, efficient discrimination against electronic recoil backgrounds, and scalability to large detector masses can only be performed at a deep underground environment where the interference of cosmic rays is obviated. In this paper, we report a cryogenic large liquid xenon detector for dark matter searches at Sanford Lab (Davis Cavern) in the Homestake Mine, USA. The goal of the large underground xenon (LUX) dual-phase detector is to clearly detect (or exclude) WIMPs with a spin independent cross-section per nucleon of 7 × 10−46 cm2, equivalent to ~0.5 events/100 kg/month in an inner 100 kg fiducial volume (FV) of a 300 kg LXe detector.
Physical Review Letters | 2016
D. S. Akerib; H.M. Araújo; X. Bai; A.J. Bailey; J. Balajthy; P. Beltrame; E. Bernard; A. Bernstein; T. P. Biesiadzinski; E. M. Boulton; A. Bradley; R. Bramante; S. B. Cahn; M.C. Carmona-Benitez; C. Chan; J.J. Chapman; A.A. Chiller; C. Chiller; A. Currie; J. E. Cutter; T. J. R. Davison; L. de Viveiros; A. Dobi; J. Dobson; E. Druszkiewicz; Blair Edwards; C.H. Faham; S. Fiorucci; R.J. Gaitskell; V. M. Gehman
arXiv: Instrumentation and Methods for Astrophysics | 2011
D.C. Malling; K.T. Lesko; K. Kazkaz; J.R. Verbus; J. T. White; P. Sorensen; P. Majewski; A. Lyashenko; D. Carr; M. Sweany; M. Szydagis; W. Skulski; A. Currie; E. Bernard; K.R. Gibson; T. Stiegler; J. Mock; M. Wlasenko; T. J. Sumner; S. Dazeley; H. N. Nelson; D.S. Leonard; L. Reichhart; N. A. Larsen; N. Walsh; C. Lee; R. Webb; C.H. Faham; E. Druszkiewicz; K. Clark
Physical Review Letters | 2016
D. S. Akerib; H.M. Araújo; X. Bai; A.J. Bailey; J. Balajthy; P. Beltrame; E. Bernard; A. Bernstein; T. P. Biesiadzinski; E. M. Boulton; A. Bradley; R. Bramante; S. B. Cahn; M.C. Carmona-Benitez; C. Chan; J.J. Chapman; A.A. Chiller; C. Chiller; A. Currie; J. E. Cutter; T. J. R. Davison; L. de Viveiros; A. Dobi; J. Dobson; E. Druszkiewicz; Blair Edwards; C.H. Faham; S. Fiorucci; R.J. Gaitskell; V. M. Gehman