Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where M. Filomena Camões is active.

Publication


Featured researches published by M. Filomena Camões.


Analytica Chimica Acta | 2011

Optimization of the determination of chemical oxygen demand in wastewaters.

Alexandra Silva; Ricardo J. N. Bettencourt da Silva; M. Filomena Camões

Chemical oxygen demand (COD) is one of the most relevant chemical parameters for the management of wastewater treatment facilities including the control of the quality of an effluent. The adequacy of decisions based on COD values relies on the quality of the measurements. Cost effective management of the minor sources of uncertainty can be applied to the analytical procedure without affecting measurement quality. This work presents a detailed assessment of the determination of COD values in wastewaters, according to ISO6060:1989 standard, which can support reduction of both measurement uncertainty and cost of analysis. This assessment includes the definition of the measurement traceability chain and the validation of the measurement procedure supported on sound and objective criteria. Detailed models of the measurement performance, including uncertainty, developed from the Differential Approach, were successfully validated by proficiency tests. The assumption of the measurement function linearity of the uncertainty propagation law was tested through the comparison with the numerical Kragten method. The gathered information supported the definition of strategies for measurement uncertainty or cost reduction. The developed models are available as electronic supplementary material, in an MS-Excel file, to be updated with the users data.


Analytical Letters | 2010

The Quality of Standards in Least Squares Calibrations

Ricardo J. N. Bettencourt da Silva; M. Filomena Camões

Frequently, the Least Square Regression Model (LSRM) assumption related to standards quality is either forgotten or formulated in too strict of a way, making its application unsuccessful or difficult. This work posits that the LSRM requires calibration standards with concentration ratios affected by negligible uncertainties that are achievable for standard solutions with large relative uncertainties. Criterion to test this assumption and a model to take into account the uncertainty of standards in performed quantifications are presented. The developed models were successfully tested with a combination of experimental data about interpolation uncertainty, for the determination of hexachlorobenzene by GC-ECD, with simulated values of standards concentrations.


Analytica Chimica Acta | 1990

Calculation of reference pH values for standard solutions from the corresponding acid dissociation constants

M. J. Guiomar Lito; M. Filomena Camões; M. Isabel A. Ferra; Arthur K. Covington

Abstract Making the simplest possible assumption about the activity coefficient of the charged species, pH values of standard buffer solutions have been evaluated from the thermodynamic acidity constants, K, of the weak acids involved. A general equation is given for a triprotic acid, H3A, as it can be simplified to derive the equations for other systems. A computer program for the solution of the equation was written giving mH values, species distribution coefficients, α, buffer capacities, β, species activity coefficients, γ, and ionic strength, I. Iteration was continued until agreement between successive values to within 1 ± 10−6 was reached. The activity coefficients of singly charged ions were taken as equal to γCl, where log γCl=−AI1/2 (1 + 1.5I1/2), which is the Bates-Guggenheim convention, and those of doubly and triply charged ions were given by the valence relations of the Debye-Huckel theory as γ4Cl and γ9Cl, respectively.


Food Chemistry | 2014

Carotenoid stability in fruits, vegetables and working standards – Effect of storage temperature and time

M. Graça Dias; M. Filomena Camões; Luísa Oliveira

The effects of freezing and storage temperature on the mass fraction of α- and β-carotene, β-cryptoxanthin, lutein, lycopene and zeaxanthin in minimally processed fresh food products, were evaluated after sample preparation, extraction and saponification (only when strictly necessary). Effects of freezing and long-term stability were studied at two temperatures, -20 and -70°C, using high performance liquid chromatography (reversed phase columns, UV-Vis diode array detector) at time points during storage; measurement uncertainty was included in the evaluation. Stability of working standard solutions was also examined. Freezing did not affect the carotenoid mass fraction under the conditions studied. Carotenoids in orange, cherry, peach, apple, and kale were stable (except α-carotene and zeaxanthin in peach) for 13, 9.7, 5.7, 2.5 and 7.5months, respectively. For these food sample matrices, no significant difference between the freezing/storage at -20 and -70°C was observed. Standard solutions (0.05-5μg/mL) were stable for at least 6months at -70°C, except lycopene which at 0.05μg/mL was apparently stable only for six weeks.


Analytica Chimica Acta | 2003

Evaluation of sample processing and sub-sampling performance

Ricardo J. N. Bettencourt da Silva; Helena Figueiredo; Júlia R. Santos; M. Filomena Camões

Abstract A methodology for the estimation of sample processing and sub-sampling performance based on the comparison of the global method experimental dispersion of results with the uncertainty estimated from developed models for the subsequent analytical steps is presented. This approach is a valuable alternative to the evaluation of adequate experimental information using a classical ANOVA, since the significance of the sample processing and sub-sampling is evaluated with a higher number of degrees of freedom for the same number of experimental assays, due to the high number of degrees of freedom associated with the uncertainty estimated for the subsequent analytical steps from the combination of the involved sources of uncertainty. Considering the construction of a model to describe the performance of the analytical steps following sample processing and sub-sampling over a broad concentration range, the experimental assays involved at the evaluation of the sample processing and sub-sampling can be performed at any concentration meeting the previously validated range and several months after the development of that model once its adequacy has been proven over time. This approach, which also allows the construction of a detailed performance model for the global analytical method over a broad concentration range, was applied to the determination of pesticide residues in apples by gas-chromatography with electron capture detector. Considering that no information was available regarding the samples heterogeneity, sub-sampling performance was evaluated considering a sample representing the worst expectable homogeneity. This was accomplished by spiking just one out of the 10 halves of apples processed in each sample. The developed model for the performance of the analytical method was successfully and easily applied to routine analysis through an automated link between the information generated by the chromatograph software with a file containing the model.


Analytica Chimica Acta | 2003

Evaluation of the analytical method performance for incurred samples

Ricardo J. N. Bettencourt da Silva; Júlia R. Santos; M. Filomena Camões

Abstract A methodology for the evaluation of the performance of an analytical method for incurred samples is presented. Since this methodology is based on intra-laboratory information, it is suitable for analytical fields that lack reference materials with incurred analytes and it can be used to evaluate the analytical steps prior to the analytical portion, which are usually excluded in proficiency tests or at the certification of reference materials. This methodology can be based on tests performed on routine samples allowing the collection of information on the more relevant combinations analyte/matrix; therefore, this approach is particularly useful for analytical fields that involve a high number of analyte/matrix combinations, which are difficult to cover even considering the frequent participation in expensive proficiency tests. This approach is based on the development of a model of the performance of the analytical method based on the differential approach for the quantification of measurement uncertainty and on the comparison of recovery associated with each one of the analytical steps whose performance can vary with the analyte origin, for spiked and incurred samples. This approach was applied to the determination of pesticide residues in apples. For the analytes covered, no evidence was found that the studied sample processing and extraction steps performance for this matrix varies with the analyte origins.


Analyst | 2002

Worst case uncertainty estimates for routine instrumental analysis

Ricardo J. N. Bettencourt da Silva; Júlia R. Santos; M. Filomena Camões

A methodology for the worst case measurement uncertainty estimation for analytical methods which include an instrumental quantification step, adequate for routine determinations, is presented. Although the methodology presented should be based on a careful evaluation of the analytical method, the resulting daily calculations are very simple. The methodology is based on the estimation of the maximum value for the different sources of uncertainty and requires the definition of limiting values for certain analytical parameters. The simplification of the instrumental quantification uncertainty estimation involves the use of the standard deviation obtained from control charts relating to the concentrations estimated from the calibration curves for control standards at the highest calibration level. Three levels of simplification are suggested, as alternatives to the detailed approach, which can be selected according to the proximity of the sample results to decision limits. These approaches were applied to the determination of pesticide residues in apples (CEN, EN 12393), for which the most simplified approach showed a relative expanded uncertainty of 37.2% for a confidence level of approximately 95%.


Journal of Solution Chemistry | 1998

Equilibrium in Saturated Ca(OH)2 Solutions: Parameters and Dissociation Constants

M. J. Guiomar Lito; M. Filomena Camões; Arthur K. Covington

A new computer program has been developed for the calculation of pH, pOH, hydroxide ion concentration mOH, species distribution coefficients αi, ionic activity coefficients γi ionic strength I, buffer capacity β, solubility product Ks0, and the two dissociation constants, Kb1 and Kb2, corresponding, respectively, to first and second dissociation steps of Ca(OH)2 in aqueous solution. Previously developed methodology, for the calculation of pH, αi, γiI, and β parameters of pH buffer solutions, starting from the corresponding acidity constants, has been adapted for the case of aqueous Ca(OH)2 solutions, for which the pertinent stoichiometric relationships are different from those applicable to mixtures of acids and their salts. The results show that, contrary to what is currently assumed, the first dissociation is far from complete. Values are given for the concentrations and activities of species Ca(OH)2(aq), Ca(OH)+(aq), and Ca2+ (aq) in saturated calcium hydroxide solutions at 25°C.


Analytica Chimica Acta | 2013

Weighted calibration with reduced number of signals by weighing factor modelling: application to the identification of explosives by ion chromatography.

Beatriz Brasil; Ricardo J. N. Bettencourt da Silva; M. Filomena Camões; Pedro A.S. Salgueiro

The linear weighted regression model (LW) can be used to calibrate analytical instrumentation in a range of quantities (e.g. concentration or mass) wider than possible by the linear unweighted regression model, LuW (i.e. the least squares regression model), since this model can be applied when signals are not equally precise through the calibration range. If precision of signals varies within the calibration range, the regression line should be defined taking into account that more precise signals are more reliable and should count more to define regression parameters. Nevertheless, the LW requires the determination of the variation of signals precision through the calibration range. Typically, this information is collected experimentally for each calibration, requiring a large number of replicate collection of signals of calibrators. This work proposes reducing the number of signals needed to perform LW calibrations by developing models of weighing factors robust to daily variations of instrument sensibility. These models were applied to the determination of the ionic composition of the water soluble fraction of explosives. The adequacy of the developed models was tested through the analysis of control standards, certified reference materials and the ion balance of anions and cations in aqueous extracts of explosives, considering the measurement uncertainty estimated by detailed metrological models. The high success rate of the comparisons between estimated and known quantity values of reference solutions, considering results uncertainty, proves the validity of developed metrological models. The relative expanded measurement uncertainty of single determinations ranged from 1.93% to 35.7% for calibrations performed along 4 months.


Talanta | 2015

Designing valid and optimised standard addition calibrations: Application to the determination of anions in seawater

Joana Rodrigues; Ricardo J. N. Bettencourt da Silva; M. Filomena Camões; Cristina Oliveira

A strategy for designing valid standard addition calibrations and for optimising their uncertainty is presented. The design of calibrations involves the development of models of the sensitivity and precision of the instrumental signal, in a wide range of analyte concentration (or any other studied quantity), and the definition of sample dilution and standard addition procedures that allow fulfilling the assumptions of the linear unweighted regression model in, typically, a smaller range of standard addition calibrations. Calibrators are prepared by diluting the sample and adding analyte with negligible uncertainty to fit in a concentration range where signals are homoscedastic. The minimisation of the uncertainty is supported on detailed measurement uncertainty models function of the calibrators preparation procedure and of analytical instrumentation performance. The number of collected signals replicates is defined by balancing their impact on the estimated expanded uncertainty, the resources needed and the target (maximum) uncertainty for the intended use of measurements. The calibration design strategy was successfully applied to the determination of the mass concentration (mg L(-1)) of Cl(-), Br(-), NO3(-) and SO4(-2) in seawater by ion chromatography. A target expanded uncertainty of 20% was defined for the determination of Cl(-), NO3(-) and SO4(-2), or 40% for the determination of the smaller mass concentration of Br(-). The developed measurement model produced reliable predictions of the measurement uncertainty from approximate concentration of the analyte in the sample, before its accurate quantification, thus proving optimisation is effective. Predictions are more prone to the variability of the measurement uncertainty estimation if based on low number of calibrators signals. The reported relative expanded uncertainty ranged from 7.1% to 49%.

Collaboration


Dive into the M. Filomena Camões's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Srečko Oman

University of Ljubljana

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Raj Rajagopalan

National University of Singapore

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge