Publication


Featured researches published by M Gillin.


International Journal of Radiation Oncology Biology Physics | 1993

Radiation therapy oncology group : radiosurgery quality assurance guidelines

Edward G. Shaw; Robert W. Kline; M Gillin; Luis Souhami; Alan Hirschfeld; Robert P. Dinapoli; Linda Martin

A multidisciplinary Radiation Therapy Oncology Group (RTOG) task force has developed quality assurance guidelines for radiosurgery. The purpose of the guidelines are fourfold: (1) To ensure that participating institutions have the proper equipment and appropriate technique(s) to administer radiosurgery; (2) to outline a standard data set for each treated patient to assess protocol compliance; (3) to define minor and major deviations in protocol treatment; and (4) to set forth clinical data necessary to determine treatment efficacy, including failure patterns, and treatment toxicity. These guidelines are being implemented into active and developing radiosurgery protocols.


Practical radiation oncology | 2012

Radiotherapeutic and surgical management for newly diagnosed brain metastasis(es): An American Society for Radiation Oncology evidence-based guideline

May N. Tsao; Dirk Rades; Andrew Wirth; Simon S. Lo; Brita Danielson; Laurie E. Gaspar; Paul W. Sperduto; Michael A. Vogelbaum; Jeffrey D. Radawski; Jian Z. Wang; M Gillin; Najeeb Mohideen; Carol A. Hahn; Eric L. Chang

Purpose To systematically review the evidence for the radiotherapeutic and surgical management of patients newly diagnosed with intraparenchymal brain metastases. Methods and Materials Key clinical questions to be addressed in this evidence-based Guideline were identified. Fully published randomized controlled trials dealing with the management of newly diagnosed intraparenchymal brain metastases were searched systematically and reviewed. The U.S. Preventative Services Task Force levels of evidence were used to classify various options of management. Results The choice of management in patients with newly diagnosed single or multiple brain metastases depends on estimated prognosis and the aims of treatment (survival, local treated lesion control, distant brain control, neurocognitive preservation). Single brain metastasis and good prognosis (expected survival 3 months or more): For a single brain metastasis larger than 3 to 4 cm and amenable to safe complete resection, whole brain radiotherapy (WBRT) and surgery (level 1) should be considered. Another alternative is surgery and radiosurgery/radiation boost to the resection cavity (level 3). For single metastasis less than 3 to 4 cm, radiosurgery alone or WBRT and radiosurgery or WBRT and surgery (all based on level 1 evidence) should be considered. Another alternative is surgery and radiosurgery or radiation boost to the resection cavity (level 3). For single brain metastasis (less than 3 to 4 cm) that is not resectable or incompletely resected, WBRT and radiosurgery, or radiosurgery alone should be considered (level 1). For nonresectable single brain metastasis (larger than 3 to 4 cm), WBRT should be considered (level 3). Multiple brain metastases and good prognosis (expected survival 3 months or more): For selected patients with multiple brain metastases (all less than 3 to 4 cm), radiosurgery alone, WBRT and radiosurgery, or WBRT alone should be considered, based on level 1 evidence. Safe resection of a brain metastasis or metastases causing significant mass effect and postoperative WBRT may also be considered (level 3). Patients with poor prognosis (expected survival less than 3 months): Patients with either single or multiple brain metastases with poor prognosis should be considered for palliative care with or without WBRT (level 3). It should be recognized, however, that there are limitations in the ability of physicians to accurately predict patient survival. Prognostic systems such as recursive partitioning analysis, and diagnosis-specific graded prognostic assessment may be helpful. Conclusions Radiotherapeutic intervention (WBRT or radiosurgery) is associated with improved brain control. In selected patients with single brain metastasis, radiosurgery or surgery has been found to improve survival and locally treated metastasis control (compared with WBRT alone).


Medical Physics | 2010

Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies.

Bijan Arjomandy; Ramesh C. Tailor; A Anand; Narayan Sahoo; M Gillin; K Prado; Milos Vicic

PURPOSE Since the Gafchromic film EBT has been recently replaced by the newer model EBT2, its characterization, especially energy dependence, has become critically important. The energy dependence of the dose response of Gafchromic EBT2 film is evaluated for a broad range of energies from different radiation sources used in radiation therapy. METHODS The beams used for this study comprised of kilovoltage x rays (75, 125, and 250 kVp), 137Cs gamma (662 KeV), 60Co gamma (1.17-1.33 MeV), megavoltage x rays (6 and 18 MV), electron beams (6 and 20 MeV), and proton beams (100 and 250 MeV). The films response to each of the above energies was measured over the dose range of 0.4-10 Gy, which corresponds to optical densities ranging from 0.05 to 0.74 for the film reader used. RESULTS The energy dependence of EBT2 was found to be relatively small within measurement uncertainties (1 sigma = +/- 4.5%) for all energies and modalities. CONCLUSION For relative and absolute dosimetry of radiation therapy beams, the weak energy dependence of the EBT2 makes it most suitable for clinical use compared to other films.


Medical Physics | 2009

Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston.

M Gillin; Narayan Sahoo; M Bues; George Ciangaru; Gabriel O. Sawakuchi; F Poenisch; Bijan Arjomandy; Craig Martin; U Titt; Kazumichi Suzuki; Alfred R. Smith; X. Ronald Zhu

PURPOSE To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). METHODS Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm2 and over a maximum scan area at the isocenter of 30 x 30 cm2. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. RESULTS The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. CONCLUSIONS The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.


Physics in Medicine and Biology | 2006

Dosimetric properties of photon beams from a flattening filter free clinical accelerator

Oleg N. Vassiliev; U Titt; Falk Pönisch; Stephen F. Kry; Radhe Mohan; M Gillin

Basic dosimetric properties of 6 MV and 18 MV photon beams from a Varian Clinac 21EX accelerator operating without the flattening filter have been measured. These include dose rate data, depth dose dependencies and lateral profiles in a water phantom, total scatter factors and transmission factors of a multileaf collimator. The data are reviewed and compared with measurements for the flattened beams. The unflattened beams have the following: a higher dose rate by factors of 2.3 (6 MV) and 5.5 (18 MV) on the central axis; lower out-of-field dose due to reduced head scatter and softer spectra; less variation of the total scatter factor with field size; and less variation of the shape of lateral dose profiles with depth. The findings suggest that with a flattening filter free accelerator better radiation treatments can be developed, with shorter delivery times and lower doses to normal tissues and organs.


Medical Physics | 2002

Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator.

X. R. Zhu; P Jursinic; Daniel F. Grimm; F. Lopez; Jason Rownd; M Gillin

A new type of radiographic film, Kodak EDR2 film, was evaluated for dose verification of intensity modulated radiation therapy (IMRT) delivered by a static multileaf collimator (SMLC). A sensitometric curve of EDR2 film irradiated by a 6 MV x-ray beam was compared with that of Kodak X-OMAT V (XV) film. The effects of field size, depth and dose rate on the sensitometric curve were also studied. It is found that EDR2 film is much less sensitive than XV film. In high-energy x-ray beams, the double hit process is the dominant mechanism that renders the grains on EDR2 films developable. As a result, in the dose range that is commonly used for film dosimetry for IMRT and conventional external beam therapy, the sensitometric curves of EDR2 films cannot be approximated as a linear function, OD = c * D. Within experimental uncertainty, the film sensitivity does not depend on the dose rate (50 vs 300 MU/min) or dose per pulse (from 1.0 x 10(-4) to 4.21 x 10(-4) Gy/pulse). Field sizes and depths (up to field size of 10 x 10 cm2 and depth = 10 cm) have little effect on the sensitometric curves. Percent depth doses (PDDs) for both 6 and 23 MV x rays were measured with both EDR2 and XV films and compared with ion chamber data. Film data are within 2.5% of the ion chamber results. Dose profiles measured with EDR2 film are consistent with those measured with an ion chamber. Examples of measured IMRT isodose distributions versus calculated isodoses are presented. We have used EDR2 films for verification of all IMRT patients treated by SMLC in our clinic. In most cases, with EDR2 film, actual clinical daily fraction doses can be used for verification of composite isodose distributions of SMLC-based IMRT.


Cancer | 2011

Phase 2 study of high-dose proton therapy with concurrent chemotherapy for unresectable stage III nonsmall cell lung cancer.

Joe Y. Chang; Ritsuko Komaki; Charles Lu; Hong Y. Wen; Pamela K. Allen; Anne Tsao; M Gillin; Radhe Mohan; James D. Cox

The authors sought to improve the toxicity of conventional concurrent chemoradiation therapy for stage III nonsmall cell lung cancer (NSCLC) by using proton‐beam therapy to escalate the radiation dose to the tumor. They report early results of a phase 2 study of high‐dose proton therapy and concurrent chemotherapy in terms of toxicity, failure patterns, and survival.


Medical Physics | 2006

Monte Carlo study of photon fields from a flattening filter-free clinical accelerator

Oleg N. Vassiliev; U Titt; Stephen F. Kry; Falk Pönisch; M Gillin; Radhe Mohan

In conventional clinical linear accelerators, the flattening filter scatters and absorbs a large fraction of primary photons. Increasing the beam-on time, which also increases the out-of-field exposure to patients, compensates for the reduction in photon fluence. In recent years, intensity modulated radiation therapy has been introduced, yielding better dose distributions than conventional three-dimensional conformal therapy. The drawback of this method is the further increase in beam-on time. An accelerator with the flattening filter removed, which would increase photon fluence greatly, could deliver considerably higher dose rates. The objective of the present study is to investigate the dosimetric properties of 6 and 18 MV photon beams from an accelerator without a flattening filter. The dosimetric data were generated using the Monte Carlo programs BEAMnrc and DOSXYZnrc. The accelerator model was based on the Varian Clinac 2100 design. We compared depth doses, dose rates, lateral profiles, doses outside collimation, total and collimator scatter factors for an accelerator with and without a flatteneing filter. The study showed that removing the filter increased the dose rate on the central axis by a factor of 2.31 (6 MV) and 5.45 (18 MV) at a given target current. Because the flattening filter is a major source of head scatter photons, its removal from the beam line could reduce the out-of-field dose.


Applied Physics Letters | 2011

Enhanced relative biological effectiveness of proton radiotherapy in tumor cells with internalized gold nanoparticles

J Polf; Lawrence Bronk; Wouter Driessen; Wadih Arap; Renata Pasqualini; M Gillin

The development and use of sensitizing agents to improve the effectiveness of radiotherapy have long been sought to improve our ability to treat cancer. In this letter, we have studied the relative biological effectiveness of proton beam radiotherapy on prostate tumor cells with and without internalized gold nanoparticles. The effectiveness of proton radiotherapy for the killing of prostate tumor cells was increased by approximately 15%-20% for those cells containing internalized gold nanoparticles.


Medical Physics | 2009

The M. D. Anderson proton therapy system

Alfred R. Smith; M Gillin; M Bues; X. Ronald Zhu; Kazumichi Suzuki; Radhe Mohan; Shiao Y. Woo; Andrew G. Lee; Ritsko Komaki; James D. Cox; Kazuo Hiramoto; Hiroshi Akiyama; Takayuki Ishida; Toshie Sasaki; Koji Matsuda

PURPOSE The purpose of this study is to describe the University of Texas M. D. Anderson proton therapy system (PTC-H) including the accelerator, beam transport, and treatment delivery systems, the functionality and clinical parameters for passive scattering and pencil beam scanning treatment modes, and the results of acceptance tests. METHODS The PTC-H has a synchrotron (70-250 MeV) and four treatment rooms. An overall control system manages the treatment, physics, and service modes of operation. An independent safety system ensures the safety of patients, staff, and equipment. Three treatment rooms have isocentric gantries and one room has two fixed horizontal beamlines, which include a large-field treatment nozzle, used primarily for prostate treatments, and a small-field treatment nozzle for ocular treatments. Two gantry treatment rooms and the fixed-beam treatment room have passive scattering nozzles. The third gantry has a pencil beam scanning nozzle for the delivery of intensity modulated proton treatments (IMPT) and single field uniform dose (SFUD) treatments. The PTC-H also has an experimental room with a fixed horizontal beamline and a passive scattering nozzle. The equipment described above was provided by Hitachi, Ltd. Treatment planning is performed using the Eclipse system from Varian Medical Systems and data management is handled by the MOSAIQ system from IMPAC Medical Systems, Inc. The large-field passive scattering nozzles use double scattering systems in which the first scatterers are physically integrated with the range modulation wheels. The proton beam is gated on the rotating range modulation wheels at gating angles designed to produce spread-out-Bragg peaks ranging in size from 2 to 16 g/cm2. Field sizes of up to 25 x 25 cm2 can be achieved with the double scattering system. The IMPT delivery technique is discrete spot scanning, which has a maximum field size of 30 x 30 cm2. Depth scanning is achieved by changing the energy extracted from the synchrotron (energy can be changed pulse to pulse). The PTC-H is fully integrated with DICOM-RT ION interfaces for imaging, treatment planning, data management, and treatment control functions. RESULTS The proton therapy system passed all acceptance tests for both passive scattering and pencil beam scanning. Treatments with passive scattering began in May 2006 and treatments with the scanning system began in May 2008. The PTC-H was the first commercial system to demonstrate capabilities for IMPT treatments and the first in the United States to treat using SFUD techniques. The facility has been in clinical operation since May 2006 with up-time of approximately 98%. CONCLUSIONS As with most projects for which a considerable amount of new technology is developed and which have duration spanning several years, at project completion it was determined that several upgrades would improve the overall system performance. Some possible upgrades are discussed. Overall, the system has been very robust, accurate, reproducible, and reliable. The authors found the pencil beam scanning system to be particularly satisfactory; prostate treatments can be delivered on the scanning nozzle in less time than is required on the passive scattering nozzle.

Collaboration


Dive into the M Gillin's collaboration.

Top Co-Authors

Avatar

Narayan Sahoo

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

X Zhu

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Radhe Mohan

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

F Poenisch

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Heng Li

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Xiaodong Zhang

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

U Titt

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

R Wu

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

X. Ronald Zhu

University of Texas MD Anderson Cancer Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge