M.J. Garcia
Polytechnic University of Catalonia
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by M.J. Garcia.
instrumentation and measurement technology conference | 2004
Daniel Mitrani; José Antonio Tomé; J. Salazar; A. Turo; M.J. Garcia; J.A. Chavez
The fundamental temperature-dependent parameters of a thermoelectric (TE) module: coefficient, electrical resistance, thermal conductance, and figure-of-merit are necessary, among other factors, for the conception of models for this type of devices. In this work we present a methodology for calculating these parameters from observable variables, which are obtained from temperature, voltage, and electric current measurements made on a working TE devices. The extracted parameters are plotted against the average temperature between the hot and cold side of the module. Results are verified by inserting average-value parameters into an electro-thermal SPICE model of a thermoelectric module and comparing simulation and measured (using a TE module characterization system) results for a given test configuration.
Microelectronics Journal | 2009
Daniel Mitrani; J. Salazar; A. Turo; M.J. Garcia; J.A. Chavez
Based on simplified one-dimensional steady-state analysis of thermoelectric phenomena and on analogies between thermal and electrical domains, we propose both lumped and distributed parameter electrical models for thermoelectric devices. A couple of important advantages of the presented models are that the temperature dependence of material properties is considered and that they can be easily simulated using an electronic simulation tool such as SPICE. For a single free-standing pellet, comparisons are made between SPICE simulations using the proposed models and with numerical simulations carried out with Mathematica software. Results illustrate accuracy of the distributed parameter models and show how inappropriate it is to assume, in some cases, constant material parameters for an entire thermoelectric element.
Microelectronics Journal | 2009
Daniel Mitrani; J. Salazar; A. Turo; M.J. Garcia; J.A. Chavez
This paper describes a one-dimensional distributed parameter transient model for thermoelectric devices implemented using analogies between the thermal and electrical domains, where thermal variables are described by their electrical analogues. The resulting electrical network can be tested by means of an electrical simulation tool such as SPICE. This approach facilitates simulation of a thermoelectric module and its interconnections with electronic control circuits and other thermal elements under varying boundary and initial conditions. Capabilities of the model are illustrated from simulations carried out for a free-standing thermoelectric element during the pulse cooling operation. Simulation results fit well with those obtained using other models reported in the literature as well as with numerical solutions.
instrumentation and measurement technology conference | 2001
J. Salazar; A. Turo; J.A. Chavez; J.A. Ortega; M.J. Garcia
This paper describes the design and development of a high-power high-resolution pulser designed especially for air-coupled ultrasonic NDE applications requiring high material penetration capability. The pulser can deliver up to 800 V in a spike excitation type pulse to appropriate low/medium frequency transducers. Moreover, the pulser operates in three different modes: single pulse, double pulse (pulse cancellation technique) and external reference signal, where the last two operating modes are intended to enhance the resolution of ultrasonic inspections.
internaltional ultrasonics symposium | 2002
J. Salazar; J.M. Álava; S.S. Sahi; A. Turo; J.A. Chavez; M.J. Garcia
Automation of the food industry requires fast and reliable measurements of the physical properties of materials during processing. The mixture of wheat flour, water, yeast and other ingredients produces a dough with specific viscoelastic characteristics capable of retaining gas and producing aerated goods. Within the baking industry, the control of dough properties is required to achieve final product quality and consistency. Traditional methods for dough testing are slow and off-line and do not provide fundamental rheological information. There is therefore a need for the development of fast and on-line instruments capable of providing relevant data for baking. Ultrasonics provides a nondestructive, rapid and low cost technique for the measurement of physical food characteristics. In this work, the rheological properties of dough are investigated using ultrasonic techniques. The measurements are correlated with dough quality tests. A common protocol for dough preparation is used for each type of measurement. Experimental results on different flour quality, water content and dough processing are presented. The relationship between measured ultrasonic parameters and final product quality is discussed.
international workshop on thermal investigations of ics and systems | 2007
Daniel Mitrani; J. Salazar; A. Turo; M.J. Garcia; J.A. Chavez
Based on simplified one-dimensional steady-state analysis of thermoelectric phenomena and on analogies between thermal and electrical domains, we propose both lumped and distributed parameter electrical models for thermoelectric devices. For lumped parameter models, constant values for material properties are extracted from polynomial fit curves evaluated at different module temperatures (hot side, cold side, average, and mean module temperature). For the case of distributed parameter models, material properties are calculated according to the mean temperature at each segment of a sectioned device. A couple of important advantages of the presented models are that temperature dependence of material properties is considered and that they can be easily simulated using an electronic simulation tool such as SPICE. Comparisons are made between SPICE simulations for a single-pellet module using the proposed models and with numerical simulations carried out with Mathematica software. Results illustrate accuracy of the distributed parameter models and show how inappropriate is to assume, in some cases, constant material parameters for an entire thermoelectric element.
internaltional ultrasonics symposium | 2005
J. García-Álvarez; J.M. Rodriguez; Y. Yañez; A. Turo; J.A. Chavez; M.J. Garcia; J. Salazar
Both flour strength and dough processing affect the dough consistency that determines its potential for breadmaking purposes. Quick identification of poor dough quality would reduce problems with dough handling during further stages of the process and maximise productivity. Maintaining consistent production would contribute to better control of product quality and consequently lead to high levels of customer satisfaction. Ultrasonic measurements have already been carried out to characterise dough properties. The ultrasonic wave parameters generally measured include the velocity of propagation and the attenuation of the acoustic wave traveling through the sample. These measurements can be related to both viscoelastic and physical properties of the sample, providing the flour strength. However, due to the time-dependent nature of dough accurate measurements of the ultrasonic velocity and attenuation are sometimes difficult to attain especially in highly attenuating materials like dough. Furthermore, due to viscoelastic properties of dough when a sample is placed between both transducers it slowly flows away from the transducer surface producing changes in the values of the ultrasonic velocity and attenuation with time. The greater these changes are the softer the dough is. This makes necessary a settling time in order to get an accurate measurement. In this work, an alternative method for evaluating the flour strength using low intensity ultrasound is shown. The evolution with time of both velocity and attenuation is monitored and then related to the flour strength. Main advantage of this novel approach is that changes in time of ultrasonic velocity and attenuation are easy to monitor than carry out accurate measurements of them after a settling time. Experimental results on doughs with different flour strength are presented, compared and discussed. Automation of the food industry requires fast and reliable measurements of the physical properties of materials during processing. The mixture of wheat flour, water, yeast and other ingredients produces a dough with specific viscoelastic characteristics capable of retaining gas and producing aerated goods. Within the baking industry, the control of dough properties is required to achieve final product quality and consistency. Traditional methods for dough testing are slow and off-line and do not provide fundamental rheological information. There is therefore a need for the development of fast and on-line instruments capable of providing relevant data for baking. The ultrasonic wave parameters generally measured include the velocity of propagation and the attenuation of the acoustical wave traveling through the sample. These can be related to various of its physical properties. Sensors and instruments based on non-contact methods are especially attractive to the food industry to be employed in quality assurance, process control and non-destructive inspection (1-3), for being both hygienic and easy to maintain. However, there is still a need to develop new techniques that can perform precise evaluations of dough and flour quality. Currently, there are only a few studies using ultrasound for characterising flour-water systems (4-9). In this paper, the ultrasonic measurements of velocity and attenuation are used for the classification of flours intended for different purposes and are compared with conventional flour testing methods. The time-dependence of the mechanical properties of dough is also studied and the results are related to flour strength. The purpose of this study is to determine the potential of ultrasound for use to predict flour and dough quality by millers and bakers by means the determination of flour strength. Section II gives a short outline of the experimental procedure and set-up used during the experiments. In Section III the experimental results are explained and discussed in detail. Finally, conclusions are made in Section IV.
international conference on telecommunications | 2003
Daniel Mitrani; J.A. Tome; J. Salazar; A. Turo; M.J. Garcia; J.A. Chavez
A simple and easy-to-use device for measuring thermoelectric module (TEM) properties is presented. The characterization system provides continuous direct measurement of TEM hot and cold side temperatures, electric current flow, and terminal voltage. Seebeck voltage is measured using the Harman method. These measurements are then used to obtain dynamic values of TEM fundamental parameters: electrical resistance, thermal conductance and Seebeck coefficient, from which the TEM figure-of-merit can be calculated. Test conditions, i.e., current flowing through the module can be varied by the user. The thermal circuit used by the characterization system includes an auxiliary TEM that enables to emulate a controlled ambient temperature, which increments the repeatability and versatility of each test. Additionally, the dynamic response can be varied by interchanging the thermal load. Repeatability tests show a dispersion between direct measurements of less than 50mK for temperature measurements and less than 4mV for voltage measurements.
IEEE Transactions on Instrumentation and Measurement | 1997
J.A. Chavez; J.A. Ortega; M.A. Perez; M.J. Garcia
A low cost conditioning structure for PbSe photoconductor arrays with few components is described. We use a PbSe array of 64 pixels in a simultaneous atmospheric pollutant detector of several gases. The sensor system is based on infrared optical absorption spectroscopy. The authors present a second version of the sensor. From the first version they deduced: i) it is necessary to work at high chopper frequencies to reduce the effect of 1/f noise, ii) it is necessary to provide a conditioning circuit for each channel, and iii) the conditioning interface must be near the array. Therefore, they propose to amplify and mix the incoming signal to produce a signal at a fixed intermediate frequency (IF), in their case 1 Hz. The fact that the circuit has few components makes possible to place 64 conditioners in a small volume (10/spl times/4.9/spl times/7.6 cm/sup 3/) using the with SMT technique. The conditioner is divided into eight boards. Each board has eight channels and an analog multiplexor. These characteristics permit to approach the circuitry to the array. Each channel conditioner has up to 100 dB voltage gain. The low IF technique makes it possible to have high-performance circuits with low-cost components.
instrumentation and measurement technology conference | 2001
M.J. Garcia; J.A. Ortega; J.A. Chavez; J. Salazar; A. Turo
The theory of operation of a fiber-optic-based strain sensor system, suitable for long structures, is described. The proposed sensor design is composed of several hundreds of sections separated by reflectors in order to monitor structures of more than 1 km of length. A quasi-distributed sensor structure accomplishes the best condition monitoring, where each section of the sensor integrates the measured magnitude, obtaining a value associated to the average shortening or elongation in this section. Tools for the design of the optical reflectors of the sensor are also provided, including a study of the optical noise due to multireflection within the system.