Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where M. Mishina is active.

Publication


Featured researches published by M. Mishina.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1999

Review of the development of diamond radiation sensors

Wolfgang Adam; C. Bauer; E. Berdermann; P. Bergonzo; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; E. Grigoriev; G. Hallewell; R. Hall-Wilton; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania

Abstract Diamond radiation sensors produced by chemical vapour deposition are studied for the application as tracking detectors in high luminosity experiments. Sensors with a charge collection distance up to 250 μm have been manufactured. Their radiation hardness has been studied with pions, proton and neutrons up to fluences of 1.9×10 15 π cm −2 , 5×10 15 p cm −2 and 1.35×10 15 n cm −2 , respectively. Diamond micro-strip detectors with 50 μm pitch have been exposed in a high-energy test beam in order to investigate their charge collection properties. The measured spatial resolution using a centre-of-gravity position finding algorithm corresponds to the digital resolution for this strip pitch. First results from a strip tracker with a 2×4 cm 2 surface area are reported as well as the performance of a diamond tracker read out by radiation-hard electronics with 25 ns shaping time. Diamond pixel sensors have been prepared to match the geometries of the recently available read-out chip prototypes for ATLAS and CMS. Beam test results are shown from a diamond detector bump-bonded to an ATLAS prototype read-out. They demonstrate a 98% bump-bonding efficiency and a digital resolution in both dimensions.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000

Pulse height distribution and radiation tolerance of CVD diamond detectors

Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; W. Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; E. Grigoriev; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania

The paper reviews measurements of the radiation tolerance of CVD diamond for irradiation with 24 GeV/c protons, 300 MeV/c pions and 1 MeV neutrons. For proton and neutron irradiation, the measured charge signal spectrum is compared with the spectrum calculated by a model. Irradiation by particles causes radiation damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model shows that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. In addition, we observed after proton irradiation at the charge signal spectrum a decrease of the number of small signals. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal. (11 refs).


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2003

Status of the R&D activity on diamond particle detectors

Wolfgang Adam; B. Bellini; E. Berdermann; P. Bergonzo; W. De Boer; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; W. Dabrowski; P. Delpierre; J. Doroshenko; W. Dulinski; B. Van Eijk; A. Fallou; P. Fischer; F. Fizzotti; C. Furetta; K. K. Gan; N. Ghodbane; E. Grigoriev; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan

Chemical Vapor Deposited (CVD) polycrystalline diamond has been proposed as a radiation-hard alternative to silicon in the extreme radiation levels occurring close to the interaction region of the Large Hadron Collider. Due to an intense research effort, reliable high-quality polycrystalline CVD diamond detectors, with up to 270μm charge collection distance and good spatial uniformity, are now available. The most recent progress on the diamond quality, on the development of diamond trackers and on radiation hardness studies are presented and discussed.


nuclear science symposium and medical imaging conference | 1998

Tracking with CVD diamond radiation sensors at high luminosity colliders

S. Schnetzer; Wolfgang Adam; C. Bauer; E. Berdermann; P. Bergonzo; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; W. Dabrowski; J. DaGraca; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; E. Grigoriev; G. Hallewell; R. Hall-Wilton; S. Han; F. Hartjes; J. Hrubec; D. Husson

Recent progress on developing diamond-based sensors for vertex detection at high luminosity hadron colliders is described. Measurements of the performance of diamond sensors after irradiation to fluences of up to 5/spl times/10/sup 15/ hadrons/cm/sup 2/ are shown. These indicate that diamond sensors will operate at distances as close as 5 cm from the interaction point at the Large Hadron Collider (LHC) for many years at full luminosity without significant degradation in performance. Measurements of the quality of the signals from diamond sensors as well as spatial uniformity are presented. Test beam results on measurements of diamond-based microstrip and pixels devices are described.


Diamond and Related Materials | 2001

CVD diamond sensors for charged particle detection

M. Krammer; Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania

Abstract CVD diamond material was used to build position-sensitive detectors for single-charged particles to be employed in high-intensity physics experiments. To obtain position information, metal contacts shaped as strips or pixels are applied to the detector surface for one- or two-dimensional coordinate measurement. Strip detectors 2×4 cm2 in size with a strip distance of 50 μm were tested. Pixel detectors of various pixel sizes were bump bonded to electronics chips and investigated. A key issue for the use of these sensors in high intensity experiments is the radiation hardness. Several irradiation experiments were carried out with pions, protons and neutrons exceeding a fluence of 1015 particles/cm2. The paper presents an overview of the results obtained with strip and pixel detectors in high-energy test beams and summarises the irradiation studies.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2002

Performance of irradiated CVD diamond micro-strip sensors

Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania; J. Kaplon

Abstract CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15 /cm 2 ) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2×10 15 p / cm 2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9×10 15 π / cm 2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000

Micro-strip sensors based on CVD diamond

Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania; J. Kaplon

Abstract In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1998

STATUS OF DIAMOND PARTICLE DETECTORS

M. Krammer; Wolfgang Adam; C. Bauer; E. Berdermann; F. Bogani; E. Borchi; M. Bruzzi; C. Colledani; J. Conway; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; D. Fish; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; E. Grigoriev; G. Hallewell; R. Hall-Wilton; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D. R. Kania; J. Kaplon

Abstract To continue the exciting research in the field of particle physics new accelerators and experiments are under construction. In some of these experiments, e.g. ATLAS and CMS at the Large Hadron Collider at CERN or HERA-B at DESY, the detectors have to withstand an extreme environment. The detectors must be radiation hard, provide a very fast signal, and be as thin as possible. The properties of CVD diamond allow to fulfill these requirements and make it an ideal material for the detectors close to the interaction region of these experiments, i.e. the vertex detectors or the inner trackers. The RD42 collaboration is developing diamond detectors for these applications. The program of RD42 includes the improvement of the charge collection properties of CVD diamond, the study of the radiation hardness and the development of low-noise radiation hard readout electronics. An overview of the progress achieved during the last years will be given.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2003

New results on diamond pixel sensors using ATLAS frontend electronics

W. Adam; E. Berdermann; P. Bergonzo; W. de Boer; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D’Angelo; W. Dabrowski; P. Delpierre; J. Doroshenko; W. Dulinski; B. Van Eijk; A. Fallou; P. Fischer; F. Fizzotti; C. Furretta; K. K. Gan; N. Ghodbane; E. Grigoriev; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; J. Kaplon

Abstract Diamond is a promising sensor material for future collider experiments due to its radiation hardness. Diamond pixel sensors have been bump bonded to an ATLAS pixel readout chip using PbSn solder bumps. Single chip devices have been characterised by lab measurements and in a high-energy pion beam at CERN. Results on charge collection, spatial resolution, efficiency and the charge carrier lifetime are presented.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2006

Radiation hard diamond sensors for future tracking applications

Wolfgang Adam; W. De Boer; E. Borchi; M. Bruzzi; C. Colledani; P. D’Angelo; V. Dabrowski; W. Dulinski; B. Van Eijk; V. Eremin; F. Fizzotti; H. Frais-Kölbl; C. Furetta; K. K. Gan; A. Gorišek; E. Griesmayer; E. Grigoriev; F. Hartjes; J. Hrubec; F. Huegging; H. Kagan; J. Kaplon; R. Kass; K.T. Knöpfle; M. Krammer; W. Lange; A. Logiudice; C. Manfredotti; M. Mathes; D. Menichelli

Collaboration


Dive into the M. Mishina's collaboration.

Top Co-Authors

Avatar

E. Borchi

University of Florence

View shared research outputs
Top Co-Authors

Avatar

M. Bruzzi

University of Florence

View shared research outputs
Top Co-Authors

Avatar

B. Van Eijk

University of Amsterdam

View shared research outputs
Top Co-Authors

Avatar

H. Kagan

Ohio State University

View shared research outputs
Top Co-Authors

Avatar

K. K. Gan

Ohio State University

View shared research outputs
Top Co-Authors

Avatar

A. Fallou

Ohio State University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J. Hrubec

Austrian Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

J. Conway

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

S. Han

Lawrence Livermore National Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge