M. Román Ceba
University of Granada
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by M. Román Ceba.
Trends in Analytical Chemistry | 1997
A. M. García Campaña; L. Cuadros Rodríguez; F. Alés Barrero; M. Román Ceba; J.L.Sierra Fernández
Abstract ALAMIN is a DOS program that establishes the performance characteristics of the analytical method from the calibration data set. It allows an estimation of the maximum level of interferents that causes a bias equal to or greater than the random error of determination. A statistical protocol checks the trueness of the analytical method by standard addition methodology. This shareware program is available from the authors upon request.
Analytica Chimica Acta | 1997
A. M. García Campaña; L. Cuadros Rodríguez; A.Lupiáñez González; F. Alés Barrero; M. Román Ceba
Abstract In this paper, the use of Doehlert designs for the optimization of three experimental variables is proposed. Sequential response surface methodology is based on a strategy to obtain a quadratic function relationship between the response and the significant variables using a three and five-level experimental design. The Doehlert design structure allows us to study this reponse surface by estimating the parameters of the quadratic model and thus, by building sequential designs, it is possible to obtain the region in which the optimum values of such variables are simultaneously obtained. The mobility of these designs across the experimental domain of the variables permits the use of data from a previous design for a new design, obtained by response variation for the other two variables. The principle of this methodology is described and an example of its application in a spectrofluorimetric method is given.
Analytical Letters | 1994
C. Cruces Blanco; A. Segura Carretero; A. Fernández Gutiérrez; M. Román Ceba
Abstract A spectrofluorimetric analysis of folic acid (pteroylglutamic acid) using fluorescamine as a fluorogenic reagent, has been developed. The analytical parameters for optimal reaction and sensitivity (pH, fluorescamine concentration, temperature, reaction time), have been studied. The present method may be employed for the analysis of small amounts of folic acid (< 20 ppb), without interferences from other compounds; the selectivity being increased by the application of the synchronous derivative technique to normal fluorescence spectra. The minimum detectable quantity, using the latter technique, is estimated to be 16 ppb, with a relative standard deviation of 2.7 % (10 determinations). A soft sport beverage, containing low concentrations of the vitamin, have been satisfactorily analyzed.
Talanta | 1995
C. Cruces Blanco; A. M. García Campaña; F. Alés Barrero; M. Román Ceba
The cationic surfactant hexadecyltrimethylammonium bromide enhances the fluorescence intensity of both molybdenum and tungsten complexes obtained with Alizarin Red S. This characteristic has been used for a sensitive simultaneous spectrofluorimetric determination of both ions over the range 32-4000 ng/ml and 49-2500 ng/ml for Mo and W, respectively. Good selectivity is achieved applying the well known synchronous derivative technique with a minucious pH selection. The proposed method has been applied to a certified steel sample with recoveries between 96 and 102%.
Analytical Letters | 1995
A. M. García Campaña; L. Cuadros Rodríguez; C. Jimenez Linares; F. Alés Barrero; M. Román Ceba
Abstract A model to estimate the tolerance level of interfering substances for analytical procedures, applying the linear simple regression, is proposed. The confidence interval on the analytical signal for the selected concentration value to check the interference, is calculated using the calibration data set. The tolerance levels of molybdenum, aluminium and iron in the spectro fluorimetric determination of boron with Alizarin Red S by means of direct, synchronous and first- and second-derivative methods, are estimated. The adequate selection of an analyte concentration for the interferent test is discussed.
Talanta | 1986
A.Arrebola Ramirez; C. Jimenez Linares; F. Alés Barrero; M. Román Ceba
Mixtures of La(III) and Mg(II) form with purpurin (P; 1,2,4-trihydroxyanthraquinone) the mixed-metal complex LaMg(2)P(5), which is extracted with methyl isobutyl ketone at pH 7.5. The molar absorptivity of the complex is 6.1 x 10(4) l.mole(-1).cm(-1) at 570 nm and its conditional extraction constant 5 x 10(13) l(4).mole(-4). Similar complexes have been found to be formed with yttrium, cerium, praseodymium, neodymium and samarium. The use of these complexes for the spectrophotometric determination of yttrium and lanthanides up to 15 mug has been investigated.
Analytica Chimica Acta | 2001
Ana M. García-Campaña; F. Alés Barrero; A.Lupiáñez González; M. Román Ceba
A spectrofluorometric method is described for the determination of germanium(IV) based on its complexation reaction with quercetin in presence of Brij-35. The fluorescence is monitored at 552 nm with excitation at 432 nm. The pH, quercetin and Brij-35 concentrations were optimized simultaneously using the response surface methodology from sequential experimental three-variable Doehlert designs. Interferences in this determination have been studied. The detection limit is 7.4 ng ml −1 and the linear range is between 7.4 and 150 ng ml −1 . The method has been applied to the determination of germanium in a drug and in wholemeal oats.
Analytica Chimica Acta | 1993
C. Cruces Blanco; A. M. García Campaña; F. Alés Barrero; M. Román Ceba
Abstract A method is described for the simultaneous determination of molybdenum and boron in plant leaves, based on the highly sensitive fluorescence reaction with Alizarin Red S. Simplicity is achieved by using first and second derivatives of the synchronous spectra. Appropriate calibration equations were established between 0.1–0.9 and 0.3–0.7 μg ml−1 for molybdenum and boron, respectively, with a mean relative standard deviation of 2.2%.
Journal of Pharmaceutical and Biomedical Analysis | 1995
C. Cruces Blanco; A. Segura Carretero; A. Fernández Gutiérrez; M. Román Ceba
Abstract A sensitive and inexpensive micellar-enhanced synchronous-derivative spectrofluorimetric method is described for the determination of folic acid in pharmaceutical preparations. The method is based upon derivatization of the vitamin with fluorescamine in acid solution and enhancement of the fluorescence with a surfactant. Linear fluorimetric analytical curves were obtained for folic acid concentrations of 0.05–6 μg ml−1 (detection limit 0.012 μg ml−1); the RSD for 1 μg ml−1 of folic acid was 2.82%. The method has been applied to the determination of folic acid synthetic mixtures and pharmaceutical preparations.
Analyst | 1994
A. M. García Campaña; F. Alés Barrero; M. Román Ceba; A. Fernández Gutiérrez
A sensitive method for the spectrofluorimetric determination of Mo with Alizarin Red S, in the presence of hexadecyltrimethylammonium bromide, is described. The complex is formed at pH 4.7 in micellar medium, and the fluorescence intensity develops immediately. The detection limit is 1.7 ng cm–3 and the linear range is between 6 and 1000 ng cm–3. The influence of several ions, as interferents, is discussed. The proposed method has been applied to the determination of Mo in vegetal tissues and in a pharmaceutical compound.