M.T. Oms
University of the Balearic Islands
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by M.T. Oms.
Analytica Chimica Acta | 1996
M.T. Oms; Amalia Cerdà; A. Cladera; Víctor Cerdà; R. Forteza
The design of an analytical system based on the coupling of gas-diffusion separation and sequential injection analysis is described and applied to ammonium determination. The sample and an alkaline solution are sequentially aspirated using an automatic burette and mixed by flow reversal while they are being propelled to a gas-diffusion unit. There, the ammonia formed diffuses through an hydrophobic membrane into an acid-base indicator solution. The change in the absorbance of the acid-base indicator solution used as acceptor stream is measured and referred to ammonium content in the sample. The system requiring simple and commonly available instrumentation is automated and has been applied to the determination of ammonium in environmental samples.
Analytica Chimica Acta | 1995
M.T. Oms; Amalia Cerdà; Víctor Cerdà
Abstract A sequential injection system for the analysis of nitrate and nitrite is described. The sample and reagents are aspirated and mixed by flow reversal while being propelled to a reaction coil or to the detector. The determination of nitrite is based on the Griess-llosvay reaction. Nitrate is previously reduced by hydrazine in alkaline medium and analyzed as nitrite. The sequencing and overlap of the stacked zones are key parameters that have been studied together with concentrations of reagents, influence of temperature and potential interfering ions. Under the final optimal conditions up to 400 μM of nitrite and nitrate can be analyzed, the detection limits being 0.07 ppm and 0.2 ppm respectively. The method has been tested with prepared standard samples, atmospheric aerosol filter extracts and wastewater samples.
Trends in Analytical Chemistry | 2001
Víctor Cerdà; Amalia Cerdà; A. Cladera; M.T. Oms; F. Mas; E. Gómez; F Bauzá; Manuel Miró; R. Forteza; J.M. Estela
The use of sequential injection analysis (SIA), as applied to the control of environmental parameters, is reviewed. Its advantages and drawbacks are compared with those of flow injection analysis (FIA). FIA is simpler and easier to handle, has a higher sample throughput, and may be controlled manually, but SIA is more robust and versatile and better adapted for multiparametric and stopped flow techniques.
Analytica Chimica Acta | 1995
Amalia Cerdà; M.T. Oms; R. Forteza; Víctor Cerdà
A comparative study of flow injection methods for the determination of ammonium ion in wastewater samples is presented. It includes methods based on the Berthelot reaction and methods based on gas diffusion. Detection is either spectrophotometric or conductimetric. Analytical characteristics of each method are described in terms of reproducibility, sensitivity and selectivity. The performance of several gas permeable membranes to be used in gas-diffusion systems is discussed. The stopped flow approach is also investigated in order to improve the detection limits. Calibration graphs are obtained for each system, with and without that preconcentration step. Finally, a number of wastewater samples are analyzed using the described methods and the results are compared.
Analytica Chimica Acta | 1990
F. García Sánchez; A.L. Ramos Rubio; Víctor Cerdà; M.T. Oms
Abstract The application of a program written in BASIC for an IBM/PC interfaced with a commercial spectrofluorimeter enables variable-angle scanning fluorescence spectra to be obtained, without modification of the instrument. The technique is effective for determinations of the components of mixtures of carbaryl, fuberidazol and warfarin, all of which are pesticides with intrinsic fluorescence and closely overlapping profiles. The proposed method permitted simultaneous determinations with RSD of less than 2.5% and recoveries of 99–110%.
Analyst | 1996
Amalia Cerdà; M.T. Oms; R. Forteza; Víctor Cerdà
A rapid method for the sequential determination of nitrite, nitrate and total nitrogen is proposed. Nitrite was determined directly by using the Griess reaction, which was also used to quantify nitrate after reduction to nitrite with hydrazine. For total nitrogen determination, the nitrogen-containing compounds (organic substances and nitrite and ammonium ions) were oxidized photochemically using a UV lamp and converted into nitrate, which was then reduced to nitrite and determined spectrophotometrically. Under the optimized conditions, up to 220 µmol l–1 N-NO2– and 240 µmol l–1 N-NO3– can be determined, the detection limits being 2 µmol l–1 N-NO2– and 8 µmol l–1 N-NO3–. The relative standard deviation for nitrite and nitrate are 1.5 and 2.3%, respectively. The photo-oxidation method for total nitrogen determination has a linear range of 30–1000 µmol l–1 N, with a relative standard deviation of 3%. The proposed method was applied to the determination of nitrate, nitrite and total nitrogen in wastewaters.
Analytica Chimica Acta | 1997
Amalia Cerdà; M.T. Oms; R. Forteza; Víctor Cerdà
Abstract A method for the determination of total nitrogen in wastewaters involving flow injection and on-line microwave-assisted digestion is described. The method is based on the oxidation of nitrogen-containing compounds to nitrate by means of peroxodisulfate using a microwave oven as a radiation source. Nitrate is determined by the Griess-Ilosvay reaction, after reduction to nitrite by hydrazine under alkaline conditions, using sulfanilamide and N -(1-naphthyl) ethylene diamine. A thorough study of the factors affecting the digestion process has been carried out using several nitrogen-containing compounds as test substances. Under the optimized conditions, the described method allows quantitative digestion of all the model compounds for concentrations up to 20 mg l −1 N. The method enables the analysis of 10 samples in triplicate per hour, the relative standard deviation (RSD) of 10 replicates being ca. 3%. The detection limit (3 × SD of blank) is 0.21 mg l −1 N. The system has been applied to the determination of total nitrogen in wastewaters and the results have been compared with those obtained by Kjeldahl digestion.
Talanta | 2003
M.T. Oms; Amalia Cerdà; Víctor Cerdà
An automatic method for the determination of total nitrogen in wastewater by sequential injection analysis and mineralization with UV radiation has been developed. The method is based on the mineralization of the samples with sodium persulphate in basic medium under UV radiation. Small volumes of sample and reagents are firstly aspirated into a single channel and then propelled by flow reversal to the UV reactor and then to the detector. The organic and inorganic nitrogen compounds are oxidized to nitrate that is then measured at 226 nm. The sequential injection procedure has been optimized and the factors affecting the efficiency of the oxidation have been studied with a number of test substances with different chemical structures and properties. Solutions in the concentration range 1-56 gl(-1) of nitrogen can be analyzed with the described procedure. The sample rate is of 30-40 samples h(-1). The LOD is 0.6 mgl(-1) N and the reproducibility is 1.8% (28 mgl(-1) N). Organic carbon in the form of glucose was added to a number of test solutions to study the potential interference of organic matter. The method was compared with the Kjeldahl digestion method by analyzing 15 wastewater samples with both methods. The nitrate and nitrite content of the non-oxidized samples were subtracted from the corresponding nitrogen content determined after photo-oxidation and the value compared with the Kjeldahl nitrogen content.
Analytica Chimica Acta | 1990
M.T. Oms; R. Forteza; Víctor Cerdà; S. Maspoch; J. Coello; M. Blanco
Abstract A procedure is described for the resolution of two-component mixtures by use of data from variable-angle fluorescence spectrometry. The experimental data are treated by multilinear regression. The method is applied to the resolution of mixtures of fluorescein and dichlorofluorescein at the ng ml −1 level; mean errors are
International Journal of Environmental Analytical Chemistry | 1990
M.T. Oms; R. Forteza; Víctor Cerdà; F. García; A. L. Ramos
Abstract The use of variable-angle fluorescence spectra together with multilinear curve-fitting techniques for the resolution of mixtures of polycyclic aromatic hydrocarbons (PAHs), is described. Only one spectrum is necessary to determine four compounds in a mixture even when a severe overlap occurs. The PAHs are quantified at ng/ml levels.