M.V.S. Rao
Tata Institute of Fundamental Research
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by M.V.S. Rao.
Indian Journal of Critical Care Medicine | 2015
Pradeep M. Venkategowda; S Manimala Rao; Dnyaneshwar P. Mutkule; M.V.S. Rao; Alai. N. Taggu
Background: Scrub typhus is one of the differential diagnoses for fever with thrombocytopenia. ARDS associated with Scrub typhus has high morbidity and mortality. Aims: To evaluate clinical features, lab values, and outcome in patients with scrub typhus and comparison in patients with or without ARDS. Methods: A prospective observational study was conducted on 109 patients with febrile illness and thrombocytopenia during a period of 12 months. All 109 patients were tested with both Immune-chromatography test and Weil felix test. Patients having either Immune-chromatography test/Weil felix test positive have been included and considered as scrub typhus positive whereas negative for both Immune-chromatography and Weil felix test were excluded. Clinical features, lab parameters, and outcome were evaluated in all patients with scrub typhus. Statistical analysis used in this study was T-test. Results: Among 58 patients who were included (After exclusion of 51 patients among total of 109 patients) 34 patients had no ARDS and 24 patients had ARDS. The clinical feature like dyspnoea, cough, low blood pressure (MAP<65 mmHg), IVC collapsibility (by ultrasound) and laboratory parameters like decreased Hemoglobin, Hematocrit, Serum albumin, and increased serum creatinine, serum total bilirubin, SGOT, SGPT, LDH, CPK, and serum lactate were statistically significant (P < 0.0001) in scrub typhus patients group with ARDS. The higher titers of Weil-felix can be correlated with more severe form of disease according to our observation. All 34 Scrub typhus patients without ARDS recovered completely. Among 24 Scrub typhus patients with ARDS, 22 patients recovered, and 2 patients died. Conclusion: Scrub typhus is an important differential diagnosis in a patients having fever with thrombocytopenia. Scrub typhus associated with ARDS has high morbidity and mortality. Early diagnosis and treatment with doxycycline can prevent the occurrence of ARDS
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1988
B. S. Acharya; S. Naranan; M.V.S. Rao; Kondagunta Umamaheswaram Sivaprasad; B. V. Sreekantan; Srikantha Rao
Abstract An experiment to determine the nature of primary cosmic rays of energy > 1014 eV by studying high energy (> 220 GeV) muons and their correlations with other parameters of extensive air showers generated by them, was carried out at Kolar Gold Fields, India (atmospheric depth of 920 g cm−2). An accurate estimate of shower parameters in showers as small as 104 particles was achieved by means of a closely packed array of large area detectors and by employing special methods of analysis. In this paper, the details of the array, the data recording system, the procedure of data analysis and error estimates are described.
Indian Journal of Critical Care Medicine | 2016
Pradeep M. Venkategowda; S Manimala Rao; Yogesh R. Harde; Mithilesh K. Raut; Dnyaneshwar P. Mutkule; Kartik Munta; M.V.S. Rao
Aim: To observe the 28 and 90 days mortality associated with prone position and assist control-pressure control (with inverse ratio) ventilation (ACPC-IRV). Materials and Methods: All patients who were admitted to our medical Intensive Care Unit (ICU) who are positive for H1N1 viral infection with severe acute respiratory distress syndrome (ARDS) and requiring invasive mechanical ventilation in prone position were included in our prospective observational study. Six patients who are positive for H1N1 required invasive ventilation in prone position. These patients were planned to ventilate in prone for 16 h and in supine for 8 h daily until P/F ratio >150 with FiO2 of 0.6 or less and positive end-expiratory pressure <10 cm of H2 O. Results: At admission, among these six patients the mean tidal volume generated was about 376.6 ml which was in the range of 6–8 ml/kg predicted body weight. The mean lung injury score was 3.79, mean PaO2 /FiO2 ratio was 52.66 and mean oxygenation index was 29.83. The mean duration of ventilation was 9.4 days (225.6 h). The ICU length of stay was 11.16 days. There was no mortality at 28 and 90 days. Conclusion: Early prone combined with ACPC-IRV in H1N1 patients having severe ARDS can be used as a rescue therapy and it should be confirmed by large observational studies.
High Energy Gamma−Ray Astronomy | 2008
B. S. Acharya; M.V.S. Rao; Kondagunta Umamaheswaram Sivaprasad; B. V. Sreekantan; P. R. Vishwanath
We report the first ever simultaneous burst of PeV energy radiation from a potential source. We recorded 35 showers against an expected background of 17.8, with the KGF air shower array, from Crab during 13:15-1600 UT 23 February 1989, the day on which the Baksan group reported a burst. The EASTOP group also reported excess on the same day. Our data show that the muon content of source showers is same as that in background showers. All three observations show correlation with the Crab pulsar period. These results suggest that either gamma ray interactions are similar to hadron interactions at PeV energies, or the primaries are neutrinos interacting with a large cross section predicted by some composite models or a hitherto unknown strongly interacting neutral particle with mass{lt}40 MeV c{sup {minus}2} is responsible for the events.
Gamma-ray bursts: 3rd Huntsville symposium | 2008
P. N. Bhat; Kondagunta Umamaheswaram Sivaprasad; B. S. Acharya; P. R. Vishwanath; M.V.S. Rao
Several Gamma Ray Bursts detected in the keV energy range by the Burst and Transient Source Experiment (BATSE) have been observed by the Energetic Gamma Ray Experiment Telescope (EGRET) in the MeV/GeV energy range. The energy spectra of γ-rays in some of the bursts continues from keV to GeV without a break or any evidence for a high energy cut-off. If the same slope continues up to the PeV range the expected γ-ray flux falls within the sensitivity of the Extensive Air Shower array operating at the Kolar Gold Fields, India. In view of the enormous astrophysical implications of the results, we have conducted a systematic search for PeV γ-rays from the locations of about 39 high fluence GRB’s detected during April 1991 and March 1993. The results of a search from 8 highest fluence GRB’s are presented here.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1995
B. S. Acharya; P.N. Bhat; Alexander V. St. John; S.G. Khairatkar; B. K. Nagesh; M.R. Rajeev; K. Shobha Rao; M.V.S. Rao; V.A. Reddy; Kondagunta Umamaheswaram Sivaprasad; S. Sinha; A.J. Stanislaus; P. Unnikrishnan; S. S. Upadhya; B.L. Venkateshmurthy; P. R. Vishwanath; K. Viswanathan
Abstract A computerised on-line data acquisition system has been implemented to acquire data and monitor all the detectors in an extensive air shower experiment at Kolar Gold Fields, India, designed to search for point sources of Ultra High Energy gamma rays. It is based on the LSI-11 microcomputer, which has a powerful instruction set and a daisy chained vectored interrupt facility. Two personal computers are linked with LSI-11 through a 16-bit communication bus, to transfer data for a quick analysis. While the system performs this function in the background, it can be interrupted, at different priority levels, by several foreground functions, such as event data acquisition, detector monitoring, etc. The hardware and software features of the data acquisition system are described in detail.
Nuclear Physics B - Proceedings Supplements | 1990
B. S. Acharya; P.N. Bhat; S.G. Khairatkar; M.R. Rajeev; M.V.S. Rao; S. Sinha; Kondagunta Umamaheswaram Sivaprasad; B. V. Sreekantan; S. C. Tonwar; P. R. Vishwanath; K. Viswanathan
Results on search for point sources based on the data collected from October 1984 to January 1987 from the EAS array at KGF are presented. The array has a pointing accuracy of better than 1.5° to look at point sources. We present upper limit on the long term flux of gamma rays from Cygnus-X3 and report possible episodic emission from Cyg X-3 and Her X-1 during 1985.
Physical Review D | 1981
B. S. Acharya; M.V.S. Rao; Kondagunta Umamaheswaram Sivaprasad; Srikantha Rao
Physical Review D | 1981
B. S. Acharya; M.V.S. Rao; Kondagunta Umamaheswaram Sivaprasad; Srikantha Rao
Lettere Al Nuovo Cimento | 1981
B. S. Acharya; M.V.S. Rao; Kondagunta Umamaheswaram Sivaprasad; Srikantha Rao
Collaboration
Dive into the M.V.S. Rao's collaboration.
Kondagunta Umamaheswaram Sivaprasad
Tata Institute of Fundamental Research
View shared research outputs