Mª Jesús Gismera
Autonomous University of Madrid
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Mª Jesús Gismera.
Journal of Environmental Management | 2012
Jaime Cuevas; Ana Isabel Ruiz; Isabel S. de Soto; Teresa Sevilla; Jesús R. Procopio; Pilar Da Silva; Mª Jesús Gismera; Mercedes Regadío; Nicanor Sánchez Jiménez; Manuel Rodríguez Rastrero; Santiago Leguey
In this paper, the diffusion of solutes in natural clay from a concentrated solution consisting primarily of ammonium, sodium and chloride ions at a pH level of 8 was studied and was based on an existing 20-year-old landfill. Contaminant transport through clay liners was predicted using transport and reaction geochemical codes to help explain the experimental data. The model predicted the chloride anion diffusion and cation exchange processes for three different experiments: (1) small-scale interactions in compacted clay, (2) 1:1 European Union (EU) Directive demonstration experiments (0.5-m-thick clay barrier), and (3) analysis of a bore hole with core recovery drilled in an old landfill located above a similar type of clay as that studied in (1) and (2). Orders of magnitude between 10(-10) and 10(-9) m(2) s(-1) were used for the apparent diffusion coefficient to fit the chloride profiles at the different scales; however, at larger space and time scales, diffusion was retarded due to the presence of more consolidated, non-mechanically disturbed clay materials at large depths in a natural clay-rock emplacement.
Talanta | 2013
Beatriz Gómez-Nieto; Mª Jesús Gismera; Mª Teresa Sevilla; Jesús R. Procopio
The simultaneous and direct determination of nickel and iron in plants and lichens has been investigated using high-resolution continuum source graphite furnace atomic absorption spectrometry. The primary resonance line for nickel at 232.003 nm and the adjacent secondary line for iron at 232.036 nm have been used for this purpose. The optimization of the experimental conditions was performed using a pine needles certified reference material (SRM 1575a). The influence of pyrolysis and atomization temperatures, the amount of solid sample introduced into the graphite furnace and the use of aqueous or solid standard for calibration were studied. The spectral interferences caused by absorption of the concomitants of the solid sample were detected and corrected using a least square algorithm. Aliquots of 0.1-1mg of the solid samples were weighed onto the solid sampling platforms and analyzed directly, without addition of any reagents. The limits of detection were 25 µg kg(-1) for nickel and 0.40 mg kg(-1) for iron and the precision, expressed as the relative standard deviation, ranged from 7% to 12%. The proposed method was used to determine both metals in different bioindicator samples with successful results.
Talanta | 2015
Alberto Cantalapiedra; Mª Jesús Gismera; Jesús R. Procopio; Mª Teresa Sevilla
A differential pulse anodic stripping voltammetric (DPASV) method, with an open circuit (OC) approach in the pre-concentration step has been developed for copper ion determination at very low concentration level using a sensor based on a polystyrene sulfonate-carbon nanopowders (PSS-CnP) composite. This composite material is easily prepared from ultrasonic assisted dispersions of CnP in aqueous solution of PSS. For preparation of sensor devices, a reproducible and inexpensive drop coating procedure of the surface of home-made pencil graphite electrodes (PGEs) using a CnP dispersion in PSS was performed. At the optimal conditions for accumulation (0.01molL(-1) KNO3 at pH 3) and measurement steps (a reduction potential of -0.5V for 60s and then, an anodic DPV scan) and using a pre-concentration time of 300s, the limit of detection was 0.11µgL(-1) (1.73nM). This OC-DPASV method using the PSS-CnP-PGE sensor was successfully employed for Cu(II) determination in mineral, river and sea water samples.
Analytica Chimica Acta | 2015
Beatriz Gómez-Nieto; Mª Jesús Gismera; Mª Teresa Sevilla; Jesús R. Procopio
The fast sequential multi-element determination of 11 elements present at different concentration levels in environmental samples and drinking waters has been investigated using high-resolution continuum source flame atomic absorption spectrometry. The main lines for Cu (324.754 nm), Zn (213.857 nm), Cd (228.802 nm), Ni (232.003 nm) and Pb (217.001 nm), main and secondary absorption lines for Mn (279.482 and 279.827 nm), Fe (248.327, 248.514 and 302.064 nm) and Ca (422.673 and 239.856 nm), secondary lines with different sensitivities for Na (589.592 and 330.237 nm) and K (769.897 and 404.414 nm) and a secondary line for Mg (202.582 nm) have been chosen to perform the analysis. A flow injection system has been used for sample introduction so sample consumption has been reduced up to less than 1 mL per element, measured in triplicate. Furthermore, the use of multiplets for Fe and the side pixel registration approach for Mg have been studied in order to reduce sensitivity and extend the linear working range. The figures of merit have been calculated and the proposed method was applied to determine these elements in a pine needles reference material (SRM 1575a), drinking and natural waters and soil extracts. Recoveries of analytes added at different concentration levels to water samples and extracts of soils were within 88-115% interval. In this way, the fast sequential multi-element determination of major and minor elements can be carried out, in triplicate, with successful results without requiring additional dilutions of samples or several different strategies for sample preparation using about 8-9 mL of sample.
Analytica Chimica Acta | 2009
Raúl A. Sánchez-Moreno; Mª Jesús Gismera; Mª Teresa Sevilla; Jesús R. Procopio
A new and easy device for direct detection of chromium(III) in batch and flow analysis without previous oxidation/reduction or preconcentration steps of samples is designed and evaluated. For this purpose a potentiometric sensor with solid state membrane based on carbon paste matrix is developed. The sensor is modified with di(2-hydroxyphenylimino)ethane and the principal analytical parameters of the potentiometric response in batch and flow analysis are optimized and calculated. Optimal detection limits (1.4 x 10(-7)M in static mode and 5.4 x 10(-7)M in on-line analysis) and selectivity to trivalent chromium are obtained in both analysis modes. The use of this device to direct detection of chromium(III) in real samples is tested using a sediment Certified Reference Material. Chromium(III) determination is also carried out with successful results in environmental samples such as extracts from soils used as barriers in landfills and industrial samples such as waste waters from electroplating industries.
Talanta | 2007
Mª Jesús Gismera; Mª Teresa Sevilla; Jesús R. Procopio
A new carbon paste electrode modified with tetramethyl thiuram disulfide is prepared to use as copper potentiometric sensor in batch and flow analysis. The influence of pH and carbon paste composition on the potentiometric response is studied. The principal parameters of the flow system are optimized and the detection limits and the selectivity coefficients of the potentiometric sensor are calculated for static and flow mode. In both cases, the sensor shows high selectivity to copper ions but in flow analysis this selectivity is higher. The obtained detection limits are 4.6 x 10(-8) M for batch measurements and 2.0 x 10(-7) M for on-line analysis. The potentiometric sensor is applied to copper(II) determination in real samples in static and flow measurements. In both analysis modes, successful results are obtained.
Science of The Total Environment | 2013
Mercedes Regadío; I. de Soto; M Rodriguez-Rastrero; Ana Isabel Ruiz; Mª Jesús Gismera; Jaime Cuevas
Analyses of substratum samples under a landfill were performed to assess the pollution impact of waste over a clay-sand material after nine years of exposure. These samples presented different illite/kaolinite ratios and an acid pH, especially low near the waste/soil contact in a 1-1.5 m soil thickness with low density and despite the basic pH of the collected actual methanogenic leachate. This study has raised the effects of a presumably acid stage in the waste leachate on the substratum final quality of clay and its physical-chemical properties as an attenuation buffer. These effects were the dissolution of carbonate minerals, decrease of dry density, increase of hydraulic conductivity, release of metals and formation of clays with low cationic exchange capacity (CEC) as kaolinite. The large presence of H(+) and Al(OH)(3-x)(x+) depleted the neutralizing capacity of the substratum and occupied exchangeable sites, decreasing therefore the available sites for retaining leachate pollutants, which traveled further than the first-meter depth of the substratum. In order to combat and prevent pollution as well as to preserve the good barrier properties under new landfills it is proposed to select illitic materials better than kaolinitic substratum, to avoid acid landfilling and if not possible to add lime.
Food Chemistry | 2017
Beatriz Gómez-Nieto; Mª Jesús Gismera; Mª Teresa Sevilla; Jesús R. Procopio
A simple method based on FAAS was developed for the sequential multi-element determination of Cu, Zn, Mn, Mg and Si in beverages and food supplements with successful results. The main absorption lines for Cu, Zn and Si and secondary lines for Mn and Mg were selected to carry out the measurements. The sample introduction was performed using a flow injection system. Using the choice of the absorption line wings, the upper limit of the linear range increased up to 110mgL-1 for Mg, 200mgL-1 for Si and 13mgL-1 for Zn. The determination of the five elements was carried out, in triplicate, without the need of additional sample dilutions and/or re-measurements, using less than 3.5mL of sample to perform the complete analysis. The LODs were 0.008mgL-1 for Cu, 0.017mgL-1 for Zn, 0.011mgL-1 for Mn, 0.16mgL-1 for Si and 0.11mgL-1 for Mg.
Talanta | 2017
Beatriz Gómez-Nieto; Mª Jesús Gismera; Mª Teresa Sevilla; Jorgina Satrústegui; Jesús R. Procopio
A micro-sampling and straightforward method based on high resolution continuum source atomic absorption spectrometry (HR-CS AAS) was developed to determine extracellular and intracellular Ca in samples of interest in clinical and biomedical analysis. Solid sampling platforms were used to introduce the micro-samples into the graphite furnace atomizer. The secondary absorption line for Ca, located at 239.856nm, was selected to carry out the measurements. Experimental parameters such as pyrolysis and atomization temperatures and the amount of sample introduced for the measurements were optimized. Calibration was performed using aqueous standards and the approach to measure at the wings of the absorption lines was employed for the expansion of the linear response range. The limit of detection was of 0.02mgL-1 Ca (0.39ng Ca) and the upper limit of linear range was increased up to 8.0mgL-1 Ca (160ng Ca). The proposed method was used to determine Ca in mitochondrial suspensions and whole blood samples with successful results. Adequate recoveries (within 91-107%) were obtained in the tests performed for validation purposes.
Electroanalysis | 2003
Mª Jesús Gismera; Jesús R. Procopio; Mª Teresa Sevilla; Lucas Hernández