Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Marc-Aurele Brun is active.

Publication


Featured researches published by Marc-Aurele Brun.


Applied Physics Letters | 2009

Aspheric silicon lenses for terahertz photoconductive antennas

Florian Formanek; Marc-Aurele Brun; Tomoyuki Umetsu; Shinji Omori; Akio Yasuda

We report on the design and characterization of aspheric focusing silicon lenses for terahertz photoconductive antennas. The lenses are engineered using ray-tracing software and characterized using an optical fiber terahertz time-domain spectroscopy system. We find that using aspheric lenses improves terahertz radiation coupling from the emitter and enables improved collection by the detector. The signal-to-noise ratio and the cutoff frequency of measured terahertz spectra are improved. Minimized aberrations also reduce the focal spot size. Simulations based on Fresnel–Kirchhoff diffraction theory, taking into account the radiation pattern of the emitter and aberrations of the lenses, show good agreement with our measurements.


Analytical Chemistry | 2015

Principles of Dielectric Blood Coagulometry as a Comprehensive Coagulation Test

Yoshihito Hayashi; Marc-Aurele Brun; Kenzo Machida; Masayuki Nagasawa

Dielectric blood coagulometry (DBCM) is intended to support hemostasis management by providing comprehensive information on blood coagulation from automated, time-dependent measurements of whole blood dielectric spectra. We discuss the relationship between the series of blood coagulation reactions, especially the aggregation and deformation of erythrocytes, and the dielectric response with the help of clot structure electron microscope observations. Dielectric response to the spontaneous coagulation after recalcification presented three distinct phases that correspond to (P1) rouleau formation before the onset of clotting, (P2) erythrocyte aggregation and reconstitution of aggregates accompanying early fibrin formation, and (P3) erythrocyte shape transformation and/or structure changes within aggregates after the stable fibrin network is formed and platelet contraction occurs. Disappearance of the second phase was observed upon addition of tissue factor and ellagic acid for activation of extrinsic and intrinsic pathways, respectively, which is attributable to accelerated thrombin generation. A series of control experiments revealed that the amplitude and/or quickness of dielectric response reflect platelet function, fibrin polymerization, fibrinolysis activity, and heparin activity. Therefore, DBCM sensitively measures blood coagulation via erythrocytes aggregation and shape changes and their impact on the dielectric permittivity, making possible the development of the battery of assays needed for comprehensive coagulation testing.


Biomedical Optics Express | 2011

Contrast improvement of terahertz images of thin histopathologic sections

Florian Formanek; Marc-Aurele Brun; Akio Yasuda

We present terahertz images of 10 μm thick histopathologic sections obtained in reflection geometry with a time-domain spectrometer, and demonstrate improved contrast for sections measured in paraffin with water. Automated segmentation is applied to the complex refractive index data to generate clustered terahertz images distinguishing cancer from healthy tissues. The degree of classification of pixels is then evaluated using registered visible microscope images. Principal component analysis and propagation simulations are employed to investigate the origin and the gain of image contrast.


Biorheology | 2017

Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry

Yoshihito Hayashi; Marc-Aurele Brun; Kenzo Machida; Seungmin Lee; Aya Murata; Shinji Omori; Hidetoshi Uchiyama; Yoshinori Inoue; Toshifumi Kudo; Takahiro Toyofuku; Masayuki Nagasawa; Isao Uchimura; Tomomasa Nakamura

Background: In a whole blood coagulation test, the concentration of any in vitro diagnostic agent in plasma is dependent on the hematocrit level but its impact on the test result is unknown. Objective: The aim of this work was to clarify the effects of reagent concentration, particularly Ca2+, and to find a method for hematocrit estimation compatible with the coagulation test. Methods: Whole blood coagulation tests by dielectric blood coagulometry (DBCM) and rotational thromboelastometry were performed with various concentrations of Ca2+ or on samples with different hematocrit levels. DBCM data from a previous clinical study of patients who underwent total knee arthroplasty were re-analyzed. Results: Clear Ca2+ concentration and hematocrit level dependences of the characteristic times of blood coagulation were observed. Rouleau formation made hematocrit estimation difficult in DBCM, but use of permittivity at around 3 MHz made it possible. The re-analyzed clinical data showed a good correlation between permittivity at 3 MHz and hematocrit level (R2=0.83). Conclusions: Changes in the hematocrit level may affect whole blood coagulation tests. DBCM has the potential to overcome this effect with some automated correction using results from simultaneous evaluations of the hematocrit level and blood coagulability.


Archive | 2009

Biosample analysis method, biosample analyzer, and biosample analysis program

Marc-Aurele Brun; Yoshinobu Eishi; Florian Formanek; Shinji Omori; Tasuku Setoriyama; Tomoyuki Umezu; マルクオレル ブルン; フォルマネク フロリアン; 翼 世取山; 真二 大森; 友行 梅津; 義信 江石


Physical Review B | 2007

Urea-glycerol system : Liquid associated structure studied by dielectric spectroscopy

Marc-Aurele Brun; Yoshihito Hayashi; Yoichi Katsumoto; Shinji Omori; Akio Yasuda


Archive | 2008

Terahertz spectroscopic apparatus

Marc-Aurele Brun; Florian Formanek; マルクオレル ブルン; フォルマネク フロリアン


Archive | 2017

血液状態解析装置、血液状態解析システム、血液状態解析方法、および該方法をコンピューターに実現させるための血液状態解析プログラム

Yoshihito Hayashi; 義人 林; Marc-Aurele Brun; マルクオレル ブルン; Yoichi Katsumoto; 洋一 勝本


Archive | 2016

Electric measurement method, electric measurement device, and system for analyzing condition of blood

スンミン イ; Seungmin Lee; 賢三 町田; Kenzo Machida; 香織 川口; Kaori Kawaguchi; マルクオレル ブルン; Marc-Aurele Brun


Archive | 2015

血液状態解析装置、血液状態解析システム、血液状態解析方法及びプログラム

マルクオレル ブルン; Marc-Aurele Brun; 賢三 町田; Kenzo Machida; 義人 林; Yoshihito Hayashi; 友行 梅津; Tomoyuki Umetsu

Collaboration


Dive into the Marc-Aurele Brun's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Shinji Omori

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Yoichi Katsumoto

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Florian Formanek

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Tomoyuki Umetsu

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hidetoshi Uchiyama

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Isao Uchimura

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Takahiro Toyofuku

Tokyo Medical and Dental University

View shared research outputs
Top Co-Authors

Avatar

Tomomasa Nakamura

Tokyo Medical and Dental University

View shared research outputs
Researchain Logo
Decentralizing Knowledge