Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Marcela C. Rodrigues is active.

Publication


Featured researches published by Marcela C. Rodrigues.


International Endodontic Journal | 2015

Ion release and mechanical properties of calcium silicate and calcium hydroxide materials used for pulp capping.

Livia C. Natale; Marcela C. Rodrigues; T. A. Xavier; Alyne Simões; D.N. de Souza; Roberto R. Braga

AIM To compare the ion release and mechanical properties of a calcium hydroxide (Dycal) and two calcium silicate (MTA Angelus and Biodentine) cements. METHODOLOGY Calcium and hydroxyl ion release in water from 24-h set cements were calculated from titration with HCl (n = 3). Calcium release after 7, 14, 21 and 28 days at pH 5.5 and 7.0 was measured using ICP-OES (n = 6). Flexural strength (FS) and modulus (E) were tested after 48-h storage, and compressive strength (CS) was tested after 48 h and 7 days (n = 10). Ion release and mechanical data were subjected to anova/Tukey and Kruskal-Wallis/Mann-Whitney tests, respectively (α = 0.05). RESULTS Titration curves revealed that Dycal released significantly fewer ions in solution than calcium silicates (P < 0.001). Calcium release remained constant at pH 7.0, whilst at pH 5.5, it dropped significantly by 24% after 21 days (P < 0.05). At pH 5.5, MTA Angelus released significantly more calcium than Dycal (P < 0.01), whilst Biodentine had superior ion release than Dycal at pH 7.0 (P < 0.01). Biodentine had superior flexural strength, flexural modulus and compressive strength than the other cements, whilst MTA Angelus had higher modulus than Dycal (P < 0.001). CONCLUSIONS Immediate calcium and hydroxyl ion release in solution was significantly lower for Dycal. In general, all materials released constant calcium levels over 28 days, but release from Dycal was significantly lower than Biodentine and MTA Angelus depending on pH conditions. Biodentine had substantially higher strength and modulus than MTA Angelus and Dycal, both of which demonstrated low stress-bearing capabilities.


Journal of Applied Oral Science | 2012

Impact of filler size and distribution on roughness and wear of composite resin after simulated toothbrushing

Gabriela Ulian de Oliveira; Rafael Francisco Lia Mondelli; Marcela C. Rodrigues; Eduardo Batista Franco; Sérgio Kiyoshi Ishikiriama; Linda Wang

Objectives Nanofilled composite resins are claimed to provide superior mechanical properties compared with microhybrid resins. Thus, the aim of this study was to compare nanofilled with microhybrid composite resins. The null hypothesis was that the size and the distribution of fillers do not influence the mechanical properties of surface roughness and wear after simulated toothbrushing test. Material and methods Ten rectangular specimens (15 mm x 5 mm x 4 mm) of Filtek Z250 (FZ2), Admira (A), TPH3 (T),Esthet-X (EX), Estelite Sigma (ES), Concept Advanced (C), Grandio (G) and Filtek Z350 (F) were prepared according to manufacturers instructions. Half of each top surface was protected with nail polish as control surface (not brushed) while the other half was assessed with five random readings using a roughness tester (Ra). Following, the specimens were abraded by simulated toothbrushing with soft toothbrushes and slurry comprised of 2:1 water and dentifrice (w/w). 100,000 strokes were performed and the brushed surfaces were re-analyzed. Nail polish layers were removed from the specimens so that the roughness (Ra) and the wear could be assessed with three random readings (µm). Data were analyzed by ANOVA and Tukeys multiple-comparison test (α=0.05). Results Overall outcomes indicated that composite resins showed a significant increase in roughness after simulated toothbrushing, except for Grandio, which presented a smoother surface. Generally, wear of nanofilled resins was significantly lower compared with microhybrid resins. Conclusions As restorative materials suffer alterations under mechanical challenges, such as toothbrushing, the use of nanofilled materials seem to be more resistant than microhybrid composite resins, being less prone to be rougher and worn.


Journal of Applied Oral Science | 2013

Minimal alterations on the enamel surface by micro-abrasion: in vitro roughness and wear assessments

Marcela C. Rodrigues; Rafael Francisco Lia Mondelli; Gabriela Ulian de Oliveira; Eduardo Batista Franco; Wagner Baseggio; Linda Wang

Objective: To evaluate the in vitro changes on the enamel surface after a micro-abrasion treatment promoted by different products. Material and Methods: Fifty (50) fragments of bovine enamel (15 mm x 5 mm) were randomly assigned to five groups (n=10) according to the product utilized: G1 (control)= silicone polisher (TDV), G2= 37% phosphoric acid (3M/ESPE) + pumice stone (SS White), G3= Micropol (DMC Equipment), G4= Opalustre (Ultradent) and G5= Whiteness RM (FGM Dental Products). Roughness and wear were the responsible variables used to analyze these surfaces in four stages: baseline, 60 s and 120 s after the micro-abrasion and after polishing, using a Hommel Tester T1000 device. After the tests, a normal distribution of data was verified, with repeated ANOVA analyses (p≤0.05) which were used to compare each product in different stages. One-way ANOVA and Tukey tests were applied for individual comparisons between the products in each stage (p≤0.05). Results: Means and standard deviations of roughness and wear (mm) after all the promoted stages were: G1=7.26(1.81)/13.16(2.67), G2=2.02(0.62)/37.44(3.33), G3=1.81(0.91)/34.93(6.92), G4=1.92(0.29)/38.42(0.65) and G5=1.98(0.53)/33.45(2.66). At 60 seconds, all products tended to produce less surface roughness with a variable gradual decrease over time. After polishing, there were no statistically significant differences between the groups, except for G1. Independent of the product utilized, the enamel wear occurred after the micro-abrasion. Conclusions: In this in vitro study, enamel micro-abrasion presented itself as a conservative approach, regardless of the type of the paste compound utilized. These products promoted minor roughness alterations and minimal wear. The use of phosphoric acid and pumice stone showed similar results to commercial products for the micro-abrasion with regard to the surface roughness and wear.


Dental Materials | 2016

Bioactive composites containing TEGDMA-functionalized calcium phosphate particles: Degree of conversion, fracture strength and ion release evaluation.

Yvette Alania; Marina D.S. Chiari; Marcela C. Rodrigues; Victor E. Arana-Chavez; Ana Helena A. Bressiani; Flavio M. Vichi; Roberto R. Braga

OBJECTIVE To evaluate the strength and ion release of experimental composites containing TEGDMA-functionalized calcium phosphate particles. METHODS Seven composites containing equal parts (in mols) of BisGMA and TEGDMA and 60vol% of fillers were manipulated. Filler phase was constituted by silanized barium glass and 0% (control), 10% or 20% (volume) of dicalcium phosphate dihydrate (DPCD) particles, either non-functionalized or functionalized with two different TEDGMA contents. DCPD particles were synthesized and characterized by X-ray diffraction (XRD), elemental analysis, surface area and dynamic light scattering. Composites were tested for degree of conversion (DC) by near-FTIR. Biaxial flexural strength (BFS) was determined after 24h and 28days in water. Calcium and phosphate release after 7days was assessed using inductively coupled plasma optical emission spectrometry (ICP-OES). Data were analyzed by ANOVA/Tukey test (alpha:5%). RESULTS XRD confirmed the crystalline structure corresponding to DCPD. Elemental analysis revealed particles with zero, 14% or 22% TEGDMA, with similar D50 (around 19μm) and surface areas from 3.5 to 11.4m2/g. The presence of DCPD did not reduce DC. After 24h, functionalization (both 14% and 22% TEGDMA) improved composite strength in comparison to non-functionalized DCPD, both at 10% and 20% levels. After 28days, BFS of materials containing 10% functionalized DCPD were statistically similar to the control containing only barium glass. Among composites containing 10% DCPD, particle functionalization with 14% TEGDMA did not jeopardize ion release. SIGNIFICANCE At 10vol%, the use of TEGDMA-functionalized CaP particles improved composite strength in relation to non-functionalized particles, while maintaining similar ion release levels.


Journal of Biomaterials Applications | 2017

Polymer-based material containing calcium phosphate particles functionalized with a dimethacrylate monomer for use in restorative dentistry

Marcela C. Rodrigues; Tathy Aparecida Xavier; Victor E. Arana-Chavez; Roberto R. Braga

Dicalcium phosphate dihydrate particles functionalized with triethyleneglycol dimethacrylate were synthesized and added to a photocurable mixture of bisphenol-A glycidyl dimethacrylate and triethyleneglycol dimethacrylate with the purpose of developing a resin composite capable of releasing calcium and phosphate ions to foster dental remineralization. Particle functionalization would minimize the deleterious effect of adding low cohesive strength nano-structured particles with no chemical interaction with the organic matrix on the material’s mechanical properties. The results showed that calcium release over 28 days was not impaired by particle functionalization. A statistically significant 32% increase in strength was recorded with the use of functionalized dicalcium phosphate dihydrate in comparison to the material containing non-functionalized particles. However, the strength of the unfilled resin was not matched by the composite with functionalized particles. Elastic modulus increased with particle incorporation, regardless of functionalization. Degree of conversion and optical properties (total transmittance and color change/ΔE) of the resin-based materials were not affected by the addition of dicalcium phosphate dihydrate particles (functionalized or not).


Journal of Materials Science: Materials in Medicine | 2017

Streptococcus mutans adherence and biofilm formation on experimental composites containing dicalcium phosphate dihydrate nanoparticles

Andrei C. Ionescu; Sebastian Hahnel; Gloria Cazzaniga; Marco Ottobelli; Roberto R. Braga; Marcela C. Rodrigues; Eugenio Brambilla

This study aimed at evaluating bacterial adhesion and biofilm formation on resin-based composites (RBC) including dicalcium phosphate dihydrate nanoparticles (nDCPD). Methods: Specimens were prepared from experimental RBCs with BisGMA/TEGDMA resin matrix including 20 vol% of either nDCPD (nDCPD-RBC), TEGDMA-functionalized nDPCD (F-nDCPD-RBC) or silanized silica (SiO2-RBC). Neat resin blend (control-Resin), conventional nanohybrid RBC (control-RBC) and human enamel were used for reference. Characterization of the specimens included surface roughness (SR), surface free energy (SFE), chemical surface composition (EDS, XPS), and buffering ability of a pH = 4.00 solution. Streptococcus mutans adherence was assessed after 2 h; biofilm formation was simulated for 48 h using a bioreactor. Adherent, viable biomass was determined using tetrazolium salt assay (MTT). Results: nDCPD-RBC yielded highest roughness and showed higher polar and lower disperse component to total SFE. EDS and XPS indicated higher amounts of calcium and phosphate on the surface of nDCPD-RBC than on F-nDCPD-RBC. nDCPD buffered the acidic solution to 5.74, while functionalization almost prevented buffering (pH = 4.26). F-nDCPD-RBC reduced adherence and biofilm formation in comparison to nDCPD-RBC. Regardless of functionalization, biofilm formation on nDCPD-containing RBCs was not significantly different from SiO2-RBC. Control-Resin, control-RBC, and enamel surfaces showed similar adherence values as F-nDCPD-RBC, but lower biofilm formation compared to both nDCPD-containing RBCs. In conclusion, the incorporation of nDCPD did not minimize S. mutans adherence and biofilm formation as a function of the materials´ surface properties. However, results observed for the buffering capacity indicated that optimized formulations of biomimetic RBCs may be useful for modulating their interaction with microorganisms.Graphical Abstract


Journal of Biomedical Materials Research Part B | 2015

Calcium and phosphate release from resin-based materials containing different calcium orthophosphate nanoparticles.

Marcela C. Rodrigues; Livia C. Natale; Victor E. Arana‐Chaves; Roberto R. Braga

The study compared ion release from resin-based materials containing calcium orthophosphates. Amorphous calcium phosphate (ACP), dicalcium phosphate anhydrous (DCPA), dicalcium phosphate dihydrate (DCPD), and tricalcium phosphate (β-TCP) nanoparticles were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), dynamic light scattering (DLS), and surface area (nitrogen adsorption isotherms, BET method). Nanoparticles were added to a dimethacrylate-based resin and materials were tested for degree of conversion (DC) and calcium/phosphate release up to 28 days under pH 5.5 and 7.0. Data were analyzed by ANOVA/Tukey test (alpha: 0.05).The crystallinity of DCPA, DCPD, and β-TCP were confirmed, as well as the ACP amorphous nature. DCPD and β-TCP presented larger agglomerates than DCPA and ACP. The surface area of ACP was 5-11 times higher than those of the other nanoparticles. Materials showed similar DC. The material containing ACP released significantly more ions than the others, which released similar amounts of calcium and, in most cases, phosphate. Ion release was not affected by pH. Calcium release decreased between 7 and 21 days, while phosphate levels remained constant after 14 days. In conclusion, ACP higher ion release can be ascribed to its high surface area. DCPA, DCPD, and β-TCP had similar performances as ion-releasing fillers.


Materials Science and Engineering: C | 2017

Synthesis and characterization of silver phosphate/calcium phosphate mixed particles capable of silver nanoparticle formation by photoreduction

Livia C. Natale; Yvette Alania; Marcela C. Rodrigues; Alyne Simões; Douglas Nesadal de Souza; Erick de Lima; Victor E. Arana-Chavez; Thiago L.R. Hewer; Rochelle Denise Hiers; Fernando L. Esteban-Florez; G.E.S. Brito; Sharukh S. Khajotia; Roberto R. Braga

Silver phosphate is a semi-conductor sensitive to UV-Vis radiation (<530nm). Exposure to radiation removes electrons from the oxygen valence shell, which are scavenged by silver cations (Ag+), forming metallic silver (Ag0) nanoparticles. The possibility of silver nanoparticle formation in situ by a photoreduction process was the basis for the application of mixed calcium phosphate/silver phosphate particles as remineralizing and antibacterial fillers in resin-based dental materials. Mixed phosphate particles were synthesized, characterized and added to a dimethacrylate resin in 20% or 30% mass fractions to investigate their efficacy as ion-releasing fillers for dental remineralization and antibacterial activity. The formation of metallic silver nanoparticles after exposure to visible radiation from a dental curing unit (peak emission: 470nm) was demonstrated by particle X-ray diffraction and scanning electron microscopy analysis of the composite fractured surface. Calcium and phosphate release from materials containing the mixed particles were similar to those containing pure CaP particles, whereas Streptococcus mutans colonies were reduced by three orders of magnitude in relation to the control, which can be attributed to silver release. As expected, the optical properties of the materials containing mixed phosphate particles were compromised by the presence of silver. Nevertheless, materials containing mixed phosphate particles presented higher fracture strength and elastic modulus than those with pure CaP particles.


Journal of The Mechanical Behavior of Biomedical Materials | 2018

Mechanical characterization and ion release of bioactive dental composites containing calcium phosphate particles

Livia C. Natale; Marcela C. Rodrigues; Yvette Alania; Marina D.S. Chiari; L.C.C. Boaro; Marycel Cotrim; Oscar Vega; Roberto R. Braga

OBJECTIVE to verify the effect of the addition of dicalcium phosphate dihydrate (DCPD) particles functionalized with di- or triethylene glycol dimethacrylate (DEGDMA or TEGDMA) on the degree of conversion (DC), post-gel shrinkage (PS), mechanical properties, and ion release of experimental composites. METHODS Four composites were prepared containing a BisGMA/TEGDMA matrix and 60 vol% of fillers. The positive control contained only barium glass fillers, while in the other composites 15 vol% of the barium was replaced by DCPD. Besides the functionalized particles, non-functionalized DCPD was also tested. DC after 24 h (n = 3) was determined by FTIR spectroscopy. The strain gage method was used to obtain PS 5 min after photoactivation (n = 5). Flexural strength and modulus (n = 10) were calculated based on the biaxial flexural test results, after specimen storage for 24 h or 60 days in water. The same storage times were used for fracture toughness testing (FT, n = 10). Calcium and phosphate release up to 60 days was quantified by ICP-OES (n = 3). Data were analyzed by ANOVA/Tukey test (alpha: 5%). RESULTS Composites containing functionalized DCPD presented higher DC than the control (p < 0.001). The material containing DEGDMA-functionalized particles showed higher PS than the other composites (p < 0.001). After 60 days, only the composite with DEGDMA-functionalized DCPD presented fracture strength similar to the control, while for flexural modulus only the composite with TEGDMA-functionalized particles was lower than the control (p < 0.001). FT of all composites containing DCPD was higher than the control after 60 days (p < 0.005). Calcium release was higher for the composite with non-functionalized DCPD at 15 days and no significant reductions were observed for composites with functionalized DCPD during the observation period (p < 0.001). For all the tested composites, phosphate release was higher at 15 days than in the subsequent periods, and no difference among them was recorded at 45 and 60 days (p < 0.001). CONCLUSIONS DCPD functionalization affected all the studied variables. The composite with DEGDMA-functionalized particles was the only material with strength similar to the control after 60 days in water; however, it also presented the highest shrinkage. The presence of DCPD improved FT, regardless of functionalization. DCPD functionalization reduced ion release only during the first 15 days.


Dental Materials | 2018

Ion-releasing dental restorative composites containing functionalized brushite nanoparticles for improved mechanical strength

Marcela C. Rodrigues; Marina D.S. Chiari; Yvette Alania; Livia C. Natale; Victor E. Arana-Chavez; Marcia Margarete Meier; Victória S. Fadel; Flavio M. Vichi; Thiago L.R. Hewer; Roberto R. Braga

OBJECTIVES This study describes the synthesis of brushite nanoparticles (CaHPO4·2H2O) functionalized with triethylene glycol dimethacrylate (TEGDMA) and their application in dental restorative composites with remineralizing capabilities. METHODS Nanoparticles were synthesized, with TEGDMA being added to one of the precursor solutions at three different molar ratios (0:1, 0.5:1 and 1:1, in relation to the ammonium phosphate precursor). Then, they were added (10 vol%) to a photocurable dimethacrylate matrix containing 50 vol% of reinforcing glass particles. The resulting composites were tested for degree of conversion, biaxial flexural strength and elastic modulus (after 24h and 28days in water), and ion release (over a 28-day period). Commercial composites (one microhybrid and one microfilled) were tested as controls. RESULTS The final TEGDMA content in the functionalizing layer was modulated by the molar ratio added to the precursor solution. Functionalization reduced nanoparticle size, but did not reduce agglomeration. Improved mechanical properties were found for the composite containing nanoparticles with higher TEGDMA level in comparison to the composite containing non-functionalized nanoparticles or those with a low TEGDMA level. All brushite composites presented statistically significant reductions in strength after 28 days in water, but only the material with high-TEGDMA nanoparticles retained strength similar to the microhybrid commercial control. Overall, ion release was not affected by functionalization and presented steady levels for 28 days. SIGNIFICANCE Though agglomeration was not reduced by functionalization, the improvement in the matrix-nanoparticle interface allowed for a stronger material, without compromising its remineralizing potential.

Collaboration


Dive into the Marcela C. Rodrigues's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yvette Alania

University of São Paulo

View shared research outputs
Top Co-Authors

Avatar

Alyne Simões

University of São Paulo

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

G.E.S. Brito

University of São Paulo

View shared research outputs
Researchain Logo
Decentralizing Knowledge