Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Marcin Szkudlarek is active.

Publication


Featured researches published by Marcin Szkudlarek.


Arthritis & Rheumatism | 2001

Power doppler ultrasonography for assessment of synovitis in the metacarpophalangeal joints of patients with rheumatoid arthritis: A comparison with dynamic magnetic resonance imaging

Marcin Szkudlarek; Michel Court-Payen; Charlotte Strandberg; Mette Klarlund; Tom Klausen; Mikkel Østergaard

OBJECTIVE To evaluate the effectiveness of power Doppler ultrasonography (PDUS) for assessing inflammatory activity in the metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA), using dynamic magnetic resonance imaging (MRI) as a reference method. METHODS PDUS and dynamic MRI were performed on 54 MCP joints of 15 patients with active RA and on 12 MCP joints of 3 healthy controls. PDUS was performed with a LOGIQ 500 unit by means of a 7-13-MHz linear array transducer. Later the same day, MRI was performed with a 1.0T MR unit. A series of 24 coronal T1-weighted images of the second through the fifth MCP joints was obtained, with intravenous injection of gadolinium diethylenetriaminepentaacetic acid after the fourth image (dynamic MRI). From the MR images, the rate of early synovial enhancement (RESE; defined as the relative enhancement per second during the first 55 seconds postinjection) was calculated and compared with the flow signal on PDUS, which was scored as present or absent. RESULTS In RA patients, flow signal on PDUS was detected in 17 of 54 MCP joints examined. Postcontrast MR images revealed an RESE of > or = 1.0%/second in 18 of 54 RA MCP joints. PDUS showed no flow in 47 of 48 MCP joints with an RESE of <1.0%/second and revealed flow in 16 of 18 MCP joints with an RESE of > or = 1.0%/second. Using dynamic MRI as a reference, PDUS had a sensitivity of 88.8% and a specificity of 97.9%. CONCLUSION PDUS was reliable for assessing inflammatory activity in the MCP joints of RA patients, using dynamic MRI as the standard. PDUS and clinical assessment of joint swelling/tenderness were only weakly correlated.


Arthritis Research & Therapy | 2006

Ultrasonography of the metacarpophalangeal and proximal interphalangeal joints in rheumatoid arthritis: a comparison with magnetic resonance imaging, conventional radiography and clinical examination.

Marcin Szkudlarek; Mette Klarlund; Eva Narvestad; Michel Court-Payen; Charlotte Strandberg; Karl Erik Jensen; Henrik S. Thomsen; Mikkel Østergaard

Signs of inflammation and destruction in the finger joints are the principal features of rheumatoid arthritis (RA). There are few studies assessing the sensitivity and specificity of ultrasonography in detecting these signs. The objective of the present study was to investigate whether ultrasonography can provide information on signs of inflammation and destruction in RA finger joints that are not available with conventional radiography and clinical examination, and comparable to the information provided by magnetic resonance imaging (MRI). The second to fifth metacarpophalangeal and proximal interphalangeal joints of 40 RA patients and 20 control persons were assessed with ultrasonography, clinical examination, radiography and MRI. With MRI as the reference method, the sensitivity, specificity and accuracy of ultrasonography in detecting bone erosions in the finger joints were 0.59, 0.98 and 0.96, respectively; they were 0.42, 0.99 and 0.95 for radiography. The sensitivity, specificity and accuracy of ultrasonography, with signs of inflammation on T1-weighted MRI sequences as the reference method, were 0.70, 0.78 and 0.76, respectively; they were 0.40, 0.85 and 0.72 for the clinical examination. With MRI as the reference method, ultrasonography had higher sensitivity and accuracy in detecting signs of inflammation and destruction in RA finger joints than did clinical and radiographic examinations, without loss of specificity. This study shows that ultrasonography has the potential to improve assessment of patients with RA.


Annals of the Rheumatic Diseases | 2005

Interobserver reliability of rheumatologists performing musculoskeletal ultrasonography: results from a EULAR “Train the trainers” course

Alexander K. Scheel; Wolfgang A. Schmidt; Kay-Geert A. Hermann; George A. W. Bruyn; Maria Antonietta D'Agostino; Walter Grassi; Annamaria Iagnocco; Juhani M. Koski; Klaus Machold; Esperanza Naredo; Horst Sattler; Nanno Swen; Marcin Szkudlarek; Richard J. Wakefield; Hans Rudolf Ziswiler; Daniel Pasewaldt; Carola Werner; M. Backhaus

Objective: To evaluate the interobserver reliability among 14 experts in musculoskeletal ultrasonography (US) and to determine the overall agreement about the US results compared with magnetic resonance imaging (MRI), which served as the imaging “gold standard”. Methods: The clinically dominant joint regions (shoulder, knee, ankle/toe, wrist/finger) of four patients with inflammatory rheumatic diseases were ultrasonographically examined by 14 experts. US results were compared with MRI. Overall agreements, sensitivities, specificities, and interobserver reliabilities were assessed. Results: Taking an agreement in US examination of 10 out of 14 experts into account, the overall κ for all examined joints was 0.76. Calculations for each joint region showed high κ values for the knee (1), moderate values for the shoulder (0.76) and hand/finger (0.59), and low agreement for ankle/toe joints (0.28). κ Values for bone lesions, bursitis, and tendon tears were high (κ = 1). Relatively good agreement for most US findings, compared with MRI, was found for the shoulder (overall agreement 81%, sensitivity 76%, specificity 89%) and knee joint (overall agreement 88%, sensitivity 91%, specificity 88%). Sensitivities were lower for wrist/finger (overall agreement 73%, sensitivity 66%, specificity 88%) and ankle/toe joints (overall agreement 82%, sensitivity 61%, specificity 92%). Conclusion: Interobserver reliabilities, sensitivities, and specificities in comparison with MRI were moderate to good. Further standardisation of US scanning techniques and definitions of different pathological US lesions are necessary to increase the interobserver agreement in musculoskeletal US.


Annals of the Rheumatic Diseases | 2006

Interobserver reliability in musculoskeletal ultrasonography: results from a “Teach the Teachers” rheumatologist course

Esperanza Naredo; Ingrid Möller; C. Moragues; J. de Agustin; Alexander K. Scheel; Walter Grassi; E. de Miguel; M. Backhaus; Peter V. Balint; George A. W. Bruyn; M-A D'Agostino; Emilio Filippucci; Annamaria Iagnocco; David Kane; Juhani M. Koski; Mayordomo L; Wolfgang A. Schmidt; Wijnand A. A. Swen; Marcin Szkudlarek; L Terslev; Søren Torp-Pedersen; Jacqueline Uson; Richard J. Wakefield; Carola Werner

Objective: To assess the interobserver reliability of the main periarticular and intra-articular ultrasonographic pathologies and to establish the principal disagreements on scanning technique and diagnostic criteria between a group of experts in musculoskeletal ultrasonography. Methods: The shoulder, wrist/hand, ankle/foot, or knee of 24 patients with rheumatic diseases were evaluated by 23 musculoskeletal ultrasound experts from different European countries randomly assigned to six groups. The participants did not reach consensus on scanning method or diagnostic criteria before the investigation. They were unaware of the patients’ clinical and imaging data. The experts from each group undertook a blinded ultrasound examination of the four anatomical regions. The ultrasound investigation included the presence/absence of joint effusion/synovitis, bony cortex abnormalities, tenosynovitis, tendon lesions, bursitis, and power Doppler signal. Afterwards they compared the ultrasound findings and re-examined the patients together while discussing their results. Results: Overall agreements were 91% for joint effusion/synovitis and tendon lesions, 87% for cortical abnormalities, 84% for tenosynovitis, 83.5% for bursitis, and 83% for power Doppler signal; κ values were good for the wrist/hand and knee (0.61 and 0.60) and fair for the shoulder and ankle/foot (0.50 and 0.54). The principal differences in scanning method and diagnostic criteria between experts were related to dynamic examination, definition of tendon lesions, and pathological v physiological fluid within joints, tendon sheaths, and bursae. Conclusions: Musculoskeletal ultrasound has a moderate to good interobserver reliability. Further consensus on standardisation of scanning technique and diagnostic criteria is necessary to improve musculoskeletal ultrasonography reproducibility.


Arthritis Research & Therapy | 2006

Are bone erosions detected by magnetic resonance imaging and ultrasonography true erosions? A comparison with computed tomography in rheumatoid arthritis metacarpophalangeal joints

Uffe Møller Døhn; Bo Ejbjerg; Michel Court-Payen; Maria Hasselquist; Eva Narvestad; Marcin Szkudlarek; Jakob M. Møller; Henrik S. Thomsen; Mikkel Østergaard

The objective of the study was, with multidetector computed tomography (CT) as the reference method, to determine whether bone erosions in rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints detected with magnetic resonance imaging (MRI) and ultrasonography (US), but not with radiography, represent true erosive changes. We included 17 RA patients with at least one, previously detected, radiographically invisible MCP joint MRI erosion, and four healthy control individuals. They all underwent CT, MRI, US and radiography of the 2nd to 5th MCP joints of one hand on the same day. Each imaging modality was evaluated for the presence of bone erosions in each MCP joint quadrant. In total, 336 quadrants were examined. The sensitivity, specificity and accuracy, respectively, for detecting bone erosions (with CT as the reference method) were 19%, 100% and 81% for radiography; 68%, 96% and 89% for MRI; and 42%, 91% and 80% for US. When the 16 quadrants with radiographic erosions were excluded from the analysis, similar values for MRI (65%, 96% and 90%) and US (30%, 92% and 80%) were obtained. CT and MRI detected at least one erosion in all patients but none in control individuals. US detected at least one erosion in 15 patients, however, erosion-like changes were seen on US in all control individuals. Nine patients had no erosions on radiography. In conclusion, with CT as the reference method, MRI and US exhibited high specificities (96% and 91%, respectively) in detecting bone erosions in RA MCP joints, even in the radiographically non-erosive joints (96% and 92%). The moderate sensitivities indicate that even more erosions than are seen on MRI and, particularly, US are present. Radiography exhibited high specificity (100%) but low sensitivity (19%). The present study strongly indicates that bone erosions, detected with MRI and US in RA patients, represent a loss of calcified tissue with cortical destruction, and therefore can be considered true bone erosions.


Arthritis Research & Therapy | 2007

Ultrasonography, magnetic resonance imaging, radiography, and clinical assessment of inflammatory and destructive changes in fingers and toes of patients with psoriatic arthritis

Charlotte Wiell; Marcin Szkudlarek; Maria Hasselquist; Jakob M. Møller; Aage Vestergaard; Jesper Nørregaard; Lene Terslev; Mikkel Østergaard

The aim of the present study was to assess ultrasonography (US) for the detection of inflammatory and destructive changes in finger and toe joints, tendons, and entheses in patients with psoriasis-associated arthritis (PsA) by comparison with magnetic resonance imaging (MRI), projection radiography (x-ray), and clinical findings. Fifteen patients with PsA, 5 with rheumatoid arthritis (RA), and 5 healthy control persons were examined by means of US, contrast-enhanced MRI, x-ray, and clinical assessment. Each joint of the 2nd–5th finger (metacarpophalangeal joints, proximal interphalangeal [PIP] joints, and distal interphalangeal [DIP] joints) and 1st–5th metatarsophalangeal joints of both hands and feet were assessed with US for the presence of synovitis, bone erosions, bone proliferations, and capsular/extracapsular power Doppler signal (only in the PIP joints). The 2nd–5th flexor and extensor tendons of the fingers were assessed for the presence of insertional changes and tenosynovitis. One hand was assessed by means of MRI for the aforementioned changes. X-rays of both hands and feet were assessed for bone erosions and proliferations. US was repeated in 8 persons by another ultrasonographer. US and MRI were more sensitive to inflammatory and destructive changes than x-ray and clinical examination, and US showed a good interobserver agreement for bone changes (median 96% absolute agreement) and lower interobserver agreement for inflammatory changes (median 92% absolute agreement). A high absolute agreement (85% to 100%) for all destructive changes and a more moderate absolute agreement (73% to 100%) for the inflammatory pathologies were found between US and MRI. US detected a higher frequency of DIP joint changes in the PsA patients compared with RA patients. In particular, bone changes were found exclusively in PsA DIP joints. Furthermore, bone proliferations were more common and tenosynovitis was less frequent in PsA than RA. For other pathologies, no disease-specific pattern was observed. US and MRI have major potential for improved examination of joints, tendons, and entheses in fingers and toes of patients with PsA.


Annals of the Rheumatic Diseases | 2010

Evaluation of several ultrasonography scoring systems for synovitis and comparison to clinical examination: results from a prospective multicentre study of rheumatoid arthritis

Maxime Dougados; Sandrine Jousse-Joulin; Frédéric Mistretta; Maria Antonietta D'Agostino; M. Backhaus; Jacques Bentin; Gérard Chalès; Isabelle Chary-Valckenaere; Philip G. Conaghan; F. Etchepare; Philippe Gaudin; Walter Grassi; Désirée van der Heijde; Jérémie Sellam; Esperanza Naredo; Marcin Szkudlarek; Richard J. Wakefield; Alain Saraux

Objectives To evaluate different global ultrasonographic (US) synovitis scoring systems as potential outcome measures of rheumatoid arthritis (RA) according to the Outcome Measures in Rheumatoid Arthritis Clinical Trials (OMERACT) filter. Methods To study selected global scoring systems, for the clinical, B mode and power Doppler techniques, the following joints were evaluated: 28 joints (28-joint Disease Activity Score (DAS28)), 20 joints (metacarpophalangeals (MCPs) + metatarsophalangeals (MTPs)) and 38 joints (28 joints + MTPs) using either a binary (yes/no) or a 0–3 grade. The study was a prospective, 4-month duration follow-up of 76 patients with RA requiring anti-tumour necrosis factor (TNF) therapy (complete follow-up data: 66 patients). Intraobserver reliability was evaluated using the intraclass correlation coefficient (ICC), construct validity was evaluated using the Cronbach α test and external validity was evaluated using level of correlation between scoring system and C reactive protein (CRP). Sensitivity to change was evaluated using the standardised response mean. Discriminating capacity was evaluated using the standardised mean differences in patients considered by the doctor as significantly improved or not at the end of the study. Results Different clinimetric properties of various US scoring systems were at least as good as the clinical scores with, for example, intraobserver reliability ranging from 0.61 to 0.97 versus from 0.53 to 0.82, construct validity ranging from 0.76 to 0.89 versus from 0.76 to 0.88, correlation with CRP ranging from 0.28 to 0.34 versus from 0.28 to 0.35 and sensitivity to change ranging from 0.60 to 1.21 versus from 0.96 to 1.36 for US versus clinical scoring systems, respectively. Conclusion This study suggests that US evaluation of synovitis is an outcome measure at least as relevant as physical examination. Further studies are required in order to achieve optimal US scoring systems for monitoring patients with RA in clinical trials and in clinical practice.


Annals of the Rheumatic Diseases | 2005

The EULAR-OMERACT rheumatoid arthritis MRI reference image atlas: the wrist joint

B Ejbjerg; Fiona M. McQueen; Marissa Lassere; Espen A. Haavardsholm; Philip G. Conaghan; P O'Connor; Paul Bird; Charles Peterfy; John Edmonds; Marcin Szkudlarek; H Genant; Paul Emery; M Ostergaard

This paper presents the wrist joint MR images of the EULAR–OMERACT rheumatoid arthritis MRI reference image atlas. Reference images for scoring synovitis, bone oedema, and bone erosions according to the OMERACT RA MRI scoring (RAMRIS) system are provided. All grades (0–3) of synovitis are illustrated in each of the three wrist joint areas defined in the scoring system—that is, the distal radioulnar joint, the radiocarpal joint, and the intercarpal-carpometacarpal joints. For reasons of feasibility, examples of bone abnormalities are limited to five selected bones: the radius, scaphoid, lunate, capitate, and a metacarpal base. In these bones, grades 0–3 of bone oedema are illustrated, and for bone erosion, grades 0–3 and examples of higher grades are presented. The presented reference images can be used to guide scoring of wrist joints according to the OMERACT RA MRI scoring system.


Annals of the Rheumatic Diseases | 2007

Rheumatoid arthritis bone erosion volumes on CT and MRI: reliability and correlations with erosion scores on CT, MRI and radiography

Uffe Møller Døhn; Bo Ejbjerg; Maria Hasselquist; Eva Narvestad; Michel Court-Payen; Marcin Szkudlarek; J. T. Moller; Henrik S. Thomsen; Mikkel Østergaard

Objectives: To investigate intramodality and intermodality agreements of CT and MRI erosion volumes in metacarpophalangeal (MCP) joints in rheumatoid arthritis (RA), and to compare the volumes with erosion scores for CT, MRI and radiography. Methods: In total, 17 patients with RA and four healthy controls underwent unilateral CT, MRI and radiography of second to fifth MCP joints in one hand. Erosion volumes (using OSIRIS software) and scores were determined from CT, MRI and radiography (scores only). Results: CT, MRI and radiography detected 77, 62 and 12 erosions, respectively. On CT, the mean erosion volume was 26 mm3 (median 10; range 0 to 248) and 30 mm3 (18; 1 to 163) on MRI. Total erosion volumes (per patient/control) were 97 mm3 (29; 0 to 485) on CT and 90 mm3 (46; 0 to 389) on MRI. For volumes, Spearman correlation coefficients were 0.96 to 0.99 (CT vs CT), 0.95 to 0.98 (MRI vs MRI) and 0.64 to 0.89 (CT vs MRI), all p<0.01. MRI erosion volumes correlated with the Outcome Measures in Rheumatology Clinical Trials/Rheumatoid Arthritis Magnetic Resonance Imaging Score (OMERACT RAMRIS) erosion scores (0.91 to 0.99; p<0.01) and the Sharp/van der Heijde erosion score (0.49 to 0.63; p<0.01). Conclusion: Very high intramodality and high intermodality agreements of CT and MRI erosion volumes were found, encouraging further testing in longitudinal studies. A close correlation with CT and MRI erosion volumes supports the OMERACT RAMRIS erosion score as a valid measure of joint destruction in RA.


The Journal of Rheumatology | 2011

The OMERACT ultrasound task force - Status and perspectives

Esperanza Naredo; Richard J. Wakefield; Annamaria Iagnocco; Lene Terslev; Emilio Filippucci; Frédérique Gandjbakhch; Philippe Aegerter; Sibel Zehra Aydin; M. Backhaus; Peter V. Balint; George A. W. Bruyn; Paz Collado; Stephanie Finzel; Jane Freeston; Marwin Gutierrez; Frederick Joshua; Sandrine Jousse-Joulin; David Kane; Helen I. Keen; Ingrid Möller; Peter Mandl; Sarah Ohrndorf; Carlos Pineda; Wolfgang A. Schmidt; Marcin Szkudlarek; Philip G. Conaghan; Maria Antonietta D'Agostino

This article reports the most recent work of the Outcome Measures in Rheumatology (OMERACT) Ultrasound Task Force, and highlights the future research priorities discussed at the OMERACT 10 meeting. Results of the following studies were presented: (1) intra- and interobserver reliability of ultrasound detecting and scoring synovitis in different joints of patients with rheumatoid arthritis (RA); (2) systematic review of previous ultrasound scoring systems of synovitis in RA; (3) enthesitis systematic review and Delphi definition exercise in spondyloarthritis enthesitis; (4) enthesitis intra- and interobserver reliability exercise; and (5) Delphi definition exercise in hand osteoarthritis, and reliability exercises. Study conclusions were discussed, and a future research agenda was approved, notably further validation of an OMERACT ultrasound global synovitis score (GLOSS) in RA, emphasizing the importance of testing feasibility, predictive value, and added value over standard clinical variables. Future research areas will include validating scoring systems for enthesitis and osteoarthritis, and testing the metric qualities of ultrasound for evaluating tenosynovitis and structural damage in RA.

Collaboration


Dive into the Marcin Szkudlarek's collaboration.

Top Co-Authors

Avatar

Esperanza Naredo

Complutense University of Madrid

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lene Terslev

University of Copenhagen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peter V. Balint

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Emilio Filippucci

Marche Polytechnic University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Annamaria Iagnocco

Sapienza University of Rome

View shared research outputs
Researchain Logo
Decentralizing Knowledge