Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Maria Rubini Gimenez is active.

Publication


Featured researches published by Maria Rubini Gimenez.


International Journal of Cardiology | 2013

Rapid rule out of acute myocardial infarction using undetectable levels of high-sensitivity cardiac troponin

Maria Rubini Gimenez; Rebeca Hoeller; Tobias Reichlin; Christa Zellweger; Raphael Twerenbold; Miriam Reiter; Berit Moehring; Karin Wildi; Tamina Mosimann; Mira Mueller; Bernadette Meller; Thomas Hochgruber; Ronny Ziller; Seoung Mann Sou; Karsten Murray; Konstantin Sakarikos; Susanne Ernst; Joaquim Gea; Isabel Campodarve; Carles Vilaplana; Philip Haaf; Stephan Steuer; Jan Minners; Stefan Osswald; Christian Mueller

BACKGROUND We examined whether undetectable levels of high-sensitivity cardiac Troponin (hs-cTn) can be used to rule out acute myocardial infarction (AMI) with a single blood draw at presentation to the emergency department (ED). METHODS AND RESULTS In a prospective multicenter study we used 4 different hs-cTn assays (hs-cTnT Roche, and hs-cTnI Siemens, hs-cTnI Beckman Coulter and hs-cTnI Abbott) in consecutive patients presenting with acute chest pain. The final diagnosis of AMI was adjudicated by two independent cardiologists using all available data including serial hs-cTnT levels. Mean follow up was 24 months. Among 2072 consecutive patients with available hs-cTnT levels, 21% had an adjudicated diagnosis of AMI. Among AMI patients, 98.2% had initially detectable levels of hs-cTnT (sensitivity 98.2%, 95%CI 96.3%-99.2%, negative predictive value (NPV) 98.6%, 95%CI 97.0%-99.3%). Undetectable levels of hs-cTnT ruled out AMI in 26.5% of patients at presentation. The NPV was similar with the three hs-cTnI assays: among 1180 consecutive patients with available hs-cTnI (Siemens), the NPV was 98.8%; among 1151 consecutive patients with available hs-cTnI (Beckman Coulter), the NPV was 99.2%; among 1567 consecutive patients with available hs-cTnI (Abbott), the NPV was 100.0%. The percentage of patients with undetectable levels of hs-cTnI was similar among the three hs-cTnI assays and ranged from 11.4% to 13.9%. CONCLUSIONS Undetectable levels of hs-cTn at presentation have a very high NPV and seem to allow the simple and rapid rule out of AMI. This criteria applies to much more patients with hs-TnT as compared to the investigated hs-cTnI assays.


Canadian Medical Association Journal | 2015

Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay

Tobias Reichlin; Raphael Twerenbold; Karin Wildi; Maria Rubini Gimenez; Nathalie Bergsma; Philip Haaf; Sophie Druey; Christian Puelacher; Berit Moehring; Michael Freese; Claudia Stelzig; Lian Krivoshei; Petra Hillinger; Cedric Jäger; Thomas Herrmann; Philip Kreutzinger; Milos Radosavac; Kateryna Pershyna; Ursina Honegger; Max Wagener; Thierry Vuillomenet; Isabel Campodarve; Roland Bingisser; Òscar Miró; Katharina Rentsch; Stefano Bassetti; Stefan Osswald; Christian Mueller

Background: We aimed to prospectively validate a novel 1-hour algorithm using high-sensitivity cardiac troponin T measurement for early rule-out and rule-in of acute myocardial infarction (MI). Methods: In a multicentre study, we enrolled 1320 patients presenting to the emergency department with suspected acute MI. The high-sensitivity cardiac troponin T 1-hour algorithm, incorporating baseline values as well as absolute changes within the first hour, was validated against the final diagnosis. The final diagnosis was then adjudicated by 2 independent cardiologists using all available information, including coronary angiography, echocardiography, follow-up data and serial measurements of high-sensitivity cardiac troponin T levels. Results: Acute MI was the final diagnosis in 17.3% of patients. With application of the high-sensitivity cardiac troponin T 1-hour algorithm, 786 (59.5%) patients were classified as “rule-out,” 216 (16.4%) were classified as “rule-in” and 318 (24.1%) were classified to the “observational zone.” The sensitivity and the negative predictive value for acute MI in the rule-out zone were 99.6% (95% confidence interval [CI] 97.6%–99.9%) and 99.9% (95% CI 99.3%–100%), respectively. The specificity and the positive predictive value for acute MI in the rule-in zone were 95.7% (95% CI 94.3%–96.8%) and 78.2% (95% CI 72.1%–83.6%), respectively. The 1-hour algorithm provided higher negative and positive predictive values than the standard interpretation of highsensitivity cardiac troponin T using a single cut-off level (both p < 0.05). Cumulative 30-day mortality was 0.0%, 1.6% and 1.9% in patients classified in the rule-out, observational and rule-in groups, respectively (p = 0.001). Interpretation: This rapid strategy incorporating high-sensitivity cardiac troponin T baseline values and absolute changes within the first hour substantially accelerated the management of suspected acute MI by allowing safe rule-out as well as accurate rule-in of acute MI in 3 out of 4 patients. Trial registration: ClinicalTrials.gov, NCT00470587


Circulation | 2015

Optimal Cutoff Levels of More Sensitive Cardiac Troponin Assays for the Early Diagnosis of Myocardial Infarction in Patients With Renal Dysfunction

Raphael Twerenbold; Karin Wildi; Cedric Jaeger; Maria Rubini Gimenez; Miriam Reiter; Tobias Reichlin; Astrid Walukiewicz; Mathias Gugala; Lian Krivoshei; Nadine Marti; Petra Hillinger; Christian Puelacher; Katharina Rentsch; Ursina Honegger; Carmela Schumacher; Felicitas Zurbriggen; Michael Freese; Claudia Stelzig; Isabel Campodarve; Stefano Bassetti; Stefan Osswald; Christian Mueller

Background— It is unknown whether more sensitive cardiac troponin (cTn) assays maintain their clinical utility in patients with renal dysfunction. Moreover, their optimal cutoff levels in this vulnerable patient population have not previously been defined. Methods and Results— In this multicenter study, we examined the clinical utility of 7 more sensitive cTn assays (3 sensitive and 4 high-sensitivity cTn assays) in patients presenting with symptoms suggestive of acute myocardial infarction. Among 2813 unselected patients, 447 (16%) had renal dysfunction (defined as Modification of Diet in Renal Disease–estimated glomerular filtration rate <60 mL·min−1·1.73 m−2). The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including coronary angiography and serial levels of high-sensitivity cTnT. Acute myocardial infarction was the final diagnosis in 36% of all patients with renal dysfunction. Among patients with renal dysfunction and elevated baseline cTn levels (≥99th percentile), acute myocardial infarction was the most common diagnosis for all assays (range, 45%–80%). In patients with renal dysfunction, diagnostic accuracy at presentation, quantified by the area under the receiver-operator characteristic curve, was 0.87 to 0.89 with no significant differences between the 7 more sensitive cTn assays and further increased to 0.91 to 0.95 at 3 hours. Overall, the area under the receiver-operator characteristic curve in patients with renal dysfunction was only slightly lower than in patients with normal renal function. The optimal receiver-operator characteristic curve–derived cTn cutoff levels in patients with renal dysfunction were significantly higher compared with those in patients with normal renal function (factor, 1.9–3.4). Conclusions— More sensitive cTn assays maintain high diagnostic accuracy in patients with renal dysfunction. To ensure the best possible clinical use, assay-specific optimal cutoff levels, which are higher in patients with renal dysfunction, should be considered. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT00470587.


European Heart Journal | 2014

Risk stratification in patients with acute chest pain using three high-sensitivity cardiac troponin assays

Philip Haaf; Tobias Reichlin; Raphael Twerenbold; Rebeca Hoeller; Maria Rubini Gimenez; Christa Zellweger; Berit Moehring; Catherine Fischer; Bernadette Meller; Karin Wildi; Michael Freese; Claudia Stelzig; Tamina Mosimann; Miriam Reiter; Mira Mueller; Thomas Hochgruber; Seoung Mann Sou; Karsten Murray; Jan Minners; Heike Freidank; Stefan Osswald; Christian Mueller

AIMS Several high-sensitivity cardiac troponin (hs-cTn) assays have recently been developed. It is unknown which hs-cTn provides the most accurate prognostic information and to what extent early changes in hs-cTn predict mortality. METHODS AND RESULTS In a prospective, international multicentre study, cTn was simultaneously measured with three novel [high-sensitivity cardiac Troponin T (hs-cTnT), Roche Diagnostics; hs-cTnI, Beckman-Coulter; hs-cTnI, Siemens] and a conventional assay (cTnT, Roche Diagnostics) in a blinded fashion in 1117 unselected patients with acute chest pain. Patients were followed up 2 years regarding mortality. Eighty-two (7.3%) patients died during the follow-up. The 2-year prognostic accuracy of hs-cTn was most accurate for hs-cTnT [area under the receivers operating characteristic curve (AUC) 0.78 (95% CI: 0.73-0.83) and outperformed both hs-cTnI (Beckman-Coulter, 0.71 (95% CI: 0.65-0.77; P = 0.001 for comparison), hs-cTnI (Siemens) 0.70 (95% CI: 0.64-0.76; P < 0.001 for comparison)] and cTnT 0.67 (95% CI: 0.61-0.74; P < 0.001 for comparison). Absolute changes of hs-cTnT were more accurate than relative changes in predicting mortality, but inferior to presentation values of hs-cTnT. Combining changes of hs-cTnT within the first 6 h with their presentation values did not further improve prognostic accuracy. Similar results were obtained for both hs-cTnI assays regarding the incremental value of changes. Hs-cTn concentrations remained predictors of death in clinically challenging subgroups such as patients with pre-existing coronary artery disease, impaired renal function, and patients older than 75 years. CONCLUSION High-sensitivity cardiac Troponin T is more accurate than hs-cTnI in the prediction of long-term mortality. Changes of hs-cTn do not seem to further improve risk stratification beyond initial presentation values.


Heart | 2013

Normal presenting levels of high-sensitivity troponin and myocardial infarction

Rebeca Hoeller; Maria Rubini Gimenez; Tobias Reichlin; Raphael Twerenbold; Christa Zellweger; Berit Moehring; Karin Wildi; Michael Freese; Claudia Stelzig; Beate Hartmann; Melanie Stoll; Tamina Mosimann; Miriam Reiter; Philip Haaf; Mira Mueller; Bernadette Meller; Thomas Hochgruber; Cathrin Balmelli; Seoung Mann Sou; Karsten Murray; Heike Freidank; Stephan Steuer; Jan Minners; Stefan Osswald; Christian Mueller

Objective To analyse whether levels of high-sensitivity cardiac troponin (hs-cTn) below their respective 99th percentile can be used as a single parameter to rule out acute myocardial infarction (AMI) at presentation. Design Prospective, multicentre study. Main outcome measures We measured hs-cTn using four different methods (hs-cTnT Roche, hs-cTnI Siemens, hs-cTnI Beckman Coulter and hs-cTnI Abbott) in consecutive patients presenting to the emergency department with acute chest pain. Two independent cardiologists adjudicated the final diagnosis. Patients were followed for death or AMI during a mean period of 24 months. Results Among 2072 consecutive patients with hs-cTnT measurements available, 21.4% had an adjudicated diagnosis of AMI (sensitivity 89.6%, 95% CI 86.4% to 92.3%, negative predictive value (NPV): 96.5%, 95% CI 95.4% to 97.4%). Among 1180 consecutive patients with hs-cTnI Siemens measurements available, 20.0% had AMI (sensitivity 94.1%, 95% CI 90.3% to 96.7%, NPV: 98.0%, 95% CI: 96.6% to 98.9%). Among 1151 consecutive patients with hs-cTnI Beckman Coulter measurements available, 19.7% had AMI (sensitivity 92.1%, 95% CI 87.8% to 95.2%, NPV: 97.5%, 95% CI 96.0% to 98.5%). Among 1567 consecutive patients with hs-cTnI Abbott measurements available, 20.0% had AMI (sensitivity 77.2%, 95% CI 72.1% to 81.7%, NPV: 94.3%, 95% CI 92.8% to 95.5%). Conclusions Normal hs-cTn levels at presentation should not be used as a single parameter to rule out AMI as 6%–23% of adjudicated AMI cases had normal levels of hs-cTn levels at presentation. Our data highlight the lack of standardisation among hs-cTnI assays resulting in substantial differences in sensitivity and NPV at the 99th percentile.


European Heart Journal | 2016

Impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction

Raphael Twerenbold; Cedric Jaeger; Maria Rubini Gimenez; Karin Wildi; Tobias Reichlin; Thomas Nestelberger; Jasper Boeddinghaus; Karin Grimm; Christian Puelacher; Berit Moehring; Gil Pretre; Nicolas Schaerli; Isabel Campodarve; Katharina Rentsch; Stephan Steuer; Stefan Osswald; Christian Mueller

Aims High-sensitivity cardiac troponin (hs-cTn) assays provide higher diagnostic accuracy for acute myocardial infarction (AMI) when compared with conventional assays, but may result in increased use of unnecessary coronary angiographies due to their increased detection of cardiomyocyte injury in conditions other than AMI. Methods and results We evaluated the impact of the clinical introduction of high-sensitivity cardiac troponin T (hs-cTnT) on the use of coronary angiography, stress testing, and time to discharge in 2544 patients presenting with symptoms suggestive of AMI to the emergency department (ED) within a multicentre study either before (1455 patients) or after (1089 patients) hs-cTnT introduction. Acute myocardial infarction was more often the clinical discharge diagnosis after hs-cTnT introduction (10 vs. 14%, P < 0.001), while unstable angina less often the clinical discharge diagnosis (14 vs. 9%, P = 0.007). The rate of coronary angiography was similar before and after the introduction of hs-cTnT (23 vs. 23%, P = 0.092), as was the percentage of coronary angiographies showing no stenosis (11 vs. 7%, P = 0.361). In contrast, the use of stress testing was substantially reduced from 29 to 19% (P < 0.001). In outpatients, median time to discharge from the ED decreased by 79 min (P < 0.001). Mean total costs decreased by 20% in outpatients after the introduction of hs-cTnT (P = 0.002). Conclusion The clinical introduction of hs-cTn does not lead to an increased or inappropriate use of coronary angiography. Introduction of hs-cTn is associated with an improved rule-out process and thereby reduces the need for stress testing and time to discharge. Clinical Trial Registration Information www.clinicaltrials.gov. Identifier, NCT00470587.


American Heart Journal | 2013

Risk stratification in patients with unstable angina using absolute serial changes of 3 high-sensitive troponin assays

Tobias Reichlin; Raphael Twerenbold; Claudia Maushart; Miriam Reiter; Berit Moehring; Nora Schaub; Cathrin Balmelli; Maria Rubini Gimenez; Rebeca Hoeller; Konstantin Sakarikos; Beatrice Drexler; Philip Haaf; Stefan Osswald; Christian Mueller

BACKGROUND It is unknown whether unstable angina (UA) results in previously nondetectable low-level myocardial necrosis. We compared the pattern of myocardial necrosis between patients with UA, acute myocardial infarction (AMI), and noncardiac chest pain (NCCP) using 3 high-sensitive cardiac troponin (hs-cTn) assays. METHODS In a multicenter study, we enrolled 842 unselected patients with acute chest pain in the emergency department. Roche hs-cTnT, Beckman Coulter hs-cTnI, and Siemens hs-cTnI were determined in a blinded fashion at presentation and after 1, 2, 3, and 6 hours. The final diagnosis was adjudicated by 2 independent cardiologists. RESULTS A change in hs-cTn of ≥2 ng/L within the first hour after presentation as assessed with Roche hs-cTnT, Beckman Coulter hs-cTnI, and Siemens hs-cTnI was observed in 26%, 31%, and 32% of patients with UA (n = 115) compared with 91%, 92%, and 96% in patients with AMI (n = 120) and 12%, 23%, and 16% in patients with NCCP (n = 415; P < .001 for all comparisons between UA and AMI, P > .05 for all comparisons between UA and NCCP). In patients with UA, such a 1-hour change in hs-cTn of ≥2 ng/L was associated with an increased risk of death or AMI during the 30-day follow-up (P = .003, .03, .03) and 2-year follow-up (P < .001, .002, and .006). CONCLUSIONS In marked contrast to patients with AMI, most patients with UA do not exhibit relevant hs-cTn changes. The minority of UA with hs-cTn changes, however, has a significantly worse short- and long-term outcome.


Circulation | 2017

Direct Comparison of 4 Very Early Rule-Out Strategies for Acute Myocardial Infarction Using High-Sensitivity Cardiac Troponin I

Jasper Boeddinghaus; Thomas Nestelberger; Raphael Twerenbold; Karin Wildi; Patrick Badertscher; Janosch Cupa; Tobias Bürge; Patrick Mächler; Sydney Corbière; Karin Grimm; Maria Rubini Gimenez; Christian Puelacher; Samyut Shrestha; Dayana Flores Widmer; Jakob Fuhrmann; Petra Hillinger; Zaid Sabti; Ursina Honegger; Nicolas Schaerli; Nikola Kozhuharov; Katharina Rentsch; Òscar Miró; Beatriz López; F. Javier Martín-Sánchez; Esther Rodríguez-Adrada; Beata Morawiec; Damian Kawecki; Eva Ganovská; Jiri Parenica; Jens Lohrmann

Background: Four strategies for very early rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I (hs-cTnI) have been identified. It remains unclear which strategy is most attractive for clinical application. Methods: We prospectively enrolled unselected patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. Hs-cTnI levels were measured at presentation and after 1 hour in a blinded fashion. We directly compared all 4 hs-cTnI–based rule-out strategies: limit of detection (LOD, hs-cTnI<2 ng/L), single cutoff (hs-cTnI<5 ng/L), 1-hour algorithm (hs-cTnI<5 ng/L and 1-hour change<2 ng/L), and the 0/1-hour algorithm recommended in the European Society of Cardiology guideline combining LOD and 1-hour algorithm. Results: Among 2828 enrolled patients, acute myocardial infarction was the final diagnosis in 451 (16%) patients. The LOD approach ruled out 453 patients (16%) with a sensitivity of 100% (95% confidence interval [CI], 99.2%–100%), the single cutoff 1516 patients (54%) with a sensitivity of 97.1% (95% CI, 95.1%–98.3%), the 1-hour algorithm 1459 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%–99.2%), and the 0/1-hour algorithm 1463 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%–99.2%). Predefined subgroup analysis in early presenters (⩽2 hours) revealed significantly lower sensitivity (94.2%, interaction P=0.03) of the single cutoff, but not the other strategies. Two-year survival was 100% with LOD and 98.1% with the other strategies (P<0.01 for LOD versus each of the other strategies). Conclusions: All 4 rule-out strategies balance effectiveness and safety equally well. The single cutoff should not be applied in early presenters, whereas the 3 other strategies seem to perform well in this challenging subgroup. Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00470587.


European heart journal. Acute cardiovascular care | 2017

Quality indicators for acute myocardial infarction: A position paper of the Acute Cardiovascular Care Association

Francois Schiele; Chris P Gale; Eric Bonnefoy; Frédéric Capuano; Marc J. Claeys; Nicolas Danchin; Keith A.A. Fox; Kurt Huber; Zaza Iakobishvili; Maddalena Lettino; Tom Quinn; Maria Rubini Gimenez; Hans Erik Bøtker; Eva Swahn; Adam Timmis; Marco Tubaro; Christiaan J. Vrints; David Walker; Doron Zahger; Uwe Zeymer; Héctor Bueno

Evaluation of quality of care is an integral part of modern healthcare, and has become an indispensable tool for health authorities, the public, the press and patients. However, measuring quality of care is difficult, because it is a multifactorial and multidimensional concept that cannot be estimated solely on the basis of patients’ clinical outcomes. Thus, measuring the process of care through quality indicators (QIs) has become a widely used practice in this context. Other professional societies have published QIs for the evaluation of quality of care in the context of acute myocardial infarction (AMI), but no such indicators exist in Europe. In this context, the European Society of Cardiology (ESC) Acute Cardiovascular Care Association (ACCA) has reflected on the measurement of quality of care in the context of AMI (ST segment elevation myocardial infarction (STEMI) and non-ST segment elevation myocardial infarction (NSTEMI)) and created a set of QIs, with a view to developing programmes to improve quality of care for the management of AMI across Europe. We present here the list of QIs defined by the ACCA, with explanations of the methodology used, scientific justification and reasons for the choice for each measure.


Journal of the American College of Cardiology | 2017

Clinical Use of High-Sensitivity Cardiac Troponin in Patients With Suspected Myocardial Infarction

Raphael Twerenbold; Jasper Boeddinghaus; Thomas Nestelberger; Karin Wildi; Maria Rubini Gimenez; Patrick Badertscher; Christian Mueller

High-sensitivity cardiac troponin (hs-cTn) assays have been used clinically by thousands of physicians in many countries throughout the world since their clinical introduction 7 years ago. In the early diagnosis of myocardial infarction (MI), beyond doubt, the most important indication of hs-cTn assays, these simple, inexpensive, and highly reproducible tools complement detailed clinical assessment including chest pain characteristics and the electrocardiogram. Hs-cTn assays for the first time allowed the precise quantification of cardiomyocyte injury around the 99th percentile and thereby substantially increased the accuracy of MI detection from blood obtained at presentation to the emergency department (ED). Higher accuracy at ED presentation enabled the development and extensive validation of early hs-cTn-based diagnostic algorithms, which substantially reduced the time required for the safe rule-out or rule-in of MI. This review summarizes key principles underlying the safe and effective use of hs-cTn in the ED in patients with suspected MI.

Collaboration


Dive into the Maria Rubini Gimenez's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Christian Mueller

University of Massachusetts Medical School

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge