Marie T. Krüger
University Medical Center Freiburg
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Marie T. Krüger.
Journal of Spinal Disorders & Techniques | 2014
Jan-Helge Klingler; Ronen Sircar; Christian Scheiwe; Evangelos Kogias; Marie T. Krüger; Christoph Scholz; Ulrich Hubbe
Study Design: A radiation exposure study in vitro. Objective: This study aimed to compare the radiation exposure of 2 different 3-dimensional (3D) C-arm devices on an anthropomorphic phantom. Summary of Background Data: Minimally invasive pedicle screw placement requires intraoperative imaging techniques for visualization of the unexposed spine. Mobile 3D C-arms compose a 3D image data set out of multiple successive fluoroscopic images. Methods: We compared the 3D C-arm devices Siremobil Iso-C 3D (Siemens Sector Healthcare, Erlangen, Germany) and Vision FD Vario 3D (Ziehm Imaging, Nuremberg, Germany) regarding their radiation exposure. For this purpose, dosimeters were attached on an anthropomorphic phantom at various sites (eye lenses, thyroid gland, female, and male gonads). With each C-arm, 10 automated 3D scans as well as 400 fluoroscopic images were performed on the cervical and lumbar spine, respectively. Results: The Vision FD Vario 3D generally causes higher radiation exposures than the Siremobil Iso-C 3D. Significantly higher radiation exposures were assessed at the eye lenses performing cervical (294.1 vs. 84.6 &mgr;Sv) and lumbar 3D scans (22.5 vs. 11.2 &mgr;Sv) as well as at the thyroid gland performing cervical 3D scans (4405.2 vs. 2761.9 &mgr;Sv). Moreover, the Vision FD Vario 3D caused significantly higher radiation exposure at the eye lenses for standard cervical fluoroscopic images (3.2 vs. 0.4 &mgr;Sv). Conclusions: 3D C-arms facilitate minimally invasive and accurate pedicle screw placement by providing 3D image datasets for intraoperative 3D imaging and navigation. However, the hereby potentially increased radiation exposure has to be considered. In particular, the Vision FD Vario 3D appears to generally evoke higher radiation exposures than the Siremobil Iso-C 3D. Well-indicated application of ionizing radiation and compliance with radiation protection principles remain mandatory to keep radiation exposure to patient and staff as low as reasonably achievable.
The Scientific World Journal | 2014
Jan-Helge Klingler; Marie T. Krüger; Ronen Sircar; Evangelos Kogias; Christoph Scholz; Florian Volz; Christian Scheiwe; Ulrich Hubbe
Purpose. To compare radiographic and clinical outcomes after anterior cervical discectomy in patients with cervical degenerative disc disease using PEEK cages or PMMA spacers with a minimum 1-year follow-up. Methods. Anterior cervical discectomy was performed in 107 patients in one or two levels using empty PEEK cages (51 levels), Sulcem PMMA spacers (49 levels) or Palacos PMMA spacers (41 levels) between January, 2005 and February, 2009. Bony fusion, subsidence, and sagittal alignment were retrospectively assessed in CT scans and radiographs at follow-up. Clinical outcome was measured using the VAS, NDI, and SF-36. Results. Bony fusion was assessed in 65% (PEEK cage), 57% (Sulcem), and 46% (Palacos) after a mean follow-up of 2.5 years. Mean subsidence was 2.3–2.6 mm without significant differences between the groups. The most pronounced loss of lordosis was found in PEEK cages (−4.1°). VAS was 3.1 (PEEK cage), 3.6 (Sulcem), and 2.7 (Palacos) without significant differences. Functional outcome in the PEEK cage and Palacos group was superior to the Sulcem group. Conclusions. The substitute groups showed differing fusion rates. Clinical outcome, however, appears to be generally not correlated with fusion status or subsidence. We could not specify a superior disc substitute for anterior cervical discectomy. This trial is registered with DRKS00003591.
Journal of Spinal Disorders & Techniques | 2014
Jan-Helge Klingler; Ronen Sircar; Christian Scheiwe; Evangelos Kogias; Florian Volz; Marie T. Krüger; Ulrich Hubbe
Study Design: This was a retrospective analysis. Objective: This study compares 2 different 3-dimensional (3D) C-arm devices for intraoperative imaging and navigation with regard to clinical applicability and image quality. Summary of Background Data: Minimally invasive spine surgery requires intraoperative imaging techniques to adequately visualize the unexposed spine. For this purpose, mobile 3D C-arms became available along with the evolution of intraoperative navigation techniques. Methods: The C-arm devices Siremobil Iso-C 3D (Siemens) and Vision FD Vario 3D (Ziehm) perform an automated orbital rotation around the patient acquiring a 3D image set out of multiple successive fluoroscopic images. We report on technical specifications of the C-arms and our daily experience regarding clinical applicability. Furthermore, 5 spine surgeons evaluated blinded triplanar planes of 40 cervical, thoracic, and lumbar 3D scans that were obtained during routine surgery regarding usability for navigation. We assessed the delineation of cortical bone, artifacts, and overall image quality using a 0–10 numeric rating scale. Results: The Siremobil Iso-C 3D requires 128 seconds for its 190-degree scanning arc with equidistant isocenter. The Vision FD Vario 3D performs an elliptical scanning arc and completes its 135-degree scan in 64 seconds; furthermore, it features a flat panel detector and fully digital imaging. The smaller dimensions of the Vision FD Vario 3D made it easier to maneuver in the operating room compared with the more bulky Siremobil Iso-C 3D. With respect to image quality in cervical 3D scans, the Siremobil Iso-C 3D reached significantly higher scores in all categories. The Vision FD Vario 3D revealed less artifacts in lumbar 3D scans. Conclusions: The Siremobil Iso-C 3D provides high-quality 3D scans in slender spine regions (eg, cervical spine), whereas the Vision FD Vario 3D appears to have advantages in the lumbar spine. Further evolution and novel devices are needed to optimize image quality and handling.
The Scientific World Journal | 2015
Jan-Helge Klingler; Christoph Scholz; Evangelos Kogias; Ronen Sircar; Marie T. Krüger; Florian Volz; Christian Scheiwe; Ulrich Hubbe
Purpose. To describe the minimally invasive technique for cement augmentation of cannulated and fenestrated screws using an injection cannula as well as to report its safety and efficacy. Methods. A total of 157 cannulated and fenestrated pedicle screws had been cement-augmented during minimally invasive posterior screw-rod spondylodesis in 35 patients from January to December 2012. Retrospective evaluation of cement extravasation and screw loosening was carried out in postoperative plain radiographs and thin-sliced triplanar computed tomography scans. Results. Twenty-seven, largely prevertebral cement extravasations were detected in 157 screws (17.2%). None of the cement extravasations was causing a clinical sequela like a new neurological deficit. One screw loosening was noted (0.6%) after a mean follow-up of 12.8 months. We observed no cementation-associated complication like pulmonary embolism or hemodynamic insufficiency. Conclusions. The presented minimally invasive cement augmentation technique using an injection cannula facilitates convenient and safe cement delivery through polyaxial cannulated and fenestrated screws during minimally invasive screw-rod spondylodesis. Nevertheless, the optimal injection technique and design of fenestrated screws have yet to be identified. This trial is registered with German Clinical Trials DRKS00006726.
Neurosurgery | 2013
Sven Gläsker; Marie T. Krüger; Jan-Helge Klingler; M. Wlodarski; Julia Klompen; Bawarjan Schatlo; Beate Hippchen; Hartmut P. H. Neumann; Vera van Velthoven
BACKGROUND Neurogenic polyglobulia occurs with central nervous system hemangioblastomas. Among the suggested mechanisms are extramedullary hematopoiesis in the tumor tissue and germline mutations of the von Hippel-Lindau (VHL) tumor suppressor gene. OBJECTIVE To determine the frequency and driving mechanisms of polyglobulia in central nervous system hemangioblastomas. METHODS We performed a retrospective analysis of pre- and postoperative (at 3 and 12 months) hemoglobin levels in a consecutive series of patients with hemangioblastomas operated on in our institution from 1996 to 2009. We performed molecular genetic analyses for mutations of the VHL tumor suppressor gene. RESULTS Preoperative hemoglobin levels were available from 164 patients. The average hemoglobin level (15.2 g/dL in males and 13.1 g/dL in females) was within normal range according to our standards. Of 22 patients with increased preoperative hemoglobin levels (>17 g/dL in males and >15 g/dL in females), 8 presented with pathological hemoglobin (>18.5 g/dL in males and >16.5 g/dL in females) according to World Health Organization criteria. Surgical removal of the hemangioblastoma resulted in a permanent cure of polyglobulia in all patients. Six of the 8 patients with pathological hemoglobin elevation carried a germline mutation of the VHL tumor suppressor gene. CONCLUSION Neurogenic polyglobulia occurs in a subset of patients with hemangioblastomas. This phenomenon is mostly observed in VHL mutation carriers, but also occurs in patients with sporadic hemangioblastomas. Removal of the tumor results in the permanent cure of polyglobulia. Our observations suggest that polyglobulia is an effect by the tumor itself, either due to paraneoplasia or extramedullary hematopoiesis.
Trials | 2015
Ulrich Hubbe; Ronen Sircar; Christian Scheiwe; Christoph Scholz; Evangelos Kogias; Marie T. Krüger; Florian Volz; Jan-Helge Klingler
BackgroundSome symptomatic degenerative conditions of the lumbar spine may be treated with spinal fusion if conservative treatment has failed. The minimally invasive technique of transforaminal lumbar interbody fusion (MIS TLIF) is increasingly used but has been found to generate increased radiation exposure to the patient and staff. Modern three-dimensional (3D) C-arm devices are capable of providing conventional two-dimensional fluoroscopic images (x-rays) as well as 3D image sets for intraoperative navigation. This study was designed to compare the radiation exposure between these two intraoperative imaging techniques in MIS TLIF procedures.MethodsThis study is a randomized controlled trial. Forty participants scheduled to undergo monosegmental MIS TLIF will be recruited and randomly allocated to one of two groups with respect to the applied intraoperative imaging technique: conventional fluoroscopy (FLUORO group) and 3D fluoroscopy-based navigation combined with conventional fluoroscopy (NAV group). Furthermore, patients scheduled to undergo bisegmental MIS TLIF during the recruitment period for monosegmental MIS TLIF will be assessed for eligibility and will be randomly assigned separately. The primary endpoint is the radiation exposure to the surgeon and is measured by dosimeter readings. Secondary endpoints are the radiation exposure to the assistant surgeon, scrub nurse, anesthetist, patient, and C-arm as well as radiation exposure in relation to the body mass index of the patient.DiscussionResults of this randomized study will help to compare the radiation exposure to the operating staff and patient during MIS TLIF procedures using conventional fluoroscopy versus 3D fluoroscopy-based navigation combined with conventional fluoroscopy. Furthermore, recommendations regarding the appropriate use of the investigated intraoperative imaging techniques will be made to improve radiation protection and to reduce radiation exposure.Trial registrationRegistration number of the German Clinical Trials Register: DRKS00004514. Registration date: 11 August 2012.
The Scientific World Journal | 2015
Jan-Helge Klingler; Florian Volz; Marie T. Krüger; Evangelos Kogias; Roland Rölz; Christoph Scholz; Ronen Sircar; Ulrich Hubbe
Purpose. To assess the frequency, risk factors, and management of accidental durotomy in minimally invasive transforaminal lumbar interbody fusion (MIS TLIF). Methods. This single-center study retrospectively investigates 372 patients who underwent MIS TLIF and were mobilized within 24 hours after surgery. The frequency of accidental durotomies, intraoperative closure technique, body mass index, and history of previous surgery was recorded. Results. We identified 32 accidental durotomies in 514 MIS TLIF levels (6.2%). Analysis showed a statistically significant relation of accidental durotomies to overweight patients (body mass index ≥25 kg/m2; P = 0.0493). Patient age older than 65 years tended to be a positive predictor for accidental durotomies (P = 0.0657). Mobilizing patients on the first postoperative day, we observed no durotomy-associated complications. Conclusions. The frequency of accidental durotomies in MIS TLIF is low, with overweight being a risk factor for accidental durotomies. The minimally invasive approach seems to minimize durotomy-associated complications (CSF leakage, pseudomeningocele) because of the limited dead space in the soft tissue. Patients with accidental durotomy can usually be mobilized within 24 hours after MIS TLIF without increased risk. The minimally invasive TLIF technique might thus be beneficial in the prevention of postoperative immobilization-associated complications such as venous thromboembolism. This trial is registered with DRKS00006135.
Journal of Neurosurgery | 2015
Jan-Helge Klingler; Marie T. Krüger; Evangelos Kogias; Stefanie M. Brendecke; Ulrich Hubbe; Christian Scheiwe
Malignant meningiomas are a rare but aggressive subset of intracranial meningiomas leading to a very limited life expectancy. The occurrence of spinal metastases in these tumors is an even rarer event. The described patient had an intracranial malignant meningioma and developed a symptomatic osteolytic contrast-enhancing lesion in the left C-1 lateral mass suspicious for metastasis. The authors performed a minimally invasive posterior resection of the lesion with vertebroplasty of C-1. Histopathology verified metastasis of the malignant meningioma. The surgical procedure resulted in prompt and permanent pain reduction until the patient died 18 months later. Given the very limited life expectancy in this case, the authors did not consider occipitocervical fusion because of their desire to preserve the range of motion of the head. Therefore, they suggest minimally invasive tumor resection and vertebroplasty in selected palliative tumor patients.
Journal of Stroke & Cerebrovascular Diseases | 2013
Jan-Helge Klingler; Marie T. Krüger; Johannes R. Lemke; Cordula Jilg; Vera van Velthoven; Josef Zentner; Hartmut P. H. Neumann; Sven Gläsker
BACKGROUND The rupture of intracranial aneurysms leads to subarachnoid hemorrhage, which is often associated with poor outcome. Preventive treatment of unruptured intracranial aneurysms is possible and recommended. However, the lack of candidate genes precludes identifying patients at risk by genetic analyses. We observed intracranial aneurysms in 2 patients with von Hippel-Lindau (VHL) disease and the known disease-causing mutation c.292T > C (p.Tyr98His) in the VHL tumor suppressor gene. This study investigates whether the VHL gene is a possible candidate gene for aneurysm formation. METHODS Patients with intracranial aneurysms admitted to our department between 2006 and 2009 were enrolled. The peripheral leukocyte DNA of 200 patients was investigated for sequence variations in the VHL gene using denaturing high performance liquid chromatography. Peripheral leukocyte DNA of 100 randomly sampled probands was investigated as a control group. The allelic frequencies of sequence variations between both groups were compared using the Fisher exact test. RESULTS Fourteen of 200 patients with intracranial aneurysms had sequence variations at 6 different loci in the VHL gene. In contrast, no sequence variations were identified in 100 probands in the control group (P = 0.0062). However, none of the single-sequence variations had a statistically significant difference in the allelic frequencies compared to the control group. CONCLUSIONS There is accumulating evidence for a genetic basis of aneurysm development. Our investigations lead to the conclusion that the VHL gene is potentially involved in the formation of intracranial aneurysms in a subset of patients. Additional candidate genes need to be identified in order to develop sensitive genetic screening for at-risk patients.
Geburtshilfe Und Frauenheilkunde | 2004
Marie T. Krüger; L. Quaas; V. van Velthoven; R. Hentschel; Sargon Ziyeh; Rudolf Korinthenberg