Marina R. Kaizer
New York University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Marina R. Kaizer.
Dental Materials | 2016
Fatma A. Shembish; Hui Tong; Marina R. Kaizer; Malvin N. Janal; Van P. Thompson; N.J.M. Opdam; Yu Zhang
OBJECTIVE To demonstrate the fatigue behavior of CAD/CAM resin composite molar crowns using a mouth-motion step-stress fatigue test. Monolithic leucite-reinforced glass-ceramic crowns were used as a reference. METHODS Fully anatomically shaped monolithic resin composite molar crowns (Lava Ultimate, n=24) and leucite reinforced glass-ceramic crowns (IPS Empress CAD, n=24) were fabricated using CAD/CAM systems. Crowns were cemented on aged dentin-like resin composite tooth replicas (Filtek Z100) with resin-based cements (RelyX Ultimate for Lava Ultimate or Multilink Automix for IPS Empress). Three step-stress profiles (aggressive, moderate and mild) were employed for the accelerated sliding-contact mouth-motion fatigue test. Twenty one crowns from each group were randomly distributed among these three profiles (1:2:4). Failure was designated as chip-off or bulk fracture. Optical and electron microscopes were used to examine the occlusal surface and subsurface damages, as well as the material microstructures. RESULTS The resin composite crowns showed only minor occlusal damage during mouth-motion step-stress fatigue loading up to 1700N. Cross-sectional views revealed contact-induced cone cracks in all specimens, and flexural radial cracks in 2 crowns. Both cone and radial cracks were relatively small compared to the crown thickness. Extending these cracks to the threshold for catastrophic failure would require much higher indentation loads or more loading cycles. In contrast, all of the glass-ceramic crowns fractured, starting at loads of approximately 450N. SIGNIFICANCE Monolithic CAD/CAM resin composite crowns endure, with only superficial damage, fatigue loads 3-4 times higher than those causing catastrophic failure in glass-ceramic CAD crowns.
Dental Materials | 2015
Herzl Chai; Marina R. Kaizer; Asima Chughtai; Hui Tong; C.B. Tanaka; Yu Zhang
OBJECTIVE A major limiting factor for the widespread use of zirconia in prosthetic dentistry is its poor resin-cement bonding capabilities. We show that this deficiency can be overcome by infiltrating the zirconia cementation surface with glass. Current methods for assessing the fracture resistance of resin-ceramic bonds are marred by uneven stress distribution at the interface, which may result in erroneous interfacial fracture resistance values. We have applied a wedge-loaded double-cantilever-beam testing approach to accurately measure the interfacial fracture resistance of adhesively bonded zirconia-based restorative materials. METHODS The interfacial fracture energy GC was determined for adhesively bonded zirconia, graded zirconia and feldspathic ceramic bars. The bonding surfaces were subjected to sandblasting or acid etching treatments. Baseline GC was measured for bonded specimens subjected to 7 days hydration at 37°C. Long-term GC was determined for specimens exposed to 20,000 thermal cycles between 5 and 55°C followed by 2-month aging at 37°C in water. The test data were interpreted with the aid of a 2D finite element fracture analysis. RESULTS The baseline and long-term GC for graded zirconia was 2-3 and 8 times greater than that for zirconia, respectively. More significantly, both the baseline and long-term GC of graded zirconia were similar to those for feldspathic ceramic. SIGNIFICANCE The interfacial fracture energy of feldspathic ceramic and graded zirconia was controlled by the fracture energy of the resin cement while that of zirconia by the interface. GC for the graded zirconia was as large as for feldspathic ceramic, making it an attractive material for use in dentistry.
Journal of Prosthodontic Research | 2013
Cássia F. Reginato; Aline S. Oliveira; Marina R. Kaizer; Patrícia S. Jardim; Rafael R. Moraes
PURPOSE To investigate the polymerization efficiency through translucent and opaque glass fiber posts and the bond strength of a self-adhesive resin to root dentin. METHODS Translucent and opaque silanated conical posts, identical in length, diameter and shape (n=8), were cemented to incisor bovine roots using RelyX Unicem Clicker. Photoactivation was performed only through the posts. The roots were transversally sectioned (cervical, middle and apical thirds) and the push-out test was carried out. Data were analyzed using two-way ANOVA and Fishers LSD method (5%). Failure modes were classified under magnification. An elastomer mold of a bovine incisor root was filled with flowable composite and the posts inserted into the mold. After photoactivation through the post and removal of unpolymerized material, the polymerization efficiency was estimated by percentage of mass gain (n=5). Data were analyzed using t-test (5%). RESULTS The bond strength of the translucent post was higher than the opaque post for all root thirds. For both posts the bond strength at the cervical third was higher than at the middle and apical thirds. A predominance of adhesive failures was detected for all conditions. Mixed failures were more frequently observed for the opaque post. Almost all the composite polymerized and bonded to the extension of the translucent post, whereas polymerization of the composite was restricted to the cervical area of the opaque post. CONCLUSIONS The use of translucent post may positively influence the polymerization efficiency and bond strength of resin cement to intraradicular dentin.
Dental Materials | 2016
Haifa El Zhawi; Marina R. Kaizer; Asima Chughtai; Rafael R. Moraes; Yu Zhang
OBJECTIVE To investigate fatigue fracture resistance and wear behavior of a polymer infiltrated ceramic network (PICN) material (ENAMIC, Vita Zahnfabrik). METHODS Anatomically shaped ENAMIC monolithic crowns were milled using a CAD/CAM system. The crowns were cemented on aged dentin-like composite abutments (Z100, 3M ESPE) with resin-based cement (Vita DUO Cement, Vita). The specimens were subjected to 2 types of fatigue and wear tests: (1) accelerated sliding-contact mouth-motion step-stress fatigue test (n=24) in water; and (2) long-term sliding-contact mouth-motion fatigue/wear test using a clinically relevant load (P=200N, n=8) in water. Failure was designated as chip-off or bulk fracture. Optical and scanning electron microscopes were used to examine the occlusal surface and subsurface damage, as well as to reveal the materials microstructure. In addition, wear volume and depth were measured by X-ray micro-computed tomography. RESULTS For accelerated mouth-motion step-stress fatigue testing, 3 out of the 24 ENAMIC crowns fractured following cyclic loading up to 1700N. Minor occlusal damage and contact-induced cone cracks were observed in all surviving specimens, but no flexural radial cracks were seen. For long-term mouth-motion fatigue/wear testing under a 200N load in water, a small wear scar without significant cracks was observed in all 8 tested ENAMIC crowns. SIGNIFICANCE Monolithic CAD/CAM ENAMIC crowns showed superior resistance to sliding-contact fatigue fracture and wear.
Journal of Prosthetic Dentistry | 2015
Júlia R. Almeida; Gabriela U. Schmitt; Marina R. Kaizer; Noéli Boscato; Rafael R. Moraes
STATEMENT OF PROBLEM The type of resin-based luting agent might influence the color stability of ceramic veneers. PURPOSE The purpose of this study was to investigate the effects of resin-based agents and aging on the color stability of ceramic veneers bonded to enamel. MATERIAL AND METHODS Ceramic disks were cemented to bovine enamel disks with 4 resin-based luting agents (n=10): dual-polymerizing cement (RelyX ARC), light-polymerizing cement (RelyX Veneer), flowable composite resin (Filtek Z350 Flow), or composite resin preheated for 30 minutes at 60°C (Filtek Z350 XT). CIE L*, a*, and b* color coordinates were measured 24 hours after cementation (baseline) with a color spectrophotometer and reevaluated after 10,000 and 20,000 thermal cycles. Color variation was calculated by using CIELab (ΔE*(ab)) and CIEDE2000 (ΔE00) methods. Then 95% confidence intervals were calculated for color variation means between baseline and 10,000 thermal cycles and between 10,000 and 20,000 thermal cycles. The 95% confidence intervals were also calculated for the means of individual color coordinates (L*, a*, and b*). RESULTS The dual-polymerizing cement had the highest color variation among all luting agents. No significant differences were found in color variation among the light-polymerizing materials. All agents showed ΔE*(ab)>3.46 and ΔE00>2.25 after 20,000 thermal cycles. Variations in L*, a*, and b* coordinates were material dependent. The dual-polymerizing agent was yellowish and reddish after aging. CONCLUSIONS The dual-polymerizing cement had higher color variation than the light-polymerized materials when used for bonding ceramic veneers to enamel. Flowable and preheated composite resins had similar color stability to that of light-polymerizing resin-based cement.
Brazilian Dental Journal | 2015
Noéli Boscato; Fernando Gabriel Hauschild; Marina R. Kaizer; Rafael R. Moraes
This study evaluated the masking ability of different porcelain thicknesses and combination of enamel and/or dentin porcelain layers over simulated background dental substrates with higher (A2) and lower (C4) color values. Combination of the enamel (E) and dentin (D) monolayer porcelain disks with different thicknesses (0.5 mm, 0.8 mm, and 1 mm) resulted in the following bilayer groups (n=10): D1E1, D1E0.8; D1E0.5; D0.8E0.8; D0.8E0.5, and D0.5E0.5. CIELAB color coordinates were measured with a spectrophotometer. The translucency parameter of mono and bilayer specimens and the masking ability estimated by color variation (ΔE*ab) of bilayer specimens over simulated dental substrates were evaluated. Linear regression analysis was used to investigate the relationships translucency parameter × ΔE*, translucency parameter × porcelain thickness, and ΔE* × porcelain thickness. Data were analyzed statistically (α= 0.05). Thinner porcelain disks were associated with higher translucency. Porcelain monolayers were considerably more translucent than bilayers (enamel + dentin). Dentin porcelain was less translucent than enamel porcelain with same thickness. ΔE* was always lower when measured over A2 background. Higher ΔE* was observed for the C4 background, indicating poorer masking ability. Increased ΔE* was significantly associated with increased translucency for both backgrounds. Decreased translucency and ΔE* were associated with increased total porcelain thickness or increased dentin thickness for both backgrounds. In conclusion, increased porcelain thickness (particularly increased dentin layer) and increased porcelain opacity resulted in better masking ability of the dental backgrounds.
Ceramics International | 2017
Marina R. Kaizer; Petra C. Gierthmuehlen; Mateus Bf dos Santos; S.S. Cava; Yu Zhang
The fabrication of zirconia dental restorations is a time-consuming process due to traditional slow sintering schemes; zirconia (Y-TZP) produced by these conventional routes are predominantly opaque. Novel speed sintering protocols have been developed to meet the demand for time and cost effective chairside CAD/CAM-produced restorations, as well as to control ceramic microstructures for better translucency. Although the speed sintering protocols have already been used to densify dental Y-TZP, the wear properties of these restorations remain elusive. Fast heating and cooling rates, as well as shorter sintering dwell times are known to affect the microstructure and properties of zirconia. Thus, we hypothesize that speed sintered zirconia dental restorations possess distinct wear and physical characteristics relative to their conventionally sintered counterparts. Glazed monolithic molar crowns of translucent Y-TZP (inCoris TZI, Sirona) were fabricated using three distinct sintering profiles: Super-speed (SS, 1580 °C, dwell time 10 min), Speed (S, 1510 °C, dwell time 25 min), and Long-term (LT, 1510 °C, dwell time 120 min). Microstructural, optical and wear properties were investigated. Crowns that were super-speed sintered possessed higher translucency. Areas of mild and severe wear were observed on the zirconia surface in all groups. Micropits in the wear crater were less frequent for the LT group. Groups S and SS exhibited more surface pits, which caused a scratched steatite surface that is associated with a greater volume loss. Tetragonal to monoclinic phase transformation, resulting from the sliding wear process, was present in all three groups. Although all test groups had withstood thermo-mechanical challenges, the presence of hairline cracks emanating from the occlusal wear facets and extending deep into the restoration indicates their susceptibility to fatigue sliding contact fracture.
Journal of Esthetic and Restorative Dentistry | 2016
Ana Paula Perroni; Camila Amaral; Marina R. Kaizer; Rafael R. Moraes; Noéli Boscato
OBJECTIVES This study evaluated the influence of different shades of flowable resin composite used as luting agent on the final shade of porcelain veneers of different opacities over A2 and B1 simulated dental substrate. MATERIALS AND METHODS One millimeter monolithic (enamel E1.0 or dentin D1.0) and bilayer (E0.5D0.5) porcelain discs shade A2 were paired with flowable resin composite disks (0.1 mm thick) of different shades (A1, A2, B1, white opaque - WO or IL - translucent), as veneer + luting agent (n = 10). The CIE L*a*b* color coordinates were measured with a spectrophotometer over white and black standard background, as well as over A2 and B1 simulated dental substrates. Translucency of all specimens and the shade matching of the pairs over the A2 and B1 substrates (ΔE*00 ) were calculated by Translucency Parameter and CIEDE2000 methods. Data were statistically analyzed by 95% confidence interval. RESULTS Porcelain veneer E1.0 groups were the most translucent, while the pairs veneer + luting agent WO showed the lowest translucency, and A1, A2, B1, and IL yielded little to no differences in translucency of the pairs. The overall best shade matching with A2 substrate was observed for D1.0 veneer + WO luting agent. CONCLUSION The opacity of the porcelain veneer paired with luting agents of different shades affected the final appearance of the restorations over distinct simulated tooth substrates. CLINICAL SIGNIFICANCE Distinct shades of flowable resin composites used as luting agent might yield clinically visible color differences on porcelain veneers facilitating an excellent shade match with adjacent teeth. (J Esthet Restor Dent 28:295-303, 2016).
Biomedical Materials | 2015
Adauê S. Oliveira; Marina R. Kaizer; Marina Sousa Azevedo; Fabrício Aulo Ogliari; Maximiliano Sérgio Cenci; Rafael R. Moraes
This study was designed to apply (super)hydrophobic crosslinked coatings by means of a sol-gel process on the surface of orthodontic devices and investigate the potential effect of these coatings in reducing the early retention of oral biofilm. Two organosilane-based hydrophobic solutions (HSs) were prepared containing hexadecyltrimethoxysilane diluted in ethanol (HS1) or 1H, 1H, 2H, 2H-perfluorodecyltriethoxysilane diluted in dimethyl sulfoxide (HS2). Stainless steel plates and ceramic discs were coated with HS1 or HS2 and heated at 150 °C for 2 h for condensation of a crosslinked SiO x network. Organosilane coatings were applied after previous, or no, surface sandblasting. Commercial stainless steel and ceramic brackets were used to evaluate oral biofilm retention after 12 h or 24 h of biofilm growth, using a microcosm model with human saliva as the inoculum. Surface roughness analysis (Ra, μm) indicated that sandblasting associated with organosilane coatings increased roughness for stainless steel brackets only. Analysis of the water contact angle showed that the stainless steel surface treated with HS1 was hydrophobic (~123°), while the ceramic surface treated with HS2 was superhydrophobic (~155°). Biofilm retention after 24 h was significantly lower in groups treated with hydrophobic coatings. An exponential reduction in biofilm accumulation was associated with increased water contact angle for both stainless steel and ceramic at 24 h. Application of (super)hydrophobic coatings on the surface of stainless steel and ceramic orthodontic devices might reduce the retention of oral biofilm.
Journal of Esthetic and Restorative Dentistry | 2017
Maristela Lago; Lisandra R. Mozzaquatro; Camila da Silva Rodrigues; Marina R. Kaizer; André Mallmann; Letícia Borges Jacques
OBJECTIVES Evaluate the influence of two bleaching agents (16% carbamide peroxide-CP and 35% hydrogen peroxide-HP) on color and translucency of one resin composite (Filtek Z350 XT) in two opacities (enamel and dentin) previously aged in deionized water or red wine. METHODS Sixty specimens of each material were divided in two groups (n = 30): aged in water or red wine for 14 days. Then the specimens were divided in three subgroups (n = 10): control/no treatment, treated with 16% carbamide peroxide (Mix Night), treated with 35% hydrogen peroxide (Mix One). Color readings were performed 24 hours after polishing (baseline); after the 14 days of aging; and after bleaching treatment. Color coordinates CIE L*a*b* were measured using a spectrophotometer (SP60 X-Rite). Color change (CIEDE2000) and translucency parameter were calculated. Data were analyzed with repeated measures two-way ANOVA, and Student-Newman-Keuls tests (5%). RESULTS Bleaching decreased color change in stained resin composites (aged in red wine), whereas increased it in non-stained enamel resin composites (aged in water). CP had better bleaching results with stained resin composites than HP. Translucency of non-stained dentin resin composite decreased with aging, but did not change with bleaching. For stained resin composites, aging caused reduced translucency, whereas bleaching increased it. CLINICAL SIGNIFICANCE Effective bleaching of discolored resin composites aged in an acidic and alcoholic media rich in staining agents was achieved, improving color and translucency. Carbamide peroxide showed better performance than hydrogen peroxide for the bleaching of stained resin composites. (J Esthet Restor Dent 29:368-377, 2017).