Radiology | 2008

Dual-Source CT: Effect of Heart Rate, Heart Rate Variability, and Calcification on Image Quality and Diagnostic Accuracy

Harald Brodoefel; Christof Burgstahler; Ilias Tsiflikas; Anja Reimann; Stephen Schroeder; Claus D. Claussen; Martin Heuschmid; Andreas F. Kopp

PURPOSE To prospectively evaluate the effect of heart rate, heart rate variability, and calcification on dual-source computed tomography (CT) image quality and to prospectively assess diagnostic accuracy of dual-source CT for coronary artery stenosis, by using invasive coronary angiography as the reference standard. MATERIALS AND METHODS This study had local Ethics Committee approval; all patients gave informed consent. Patients who underwent bypass surgery were excluded; patients with coronary artery stent-grafts were included. One hundred patients (20 women, 80 men; mean age, 62 years +/- 10 [standard deviation]) known to have or suspected of having coronary artery disease underwent dual-source CT and invasive coronary angiography. Image quality was assessed. Accuracy of dual-source CT in depiction or exclusion of significant stenosis (>or=50%) was evaluated on a per-segment and per-patient basis. Effects of heart rate, heart rate variability, and calcification on image quality and accuracy were analyzed by using multivariate regression and were analyzed between subgroups of predictor variables. Simple regression was performed to calculate thresholds for adequate image quality. RESULTS Mean heart rate was 64.9 beats per minute +/- 13.2, mean variability was 23.6 beats per CT examination +/- 36.2, and mean Agatston score was 786.5 +/- 965.9. Diagnostic image quality was obtained in 90.2% of segments. Sensitivity, specificity, and positive and negative predictive values for the presence of significant stenosis were, respectively, 91.1%, 92.0%, 75.4%, and 97.5% by segment and 100%, 81.5%, 93.6%, and 100% by patient. Image quality was significantly related to heart rate variability (P = .015) and calcification (P < .001); the number of nondiagnostic segments was significantly affected by calcification only. Calcification was the single factor with significant impact on diagnostic accuracy (P = .001). CONCLUSION While dual-source CT resulted in heart-rate independent image quality, image quality remained prone to heart rate variability and calcification.


Journal of Computer Assisted Tomography | 2004

Reliability of differentiating human coronary plaque morphology using contrast-enhanced multislice spiral computed tomography : A comparison with histology

Stephen Schroeder; Axel Kuettner; Martin Alexander Leitritz; Jan Janzen; Andreas F. Kopp; Christian Herdeg; Martin Heuschmid; Christof Burgstahler; Andreas Baumbach; Manfred Wehrmann; Claus D. Claussen

Background: Initial clinical results indicate that multislice spiral computed tomography (MDCT) might be useful for the noninvasive characterization of human coronary plaque morphology by determining tissue density within the lesions. This seems to be of clinical relevance, because coronary artery disease might be detected at an early stage before calcifications occur and noncalcified plaques that may be more likely to rupture could also be visualized noninvasively. The aim of the present study was to evaluate the reliability of contrast-enhanced MDCT in differentiating human atherosclerotic coronary plaque morphology by comparing it with the histopathologic gold standard. Methods and Results: Twelve human hearts were scanned postmortem using an MDCT (Somatom Volume Zoom; Siemens, Forchheim, Germany) high-resolution computed tomography scanner to detect atherosclerotic coronary plaques. Density measurements were performed within detected plaque areas. The exact location of each plaque was marked at the surface of the heart to assure accurate histopathologic sectioning of these lesions. The plaques were classified according to a modified Stary classification. Seventeen plaques were identified by MDCT. Six plaques were histopathologically classified as lipid rich (Stary III/IV), 6 plaques as intermediate (Stary V), and 5 plaques as calcific (Stary VII). Lipid-rich plaques had a mean density on MDCT of 42 ± 22 Hounsfield units (HU), intermediate plaques had a mean density of 70 ± 21 HU, and calcific plaques had a mean density of 715 ± 328 HU. ANOVA analysis revealed a significant difference in plaque density between the 3 groups (P < 0.0001). Conclusions: The comparison with histopathology confirms that tissue density as determined by contrast-enhanced MDCT might be used to differentiate atherosclerotic plaque morphology.


Investigative Radiology | 2007

Influence of a lipid-lowering therapy on calcified and noncalcified coronary plaques monitored by multislice detector computed tomography: results of the New Age II Pilot Study.

Christof Burgstahler; Anja Reimann; Torsten Beck; Axel Kuettner; Dorothee Baumann; Martin Heuschmid; Harald Brodoefel; Claus D. Claussen; Andreas F. Kopp; Stephen Schroeder

Purpose:Multislice detector computed tomography (MSCT) is an accurate noninvasive modality to detect and classify different stages of atherosclerosis. The aim of the New Age II Study was to detect coronary lesions in men without established coronary artery disease (CAD) but with a distinct cardiovascular risk profile. We also sought to assess the effect after 1 year of a lipid-lowering therapy (LLT) using 20 mg of atorvastatin. Methods:Forty-sixe male patients (mean, 61 ± 10 years) with an elevated risk for CAD (PROCAM score >3 quintile) without LLT were included. Native and contrast-enhanced scans were performed in all patients. A total of 27 of 46 patients received a follow-up scan (after 488 ± 138 days). Coronary plaque burden (CPB) was assessed volumetrically. Results:The prevalence of CAD was 83% (38/46 patients), and 11% (5/46) without coronary calcifications still had noncalcified plaques. Total cholesterol and low-density lipoprotein cholesterol levels decreased significantly under LLT (225 ± 41 mg/dL vs. 162 ± 37 mg/dL, P < 0.0001 and 148 ± 7 mg/dL vs. 88 ± 5 mg/dL, P < 0.001, respectively). On follow-up, calcium score and CPB remained unchanged (Agatston score: 261 ± 301 vs. 282 ± 360; CPB: 0.149 ± 0.108 vs. 0.128 ± 0.075 mL, P > 0.05), whereas mean plaque volume of noncalcified plaques decreased significantly from 0.042 ± 0.029 mL versus 0.030 ± 0.014 mL (P < 0.05, mean reduction 0.012 ± 0.017 mL or 24 ± 13%). Conclusions:Statin therapy led to a significant reduction of noncalcified plaque burden that was not reflected in calcium scoring or total plaque burden. This finding might explain the risk reduction after the initiation of statin therapy. Using multislice detector computed tomography, physicians have the potential to monitor medical treatment in patients with coronary atherosclerosis.


Heart | 2005

Image quality and diagnostic accuracy of non-invasive coronary imaging with 16 detector slice spiral computed tomography with 188 ms temporal resolution

Axel Kuettner; Torsten Beck; Tanja Drosch; Klaus Kettering; Martin Heuschmid; Christof Burgstahler; Claus D. Claussen; Andreas F. Kopp; Stephen Schroeder

Objective: To evaluate image quality and clinical accuracy in detecting coronary artery lesions with a new multidetector spiral computed tomography (MDCT) generation with 16 detector slices and a temporal resolution of 188 ms. Methods: 124 consecutive patients scheduled for invasive coronary angiography (ICA) were additionally studied by MDCT (Sensation 16 Speed 4D). MDCTs were analysed with regard to image quality and presence of coronary artery lesions. The results were compared with ICA. Results: 120 of 124 scans were successful. The image quality of all remaining 120 scans was sufficient (mean (SD) heart rate 64.2 (9.8) beats/min, range 43–95). The mean calcium mass was 167 (223) mg (range 0–1038). Thirteen coronary segments were evaluated for each patient (1560 segments in total). Image quality was graded as follows: excellent, 422 (27.1%) segments; good, 540 (34.6%) segments; moderate, 277 (17.7%) segments; heavily calcified, 215 (13.8%) segments; and blurred, 106 (6.8%) segments. ICA detected 359 lesions with a diameter stenosis > 50% and MDCT detected 304 of 359 (85%). Sensitivity, specificity, and positive and negative predictive values were 85%, 98%, 91%, and 96%, respectively. The correct clinical diagnosis (presence or absence of at least one stenosis > 50%) was obtained for 110 of 120 (92%) patients. Conclusions: MDCT image quality can be further improved with 16 slices and faster gantry rotation time. These results in an unselected population underline the potential of MDCT to become a non-invasive diagnostic alternative, especially for the exclusion of coronary artery disease, in the near future.


Investigative Radiology | 2007

Dual-source computed tomography: advances of improved temporal resolution in coronary plaque imaging.

Anja Reimann; Daniel Rinck; Ayser Birinci-Aydogan; Michael Scheuering; Christof Burgstahler; Stephen Schroeder; Harald Brodoefel; Ilias Tsiflikas; Tina Herberts; Thomas Flohr; Claus D. Claussen; Andreas F. Kopp; Martin Heuschmid

Objectives:The aim of this study was to quantify image quality gains of a moving coronary plaque phantom using dual-source computed tomography (DSCT) providing 83 milliseconds temporal resolution in direct comparison to 64 slice single-source multidetector CT (MDCT) with a temporal resolution of 165 milliseconds. Materials and Methods:Three cardiac vessel phantoms with fixed 50% stenosis and changing plaque configurations were mounted on a moving device simulating cardiac motion. Scans were performed at a simulated heart frequency of 60 to 120 bpm. Image quality assessment was performed in different anatomic orientations inside a thoracic phantom. Results:A significant improvement of image quality using the DSCT could be found (P = 0.0002). Relevant factors influencing image quality aside from frequency (P = 0.0002) are plaque composition (P < 0.0001), as well as orientation (P < 0.0001). Conclusion:Scanning with 83 milliseconds temporal resolution improved image quality of coronary plaque at higher heart frequencies.


American Journal of Roentgenology | 2007

Dual-Source CT with Improved Temporal Resolution in Assessment of Left Ventricular Function: A Pilot Study

Harald Brodoefel; Ulrich Kramer; Anja Reimann; Christof Burgstahler; Stephen Schroeder; Andreas F. Kopp; Martin Heuschmid

OBJECTIVE Functional analysis using MDCT has been limited by insufficient temporal resolution. The aim of this study was to assess the performance of a dual-source CT system with improved temporal resolution in the determination of both volume- or time-dependent functional parameters and regional wall motion in comparison with cine MRI. SUBJECTS AND METHODS Twenty patients (15 of whom had previous myocardial infarction) were prospectively examined using dual-source CT. MRI was used as the standard of reference. Using the Simpsons method, ventricular volumes were determined for the whole of the cardiac cycle and results compared using Parsons correlation and Bland-Altman analysis. Regional wall motion was assessed on cine images and compared using weighted kappa statistics. RESULTS Dual-source CT revealed a strong correlation with cine MRI regarding the quantification of end-diastolic volume (r = 0.98), end-systolic volume (r = 0.99), stroke volume (r = 0.96), and ejection fraction (r = 0.95). Good correlation was obtained for peak ejection rate (r = 0.79) and peak filling rate (r = 0.84), whereas agreement proved only moderate for time-to-peak ejection rate (r = 0.68) or time-to-peak filling rate from end-systole (r = 0.64). The mean difference for ejection fraction was negligible (bias, 0.72%). Good agreement between both techniques was likewise found for regional wall motion (kappa = 0.88). CONCLUSION With the improvement of temporal resolution between 42 and 83 milliseconds, dual-source CT not only enables accurate assessment of global functional parameters, but it also allows for quantification of time-dependent variables and reliable evaluation of regional wall motion.


Radiology | 2010

Urinary calculi composed of uric acid, cystine, and mineral salts: Differentiation with dual-energy CT at a radiation dose comparable to that of intravenous pyelography

Christoph Thomas; Martin Heuschmid; David Schilling; Dominik Ketelsen; Ilias Tsiflikas; A. Stenzl; Claus D. Claussen; Heinz Peter Schlemmer

PURPOSE To retrospectively evaluate radiation dose, image quality, and the ability to differentiate urinary calculi of differing compositions by using low-dose dual-energy computed tomography (CT). MATERIALS AND METHODS The institutional review board approved this retrospective study; informed consent was waived. A low-dose dual-energy CT protocol (tube voltage and reference effective tube current-time product, 140 kV and 23 mAs and 80 kV and 105 mAs; collimation, 64 × 0.6 mm; pitch, 0.7) for the detection of urinary calculi was implemented into routine clinical care. All patients (n = 112) who were examined with this protocol from July 2008 to August 2009 were included. The composition of urinary calculi was assessed by using commercially available postprocessing software and was compared with results of the reference standard (ex vivo infrared spectroscopy) in 40 patients for whom the reference standard was available. Effective doses were calculated. Image quality was rated subjectively and objectively and was correlated with patient size expressed as body cross-sectional area at the level of acquisition by using Spearman correlation coefficients. RESULTS One calcified concrement in the distal ureter of an obese patient was mistakenly interpreted as mixed calcified and uric acid. One struvite calculus was falsely interpreted as cystine. All other uric acid, cystine, and calcium-containing calculi were correctly identified by using dual-energy CT. The mean radiation dose was 2.7 mSv. The average image quality was rated as acceptable, with a decrease in image quality in larger patients. CONCLUSION Low-dose unenhanced dual-source dual-energy CT can help differentiate between calcified, uric acid, and cystine calculi at a radiation dose comparable to that of conventional intravenous pyelography. Because of decreased image quality in obese patients, only nonobese patients should be examined with this protocol.


British Journal of Radiology | 2009

Accuracy of dual-source CT in the characterisation of non-calcified plaque: use of a colour-coded analysis compared with virtual histology intravascular ultrasound.

Harald Brodoefel; C. Burgstahler; Martin Heuschmid; A. Reimann; Faisal Khosa; Andreas F. Kopp; Stephen Schroeder; Claus D. Claussen; Melvin E. Clouse

Non-invasive assessment of plaque volume and composition is important for risk stratification and long-term studies of plaque stabilisation. Our aim was to evaluate dual-source computed tomography (DSCT) and colour-coded analysis in the quantification and classification of coronary atheroma. DSCT and virtual histology intravascular ultrasound (IVUS-VH) were prospectively performed in 14 patients. 22 lesions were compared in terms of plaque volume, maximal per cent vessel stenosis and percentages of fatty, fibrous or calcified components. Plaque characterisation was performed with software that automatically segments luminal or outer vessel boundaries and uses CT attenuation for a colour-coded plaque analysis. Good correlation was found for per cent vessel stenosis in DSCT (53+/-13%) and IVUS (51+/-14%; r(2) = 0.70). Mean volumes for entire plaque and non-calcified atheroma were 68.5+/-33 mm(3) and 56.7+/-30 mm(3), respectively, in DSCT and 60.8+/-29 mm(3) and 55.8+/-26 mm(3), respectively, in IVUS. Mean percentages of fatty, fibrous or calcified components were 28.2+/-6%, 53.2+/-9% and 18.7+/-13%, respectively, in DSCT and 29.9+/-5%, 55.3+/-12% and 14.4+/-9%, respectively, in IVUS-VH. Significant overestimation was present for the entire plaque and the volume of calcified plaque (p = 0.03; p = 0.0004). Although good correlation with IVUS was obtained for the entire plaque (r(2) = 0.76) and non-calcified plaque volume (r(2) = 0.84), correlation proved very poor and insignificant for percentage plaque composition. Interclass correlation coefficients for non-calcified plaque volume and percentages of fatty, fibrous or calcified components were 0.99, 0.99, 0.95 and 0.98, respectively, and intraclass coefficients were 0.98, 0.93, 0.98 and 0.99, respectively. We found that using Hounsfield unit-based analysis, DSCT allows for accurate quantification of non-calcified plaque. Although percentage plaque composition proves highly reproducible, it is not correlated with IVUS-VH.


Heart | 2004

Non-invasive evaluation of atherosclerosis with contrast enhanced 16 slice spiral computed tomography: results of ex vivo investigations

Stephen Schroeder; Axel Kuettner; T Wojak; J Janzen; Martin Heuschmid; T Athanasiou; Torsten Beck; Christof Burgstahler; Christian Herdeg; Claus D. Claussen; Andreas F. Kopp

Objective: To evaluate the diagnostic accuracy of 16 slice computed tomography (CT) in determining plaque morphology and composition in an experimental setting. The results were compared with histopathological analysis as the reference standard. Methods: Nine human popliteal arteries derived from amputations because of atherosclerotic disease were investigated with multislice spiral CT (MSCT). Atherosclerotic lesions were morphologically classified (completely or partially occlusive, concentric, eccentric), and tissue densities were determined within these plaques. In addition, vessel dimensions were quantitatively measured. Results: The results were compared with histological analysis. The concordance index κ for morphological classification was 0.88. Plaque density (n  =  51 lesions) was significantly different (p < 0.0001) between lipid rich, fibrotic, and calcified lesions (Stary stage III: n  =  2, 58 (8) Hounsfield units (HU); Stary V: n  =  11, 50 (21) HU; Stary VI: n  =  14, 96 (42) HU; Stary VII: n  =  6, 858 (263) HU; Stary VIII: n  =  18, 126 (99) HU). The concordance index κ for the classification of plaques based on density was 0.51. Vessel dimensions had a good correlation (r  =  0.98). Conclusions: 16 slice CT was found to be a reliable non-invasive imaging technique for assessing atherosclerotic plaque morphology and composition. Although calcified lesions can be differentiated from non-calcified lesions, the diagnostic accuracy in further subclassifying non-calcified plaques as lipid rich and fibrotic is low, even under experimental conditions.


Investigative Radiology | 2010

Differentiation of urinary calculi with dual energy CT: effect of spectral shaping by high energy tin filtration.

Christoph Thomas; Bernhard Krauss; Dominik Ketelsen; Ilias Tsiflikas; A. Reimann; Matthias K. Werner; David Schilling; Jörg Hennenlotter; Claus D. Claussen; Heinz Peter Schlemmer; Martin Heuschmid

Objectives:In dual energy (DE) computed tomography (CT), spectral shaping by additional filtration of the high energy spectrum can theoretically improve dual energy contrast. The aim of this in vitro study was to examine the influence of an additional tin filter for the differentiation of human urinary calculi by dual energy CT. Materials and Methods:A total of 36 pure human urinary calculi (uric acid, cystine, calciumoxalate monohydrate, calciumoxalate dihydrate, carbonatapatite, brushite, average diameter 10.5 mm) were placed in a phantom and imaged with 2 dual source CT scanners. One scanner was equipped with an additional tin (Sn) filter. Different combinations of tube voltages (140/80 kV, 140/100 kV, Sn140/100 kV, Sn140/80 kV, with Sn140 referring to 140 kV with the tin filter) were applied. Tube currents were adapted to yield comparable dose indices. Low- and high energy images were reconstructed. The calculi were segmented semiautomatically in the datasets and DE ratios (attenuation@low_kV/attenuation@high_kV) and were calculated for each calculus. DE contrasts (DE-ratio_material1/DE-ratio_material2) were computed for uric acid, cystine and calcified calculi and compared between the combinations of tube voltages. Results:Using exclusively DE ratios, all uric acid, cystine and calcified calculi (as a group) could be differentiated in all protocols; the calcified calculi could not be differentiated among each other in any examination protocol. The highest DE ratios and DE contrasts were measured for the Sn140/80 protocol (53%–62% higher DE contrast than in the 140/80 kV protocol without additional filtration). The DE ratios and DE contrasts of the 80/140 kV and 100/Sn140 kV protocols were comparable. Conclusion:Uric acid, cystine and calcified calculi could be reliably differentiated by any of the protocols. A dose-neutral gain of DE contrast was found in the Sn-filter protocols, which might improve the differentiation of smaller calculi (Sn140/80 kV) and improve image quality and calculi differentiation in larger patients (Sn140/100 kV). However, even with the improved spectral separation of the Sn-filter protocols, the DE ratios of calcified calculi are not sufficiently distinct to allow a differentiation within this group.

Collaboration


Dive into the Martin Heuschmid's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Harald Brodoefel

Beth Israel Deaconess Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Anja Reimann

University of California

View shared research outputs
Researchain Logo
Decentralizing Knowledge