Martin Krenkel
University of Göttingen
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Martin Krenkel.
Scientific Reports | 2015
Martin Krenkel; Andrea Markus; Matthias Bartels; Christian Dullin; Frauke Alves; Tim Salditt
We have performed x-ray phase-contrast tomography on mouse lung tissue. Using a divergent x-ray beam generated by nanoscale focusing, we used zoom tomography to produce three-dimensional reconstructions with selectable magnification, resolution, and field of view. Thus, macroscopic tissue samples extending over several mm can be studied in sub-cellular-level structural detail. The zoom capability and, in particular, the high dose efficiency are enabled by the near-perfect exit wavefront of an optimized x-ray waveguide channel. In combination with suitable phase-retrieval algorithms, challenging radiation-sensitive and low-contrast samples can be reconstructed with minimal artefacts. The dose efficiency of the method is demonstrated by the reconstruction of living macrophages both with and without phagocytized contrast agents. We also used zoom tomography to visualize barium-labelled macrophages in the context of morphological structures in asthmatic and healthy mouse lung tissue one day after intratracheal application. The three-dimensional reconstructions showed that the macrophages predominantly localized to the alveoli, but they were also found in bronchial walls, indicating that these cells might be able to migrate from the lumen of the bronchi through the epithelium.
Applied Physics Letters | 2013
Matthias Bartels; Victor H. Hernandez; Martin Krenkel; Tobias Moser; Tim Salditt
We present phase contrast x-ray tomography of functional soft tissue within the bony cochlear capsule of mice, carried out at laboratory microfocus sources with well-matched source, detector, geometry, and reconstruction algorithms at spatial resolutions down to 2 μm. Contrast, data quality and resolution enable the visualization of thin membranes and nerve fibers as well as automated segmentation of surrounding bone. By complementing synchrotron radiation imaging techniques, a broad range of biomedical applications becomes possible as demonstrated for optogenetic cochlear implant research.
Journal of Synchrotron Radiation | 2015
Tim Salditt; Markus Osterhoff; Martin Krenkel; Robin N. Wilke; Marius Priebe; Matthias Bartels; Sebastian Kalbfleisch; Michael Sprung
A compound optical system for coherent focusing and imaging at the nanoscale is reported, realised by high-gain fixed-curvature elliptical mirrors in combination with X-ray waveguide optics or different cleaning apertures. The key optical concepts are illustrated, as implemented at the Göttingen Instrument for Nano-Imaging with X-rays (GINIX), installed at the P10 coherence beamline of the PETRA III storage ring at DESY, Hamburg, and examples for typical applications in biological imaging are given. Characteristic beam configurations with the recently achieved values are also described, meeting the different requirements of the applications, such as spot size, coherence or bandwidth. The emphasis of this work is on the different beam shaping, filtering and characterization methods.
Optics Express | 2013
Martin Krenkel; Matthias Bartels; Tim Salditt
We have implemented a deterministic method for solving the phase problem in hard x-ray in-line holography which overcomes the twin image problem. The phase distribution in the detector plane is retrieved by using two images with slightly different Fresnel numbers. We then use measured intensities and reconstructed phases in the detection plane to compute the exit wave in the sample plane. No further a priori information like a limited support or the assumption of pure phase objects is necessary so that it can be used for a wide range of complex samples. Using a nano-focused hard x-ray beam half period resolutions better than 30 nm are achieved.
Journal of Synchrotron Radiation | 2015
Christian Dullin; Simeone Dal Monego; Emanuel Larsson; Sara Mohammadi; Martin Krenkel; Chiara Garrovo; Stefania Biffi; Andrea Lorenzon; Andrea Markus; Joanna Napp; Tim Salditt; Agostino Accardo; Frauke Alves; Giuliana Tromba
This study presents an approach to increase the sensitivity of lung computed tomography (CT) imaging by utilizing in-line phase contrast CT in combination with single-distance phase-retrieval algorithms and a dedicated image-processing regime. As demonstrated here, functional CT imaging can be achieved for the assessment of both structural alterations in asthmatic mouse lung tissue and the accumulation pattern of instilled barium-sulfate-labelled macrophages in comparison with healthy controls.
Scientific Reports | 2017
Mareike Töpperwien; Martin Krenkel; Daniel Vincenz; Franziska Stöber; Anja M. Oelschlegel; Jürgen Goldschmidt; Tim Salditt
Studies of brain cytoarchitecture in mammals are routinely performed by serial sectioning of the specimen and staining of the sections. The procedure is labor-intensive and the 3D architecture can only be determined after aligning individual 2D sections, leading to a reconstructed volume with non-isotropic resolution. Propagation-based x-ray phase-contrast tomography offers a unique potential for high-resolution 3D imaging of intact biological specimen due to the high penetration depth and potential resolution. We here show that even compact laboratory CT at an optimized liquid-metal jet microfocus source combined with suitable phase-retrieval algorithms and a novel tissue preparation can provide cellular and subcellular resolution in millimeter sized samples of mouse brain. We removed water and lipids from entire mouse brains and measured the remaining dry tissue matrix in air, lowering absorption but increasing phase contrast. We present single-cell resolution images of mouse brain cytoarchitecture and show that axons can be revealed in myelinated fiber bundles. In contrast to optical 3D techniques our approach does neither require staining of cells nor tissue clearing, procedures that are increasingly difficult to apply with increasing sample and brain sizes. The approach thus opens a novel route for high-resolution high-throughput studies of brain architecture in mammals.
Physics in Medicine and Biology | 2012
Christian Olendrowitz; Matthias Bartels; Martin Krenkel; André Beerlink; R Mokso; Michael Sprung; Tim Salditt
We have analyzed the model organism Caenorhabditis elegans with the help of phase-contrast x-ray tomography. This work combines techniques from x-ray imaging studies of single biological cells by in-line holography with three-dimensional reconstruction and furthermore extends these studies to the multicellular level. To preserve the sub-cellular ultrastructure of the nematodes, we used the near-native sample preparation of high-pressure freezing as commonly used in the field of electron microscopy. For the presented samples, a standard, non-magnifying parallel-beam setting, as well as a magnifying, divergent-beam setting using nanofocusing optics is evaluated based on their tomographic reconstruction potential. In this paper, we address difficulties in sample preparation and issues of image processing. By experimental refinement and through optimized reconstruction procedures, we were able to perform x-ray imaging studies on a living specimen.
Journal of Structural Biology | 2015
Matthias Bartels; Martin Krenkel; Peter Cloetens; Wiebke Möbius; Tim Salditt
We have used X-ray phase contrast tomography to resolve the structure of uncut, entire myelinated optic, saphenous and sciatic mouse nerves. Intrinsic electron density contrast suffices to identify axonal structures. Specific myelin labeling by an osmium tetroxide stain enables distinction between axon and surrounding myelin sheath. Utilization of spherical wave illumination enables zooming capabilities which enable imaging of entire sciatic internodes as well as identification of sub-structures such as nodes of Ranvier and Schmidt-Lanterman incisures.
Journal of Applied Crystallography | 2015
Robin N. Wilke; Michael Hoppert; Martin Krenkel; M. Bartels; Tim Salditt
Quantitative X-ray phase contrast imaging uniquely offers quantitative imaging information in terms of electron density maps allowing for mass and mass density determinations of soft biological samples (‘weighing with light’). Here, it was carried out using coherent X-ray waveguide illumination, yielding values of the mass and mass density of freeze-dried bacterial endospores (Bacillus spp.).
Optics Express | 2016
Simon Maretzke; Matthias Bartels; Martin Krenkel; Tim Salditt; Thorsten Hohage
Like many other advanced imaging methods, x-ray phase contrast imaging and tomography require mathematical inversion of the observed data to obtain real-space information. While an accurate forward model describing the generally nonlinear image formation from a given object to the observations is often available, explicit inversion formulas are typically not known. Moreover, the measured data might be insufficient for stable image reconstruction, in which case it has to be complemented by suitable a priori information. In this work, regularized Newton methods are presented as a general framework for the solution of such ill-posed nonlinear imaging problems. For a proof of principle, the approach is applied to x-ray phase contrast imaging in the near-field propagation regime. Simultaneous recovery of the phase- and amplitude from a single near-field diffraction pattern without homogeneity constraints is demonstrated for the first time. The presented methods further permit all-at-once phase contrast tomography, i.e. simultaneous phase retrieval and tomographic inversion. We demonstrate the potential of this approach by three-dimensional imaging of a colloidal crystal at 95nm isotropic resolution.