Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Martin Reiss-Zimmermann is active.

Publication


Featured researches published by Martin Reiss-Zimmermann.


NeuroImage | 2014

Multisite longitudinal reliability of tract-based spatial statistics in diffusion tensor imaging of healthy elderly subjects

Jorge Jovicich; Moira Marizzoni; Beatriz Bosch; David Bartrés-Faz; Jennifer Arnold; Jens Benninghoff; Jens Wiltfang; Luca Roccatagliata; Agnese Picco; Flavio Nobili; Olivier Blin; Stéphanie Bombois; Renaud Lopes; Régis Bordet; Valérie Chanoine; Jean-Philippe Ranjeva; Mira Didic; Hélène Gros-Dagnac; Pierre Payoux; Giada Zoccatelli; Franco Alessandrini; Alberto Beltramello; Nuria Bargalló; Antonio Ferretti; Massimo Caulo; Marco Aiello; Monica Ragucci; Andrea Soricelli; Nicola Salvadori; Roberto Tarducci

Large-scale longitudinal neuroimaging studies with diffusion imaging techniques are necessary to test and validate models of white matter neurophysiological processes that change in time, both in healthy and diseased brains. The predictive power of such longitudinal models will always be limited by the reproducibility of repeated measures acquired during different sessions. At present, there is limited quantitative knowledge about the across-session reproducibility of standard diffusion metrics in 3T multi-centric studies on subjects in stable conditions, in particular when using tract based spatial statistics and with elderly people. In this study we implemented a multi-site brain diffusion protocol in 10 clinical 3T MRI sites distributed across 4 countries in Europe (Italy, Germany, France and Greece) using vendor provided sequences from Siemens (Allegra, Trio Tim, Verio, Skyra, Biograph mMR), Philips (Achieva) and GE (HDxt) scanners. We acquired DTI data (2 × 2 × 2 mm(3), b = 700 s/mm(2), 5 b0 and 30 diffusion weighted volumes) of a group of healthy stable elderly subjects (5 subjects per site) in two separate sessions at least a week apart. For each subject and session four scalar diffusion metrics were considered: fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD) and axial (AD) diffusivity. The diffusion metrics from multiple subjects and sessions at each site were aligned to their common white matter skeleton using tract-based spatial statistics. The reproducibility at each MRI site was examined by looking at group averages of absolute changes relative to the mean (%) on various parameters: i) reproducibility of the signal-to-noise ratio (SNR) of the b0 images in centrum semiovale, ii) full brain test-retest differences of the diffusion metric maps on the white matter skeleton, iii) reproducibility of the diffusion metrics on atlas-based white matter ROIs on the white matter skeleton. Despite the differences of MRI scanner configurations across sites (vendors, models, RF coils and acquisition sequences) we found good and consistent test-retest reproducibility. White matter b0 SNR reproducibility was on average 7 ± 1% with no significant MRI site effects. Whole brain analysis resulted in no significant test-retest differences at any of the sites with any of the DTI metrics. The atlas-based ROI analysis showed that the mean reproducibility errors largely remained in the 2-4% range for FA and AD and 2-6% for MD and RD, averaged across ROIs. Our results show reproducibility values comparable to those reported in studies using a smaller number of MRI scanners, slightly different DTI protocols and mostly younger populations. We therefore show that the acquisition and analysis protocols used are appropriate for multi-site experimental scenarios.


PLOS ONE | 2014

High-Resolution Mechanical Imaging of Glioblastoma by Multifrequency Magnetic Resonance Elastography

Kaspar-Josche Streitberger; Martin Reiss-Zimmermann; Florian Baptist Freimann; Simon Bayerl; Jing Guo; Felix Arlt; Jens Wuerfel; Jürgen Braun; Karl-Titus Hoffmann; Ingolf Sack

Objective To generate high-resolution maps of the viscoelastic properties of human brain parenchyma for presurgical quantitative assessment in glioblastoma (GB). Methods Twenty-two GB patients underwent routine presurgical work-up supplemented by additional multifrequency magnetic resonance elastography. Two three-dimensional viscoelastic parameter maps, magnitude |G*|, and phase angle φ of the complex shear modulus were reconstructed by inversion of full wave field data in 2-mm isotropic resolution at seven harmonic drive frequencies ranging from 30 to 60 Hz. Results Mechanical brain maps confirmed that GB are composed of stiff and soft compartments, resulting in high intratumor heterogeneity. GB could be easily differentiated from healthy reference tissue by their reduced viscous behavior quantified by φ (0.37±0.08 vs. 0.58±0.07). |G*|, which in solids more relates to the materials stiffness, was significantly reduced in GB with a mean value of 1.32±0.26 kPa compared to 1.54±0.27 kPa in healthy tissue (P = 0.001). However, some GB (5 of 22) showed increased stiffness. Conclusion GB are generally less viscous and softer than healthy brain parenchyma. Unrelated to the morphology-based contrast of standard magnetic resonance imaging, elastography provides an entirely new neuroradiological marker and contrast related to the biomechanical properties of tumors.


Investigative Radiology | 2014

Seven-Tesla magnetic resonance imaging in Wilson disease using quantitative susceptibility mapping for measurement of copper accumulation

Dominik Fritzsch; Martin Reiss-Zimmermann; Robert Trampel; Robert Turner; Karl-Titus Hoffmann; Andreas Schäfer

ObjectivesIn Wilson disease (WD), the copper content of cerebral tissue is increased, particularly in the basal ganglia. This study investigated whether a change in magnetic susceptibility can be detected using quantitative susceptibility mapping of the brain in patients with WD compared with healthy controls. Materials and MethodsEleven patients with WD (6 with the neurological form, 5 with the hepatic form) and 10 age-matched healthy controls who gave informed consent were examined at 7 T in a whole-body scanner (MAGNETOM; Siemens Medical Solutions, Erlangen, Germany) using a 24-channel phased array coil (Nova Medical). For imaging, a 3-dimensional spoiled gradient multiecho sequence (repetition time, 40 milliseconds; echo time, 9.76/19.19/28.62 milliseconds; bandwidth, 150 hertz per pixel; voxel size, 0.6 × 0.6 × 0.8 mm) was used. The susceptibility of selected regions (substantia nigra, red nucleus, pallidum, putamen, caudate nucleus) was analyzed in susceptibility maps. ResultsThe patients with WD showed significantly increased susceptibility (P value, 0.001–0.05) in all analyzed regions compared with healthy controls. This was evident not only in patients with a neurological syndrome but also, with lower values, in patients with isolated hepatic manifestations. The distribution patterns of copper accumulation were different between the patients with neurological and non–neurological manifestations of the disease. ConclusionsIn neurologically symptomatic and asymptomatic patients with WD, we found increased magnetic susceptibility in the brain tissue using quantitative susceptibility mapping.


Journal of Neurosurgery | 2016

Idiopathic normal pressure hydrocephalus: diagnostic and predictive value of clinical testing, lumbar drainage, and CSF dynamics

Cynthia Vanessa Mahr; Markus Dengl; Ulf Nestler; Martin Reiss-Zimmermann; Gerrit Eichner; Matthias Preuß; Jürgen Meixensberger

OBJECTIVE The aim of the study was to analyze the diagnostic and predictive values of clinical tests, CSF dynamics, and intracranial pulsatility tests, compared with external lumbar drainage (ELD), for shunt response in patients with idiopathic normal pressure hydrocephalus (iNPH). METHODS Sixty-eight consecutive patients with suspected iNPH were prospectively evaluated. Preoperative assessment included clinical tests, overnight intracranial pressure (ICP) monitoring, lumbar infusion test (LIFT), and ELD for 24-72 hours. Simple and multiple linear regression analyses were conducted to identify predictive parameters concerning the outcome after shunt therapy. RESULTS Positive response to ELD correctly predicted improvement after CSF diversion in 87.9% of the patients. A Mini-Mental State Examination (MMSE) value below 21 was associated with nonresponse after shunt insertion (specificity 93%, sensitivity 67%). Resistance to outflow of CSF (ROut) > 12 mm Hg/ml/min was false negative in 21% of patients. Intracranial pulsatility parameters yielded different results in various parameters (correlation coefficient between pulse amplitude and ICP, slow wave amplitude, and mean ICP) but did not correlate to outcome. In multiple linear regression analysis, a calculation of presurgical MMSE versus the value after ELD, ROut, and ICP amplitude quotient during LIFT was significantly associated with outcome (p = 0.04). CONCLUSIONS Despite a multitude of invasive tests, presurgical clinical testing and response to ELD yielded the best prediction for improvement of symptoms following surgery. The complication rate of invasive testing was 5.4%. Multiple and simple linear regression analyses indicated that outcome can only be predicted by a combination of parameters, in accordance with a multifactorial pathogenesis of iNPH.


Scientific Reports | 2017

Impact of the use of an endorectal coil for 3 T prostate MRI on image quality and cancer detection rate

Josephin Gawlitza; Martin Reiss-Zimmermann; G Thörmer; Alexander Schaudinn; Nicolas Linder; Nikita Garnov; Lars-Christian Horn; Do Minh; Roman Ganzer; Jens-Uwe Stolzenburg; Thomas Kahn; Michael Moche; Harald Busse

This work aims to assess the impact of an additional endorectal coil on image quality and cancer detection rate within the same patients. At a single academic medical center, this transversal study included 41 men who underwent T2- and diffusion-weighted imaging at 3 T using surface coils only or in combination with an endorectal coil in the same session. Two blinded readers (A and B) randomly evaluated all image data in separate sessions. Image quality with respect to localization and staging was rated on a five-point scale. Lesions were classified according to their prostate imaging reporting and data system (PIRADS) score version 1. Standard of reference was provided by whole-mount step-section analysis. Mean image quality scores averaged over all localization-related items were significantly higher with additional endorectal coil for both readers (p < 0.001), corresponding staging-related items were only higher for reader B (p < 0.001). With an endorectal coil, the rate of correctly detecting cancer per patient was significantly higher for reader B (p < 0.001) but not for reader A (p = 0.219). The numbers of histologically confirmed tumor lesions were rather similar for both settings. The subjectively rated 3-T image quality was improved with an endorectal coil. In terms of diagnostic performance, the use of an additional endorectal coil was not superior.


Journal of Magnetic Resonance Imaging | 2013

Novel technique for MR elastography of the prostate using a modified standard endorectal coil as actuator.

G Thörmer; Martin Reiss-Zimmermann; J Otto; Karl-Titus Hoffmann; Michael Moche; Nikita Garnov; Thomas Kahn; Harald Busse

To present a novel method for MR elastography (MRE) of the prostate at 3 Tesla using a modified endorectal imaging coil.


Acta Radiologica | 2013

Improvement of SNR and acquisition acceleration using a 32-channel head coil compared to a 12-channel head coil at 3T.

Martin Reiss-Zimmermann; Marcel Gutberlet; Herbert Köstler; Dominik Fritzsch; Karl-Titus Hoffmann

Background Magnetic resonance imaging (MRI) techniques continue to improve in manifold ways. Besides field strength and sequence optimization, technical advances in coil design and sensitivity yield to increase the signal detection and therefore improve image quality. Purpose To evaluate the performance of signal-to-noise ratio (SNR) and parallel acquisition technique (PAT) acceleration of a dedicated 32-channel head coil compared with a standard 12-channel head coil. Material and Methods In a clinical 3T setting, spatial resolved SNR values for unaccelerated imaging and PAT with acceleration factors of 2–6 of a 32-channel head coil were evaluated in relation to a 12-channel head coil. SNR was determined quantitatively using proton-density-weighted in-vivo examinations in five healthy volunteers. Quantitative SNR maps for unaccelerated and PAT imaging were calculated using unfiltered MR raw data. Results Up to three-fold higher SNR values were achieved with the 32-channel head coil, which diminished towards the center to an increase of 40% compared with the 12-channel head coil. When using PAT, the 32-channel head coil resulted in a lower spatial-dependent quantitative noise enhancement, varying between 0% at R = 2 and 33% at R = 5. Conclusion The 32-channel head coil provided superior SNR both with and without PAT compared with a 12-channel head coil, especially close to the brain surface. Using PAT, the unavoidable noise enhancement is diminished up to acceleration factors of 6 for the 32-channel head coil. Therefore, the 32-channel head coil is considered as a preferable tool for high-resolution neuroradiological imaging.


Acta Radiologica | 2014

The influence of lumbar spinal drainage on diffusion parameters in patients with suspected normal pressure hydrocephalus using 3T MRI

Martin Reiss-Zimmermann; Michael Scheel; Markus Dengl; Matthias Preuß; Dominik Fritzsch; Karl-Titus Hoffmann

Background Normal pressure hydrocephalus (NPH) has been an ongoing and challenging field of research for the past decades because two main issues are still not fully understood: the pathophysiologic mechanisms underlying ventricular enlargement and prediction of outcome after surgery. Purpose To evaluate changes in diffusion tensor imaging (DTI) derived parameters in patients with suspected normal pressure hydrocephalus before and after withdrawal of cerebrospinal fluid (CSF). Material and Methods Twenty-four consecutive patients with clinical and radiological suspicion of NPH and 14 age-matched control subjects were examined with DTI on a clinical 3T scanner. Patients were examined before and 6–36 h after CSF drainage (interval between scans, 5 days). Fifteen patients were finally included in data analysis. Fractional anisotropy (FA) and mean, parallel, and radial diffusivity (MD, PD, RD) were evaluated using a combination of a ROI-based approach and a whole-brain voxel-by-voxel analysis. Results Alteration of DTI parameters in patients with suspected NPH is regionally different. Compared to the control group, we found an elevation of FA in the subcortical white matter (SCWM) and corpus callosum, whereas the other diffusion parameters showed an increase throughout the brain in variable extent. We also found a slight normalization of RD in the SCWM in patients after lumbar drainage. Conclusion Our results show that DWI parameters are regionally dependent and reflect multifactorial (patho-) physiological mechanisms, which need to be interpreted carefully. It seems that improvement of gait is caused by a decrease of interstitial water deposition in the SCWM.


European Radiology | 2012

Diagnostic value of ADC in patients with prostate cancer: influence of the choice of b values.

G Thörmer; J Otto; Martin Reiss-Zimmermann; Matthias Seiwerts; Michael Moche; Nikita Garnov; Toni Franz; Minh Do; Jens-Uwe Stolzenburg; Lars-Christian Horn; Thomas Kahn; Harald Busse


Clinical Neuroradiology-klinische Neuroradiologie | 2015

High Resolution Imaging of Viscoelastic Properties of Intracranial Tumours by Multi-Frequency Magnetic Resonance Elastography

Martin Reiss-Zimmermann; Kaspar-Josche Streitberger; Ingolf Sack; Juergen Braun; F. Arlt; D. Fritzsch; Karl-Titus Hoffmann

Collaboration


Dive into the Martin Reiss-Zimmermann's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge