Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Martin Ugander is active.

Publication


Featured researches published by Martin Ugander.


Journal of Cardiovascular Magnetic Resonance | 2013

Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement

James C. Moon; Daniel Messroghli; Peter Kellman; Stefan K Piechnik; Matthew D. Robson; Martin Ugander; Peter D. Gatehouse; Andrew E. Arai; Matthias G. Friedrich; Stefan Neubauer; Jeanette Schulz-Menger; Erik B. Schelbert

Rapid innovations in cardiovascular magnetic resonance (CMR) now permit the routine acquisition of quantitative measures of myocardial and blood T1 which are key tissue characteristics. These capabilities introduce a new frontier in cardiology, enabling the practitioner/investigator to quantify biologically important myocardial properties that otherwise can be difficult to ascertain clinically. CMR may be able to track biologically important changes in the myocardium by: a) native T1 that reflects myocardial disease involving the myocyte and interstitium without use of gadolinium based contrast agents (GBCA), or b) the extracellular volume fraction (ECV)–a direct GBCA-based measurement of the size of the extracellular space, reflecting interstitial disease. The latter technique attempts to dichotomize the myocardium into its cellular and interstitial components with estimates expressed as volume fractions. This document provides recommendations for clinical and research T1 and ECV measurement, based on published evidence when available and expert consensus when not. We address site preparation, scan type, scan planning and acquisition, quality control, visualisation and analysis, technical development. We also address controversies in the field. While ECV and native T1 mapping appear destined to affect clinical decision making, they lack multi-centre application and face significant challenges, which demand a community-wide approach among stakeholders. At present, ECV and native T1 mapping appear sufficiently robust for many diseases; yet more research is required before a large-scale application for clinical decision-making can be recommended.


BMC Medical Imaging | 2010

Design and validation of Segment - freely available software for cardiovascular image analysis

Einar Heiberg; Jane Sjögren; Martin Ugander; Marcus Carlsson; Henrik Engblom; Håkan Arheden

BackgroundCommercially available software for cardiovascular image analysis often has limited functionality and frequently lacks the careful validation that is required for clinical studies. We have already implemented a cardiovascular image analysis software package and released it as freeware for the research community. However, it was distributed as a stand-alone application and other researchers could not extend it by writing their own custom image analysis algorithms. We believe that the work required to make a clinically applicable prototype can be reduced by making the software extensible, so that researchers can develop their own modules or improvements. Such an initiative might then serve as a bridge between image analysis research and cardiovascular research. The aim of this article is therefore to present the design and validation of a cardiovascular image analysis software package (Segment) and to announce its release in a source code format.ResultsSegment can be used for image analysis in magnetic resonance imaging (MRI), computed tomography (CT), single photon emission computed tomography (SPECT) and positron emission tomography (PET). Some of its main features include loading of DICOM images from all major scanner vendors, simultaneous display of multiple image stacks and plane intersections, automated segmentation of the left ventricle, quantification of MRI flow, tools for manual and general object segmentation, quantitative regional wall motion analysis, myocardial viability analysis and image fusion tools. Here we present an overview of the validation results and validation procedures for the functionality of the software. We describe a technique to ensure continued accuracy and validity of the software by implementing and using a test script that tests the functionality of the software and validates the output. The software has been made freely available for research purposes in a source code format on the project home page http://segment.heiberg.se.ConclusionsSegment is a well-validated comprehensive software package for cardiovascular image analysis. It is freely available for research purposes provided that relevant original research publications related to the software are cited.


Jacc-cardiovascular Imaging | 2012

Myocardial Edema as Detected by Pre-Contrast T1 and T2 CMR Delineates Area at Risk Associated With Acute Myocardial Infarction

Martin Ugander; Paul S Bagi; Abiola J Oki; Billy T. Chen; Li-Yueh Hsu; Anthony H. Aletras; Saurabh Shah; Andreas Greiser; Peter Kellman; Andrew E. Arai

OBJECTIVES The aim of this study was to determine whether cardiac magnetic resonance (CMR) in vivo T1 mapping can measure myocardial area at risk (AAR) compared with microspheres or T2 mapping CMR. BACKGROUND If T2-weighted CMR is abnormal in the AAR due to edema related to myocardial ischemia, then T1-weighted CMR should also be able to detect and accurately quantify AAR. METHODS Dogs (n = 9) underwent a 2-h coronary occlusion followed by 4 h of reperfusion. CMR of the left ventricle was performed for mapping of T1 and T2 prior to any contrast administration. AAR was defined as regions that had a T1 or T2 value (ms) >2 SD from remote myocardium, and regions with microsphere blood flow (ml/min/g) during occlusion <2 SD from remote myocardium. Infarct size was determined by triphenyltetrazolium chloride staining. RESULTS The relaxation parameters T1 and T2 were increased in the AAR compared with remote myocardium (mean ± SD: T1, 1,133 ± 55 ms vs. 915 ± 33 ms; T2, 71 ± 6 ms vs. 49 ± 3 ms). On a slice-by-slice basis (n = 78 slices), AAR by T1 and T2 mapping correlated (R(2) = 0.95, p < 0.001) with good agreement (mean ± 2 SD: 0.4 ± 16.6% of slice). On a whole-heart analysis, T1 measurements of left ventricular mass, AAR, and myocardial salvage correlated to microsphere measures (R(2) = 0.94) with good agreement (mean ± 2 SD: -1.4 ± 11.2 g of myocardium). Corresponding T2 measurements of left ventricular mass, AAR, and salvage correlated to microsphere analysis (R(2) = 0.96; mean ± 2 SD: agreement 1.6 ± 9.2 g of myocardium). This yielded a median infarct size of 30% of the AAR (range 12% to 52% of AAR). CONCLUSIONS For determining AAR after acute myocardial infarction, noncontrast T1 mapping and T2 mapping sequences yield similar quantitative results, and both agree well with microspheres. The relaxation properties T1 and T2 both change in a way that is consistent with the presence of myocardial edema following myocardial ischemia/reperfusion.


Journal of Cardiovascular Magnetic Resonance | 2012

Extracellular volume fraction mapping in the myocardium, part 1: evaluation of an automated method

Peter Kellman; Joel R Wilson; Hui Xue; Martin Ugander; Andrew E. Arai

BackgroundDisturbances in the myocardial extracellular volume fraction (ECV), such as diffuse or focal myocardial fibrosis or edema, are hallmarks of heart disease. Diffuse ECV changes are difficult to assess or quantify with cardiovascular magnetic resonance (CMR) using conventional late gadolinium enhancement (LGE), or pre- or post-contrast T1-mapping alone. ECV measurement circumvents factors that confound T1-weighted images or T1-maps, and has been shown to correlate well with diffuse myocardial fibrosis. The goal of this study was to develop and evaluate an automated method for producing a pixel-wise map of ECV that would be adequately robust for clinical work flow.MethodsECV maps were automatically generated from T1-maps acquired pre- and post-contrast calibrated by blood hematocrit. The algorithm incorporates correction of respiratory motion that occurs due to insufficient breath-holding and due to misregistration between breath-holds, as well as automated identification of the blood pool. Images were visually scored on a 5-point scale from non-diagnostic (1) to excellent (5).ResultsThe quality score of ECV maps was 4.23 ± 0.83 (m ± SD), scored for n = 600 maps from 338 patients with 83% either excellent or good. Co-registration of the pre-and post-contrast images improved the image quality for ECV maps in 81% of the cases. ECV of normal myocardium was 25.4 ± 2.5% (m ± SD) using motion correction and co-registration values and was 31.5 ± 8.7% without motion correction and co-registration.ConclusionsFully automated motion correction and co-registration of breath-holds significantly improve the quality of ECV maps, thus making the generation of ECV-maps feasible for clinical work flow.


Journal of Cardiovascular Magnetic Resonance | 2012

Extracellular volume fraction mapping in the myocardium, part 2: initial clinical experience

Peter Kellman; Joel R Wilson; Hui Xue; W. Patricia Bandettini; Sujata M Shanbhag; Kirk M. Druey; Martin Ugander; Andrew E. Arai

BackgroundDiffuse myocardial fibrosis, and to a lesser extent global myocardial edema, are important processes in heart disease which are difficult to assess or quantify with cardiovascular magnetic resonance (CMR) using conventional late gadolinium enhancement (LGE) or T1-mapping. Measurement of the myocardial extracellular volume fraction (ECV) circumvents factors that confound T1-weighted images or T1-maps. We hypothesized that quantitative assessment of myocardial ECV would be clinically useful for detecting both focal and diffuse myocardial abnormalities in a variety of common and uncommon heart diseases.MethodsA total of 156 subjects were imaged including 62 with normal findings, 33 patients with chronic myocardial infarction (MI), 33 with hypertrophic cardiomyopathy (HCM), 15 with non-ischemic dilated cardiomyopathy (DCM), 7 with acute myocarditis, 4 with cardiac amyloidosis, and 2 with systemic capillary leak syndrome (SCLS). Motion corrected ECV maps were generated automatically from T1-maps acquired pre- and post-contrast calibrated by blood hematocrit. Abnormally-elevated ECV was defined as >2SD from the mean ECV in individuals with normal findings. In HCM the size of regions of LGE was quantified as the region >2 SD from remote.ResultsMean ECV of 62 normal individuals was 25.4 ± 2.5% (m ± SD), normal range 20.4%-30.4%. Mean ECV within the core of chronic myocardial infarctions (without MVO) (N = 33) measured 68.5 ± 8.6% (p < 0.001 vs normal). In HCM, the extent of abnormally elevated ECV correlated to the extent of LGE (r = 0.72, p < 0.001) but had a systematically greater extent by ECV (mean difference 19 ± 7% of slice). Abnormally elevated ECV was identified in 4 of 16 patients with non-ischemic DCM (38.1 ± 1.9% (p < 0.001 vs normal) and LGE in the same slice appeared “normal” in 2 of these 4 patients. Mean ECV values in other disease entities ranged 32-60% for cardiac amyloidosis (N = 4), 40-41% for systemic capillary leak syndrome (N = 2), and 39-56% within abnormal regions affected by myocarditis (N = 7).ConclusionsECV mapping appears promising to complement LGE imaging in cases of more homogenously diffuse disease. The ability to display ECV maps in units that are physiologically intuitive and may be interpreted on an absolute scale offers the potential for detection of diffuse disease and measurement of the extent and severity of abnormal regions.


Circulation-cardiovascular Interventions | 2010

A Pilot Study of Rapid Cooling by Cold Saline and Endovascular Cooling Before Reperfusion in Patients With ST-Elevation Myocardial Infarction

Matthias Götberg; Göran Olivecrona; Sasha Koul; Marcus Carlsson; Henrik Engblom; Martin Ugander; Jesper van der Pals; Lars Algotsson; Håkan Arheden; David Erlinge

Background—Experimental studies have shown that induction of hypothermia before reperfusion of acute coronary occlusion reduces infarct size. Previous clinical studies, however, have not been able to show this effect, which is believed to be mainly because therapeutic temperature was not reached before reperfusion in the majority of the patients. We aimed to evaluate the safety and feasibility of rapidly induced hypothermia by infusion of cold saline and endovascular cooling catheter before reperfusion in patients with acute myocardial infarction. Methods and Results—Twenty patients with acute myocardial infarction scheduled to undergo primary percutaneous coronary intervention were enrolled in this prospective, randomized study. After 4±2 days, myocardium at risk and infarct size were assessed by cardiac magnetic resonance using T2-weighted imaging and late gadolinium enhancement imaging, respectively. A core body temperature of <35°C (34.7±0.3°C) was achieved before reperfusion without significant delay in door-to-balloon time (43±7 minutes versus 40±6 minutes, hypothermia versus control, P=0.12). Despite similar duration of ischemia (174±51 minutes versus 174±62 minutes, hypothermia versus control, P=1.00), infarct size normalized to myocardium at risk was reduced by 38% in the hypothermia group compared with the control group (29.8±12.6% versus 48.0±21.6%, P=0.041). This was supported by a significant decrease in both peak and cumulative release of Troponin T in the hypothermia group (P=0.01 and P=0.03, respectively). Conclusions—The protocol demonstrates the ability to reach a core body temperature of <35°C before reperfusion in all patients without delaying primary percutaneous coronary intervention and that combination hypothermia as an adjunct therapy in acute myocardial infarction may reduce infarct size at 3 days as measured by MRI. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT00417638.


Journal of Cardiovascular Magnetic Resonance | 2011

Myocardial T1 and Extracellular Volume Fraction Mapping at 3 Tesla

Jason J. Lee; Songtao Liu; Marcelo Souto Nacif; Martin Ugander; Jing Han; Nadine Kawel; Christopher T. Sibley; Peter Kellman; Andrew E. Arai; David A. Bluemke

BackgroundTo compare 11 heartbeat (HB) and 17 HB modified lock locker inversion recovery (MOLLI) pulse sequence at 3T and to establish preliminary reference values for myocardial T1 and the extracellular volume fraction (ECV).MethodsBoth phantoms and normal volunteers were scanned at 3T using 11 HB and 17 HB MOLLI sequence with the following parameters: spatial resolution = 1.75 × 1.75 × 10 mm on a 256 × 180 matrix, TI initial = 110 ms, TI increment = 80 ms, flip angle = 35°, TR/TE = 1.9/1.0 ms. All volunteers were administered Gadolinium-DTPA (Magnevist, 0.15 mmol/kg), and multiple post-contrast MOLLI scans were performed at the same pre-contrast position from 3.5-23.5 minutes after a bolus contrast injection. Late gadolinium enhancement (LGE) images were also acquired 12-30 minutes after the gadolinium bolus.ResultsT1 values of 11 HB and 17 HB MOLLI displayed good agreement in both phantom and volunteers. The average pre-contrast myocardial and blood T1 was 1315 ± 39 ms and 2020 ± 129 ms, respectively. ECV was stable between 8.5 to 23.5 minutes post contrast with an average of 26.7 ± 1.0%.ConclusionThe 11 HB MOLLI is a faster method for high-resolution myocardial T1 mapping at 3T. ECV fractions are stable over a wide time range after contrast administration.


BMC Medical Imaging | 2009

Age and gender specific normal values of left ventricular mass, volume and function for gradient echo magnetic resonance imaging: a cross sectional study

Peter A. Cain; Ragnhild Ahl; Erik Hedström; Martin Ugander; Ase Allansdotter-Johnsson; Peter Friberg; Håkan Arheden

BackgroundKnowledge about age-specific normal values for left ventricular mass (LVM), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) by cardiac magnetic resonance imaging (CMR) is of importance to differentiate between health and disease and to assess the severity of disease. The aims of the study were to determine age and gender specific normal reference values and to explore the normal physiological variation of these parameters from adolescence to late adulthood, in a cross sectional study.MethodsGradient echo CMR was performed at 1.5 T in 96 healthy volunteers (11–81 years, 50 male). Gender-specific analysis of parameters was undertaken in both absolute values and adjusted for body surface area (BSA).ResultsAge and gender specific normal ranges for LV volumes, mass and function are presented from the second through the eighth decade of life. LVM, ESV and EDV rose during adolescence and declined in adulthood. SV and EF decreased with age. Compared to adult females, adult males had higher BSA-adjusted values of EDV (p = 0.006) and ESV (p < 0.001), similar SV (p = 0.51) and lower EF (p = 0.014). No gender differences were seen in the youngest, 11–15 year, age range.ConclusionLV volumes, mass and function vary over a broad age range in healthy individuals. LV volumes and mass both rise in adolescence and decline with age. EF showed a rapid decline in adolescence compared to changes throughout adulthood. These findings demonstrate the need for age and gender specific normal ranges for clinical use.


Journal of Magnetic Resonance Imaging | 2011

Myocardial T1 Mapping with MRI: comparison of Look-Locker and MOLLI sequences

Marcelo Souto Nacif; Evrim B. Turkbey; Neville Gai; Saman Nazarian; Rob J. van der Geest; Radwa A. Noureldin; Christopher T. Sibley; Martin Ugander; Songtao Liu; Andrew E. Arai; Joao A.C. Lima; David A. Bluemke

To evaluate the relationship between “Look‐Locker” (LL) and modified Look‐Locker Inversion recovery (MOLLI) approaches for T1 mapping of the myocardium.


BMC Cardiovascular Disorders | 2008

Rapid short-duration hypothermia with cold saline and endovascular cooling before reperfusion reduces microvascular obstruction and myocardial infarct size

Matthias Götberg; Göran Olivecrona; Henrik Engblom; Martin Ugander; Jesper van der Pals; Einar Heiberg; Håkan Arheden; David Erlinge

BackgroundThe aim of this study was to evaluate the combination of a rapid intravenous infusion of cold saline and endovascular hypothermia in a closed chest pig infarct model.MethodsPigs were randomized to pre-reperfusion hypothermia (n = 7), post-reperfusion hypothermia (n = 7) or normothermia (n = 5). A percutaneous coronary intervention balloon was inflated in the left anterior descending artery for 40 min. Hypothermia was started after 25 min of ischemia or immediately after reperfusion by infusion of 1000 ml of 4°C saline and endovascular hypothermia. Area at risk was evaluated by in vivo SPECT. Infarct size was evaluated by ex vivo MRI.ResultsPre-reperfusion hypothermia reduced infarct size/area at risk by 43% (46 ± 8%) compared to post-reperfusion hypothermia (80 ± 6%, p < 0.05) and by 39% compared to normothermia (75 ± 5%, p < 0.05). Pre-reperfusion hypothermia infarctions were patchier in appearance with scattered islands of viable myocardium. Pre-reperfusion hypothermia abolished (0%, p < 0.001), and post-reperfusion hypothermia significantly reduced microvascular obstruction (10.3 ± 5%; p < 0.05), compared to normothermia: (30.2 ± 5%).ConclusionRapid hypothermia with cold saline and endovascular cooling before reperfusion reduces myocardial infarct size and microvascular obstruction. A novel finding is that hypothermia at the onset of reperfusion reduces microvascular obstruction without reducing myocardial infarct size. Intravenous administration of cold saline combined with endovascular hypothermia provides a method for a rapid induction of hypothermia suggesting a potential clinical application.

Collaboration


Dive into the Martin Ugander's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peter Kellman

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Andrew E. Arai

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Björn Wieslander

Karolinska University Hospital

View shared research outputs
Researchain Logo
Decentralizing Knowledge