Martin Uggowitzer
University of Graz
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Martin Uggowitzer.
European Radiology | 2002
Schreyer Hh; Martin Uggowitzer; Ruppert-Kohlmayr A
Abstract. Despite of the diagnostic potential of conventional CT (CCT), limitations being inherent in this technology reduce its diagnostic confidence and limit clinical CT applications as 3D imaging. Helical CT (HCT) has far overcome the limitations of CCT and has become the standard CT technology. After a short overview on the technique of HCT and its advantages over CCT, the impact of HCT on the detection of disorders of the urinary organs is discussed. Due to the high quality of 3D reconstructions, vessels are visualized free of artefacts resulting in a dramatic improvement and acceptance of CT angiography, which has become a clinically important examination in the evaluation of obstructive renal artery disease. Fast HCT provides a precise assessment of the three phases of the nephrogram and it is a prerequisite for an improved depiction of abnormal vascular perfusion and impaired tubule transit of contrast material. Helical CT enables an improved characterization of cystic mass lesions reducing the diagnosis of indeterminate masses and thus facilitating a better therapeutic management. The diagnosis of renal cell carcinomas (RCC) has improved due to an increased sensitivity in detecting small RCCs, and an increased specificity in the diagnosis of neoplastic lesions. Improved staging of RCCs is the result of accurate assessment of venous tumour extension. When planning nephron-sparing surgery 3D display of the renal tumour helps to determine the resectability of the mass depicting its relation to major renal vessels and the renal collecting system. In the evaluation of renal trauma HCT provides shorter scanning time and thus fewer artefacts in the examination of traumatized patients who cannot cooperate adequately. Three-dimensional postprocessing modalities allow the assessment of the renal vascular pedicel by CT angiography and improve the demonstration of complex lacerations of the renal parenchyma. In the evaluation of the upper urinary tract unenhanced HCT has become the imaging method of choice in the diagnosis and differential diagnosis of acute flank pain since it is highly sensitive and specific in detecting calculus disease. Unenhanced HCT may furthermore demonstrate causes of flank pain unrelated to urolithiasis. Gapless volume scanning and improved resolution in the z-axis during the excretory phase enables improved visualization of the renal collecting systems and ureters, resulting in a better demonstration of intraluminal and extraluminal pathology.
Journal of Computer Assisted Tomography | 2003
Helmut Schoellnast; Manfred Tillich; Hannes Deutschmann; Michael J. Deutschmann; Gerald A. Fritz; Uwe Stessel; Gottfried J. Schaffler; Martin Uggowitzer
ObjectiveTo evaluate the potential of a saline solution flush after the contrast material bolus in abdominal multidetector row CT (MDCT) in contrast material dose and cost reduction. MethodsAbdominal MDCT was performed in 78 patients who were assigned randomly to 2 groups receiving 120 mL nonionic contrast material (300 mgI/mL) alone or 100 mL of the same contrast material pushed with 40 mL of saline solution. Mean attenuation values for both groups were measured in the liver, the spleen, the pancreas, the portal vein, the inferior vena cava, and the abdominal aorta. Cost analyses were performed for both groups. ResultsThere was no significant difference in parenchymal and vascular enhancement between both groups. The difference of the enhancement was 2 HU for the liver (P = 0.11), 2 HU for the spleen (P = 0.44), 3 HU for the pancreas (P = 0.38), 9 HU for the portal vein (P = 0.11), 3 HU for the inferior vena cava (P = 0.55), and 10 HU for the aorta (P = 0.06). Taking the costs of contrast material, saline solution, and disposal material into account,
European Journal of Radiology | 1999
Reinhard Groell; Karl H Peichel; Martin Uggowitzer; Ferdinand Schmid; Karin Hartwagner
7.30 was saved by the patient using a saline solution flush. ConclusionsUsing a saline flush after the contrast material bolus in abdominal MDCT allows an iodine dose reduction of approximately 6 g, or 17%, without impairing mean parenchymal and vascular enhancement and a cost reduction of
Surgical and Radiologic Anatomy | 1997
Reinhard Groell; Gottfried J. Schaffler; Martin Uggowitzer; Dieter H. Szolar; K. Muellner
7.30 per patient.
Journal of Ultrasound in Medicine | 1999
Martin Uggowitzer; C Kugler; H J Mischinger; R Gröll; A Ruppert-Kohlmayr; Klaus W. Preidler; F Quehenberger
OBJECTIVE To evaluate the potential of spiral computed tomography (CT) densitometry of the lung to assess segmental perfusion defects in patients with acute pulmonary embolism. MATERIALS AND METHODS Ten patients with known segmental or lobar perfusion defects on ventilation/perfusion scintigraphy and with normal findings in the contralateral lung segment underwent spiral CT of the thorax before and after the administration of contrast material. Regions of interest were defined in 14 segments with normal perfusion and in 14 segments with reduced perfusion. Three consecutive densitometry measurements were performed in each segment. RESULTS Those segments with reduced perfusion showed a significantly lower mean CT value on the enhanced scans (-813.4 +/- 57.1 Hounsfield units (HU) vs -794.0 +/- 44.8 HU, P = 0.01) and a significantly decreased contrast enhancement (12.3 +/- 18.2 HU vs 29.8 +/- 16.6 HU, P <0.01) when compared to segments with normal perfusion. Measurements from the unenhanced CT scans were not statistically different between segments with reduced and normal perfusion. CONCLUSIONS Spiral CT densitometry allows the assessment of at least segmental perfusion defects in patients with acute pulmonary embolism.
Journal of Ultrasound in Medicine | 2000
Michael Riccabona; Martin Uggowitzer; Erich Klein; Franz Lindbichler; Franz Ebner; Richard Fotter
Recent developments in ophthalmology such as balloon dilatation, stent implantation, laser therapy and endoscopy of the lacrimal drainage system raise the need for a detailed anatomical knowledge of this system. In this study morphometric measurements of the lacrimal drainage system were performed with thin-section axial computed tomography (CT) examinations in 147 patients with no signs of pathology related to the lacrimal drainage system. The mean length of the nasolacrimal duct measured 11.2 ± 2.6mm (range: 6-21 mm), the narrowest diameter was 3.7 ± 0.7 mm (range: 2-7 mm). The mean length of the nasolacrimal sac was 11.8 ± 2.5 mm (range: 6-18 mm). The width of the nasolacrimal sac did not exceed 4 mm unless filled with air. In 43 (29.3%) of the subjects air was visible within the nasolacrimal sac or duct. The knowledge of the morphometry of the lacrimal drainage system enables the ophthalmologist to plan intervention on the lacrimal drainage system precisely and avoid unnecessary manipulations.
CardioVascular and Interventional Radiology | 1997
Klaus A. Hausegger; Hans J. Mischinger; Radenko Karaic; Guenther E. Klein; Cristian Kugler; Robert Kern; Martin Uggowitzer; Dieter H. Szolar
Lesions of focal nodular hyperplasia are hypervascular, benign focal liver lesions whose differentiation from other focal liver lesions is of significant clinical relevance. The purpose of this study was to investigate the echo‐enhancing agent SHU 508A (Levovist) in the evaluation of focal nodular hyperplasia with Doppler sonography. We examined 49 patients with 71 lesions of focal nodular hyperplasia in the liver with gray scale and power Doppler sonography. In all patients Levovist was administered intravenously in a concentration of 300 to 400 mg galactose per milliliter. Visualization of the feeding vessels and the vascularity of the lesions were evaluated, and the resistive indices in the feeders and the hepatic arteries were assessed. In comparison with unenhanced power Doppler sonography, echo‐enhanced power Doppler sonography yields a higher sensitivity in the detection of the feeding artery (97% versus 82%) in focal nodular hyperplasia and in the depiction of the radial vascular architecture in such lesions, especially those located in the left lobe of the liver. Lesions less than 3 cm in diameter do not consistently show a characteristic vascular architecture with echo‐enhanced Doppler sonography. The resistive index of the tumor‐feeding artery (mean, 0.51 +/‐ 0.09) is significantly (P < 0.0001) lower than that of the hepatic artery (mean, 0.65 +/‐ 0.06) and decreases as the size of the focal nodular hyperplasia increases. The administration of Levovist may improve the signal‐to‐noise ratio and thus visualization of the vascular architecture in focal nodular hyperplasia. Lesions located in the left lobe of the liver, which commonly are subject to disturbing motion artifacts in color Doppler sonography, will significantly benefit from the administration of Levovist. Echo‐enhanced power Doppler sonography, however, is not capable of depicting a characteristic vascular pattern in small (< or = 3 cm) lesions of focal nodular hyperplasia that would guarantee a specific diagnosis.
Acta Radiologica | 1999
Michael Riccabona; D. Szolar; K. Preidler; Martin Uggowitzer; Christian Kugler; O. Dörfler; H. H. Schreyer
Fifty‐one patients, with a range of underlying pathologic conditions, were studied prospectively to assess the diagnostic value of echo‐enhanced color Doppler sonography in the pediatric and adolescent population Their diagnoses included various tumors, vascular disorders, cerebral bleeding, pathologic conditions of small parts, and focal lesions of parenchymal organs. All patients underwent color Doppler sonography before proceeding to echo‐enhanced color Doppler sonography. Diagnoses were confirmed by additional imaging (computed tomography, magnetic resonance imaging, angiography, and scintigraphy) performed as appropriate, with or without histologic study. An additional 20 children did not proceed to echoenhanced color Doppler sonography as color Doppler sonography alone was found to be sufficiently diagnostic. Levovist (SHU 508A), a contrast agent based on galactose‐encapsulated air microbubbles, is approved for pediatric applications in Austria and was used as the echo‐enhancing agent. Echo‐enhanced color Doppler sonography was performed a total of 63 times in 51 patients (mean age, 9.8 years). Compared to color Doppler sonography, echo‐enhanced color Doppler sonography either detected or enhanced visualization of pathologic conditions in 55 investigations (87.3%), yielding an overall accuracy of 95.2% (sensitivity, 95%), versus 65.7% with color Doppler sonography. One spinal arteriovenous malformation, one cerebral cavernoma, and one liver lesion were missed. The contrast material was easy to administer; no adverse reactions were observed. We conclude that echoenhanced color Doppler sonography is beneficial in pediatric sonography. It enhances visualization of vessels and perfusion, thus offering a nonionizing imaging tool for detection and follow‐up evaluation of pathologic conditions with disturbed vasculature in specific cases. In infants and in persons with superficial lesions it did not offer significant advantages over color Doppler sonography.
Wiener Klinische Wochenschrift | 2009
Reinhard Moser; Gerolf Schweintzger; Martin Uggowitzer; Christian Urban; Heinz Stammberger; Hans Eder; Reinhold Kerbl
PurposeTo reevaluate the reasons for the occlusion of self-expanding biliary metal stents, on the basis of cholangioscopic findings.MethodsPercutaneous transhepatic cholangioscopy (PTCS) was performed in 15 patients with obstructed biliary Wallstents. The reason for stent insertion was a malignant obstruction in 14 patients; 1 had a benign biliary stricture. Conventional noncovered stents had been inserted in 12 patients; in 3 cases a polyurethane-covered prototype Wallstent had been used. Stent occlusions occurred after 1–55 months. PTCS was performed with a 2.3-mm endoscope through an 11 Fr sheath. Biopsies were taken via the working channel of the endoscope.ResultsIn all patients with noncovered stents the inner surface of the stent was highly irregular with seaweed-like protrusions (biopsy-proven granulation tissue). Stent incorporation varied from absent (n=1) to subtotal (n=8), but was always incomplete, no matter how long the stent had been in place. Tumor ingrowth was histologically proven in 2 patients. One patient had a large occluding concrement at the proximal end of the stent. In patients with covered stents, the inner surface appeared more regular; however, viable granulation tissue was found inside two stents and tumor ingrowth in one of them.ConclusionPTCS showed that incorporation of the stent is virtually always incomplete. The factors contributing most to stent occlusion are the buildup of granulation tissue, bile sludge, and tumor overgrowth. Stone formation and tumor ingrowth can also be important, although less common causes of occlusion. A polyurethane stent covering could not prevent tumor ingrowth in one patient and the buildup of viable granulation tissue inside the stent in two further patients; mean stent patency in the three patients with such a stent was 3 months.
Urologia Internationalis | 2003
Helga Habermann; Martin Benesch; Luigi Schips; Karl Pummer; Manfred Ratschek; Martin Uggowitzer; Christian Urban; Gerhart Hubmer
Objective: To assess the efficacy of amplitude coded colour Doppler US (aCDS) in the evaluation of renal masses as shown by multiphasic contrast-enhanced CT. Material and Methods: Eighty patients (155 kidneys) with suspicion of renal masses underwent aCDS and spiral CT. The findings were classified into normal kidneys, kidneys with tumours, kidneys with cysts, and those with “other findings” (i.e. bleeding, calcifications, inflammation, parenchymal hypertrophy). The aCDS findings were compared to CT results and to histological findings or clinical, laboratory and follow-up data. Results: Eighteen renal cell carcinomas and 8 other tumours were found; 78 kidneys had cysts, 12 polycystic kidneys and 10 fibrotic kidneys were detected, 20 kidneys showed other findings. Diagnostic aCDS data were obtained in 129 kidneys (83.2%) showing pathology with an accuracy of 94%. CT adequately showed pathology in all patients with some diagnostic uncertainty in the evaluation of complicated cysts. Conclusion: Though contrast-enhanced multiphasic spiral CT is the method of choice for evaluating renal masses, US including aCDS can provide valuable information, particularly in differentiating vascularized from non-vascularized lesions and in the evaluation of complicated renal cysts.