Featured researches published by Martino Martinelli Filho.


Pacing and Clinical Electrophysiology | 2002

Incidence and Risk Factors of Upper Extremity Deep Vein Lesions After Permanent Transvenous Pacemaker Implant: A 6-Month Follow-Up Prospective Study

Sergio S. C. Costa; Augusto Scalabrini Neto; Roberto Costa; José Guilherme Mendes Pereira Caldas; Martino Martinelli Filho

DO CARMO DA COSTA, S.S., et al.: Incidence and Risk Factors of Upper Extremity Deep Vein Lesions After Permanent Transvenous Pacemaker Implant: A 6‐Month Follow‐Up Prospective Study. The incidence of venous lesions after permanent pacemaker insertion is around 45%. However, this incidence has been based on retrospective studies in a small series; moreover, factors predicting the development of these venous injuries have not been clearly defined. The aim of this study was to identify the risk factors for higher incidence of upper extremity deep vein thrombosis after transvenous permanent pacemaker insertion. The study included 229 patients and the criteria were age above 12 years and first permanent transvenous pacemaker implant. Exclusion criteria were pulmonary embolism, lower or upper extremity deep venous thrombosis, previous use of central venous catheters, coagulation disturbances, and malignancy. Age, race, sex, underlying cardiac disease, functional class to heart failure, LVEF, venous access, number, material and caliber of the leads, and previous use of a transvenous temporary pacemaker were considered. Six months after the pacemaker was implanted, 202 patients were submitted to digital subtraction venography ipsilateral to pacemaker implant. The venographies were normal in 73 (36%) patients and abnormal in 129 (64%) patients. Patients with previous use of transvenous temporary leads (P = 0,0001, OR = 4,260, confidence limits = 2,133–8,465) and LVEF ≤ 40% (P = 0,0378, OR = 3,437, confidence limits = 1,064–12,326), had higher incidence of venous lesions. Previous use of a temporary pacemaker and LVEF ≤ 0.40 were considered independent risk factors to a higher incidence of venous stenosis or thrombosis 6 months after permanent pacemaker insertion.


Journal of Cardiac Failure | 2010

Conventional Versus Biventricular Pacing in Heart Failure and Bradyarrhythmia: The COMBAT Study

Martino Martinelli Filho; Sérgio Freitas de Siqueira; Roberto Costa; Oswaldo Tadeu Greco; Luiz Felipe P. Moreira; Andre d'Avila; E. Kevin Heist

BACKGROUND Worsening in clinical and cardiac status has been noted after chronic right ventricular pacing, but it is uncertain whether atriobiventricular (BiVP) is preferable to atrio-right ventricular pacing (RVP). Conventional versus Multisite Pacing for BradyArrhythmia Therapy study (COMBAT) sought to compare BiVP versus RVP in patients with symptomatic heart failure (HF) and atrioventricular (AV) block. METHODS AND RESULTS COMBAT is a prospective multicenter randomized double blind crossover study. Patients with New York Heart Association functional class (FC) II-IV, left ventricular ejection fraction (LVEF) <40%, and AV block as an indication for pacing were enrolled. All patients underwent biventricular system implantation and then were randomized to receive successively (group A) RVP-BiVP-RVP, or (group B) BiVP-RVP-BiVP. At the end of each 3-month crossover period, patients were evaluated according to Quality of Life (QoL), FC, echocardiographic parameters, 6-Minute Walk Test (6MWT), and peak oxygen consumption (VO(2 max)). Sixty patients were enrolled, and the mean follow-up period was 17.5 +/- 10.7 months. There were significant improvements in QoL, FC, LVEF, and left ventricular end-systolic volume with BiVP compared with RVP. The effects of pacing mode on 6MWT and VO(2 max) were not significantly different. Death occurred more frequently with RVP. CONCLUSION In patients with systolic HF and AV block requiring permanent ventricular pacing, BiVP is superior to RVP and should be considered the preferred pacing mode.


Arquivos Brasileiros De Cardiologia | 2007

Incidência de choques e qualidade de vida em jovens com cardioversor-desfibrilador implantável

Roberto Costa; Kátia Regina da Silva; Rodrigo de Castro Mendonça; Silvana Nishioka; Sérgio de Freitas Siqueira; Wagner Tetsuji Tamaki; Elizabeth Sartori Crevelari; Luiz Felipe P. Moreira; Martino Martinelli Filho

OBJECTIVES To analyze the incidence and causes of ICD therapies in children and young adults and verify their impact on the quality of life (QoL). METHODS From March/1977 to February/2006, 29 patients (15.7+/-5.4 years old) were submitted to ICD implants. Aborted cardiac arrest (41.5%), sustained ventricular tachycardia (27.6%) and primary prophylaxis of sudden cardiac death (30.9%) indicated device therapy. The number of therapies was evaluated by interviewing patients and by ICD diagnostic data. The SF-36 questionnaire was used to measure the QoL and the results were compared to healthy population. The expectative of freedom from ICD therapies were estimated by the Kaplan-Meier method. RESULTS After 2.6+/-1.8 years follow-up, 8 (27.6%) patients received 141 appropriate ICD shocks due to ventricular tachycardia (6) or ventricular fibrillation (2), and 11 (37.9%) patients received 152 inappropriate ICD shocks due to supraventricular tachyarrhythmias (8) or oversensing (3). Expectative of freedom from appropriate shocks was 74.2+/-9.0% and 66.7+/-10.7% after one and three years, respectively. Compared to healthy population, QoL decreased in physical function (61.7+/-28.7), vitality (64.7+/-19.1), mental health (65.9+/-22.7) and role-emotional domains (66.7+/-38.5). All patients referred fear and concern related to ICD use. CONCLUSION Despite the efficacy of ICD therapies, the high incidence of appropriate and inappropriate shocks interfered in patients QoL and adaptation to the device.


Arquivos Brasileiros De Cardiologia | 2002

Biventricular Pacing Improves Clinical Behavior and Reduces Prevalence of Ventricular Arrhythmia in Patients with Heart Failure

Martino Martinelli Filho; Anísio Pedrosa; Roberto Costa; Silvana Nishioka; Sérgio Freitas de Siqueira; Wagner Tetsuji Tamaki; Eduardo Sosa

PURPOSE To analyze the influence of biventricular pacing (BP) on clinical behavior, ventricular arrhythmia (VA) prevalence, and left ventricular ejection fraction (LV EF) by gated ventriculography. METHODS Twenty-four patients with left bundle branch block (LBBB) and NYHA class III and IV underwent pacemaker implantation and were randomized either to the conventional or BP group, all receiving BP after 6 months. RESULTS Sixteen patients were in NYHA class IV (66.6%) and 8 were in class III (33.4%). After 1-year follow-up, 14 patients were in class II (70%) and 5 were in class III (25%). Two sudden cardiac deaths occurred. A significant reduction in QRS length was found with BP (p=0.006). A significant statistical increase, from a mean of 19.13 +/- 5.19% (at baseline) to 25.33 +/- 5.90% (with BP) was observed in LVEF Premature ventricular contraction prevalence decreased from a mean of 10,670.00 +/- 12,595.39 SD or to a mean of 3,007.00 +/- 3,216.63 SD PVC/24 h with BP (p<0.05). Regarding the hospital admission rate over 1 year, we observed a significant reduction from 60. To 16 admissions with BP (p<0.05). CONCLUSION Patients with LBBB and severe heart failure experienced, with BP, a significant NYHA class and LVEF improvement. A reduction in the hospital admission rate and VA prevalence also occurred.


Arquivos Brasileiros De Cardiologia | 2002

Cardiac Damage from Chronic Use of Chloroquine: A Case Report and Review of the Literature

Ricardo Alkmim Teixeira; Martino Martinelli Filho; Luiz Alberto Benvenuti; Roberto Costa; Anísio Pedrosa; Silvana Nishioka

Chloroquine has been widely used in rheumatological treatment, but potential severe side effects require careful follow-up. Cardiac damage is not a common consequence, but its clinical relevance has not yet been described. We report the case of a 58-year-old woman with rheumatoid arthritis, in whom chronic chloroquine use resulted in major irreversible cardiac damage. She presented with syncopal episodes due to complete atrioventricular block confirmed by electrophysiological study whose changes were concluded to be irreversible and a permanent pacemaker was indicated. Endomyocardial biopsy was also performed to search for histopathological and ultrastructural cardiac damage. We also reviewed the 22 cases of chloroquine-induced cardiopathy described to date as well as its pathophysiology.


Pacing and Clinical Electrophysiology | 2003

Transfemoral pediatric permanent pacing: Long-term results

Roberto Costa; Martino Martinelli Filho; Wagner Tetsuji Tamaki; Elizabeth Sartorio Crevelari; Silvana Nishioka; Luiz Felipe P. Moreira; Sérgio Almeida de Oliveira

COSTA, R., et al.: Transfemoral Pediatric Permanent Pacing: Long‐term Results. The femoral vein has been used as an alternative conduit to implant pacemakers in children of any weight. Such method associates endocardial pacing and good cosmetics. The aim of this study was to evaluate prospectively, since 1981, the long‐term follow‐up of 99 children, from newborn to 13 years old (average = 4.1 ± 3.6 years, 56 girls), who underwent the implantation of pacemakers via the femoral vein. Atrioventricular block was present in 88% of patients, of congenital etiology in 39% and postoperative in 54%. Single chamber pacemakers were implanted in 92% of patients. During a mean follow‐up of 5.3 ± 5.0 years (maximum = 18.2 years), 5 patients died of cardiac causes, 4 of infection, 2 suddenly, and 3 of unknown causes. The 5‐, 10‐ and 15‐year actuarial survival rates were 83.7%, 75.7%, and 75.7%, respectively. Transfemoral leads were used for a mean of 48.9 ± 44.0 months. Reasons for lead explantations were pacing failure in five patients, infection in eight, and elective in nine. The 2‐, 5‐ and 10‐year actuarial survivals of transfemoral leads were 87.6%, 73.8%, and 31.8%, respectively. The mean lead survival was 97 months. Overall, 105 reoperations were performed, 38 for battery depletion, 24 for body growth, 14 for infection or pocket revisions, and 27 for miscellaneous reasons. In conclusion, the durability and overall long‐term performance of transfemoral leads were excellent. (PACE 2003; 26[Pt.II:487–491)


Journal of Cardiovascular Electrophysiology | 1994

Clinical and electrophysiologic features of syncope in chronic chagasic heart disease.

Martino Martinelli Filho; Eduardo Sosa; Silvana Nishioka; Mauricio Scanavacca; Giovanni Bellotti; Fúlvio Pileggi

Syncope in CCHD. Introduction: Syncope in patients with chronic Chagasic heart disease (CCHD) is a frequent hut poorly studied problem.


Arquivos Brasileiros De Cardiologia | 2005

Myotonic dystrophy and heart disease: behavior of arrhythmic events and conduction disturbances

Silvana Angelina; DOrio Nishioka; Martino Martinelli Filho; Suely Kazue Nagahashi Marie; Mayana Zatz; Roberto Costa; São Paulo

OBJECTIVE To study the prevalence and natural evolution of arrhythmic events and conduction disturbances in myotonic dystrophy; to correlate the genetic defect with cardiovascular findings; to assess cardiac mortality, frequency, and predictive factors of sudden death; to correlate the severity of the neuromuscular and cardiac involvement; and to define the role of the electrophysiological study (EPS), in myotonic dystrophy. METHODS Periodic clinical assessment and the following tests were performed in 83 consecutive patients with a mean follow-up of 42+/-30.63 months: complementary examinations, genetic tests, electrocardiography, echocardiography, and Holter; electrophysiological study was performed in 59 cases. RESULTS Atrial tachyarrhythmia was observed in 10 (12%) patients, NSVT in 14 (17%), first-degree AVB in 24 (29%), LBBB in 19 (23%), and RBBB in 13 (16%). Symptoms, an increase in the PR interval, QRS enlargement, LVEF < 60%, and age were predictive factors of death. Nine patients died (4 sudden deaths; 2 due to heart failure; 3 due to other causes). Electrophysiological study: H-V interval > 70 ms in 34% and > 100 ms in 11% (postprocainamide). CONCLUSION The prevalence of arrhythmic events and conduction disturbances ranged from 50% to 80% after 6 years, and did not correlate with the genetic defect. Atrial flutter was the most common sustained arrhythmia. Cardiac involvement increased as the neuromuscular disease became aggravated, but progression of the cardiac involvement was more rapid than that of the neuromuscular disease. Overall mortality was low (11%) and sudden death occurred in half of the cases. The EPS identified a group at risk for pacemaker implantation.


Europace | 2014

Evidence for cardiac safety and antiarrhythmic potential of chloroquine in systemic lupus erythematosus.

Ricardo Alkmim Teixeira; Eduardo Ferreira Borba; Anísio Pedrosa; Silvana Nishioka; Vilma dos Santos Trindade Viana; J.A.F. Ramires; Roberto Kalil-Filho; Eloisa Bonfa; Martino Martinelli Filho

AIMS To perform a comprehensive evaluation of heart rhythm disorders and the influence of disease/therapy factors in a large systemic lupus erythematosus (SLE) cohort. METHODS AND RESULTS Three hundred and seventeen consecutive patients of an ongoing electronic database protocol were evaluated by resting electrocardiogram and 142 were randomly selected for 24 h Holter monitoring for arrhythmia and conduction disturbances. The mean age was 40.2 ± 12.1 years and disease duration was 11.4 ± 8.1 years. Chloroquine (CQ) therapy was identified in 69.7% with a mean use of 8.5 ± 6.7 years. Electrocardiogram abnormalities were detected in 66 patients (20.8%): prolonged QTc/QTd (14.2%); bundle-branch block (2.5%); and atrioventricular block (AVB) (1.6%). Age was associated with AVB (P = 0.029) and prolonged QTc/QTd (P = 0.039) whereas anti-Ro/SS-A and Systemic Lupus Erythematosus Disease Activity Index (SLEDAI) scores were not (P > 0.05). Chloroquine was negatively associated with AVB (P = 0.01) as was its longer use (6.1 ± 6.9 vs. 1.0 ± 2.5 years, P = 0.018). Time of CQ use was related with the absence of AVB [odds ratio (OR) = 0.103; 95% confidence interval (CI) = 0.011-0.934, P = 0.043] in multiple logistic regression. Holter monitoring revealed abnormalities in 121 patients (85.2%): supraventricular ectopies (63.4%) and tachyarrhythmia (18.3%); ventricular ectopies (45.8%). Atrial tachycardia/fibrillation (AT/AF) were associated with shorter CQ duration (7.05 ± 7.99 vs. 3.63 ± 5.02 years, P = 0.043) with a trend to less CQ use (P = 0.054), and older age (P < 0.001). Predictors of AT/AF in multiple logistic regression were age (OR = 1.115; 95% CI = 1.059-1.174, P < 0.001) and anti-Ro/SS-A (OR = 0.172; 95% CI = 0.047-0.629, P = 0.008). CONCLUSIONS Chloroquine seems to play a protective role in the unexpected high rate of cardiac arrhythmias and conduction disturbances observed in SLE. Further studies are necessary to determine if this antiarrhythmic effect is due to the disease control or a direct effect of the drug.


Heart Rhythm | 2013

Novel approach to epicardial pacemaker implantation in patients with limited venous access

Roberto Costa; Mauricio Scanavacca; Kátia Regina da Silva; Martino Martinelli Filho; Roger G. Carrillo

BACKGROUND Limited venous access in certain patients increases the procedural risk and complexity of conventional transvenous pacemaker implantation. OBJECTIVE The purpose of this study was to determine a minimally invasive epicardial approach using pericardial reflections for dual-chamber pacemaker implantation in patients with limited venous access. METHODS Between June 2006 and November 2011, 15 patients underwent epicardial pacemaker implantation. Procedures were performed through a minimally invasive subxiphoid approach and pericardial window with subsequent fluoroscopy-assisted lead placement. Mean patient age was 46.4 ± 15.3 years (9 male [(60.0%], 6 female [40.0%]). The new surgical approach was used in patients determined to have limited venous access due to multiple abandoned leads in 5 (33.3%), venous occlusion in 3 (20.0%), intravascular retention of lead fragments from prior extraction in 3 (20.0%), tricuspid valve vegetation currently under treatment in 2 (13.3%), and unrepaired intracardiac defects in 2 (13.3%). RESULTS All procedures were successful with no perioperative complications or early deaths. Mean operating time for isolated pacemaker implantation was 231.7 ± 33.5 minutes. Lead placement on the superior aspect of right atrium, through the transverse sinus, was possible in 12 patients. In the remaining 3 patients, the atrial lead was implanted on the left atrium through the oblique sinus, the postcaval recess, or the left pulmonary vein recess. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 36.8 ± 25.1 months. CONCLUSION Epicardial pacemaker implantation through pericardial reflections is an effective alternative therapy for those patients requiring physiologic pacing in whom venous access is limited.

Collaboration


Dive into the Martino Martinelli Filho's collaboration.

Top Co-Authors

Avatar

Roberto Costa

University of São Paulo

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors