Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Mary Varsamidis is active.

Publication


Featured researches published by Mary Varsamidis.


PLOS ONE | 2014

First-in-Human Trial of a Novel Suprachoroidal Retinal Prosthesis

Lauren N. Ayton; Peter J. Blamey; Robyn H. Guymer; Chi D. Luu; David A. X. Nayagam; Nicholas C. Sinclair; Mohit N. Shivdasani; Jonathan Yeoh; Mark McCombe; Robert Briggs; Nicholas L. Opie; Joel Villalobos; Peter N. Dimitrov; Mary Varsamidis; Matthew A. Petoe; Chris McCarthy; Janine Walker; Nick Barnes; Anthony N. Burkitt; Chris E. Williams; Robert K. Shepherd; Penelope J. Allen

Retinal visual prostheses (“bionic eyes”) have the potential to restore vision to blind or profoundly vision-impaired patients. The medical bionic technology used to design, manufacture and implant such prostheses is still in its relative infancy, with various technologies and surgical approaches being evaluated. We hypothesised that a suprachoroidal implant location (between the sclera and choroid of the eye) would provide significant surgical and safety benefits for patients, allowing them to maintain preoperative residual vision as well as gaining prosthetic vision input from the device. This report details the first-in-human Phase 1 trial to investigate the use of retinal implants in the suprachoroidal space in three human subjects with end-stage retinitis pigmentosa. The success of the suprachoroidal surgical approach and its associated safety benefits, coupled with twelve-month post-operative efficacy data, holds promise for the field of vision restoration. Trial Registration Clinicaltrials.gov NCT01603576


Investigative Ophthalmology & Visual Science | 2011

Visual function tests as potential biomarkers in age-related macular degeneration.

Peter N. Dimitrov; Liubov D. Robman; Mary Varsamidis; Khin Zaw Aung; Galina Makeyeva; Robyn H. Guymer; Algis J. Vingrys

PURPOSE To evaluate the potential of psychophysical assessments of retinal function to provide diagnostic biomarkers of early age-related macular degeneration (AMD). METHODS Unilateral visual function was assessed in 221 participants (72.86 ± 9.94 years; 67% women) with early AMD (visual acuity better than 20/60) and 109 controls (73.07 ± 10.32 years; 65% women). Psychophysical assessment included steady state thresholds (4- and 14-Hz flicker and red and blue color) and dynamic tests (photostress recovery [PSR] and dark adaptation [DA]). All test parameters were compared in terms of their diagnostic capacity (sensitivity and specificity), reproducibility, and clinical applicability (test duration and participants perception of test difficulty). AMD status was determined by digital photography, according to the International Classification and Grading System. RESULTS All functional measurements were significantly worse, on average, in the AMD group than in the control group (P < 0.001). Static and dynamic parameters showed weak correlations (range, 0.003-0.225). Rod recovery in DA and cone recovery in PSR had the best diagnostic capacity (area under curve [AUC], receiver operating characteristic [ROC] analysis, 0.93 ± 0.016 and 0.85 ± 0.021, respectively). Considering diagnostic capacity together with test reproducibility and clinical applicability, the 14-Hz flicker gave the best outcome, followed by PSR. Combination of these two tests detected 71% of abnormal early AMD cases. CONCLUSIONS All the visual function tests had good diagnostic capacity. Combination of the 14-Hz flicker thresholds and dynamics of the PSR test provided optimal quantitative assessment of retinal function in early AMD, suggesting that this set is a potentially useful clinical tool for following progression of early AMD and assessing the efficacy of interventions.


Investigative Ophthalmology & Visual Science | 2014

Factors affecting perceptual thresholds in a suprachoroidal retinal prosthesis.

Mohit N. Shivdasani; Nicholas C. Sinclair; Peter N. Dimitrov; Mary Varsamidis; Lauren N. Ayton; Chi D. Luu; Thushara Perera; Hugh J. McDermott; Peter J. Blamey

PURPOSE The suprachoroidal location for a retinal prosthesis provides advantages over other locations in terms of a simplified surgical procedure and a potentially more stable electrode-neural interface. The aim of this study was to assess the factors affecting perceptual thresholds, and to optimize stimulus parameters to achieve the lowest thresholds in patients implanted with a suprachoroidal retinal prosthesis. METHODS Three patients with profound vision loss from retinitis pigmentosa were implanted with a suprachoroidal array. Perceptual thresholds measured on individual electrodes were analyzed as a function of stimulus (return configuration, pulse polarity, pulse width, interphase gap, and rate), electrode (area and number of ganged electrodes), and clinical (retinal thickness and electrode-retina distance) parameters. RESULTS A total of 92.8% of 904 measurements made up to 680 days post implantation yielded thresholds (range, 44-436 nanocoulombs [nC]) below the safe charge limit. Thresholds were found to vary between individuals and to depend significantly on electrode-retina distance, negligibly on retinal thickness, and not on electrode area or the number of ganged electrodes. Lowest thresholds were achieved when using a monopolar return, anodic-first polarity, short pulse widths (100 μs) combined with long interphase gaps (500 μs), and high stimulation rates (≥400 pulses per second [pps]). CONCLUSIONS With suprachoroidal stimulation, anodic-first pulses with a monopolar return are most efficacious. To enable high rates, an appropriate combination of pulse width and interphase gap must be chosen to ensure low thresholds and electrode voltages. Electrode-retina distance needs to be monitored carefully owing to its influence on thresholds. These results inform implantable stimulator specifications for a suprachoroidal retinal prosthesis. (ClinicalTrials.gov number, NCT01603576.).


PLOS ONE | 2013

Proof of concept, randomized, placebo-controlled study of the effect of simvastatin on the course of age-related macular degeneration

Robyn H. Guymer; Paul N. Baird; Mary Varsamidis; Lucy Busija; Peter N. Dimitrov; Khin Zaw Aung; Galina Makeyeva; Andrea J. Richardson; Lyndell Lim; Liubov D. Robman

Background HMG Co-A reductase inhibitors are ubiquitous in our community yet their potential role in age-related macular degeneration (AMD) remains to be determined. Methodology/Principal Findings Objectives: To evaluate the effect of simvastatin on AMD progression and the effect modification by polymorphism in apolipoprotein E (ApoE) and complement factor H (CFH) genes. Design: A proof of concept double-masked randomized controlled study. Participants: 114 participants aged 53 to 91 years, with either bilateral intermediate AMD or unilateral non-advanced AMD (with advanced AMD in fellow eye), BCVA≥20/60 in at least one eye, and a normal lipid profile. Intervention: Simvastatin 40 mg/day or placebo, allocated 1∶1. Main outcome measures: Progression of AMD either to advanced AMD or in severity of non-advanced AMD. Results. The cumulative AMD progression rates were 70% in the placebo and 54% in the simvastatin group. Intent to treat multivariable logistic regression analysis, adjusted for age, sex, smoking and baseline AMD severity, showed a significant 2-fold decrease in the risk of progression in the simvastatin group: OR 0.43 (0.18–0.99), p = 0.047. Post-hoc analysis stratified by baseline AMD severity showed no benefit from treatment in those who had advanced AMD in the fellow eye before enrolment: OR 0.97 (0.27–3.52), p = 0.96, after adjusting for age, sex and smoking. However, there was a significant reduction in the risk of progression in the bilateral intermediate AMD group compared to placebo [adjusted OR 0.23 (0.07–0.75), p = 0.015]. The most prominent effect was observed amongst those who had the CC (Y402H) at risk genotype of the CFH gene [OR 0.08 (0.02–0.45), p = 0.004]. No evidence of harm from simvastatin intervention was detected. Conclusion/Significance Simvastatin may slow progression of non-advanced AMD, especially for those with the at risk CFH genotype CC (Y402H). Further exploration of the potential use of statins for AMD, with emphasis on genetic subgroups, is warranted. Trial Registration Australian New Zealand Clinical Trial Registry (ANZCTR) ACTRN1260500032065


Investigative Ophthalmology & Visual Science | 2012

Relationship between Clinical Macular Changes and Retinal Function in Age-Related Macular Degeneration

Peter N. Dimitrov; Liubov D. Robman; Mary Varsamidis; Khin Zaw Aung; Galina Makeyeva; Lucy Busija; Algis J. Vingrys; Robyn H. Guymer

PURPOSE The aim of this study was to investigate the relationship between clinical macular changes and retinal function in age-related macular degeneration (AMD). METHODS We recruited 357 participants with visual acuity of better than 20/60 in the study eye, including 64 individuals with normal fundi and 293 AMD participants classified into 12 subgroups based upon the International Classification and Grading System. Visual function in the study eye was assessed using two steady-state tests (achromatic 14 Hz flicker [F14Hz] and isoluminant blue color [BCT]) and two adaptation measurements (cone photo-stress recovery rate [CRR] and rod dark adaptation recovery rate [RRR]). The groups were compared on their average psychophysical measurements and ranked according to functional deficiency. RESULTS Both adaptation parameters were significantly abnormal when only hard and/or intermediate drusen were evident (compared to controls, P < 0.023) and yielded considerably worse outcomes in cases with more advanced fundus changes (P < 0.001), but provided limited ability to discriminate between these cases (linear trend, CRR t = 0.68, P = 0.50 and RRR t = 1.76, P = 0.08). Steady-state measurements, however, declined gradually along the entire hierarchy of fundus changes (linear trend, F14Hz t = 10.16, P < 0.001 and BCT t = 11.19, P < 0.001) with F14Hz being able to detect significant functional change as early as in the intermediate drusen group, when compared to controls (P = 0.003). CONCLUSIONS Steady state thresholds (F14Hz and BCT) and clinical signs showed significant concordance across the spectrum of early AMD fundus changes. This suggests that these tests may be an effective tool for monitoring progression of AMD to supplement clinical grading.


Archives of Ophthalmology | 2012

Role of Flicker Perimetry in Predicting Onset of Late-Stage Age-Related Macular Degeneration

Chi D. Luu; Peter N. Dimitrov; Luba Robman; Mary Varsamidis; Galina Makeyeva; K. Z. Aung; Algis J. Vingrys; Robyn H. Guymer

OBJECTIVE To investigate the longitudinal changes in flicker perimetry in patients with age-related macular degeneration (AMD) as the condition progresses from early AMD to geographic atrophy (GA) or choroidal neovascularization (CNV). METHODS Patients with AMD and control subjects were recruited from a longitudinal study of retinal function in early AMD consisting of 187 participants. Only those who completed at least 4 consecutive, 6-monthly flicker perimetry tests were selected for this study. Study groups consisted of everyone who went on to develop GA (n = 16) or CNV (n = 5), controls (n = 24), and the high-risk, early- AMD participants whose eyes did not progress to GA or CNV (drusen >125 μm; n = 18). The flicker sensitivity was determined, and its rate of change during the 18 months before the clinical detection of late AMD was calculated. RESULTS Eyes that went on to develop GA or CNV had a significantly reduced mean (SD) flicker sensitivity in the months before clinical detection of GA (15.8 [5.6] dB) or CNV (19.1 [3.8] dB) compared with control eyes (22.9 [3.0] dB) (P < .001) and with eyes that did not progress to GA or CNV (21.4 [3.4] dB) (P < .001). The rate of change in flicker sensitivity was significantly increased in GA eyes (-0.07 dB/mo) (P < .001) but not in CNV eyes (0.006 dB/mo) (P = .56) compared with the control eyes (-0.003 dB/mo). CONCLUSIONS Flicker sensitivity is reduced in eyes that go on to develop late AMD. The rate of change in flicker sensitivities over time was particularly useful in predicting eyes and areas within the eye that subsequently develop GA.


Clinical Interventions in Aging | 2008

Can HMG Co-A reductase inhibitors ("statins") slow the progression of age-related macular degeneration? The age-related maculopathy statin study (ARMSS).

Robyn H. Guymer; Peter N. Dimitrov; Mary Varsamidis; Lyndell Lim; Paul N. Baird; Algis J. Vingrys; Luba Robman

Age-related macular degeneration (AMD) is responsible for the majority of visual impairment in the Western world. The role of cholesterol-lowering medications, HMG Co-A reductase inhibitors or statins, in reducing the risk of AMD or of delaying its progression has not been fully investigated. A 3-year prospective randomized controlled trial of 40 mg simvastatin per day compared to placebo in subjects at high risk of AMD progression is described. This paper outlines the primary aims of the Age-Related Maculopathy Statin Study (ARMSS), and the methodology involved. Standardized clinical grading of macular photographs and comparison of serial macular digital photographs, using the International grading scheme, form the basis for assessment of primary study outcomes. In addition, macular function is assessed at each visit with detailed psychophysical measurements of rod and cone function. Information collected in this study will assist in the assessment of the potential value of HMG Co-A reductase inhibitors (statins) in reducing the risk of AMD progression.


Ophthalmology | 2009

Gene-environment interactions and aging visual function: a classical twin study.

Ruth E. Hogg; Peter N. Dimitrov; Mohamed Dirani; Mary Varsamidis; Matthew Chamberlain; Paul N. Baird; Robyn H. Guymer; Algis J. Vingrys

OBJECTIVE To elucidate the contribution of environmental versus genetic factors to the significant losses in visual function associated with normal aging. DESIGN A classical twin study. PARTICIPANTS Forty-two twin pairs (21 monozygotic and 21 dizygotic; age 57-75 years) with normal visual acuity recruited through the Australian Twin Registry. METHODS Cone function was evaluated by establishing absolute cone contrast thresholds to flicker (4 and 14 Hz) and isoluminant red and blue colors under steady state adaptation. Adaptation dynamics were determined for both cones and rods. Bootstrap resampling was used to return robust intrapair correlations for each parameter. MAIN OUTCOME MEASURES Psychophysical thresholds and adaptational time constants. RESULTS The intrapair correlations for all color and flicker thresholds, as well as cone absolute threshold, were significantly higher in monozygotic compared with dizygotic twin pairs (P<0.05). Rod absolute thresholds (P = 0.28) and rod and cone recovery rate (P = 0.83; P = 0.79, respectively) did not show significant differences between monozygotic and dizygotic twins in their intrapair correlations, indicating that steady-state cone thresholds and flicker thresholds have a marked genetic contribution, in contrast with rod thresholds and adaptive processes, which are influenced more by environmental factors over a lifetime. CONCLUSIONS Genes and the environment contribute differently to important neuronal processes in the retina and the role they may play in the decline in visual function as we age. Consequently, retinal structures involved in rod thresholds and adaptive processes may be responsive to appropriate environmental manipulation. Because the functions tested are commonly impaired in the early stages of age-related macular degeneration, which is known to have a multifactorial etiology, this study supports the view that pathogenic pathways early in the disease may be altered by appropriate environmental intervention. FINANCIAL DISCLOSURE(S) The authors have no proprietary or commercial interest in any materials discussed in this article.


Investigative Ophthalmology & Visual Science | 2013

Static and flicker perimetry in age-related macular degeneration.

Chi D. Luu; Peter N. Dimitrov; Zhichao Wu; Lauren N. Ayton; Galina Makeyeva; K. Z. Aung; Mary Varsamidis; Luba Robman; Algis J. Vingrys; Robyn H. Guymer

PURPOSE The relationship between clinical severity of age-related macular degeneration (AMD) and macular function has not been well established. In this study, we investigated the correlation between clinical severity and functional deficits as detected by static and flicker perimetry. METHODS This cross-sectional study consisted of 279 AMD subjects and 24 control participants. AMD subjects were allocated into 1 of 10 AMD severity groups depending on the status of the designated study eye and the fellow eye, as assessed by color fundus photographs. Visual acuity, and static and flicker perimetry were tested on one eye during the same session. The geometric means, SDs, and percentage of abnormal eyes of static and flicker sensitivity of each AMD severity group were determined and compared. RESULTS The pattern of change in sensitivity and percentage of abnormal eyes for static perimetry across all AMD severity groups were similar to flicker perimetry. Eyes with drusen > 125 μm (P[static] = 0.018, P[flicker] = 0.024), drusenoid epithelial detachment (P[static and flicker] < 0.001) and noncentral geographic atrophy (GA; P[static and flicker] < 0.001) had significant reductions in static and flicker sensitivities compared to normal eyes. Static (β-coefficient -1.59, 95% confidence interval [CI] -4.78-1.60) and flicker (β-coefficient -1.29, 95% CI -4.66-2.08) sensitivities declined at a similar rate in eyes that showed clinical signs of progression. CONCLUSIONS Static and flicker perimetry were affected similarly across the spectrum of AMD severity, and methods appeared to be valid techniques for assessing retinal sensitivity in AMD once drusen > 125 μm are present, but before the development of late AMD.


Investigative Ophthalmology & Visual Science | 2014

Assessing Residual Visual Function in Severe Vision Loss

Lauren N. Ayton; Nicholas V. Apollo; Mary Varsamidis; Peter N. Dimitrov; Robyn H. Guymer; Chi D. Luu

PURPOSE Vision restoration is a fast-approaching reality for some people with profound vision loss. In order to reliably determine treatment efficacy, accurate assessment of baseline residual visual function is critical. The purpose of this study was to compare residual function as detected on Goldman visual field (GVF) and full-field ERG (ffERG), and correlate with the remaining photoreceptor layer as determined by spectral-domain optical coherence tomography (SD-OCT), in subjects with severe vision loss. METHODS Fifty-four subjects with advanced retinitis pigmentosa and no discernible signal on ffERG were included. Trace residual function was assessed using discrete Fourier transform (DFT) analysis of the 30-Hz flicker ffERG and the percentage of remaining GVF. The horizontal extent of the outer nuclear layer (ONL) on SD-OCT was assessed. RESULTS Thirty percent of the study eyes had a 30-Hz flicker response after DFT analysis of the ffERG, and 57% had a measurable GVF. Thirty-five percent had a visible ONL on SD-OCT. There was no significant correlation between the magnitude of the 30-Hz flicker response and the percentage of remaining GVF (r = 0.172, P = 0.213) or the extent of remaining central photoreceptors (r = 0.258, P = 0.06). Only 17% of the eyes had all three parameters detected. CONCLUSIONS Discrete Fourier transform analysis of the 30Hz-flicker ffERG response and GVF can detect trace residual function. Evidence of this residual function is not always supported by the structural correlate of a measurable ONL. Our findings highlight the importance of completing a multimodal assessment to accurately define the important parameters of retinal structure and function in people with profound vision loss.

Collaboration


Dive into the Mary Varsamidis's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Chi D. Luu

University of Melbourne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

K. Z. Aung

University of Melbourne

View shared research outputs
Top Co-Authors

Avatar

Lyndell Lim

University of Melbourne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

L. Robman

University of Melbourne

View shared research outputs
Researchain Logo
Decentralizing Knowledge