Publication


Featured researches published by Masao Imaizumi.


NeuroImage | 2008

Kinetic Analysis in Healthy Humans of a Novel Positron Emission Tomography Radioligand to Image the Peripheral Benzodiazepine Receptor, a Potential Biomarker for Inflammation

Masahiro Fujita; Masao Imaizumi; Sami S. Zoghbi; Yota Fujimura; Amanda G. Farris; Tetsuya Suhara; Jinsoo Hong; Victor W. Pike; Robert B. Innis

The peripheral benzodiazepine receptor (PBR) is upregulated on activated microglia and macrophages and thereby is a useful biomarker of inflammation. We developed a novel PET radioligand, [(11)C]PBR28, that was able to image and quantify PBRs in healthy monkeys and in a rat model of stroke. The objective of this study was to evaluate the ability of [(11)C]PBR28 to quantify PBRs in brain of healthy human subjects. Twelve subjects had PET scans of 120 to 180 min duration as well as serial sampling of arterial plasma to measure the concentration of unchanged parent radioligand. One- and two-tissue compartmental analyses were performed. To obtain stable estimates of distribution volume, which is a summation of B(max)/K(D) and nondisplaceable activity, 90 min of brain imaging was required. Distribution volumes in human were only approximately 5% of those in monkey. This comparatively low amount of receptor binding required a two-rather than a one-compartment model, suggesting that nonspecific binding was a sizeable percentage compared to specific binding. The time-activity curves in two of the twelve subjects appeared as if they had no PBR binding-i.e., rapid peak of uptake and fast washout from brain. The cause(s) of these unusual findings are unknown, but both subjects were also found to lack binding to PBRs in peripheral organs such as lung and kidney. In conclusion, with the exception of those subjects who appeared to have no PBR binding, [(11)C]PBR28 is a promising ligand to quantify PBRs and localize inflammation associated with increased densities of PBRs.


Physics in Medicine and Biology | 2010

Development of a Si-PM-based high-resolution PET system for small animals

Seiichi Yamamoto; Masao Imaizumi; Tadashi Watabe; Hiroshi Watabe; Yasukazu Kanai; Eku Shimosegawa; Jun Hatazawa

A Geiger-mode avalanche photodiode (Si-PM) is a promising photodetector for PET, especially for use in a magnetic resonance imaging (MRI) system, because it has high gain and is less sensitive to a static magnetic field. We developed a Si-PM-based depth-of-interaction (DOI) PET system for small animals. Hamamatsu 4 × 4 Si-PM arrays (S11065-025P) were used for its detector blocks. Two types of LGSO scintillator of 0.75 mol% Ce (decay time: ∼45 ns; 1.1 mm × 1.2 mm × 5 mm) and 0.025 mol% Ce (decay time: ∼31 ns; 1.1 mm × 1.2 mm × 6 mm) were optically coupled in the DOI direction to form a DOI detector, arranged in a 11 × 9 matrix, and optically coupled to the Si-PM array. Pulse shape analysis was used for the DOI detection of these two types of LGSOs. Sixteen detector blocks were arranged in a 68 mm diameter ring to form the PET system. Spatial resolution was 1.6 mm FWHM and sensitivity was 0.6% at the center of the field of view. High-resolution mouse and rat images were successfully obtained using the PET system. We confirmed that the developed Si-PM-based PET system is promising for molecular imaging research.


Physics in Medicine and Biology | 2011

Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/MRI system

Seiichi Yamamoto; Hiroshi Watabe; Yasukazu Kanai; Masaaki Aoki; Eiji Sugiyama; Tadashi Watabe; Masao Imaizumi; Eku Shimosegawa; Jun Hatazawa

The silicon-photomultiplier (Si-PM) is a promising photodetector, especially for integrated PET/MRI systems, due to its small size, high gain, and low sensitivity to static magnetic fields. The major problem using a Si-PM-based PET system within the MRI system is the interference between the PET and MRI units. We measured the interference by combining a Si-PM-based PET system with a permanent-magnet MRI system. When the RF signal-induced pulse height exceeded the lower energy threshold level of the PET system, interference between the Si-PM-based PET system and MRI system was detected. The prompt as well as the delayed coincidence count rates of the Si-PM-based PET system increased significantly. These noise counts produced severe artifacts on the reconstructed images of the Si-PM-based PET system. In terms of the effect of the Si-PM-based PET system on the MRI system, although no susceptibility artifact was observed on the MR images, electronic noise from the PET detector ring was detected by the RF coil and reduced the signal-to-noise ratio (S/N) of the MR images. The S/N degradation of the MR images was reduced when the distance between the RF coil and the Si-PM-based PET system was increased. We conclude that reducing the interference between the PET and MRI systems is essential for achieving the optimum performance of integrated Si-PM PET/MRI systems.


Atherosclerosis | 2008

Increased peripheral benzodiazepine receptors in arterial plaque of patients with atherosclerosis: An autoradiographic study with [3H]PK 11195

Yota Fujimura; Paul M. Hwang; Hugh H. Trout; Louis Kozloff; Masao Imaizumi; Robert B. Innis; Masahiro Fujita

Inflammation in atherosclerotic plaques makes them unstable and can cause thrombosis. Therefore, it is important to detect macrophage activity for clinical management of atherosclerosis. Peripheral benzodiazepine receptor (PBR) is expressed in various tissue and organs including macrophages. In this study, we tested whether inflammation characterized by macrophage infiltration can be detected by PBR binding. Six patients diagnosed as carotid atherosclerosis underwent endarterectomy. Using the fresh frozen sections, presence of PBRs and macrophages was examined by in vitro autoradiography using [(3)H]PK 11195 and immunohistochemical staining of CD68, respectively. All sections showed specific binding of [(3)H]PK 11195, and the staining with CD68 indicating macrophage infiltration. Density and distribution of PBR detected by [(3)H]PK 11195 autoradiography were consistent with those of the immunohistochemical staining. In conclusion, this study demonstrated that macrophage and inflammatory activity in atherosclerotic plaque can be imaged specifically by the binding of PBR indicating future application of PET imaging for PBR.


Stroke | 2002

Detection of Misery Perfusion With Split-Dose 123I-Iodoamphetamine Single-Photon Emission Computed Tomography in Patients With Carotid Occlusive Diseases

Masao Imaizumi; Kazuo Kitagawa; Kazuo Hashikawa; Naohiko Oku; Tadamasa Teratani; Masashi Takasawa; Takuya Yoshikawa; Piao Rishu; Toshiho Ohtsuki; Masatsugu Hori; Masayasu Matsumoto; Tsunehiko Nishimura

Background and Purpose— Patients with carotid occlusive disease and stage 2 cerebral hemodynamic failure, characterized by an increased oxygen extraction fraction (OEF) as measured by positron emission tomography (PET) and otherwise known as misery perfusion, have a high risk of cerebral ischemia and subsequent stroke. In clinical practice, the detection of patients with misery perfusion through the use of widely available, noninvasive, and cost-effective modalities such as single-photon emission computed tomography (SPECT) is extremely important. Methods— We evaluated the relationships between the regional hemodynamic status of cerebral circulation, measured with split-dose [123I]N-isopropyl-p-iodoamphetamine SPECT (123I-IMP SPECT) and an acetazolamide challenge, and hemodynamic parameters, including OEF measured with PET, in 27 patients with both unilateral and bilateral carotid occlusive diseases. Results— A significant negative correlation was found between the SPECT-measured cerebrovascular reserve after acetazolamide administration and both the PET-measured OEF and cerebral blood volume. Neither the cerebrovascular reserve nor the cerebral blood flow index, when expressed as a SPECT-measured cerebrum-to-cerebellum ratio, was useful for detecting lesions with an elevated OEF. However, a combination of the cerebrovascular reserve and cerebral blood flow index showed high sensitivity, specificity, and positive predictive value for the detection of misery perfusion. Conclusions— Our study suggests that split-dose 123I-IMP SPECT with an acetazolamide challenge could be useful for screening patients with misery perfusion in carotid occlusive diseases.


Annals of Nuclear Medicine | 2004

Cerebral hemodynamics and metabolism in adult moyamoya disease: Comparison of angiographic collateral circulation

Rishu Piao; Naohiko Oku; Kazuo Kitagawa; Masao Imaizumi; Kohji Matsushita; Takuya Yoshikawa; Masashi Takasawa; Yasuhiro Osaki; Yasuyuki Kimura; Katsufumi Kajimoto; Masatsugu Hori; Jun Hatazawa

PurposeThe extent of the hemodynamic and metabolic impairments in adult patients with moyamoya disease is still controversial. The aim of the present study was to evaluate the hemodynamic and metabolic status in relation to the development of basal moyamoya vessels (BMVs).MethodsThe cerebral blood flow (CBF), cerebral metabolic rate of oxygen (CMRO2), oxygen extraction fraction (OEF), and cerebral blood volume (CBV) were measured using PET in ten patients with ischemic adult moyamoya disease (mean age, 36.6 years) and six age-matched normal controls (mean age, 33.3 years). The cerebrovascular reserve (CVR) after acetazolamide (ACZ) loading was also estimated using iodine-123N- isopropyl-p-iodo amphetamine single photon emission computed tomography (123I-IMP SPECT).ResultsBased on the angiographic findings, eleven cerebral hemispheres with well-developed BMV (extensive BMV hemispheres) and nine cerebral hemispheres with diminished BMV (diminished BMV hemispheres) were identified. The main routes of collateral circulation in extensive BMV hemispheres were BMVs and leptomeningeal anastomoses. On the other hand, in diminished BMV hemispheres, transdural anastomosis was predominant, and leptomeningeal anastomoses were less developed. In cortices distal to the occluded internal carotid artery, the extensive BMV hemispheres exhibited a significantly lower CBF, CMRO2, CBF/CBV, and CVR (p < 0.05) and a significantly higher CBV and OEF than in diminished BMV hemispheres and controls (p < 0.05). Except for the CBF in the white matter, the mean hemodynamic and metabolic parameters of the diminished BMV hemispheres were not significantly different from those of the controls.ConclusionThe extensive development of basal moyamoya vessels is a sign of severe hemodynamic impairment in adult patients with ischemic moyamoya disease. The results may not apply to adults with hemorrhagic onset.


Physics in Medicine and Biology | 2012

Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system

Seiichi Yamamoto; Tadashi Watabe; Hiroshi Watabe; Masaaki Aoki; Eiji Sugiyama; Masao Imaizumi; Yasukazu Kanai; Eku Shimosegawa; Jun Hatazawa

The silicon photomultiplier (Si-PM) is a promising photo-detector for PET for use in magnetic resonance imaging (MRI) systems because it has high gain and is insensitive to static magnetic fields. Recently we developed a Si-PM-based depth-of-interaction PET system for small animals and performed simultaneous measurements by combining the Si-PM-based PET and the 0.15 T permanent MRI to test the interferences between the Si-PM-based PET and an MRI. When the Si-PM was inside the MRI and installed around the radio frequency (RF) coil of the MRI, significant noise from the RF sequence of the MRI was observed in the analog signals of the PET detectors. However, we did not observe any artifacts in the PET images; fluctuation increased in the count rate of the Si-PM-based PET system. On the MRI side, there was significant degradation of the signal-to-noise ratio (S/N) in the MRI images compared with those without PET. By applying noise reduction procedures, the degradation of the S/N was reduced. With this condition, simultaneous measurements of a rat brain using a Si-PM-based PET and an MRI were made with some degradation in the MRI images. We conclude that simultaneous measurements are possible using Si-PM-based PET and MRI.


Physics in Medicine and Biology | 2011

A temperature-dependent gain control system for improving the stability of Si-PM-based PET systems

Seiichi Yamamoto; Junkichi Satomi; Tadashi Watabe; Hiroshi Watabe; Yasukazu Kanai; Masao Imaizumi; Eku Shimosegawa; Jun Hatazawa

The silicon-photomultiplier (Si-PM) is a promising photodetector for the development of new PET systems due to its small size, high gain and relatively low sensitivity to the static magnetic field. One drawback of the Si-PM is that it has significant temperature-dependent gain that poses a problem for the stability of the Si-PM-based PET system. To reduce this problem, we developed and tested a temperature-dependent gain control system for the Si-PM-based PET system. The system consists of a thermometer, analog-to-digital converter, personal computer, digital-to-analog converter and variable gain amplifiers in the weight summing board of the PET system. Temperature characteristics of the Si-PM array are measured and the calculated correction factor is sent to the variable gain amplifier. Without this correction, the temperature-dependent peak channel shifts of the block detector were -55% from 20 °C to 35 °C. With the correction, the peak channel variations were corrected within ±8%. The coincidence count rate of the Si-PM-based PET system was measured using a Na-22 point source while monitoring the room temperature. Without the correction, the count rate inversely changed with the room temperature by 10% for 1.5° C temperature changes. With the correction, the count rate variation was reduced to within 3.7%. These results indicate that the developed temperature-dependent gain control system can contribute to improving the stability of Si-PM-based PET systems.


Japanese Journal of Radiology | 2010

Diagnostic performance of fluorodeoxyglucose positron emission tomography/magnetic resonance imaging fusion images of gynecological malignant tumors: comparison with positron emission tomography/computed tomography.

Kazuya Nakajo; Mitsuaki Tatsumi; Atsuo Inoue; Kayako Isohashi; Ichiro Higuchi; Hiroki Kato; Masao Imaizumi; Takayuki Enomoto; Eku Shimosegawa; Tadashi Kimura; Jun Hatazawa

PurposeWe compared the diagnostic accuracy of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) and PET/magnetic resonance imaging (MRI) fusion images for gynecological malignancies.Materials and methodsA total of 31 patients with gynecological malignancies were enrolled. FDG-PET images were fused to CT, T1- and T2-weighted images (T1WI, T2WI). PET-MRI fusion was performed semiautomatically. We performed three types of evaluation to demonstrate the usefulness of PET/MRI fusion images in comparison with that of inline PET/CT as follows: depiction of the uterus and the ovarian lesions on CT or MRI mapping images (first evaluation); additional information for lesion localization with PET and mapping images (second evaluation); and the image quality of fusion on interpretation (third evaluation).ResultsFor the first evaluation, the score for T2WI (4.68 ± 0.65) was significantly higher than that for CT (3.54 ± 1.02) or T1WI (3.71 ± 0.97) (P < 0.01). For the second evaluation, the scores for the localization of FDG accumulation showing that T2WI (2.74 ± 0.57) provided significantly more additional information for the identification of anatomical sites of FDG accumulation than did CT (2.06 ± 0.68) or T1WI (2.23 ± 0.61) (P < 0.01). For the third evaluation, the three-point rating scale for the patient group as a whole demonstrated that PET/T2WI (2.72 ± 0.54) localized the lesion significantly more convincingly than PET/CT (2.23 ± 0.50) or PET/T1WI (2.29 ± 0.53) (P < 0.01).ConclusionPET/T2WI fusion images are superior for the detection and localization of gynecological malignancies.


Physics in Medicine and Biology | 2011

Development of a high-resolution Si-PM-based gamma camera system.

Seiichi Yamamoto; Hiroshi Watabe; Yasukazu Kanai; Masao Imaizumi; Tadashi Watabe; Eku Shimosegawa; Jun Hatazawa

A silicon photomultiplier (Si-PM) is a promising photodetector for PET, especially for PET/MRI combined systems, due to its high gain, small size, and lower sensitivity to static magnetic fields. However, these properties are also promising for gamma camera systems for single-photon imaging. We developed an ultra-high-resolution Si-PM-based compact gamma camera system for small animals. Y(2)SiO(5):Ce (YSO) was selected as scintillators because of its high light output and no natural radioactivity. The gamma camera consists of 0.6 mm × 0.6 mm × 6 mm YSO pixels combined with a 0.1 mm thick reflector to form a 17 × 17 matrix that was optically coupled to a Si-PM array (Hamamatsu multi-pixel photon counter S11064-050P) with a 2 mm thick light guide. The YSO block size was 12 mm × 12 mm. The YSO gamma camera was encased in a 5 mm thick gamma shield, and a parallel hole collimator was mounted in front of the camera (0.5 mm hole, 0.7 mm separation, 5 mm thick). The two-dimensional distribution for the Co-57 gamma photons (122 keV) was almost resolved. The energy resolution was 24.4% full-width at half-maximum (FWHM) for the Co-57 gamma photons. The spatial resolution at 1.5 mm from the collimator surface was 1.25 mm FWHM measured using a 1 mm diameter Co-57 point source. Phantom and small animal images were successfully obtained. We conclude that a Si-PM-based gamma camera is promising for molecular imaging research.

Collaboration


Dive into the Masao Imaizumi's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge