Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Masato Fukunaga is active.

Publication


Featured researches published by Masato Fukunaga.


Heart Rhythm | 2015

Importance of nonpulmonary vein foci in catheter ablation for paroxysmal atrial fibrillation.

Kentaro Hayashi; Yoshimori An; Michio Nagashima; Kenichi Hiroshima; Masatsugu Ohe; Yu Makihara; Kennosuke Yamashita; Schoichiro Yamazato; Masato Fukunaga; Koichiro Sonoda; Kenji Ando; Masahiko Goya

BACKGROUND Pulmonary vein (PV) isolation is an established treatment strategy for paroxysmal atrial fibrillation (PAF). However, the recurrence rate of PAF is 8% to 37%, despite repeated procedures, and the catheter ablation strategy for PAF with non-PV foci is unclear. OBJECTIVE The purpose of this study was to assess the PAF ablation strategy for non-PV foci. METHODS The study included 304 consecutive patients undergoing PAF ablation (209 males, age 63.0 ± 10.4 years) divided into 3 groups: group 1 (245 patients) with no inducible non-PV foci; group 2 (34 patients) with atrial fibrillation (AF) originating from non-PV foci and all the foci successfully ablated; and group 3 (25 patients) with AF originating from non-PV triggers, but without all foci being ablated or with persistently inducible AF. RESULTS Mean follow-up period was 26.9 ± 11.8 months, and AF recurrence rates since the last procedure were 9.8%, 8.8%, and 68.0% in groups 1, 2, and 3, respectively. There was no statistically significant difference in recurrence rate between groups 1 and 2 (P = .89); however, there were statistically significant differences between groups 3 and 1 (P <.0001) and groups 3 and 2 (P <.0001). The patients in group 2 had an AF-free outcome to equivalent to those who had PV foci in group 1 (P = .83). CONCLUSION Success rates can be improved for PAF ablation if non-PV foci are detected and eliminated.


Journal of Arrhythmia | 2015

Long-term outcomes of catheter ablation of ventricular tachycardia in patients with structural heart disease

Masahiko Goya; Masato Fukunaga; Kenichi Hiroshima; Kentaro Hayashi; Yu Makihara; Michio Nagashima; Yoshimori An; Seiji Ohe; Kennosuke Yamashita; Kenji Ando; Hiroyoshi Yokoi; Masashi Iwabuchi; Kouji Katayama; Tomoaki Ito; Harushi Niu

Catheter ablation of ventricular tachycardia (VT) is feasible. However, the long‐term outcomes for different underlying diseases have not been well defined.


Circulation | 2016

Impact of Catheter Ablation for Paroxysmal Atrial Fibrillation in Patients With Sick Sinus Syndrome – Important Role of Non-Pulmonary Vein Foci –

Kentaro Hayashi; Masato Fukunaga; Kyohei Yamaji; Yoshimori An; Michio Nagashima; Kenichi Hiroshima; Masatsugu Ohe; Yu Makihara; Kennosuke Yamashita; Kenji Ando; Masashi Iwabuchi; Masahiko Goya

BACKGROUND The clinical efficacy of catheter ablation (CA) for paroxysmal atrial fibrillation (PAF) in patients with sick sinus syndrome (SSS) and the mechanism and predictors of recurrence are not yet completely elucidated. METHODSANDRESULTS Of 963 consecutive patients who underwent PAF ablation during the study period, a total of 108 patients with SSS (SSS group) and 108 matched controls without SSS (non-SSS group) were followed up. During the follow-up period (mean, 32.8±17.5 months), the SSS group had significantly higher AF recurrence rate since the last procedure than the non-SSS group (26.9% vs. 12.0%; P=0.02). The SSS group had significantly higher prevalence of non-pulmonary vein (non-PV) foci than the non-SSS group (25.9% vs. 13.9%; P=0.027). On multivariate analysis congestive heart failure (HR, 13.7; 95% CI: 1.57-119; P=0.02) and non-PV foci (HR, 5.75; 95% CI: 1.69-19.6; P=0.005) were independent predictors of recurrence following CA in the SSS group. In the SSS group, 88 patients had bradycardia-tachycardia syndrome without prior permanent pacemaker implantation. Of these, 6 required pacemaker implantation because of AF and sinus pause recurrence. CONCLUSIONS Patients with SSS are at higher risk of AF recurrence after CA. Non-PV foci are associated with AF recurrence following PAF with SSS.


Journal of Infection and Chemotherapy | 2016

Implantable cardioverter defibrillator infection due to Mycobacterium mageritense

Masato Fukunaga; Masahiko Goya; Midori Ogawa; Kazumasa Fukuda; Hatsumi Taniguchi; Kenji Ando; Masashi Iwabuchi; Hiroaki Miyazaki

Rapidly growing non-tuberculous mycobacteria (RGM) are usually detected in blood cultures after 4-5 days of incubation, so it is important to differentiate RGM from contamination of commensal organisms on human skin. We report an unusual case of Mycobacterium mageritense bacteremia and infection of an implantable cardioverter defibrillator originally misidentified as Corynebacterium spp. or Nocardia spp. in gram-stained smears. 16S rRNA gene sequencing had utility in the definitive identification of isolates. We should be aware that RGM infection may exist in repeated implantable device infections.


Journal of Arrhythmia | 2016

Lead extractions in patients with cardiac implantable electronic device infections: Single center experience.

Masahiko Goya; Michio Nagashima; Kenichi Hiroshima; Kentaro Hayashi; Yu Makihara; Masato Fukunaga; Yoshimori An; Masatsugu Ohe; So-ichiro Yamazato; Koichiro Sonoda; Kennosuke Yamashita; Kouji Katayama; Tomoaki Ito; Harushi Niu; Kenji Ando; Hiroyoshi Yokoi; Masashi Iwabuchi

Lead extraction using laser sheaths is performed mainly for cardiac implantable electronic device (CIED) infections. However, there are few reports concerning the management of CIED infections in Japan.


Journal of Cardiology | 2017

Identification of causative organism in cardiac implantable electronic device infections

Masato Fukunaga; Masahiko Goya; Michio Nagashima; Kenichi Hiroshima; Takashi Yamada; Yoshimori An; Kentaro Hayashi; Yu Makihara; Masatsugu Ohe; Kei Ichihashi; Morimasa Ohtsuka; Hiroaki Miyazaki; Kenji Ando

BACKGROUND The causative organism in cardiovascular implantable electronic device (CIED) infection is usually diagnosed with the cultures from blood, removed leads, and/or infected pocket material. The cultured organism, however, is sometimes different among these samples. METHODS Two hundred sixty patients with CIED infection, who underwent lead extraction between April 2005 and December 2014, were analyzed. More than two blood culture sets, all the extracted leads, and swab culture of the pocket were sent to the laboratory for culture. Among the patients all of whose microbiological examinations were available, we analyzed the causative organism defined as the species detected in at least two different sites. RESULTS All the culture results were available in the 208 patients, showing 69 systemic infections (including 30 cases of infectious endocarditis) and 139 local infections. Blood culture, lead culture, and swab culture were positive in 57 (27%), 169 (81%), and 152 (73%), respectively. Staphylococcus aureus [37% including methicillin-resistant S. aureus (MRSA) (12%)] and coagulase-negative staphylococci (CoNS, 36%) were the most common causative organism, followed by non-staphylococci (23%), and poly-microbial infection (4%). The detection of S. aureus from pocket or removed leads rendered higher predictive value of a causative organism than that of CoNS. The detection of Gram-negative bacteria, fungi, and mycobacteria indicated that it was most likely a causative organism. Gram-positive bacteria excluding Staphylococcus, such as Corynebacterium spp., tended to coexist as a benign organism. CONCLUSIONS The causative organism is mostly S. aureus and CoNS. Detection of S. aureus or Gram-negative bacteria means that it is more likely a causative organism.


Journal of Arrhythmia | 2017

Mortality and predictors of appropriate implantable cardioverter defibrillator therapy in Japanese patients with Multicenter Automatic Defibrillator Implantation Trial II criteria

Yoshimori An; Kenji Ando; Yoshimitsu Soga; Akihiro Nomura; Michio Nagashima; Kentaro Hayashi; Yu Makihara; Masato Fukunaga; Kenichi Hiroshima; Masakiyo Nobuyoshi; Masahiko Goya

Data regarding long‐term mortality and factors influencing appropriate therapies in Japanese patients with implantable cardioverter defibrillators (ICD), who satisfy the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) criteria for primary prevention, remain scarce.


Journal of Arrhythmia | 2016

Impact of catheter ablation of ventricular tachycardia in patients with prior myocardial infarctions

Masato Fukunaga; Masahiko Goya; Kenichi Hiroshima; Kentaro Hayashi; Masatsugu Ohe; Yu Makihara; Michio Nagashima; Yoshimori An; Shinichi Shirai; Kenji Ando; Hiroyoshi Yokoi; Masashi Iwabuchi

Catheter ablation can reduce episodes of ventricular tachycardia (VT) after myocardial infarction (MI). However, the optimal endpoint of the ablation procedure remains unclear.


Circulation | 2017

Efficacy of Intensive Radiofrequency Energy Delivery to the Localized Dense Scar Area in Post-Infarction Ventricular Tachycardia Ablation ― A Comparative Study With Standard Strategy Targeting the Infarcted Border Zone ―

Kenji Kuroki; Akihiko Nogami; Kentaro Yoshida; Masahiko Goya; Masato Fukunaga; Kazuaki Kaitani; Naoaki Onishi; Takanao Mine; Takashi Koyama; Masayuki Igawa; Takeshi Machino; Hiro Yamasaki; Dongzhu Xu; Miyako Igarashi; Nobuyuki Murakoshi; Yukio Sekiguchi; Kazutaka Aonuma

BACKGROUND Several reports have demonstrated the importance of severely low voltage areas as arrhythmogenic substrates of ventricular tachycardia (VT). However, a comparative study of dense scar-targeted and infarcted border zone-targeted strategies has not been reported.Methods and Results:We divided 109 consecutive patients with VT post-infarction from 6 centers into 2 groups according to the ablation strategy used: dense scar-targeted ablation (DS ablation, 48%) or border zone-targeted ablation (BZ ablation, 52%). During DS ablation, we attempted to identify VT isthmuses in the dense scar areas (≤0.6 mV) using detailed pace mapping, and linear ablation lesions were applied mainly to those areas. During BZ ablation, linear ablation of standard low voltage areas (0.5-1.5 mV) was performed along with good pace map sites of the clinical VT. Acute success was defined as complete success (no VTs inducible) or partial success (clinical VT was noninducible). The acute complete success rate was significantly higher for DS ablation than for BZ ablation (62% vs. 42%, P=0.043). During a median follow-up of 37 months, the VT-free survival rate was significantly higher for DS ablation than for BZ ablation (80% vs. 58% at 48 months; log-rank P=0.038). CONCLUSIONS DS ablation may be a more effective therapy for post-infarction VT than BZ ablation in terms of the acute complete success rate and long-term follow-up.


Journal of Cardiology | 2018

Transvenous extraction of advisory implantable cardioverter defibrillator leads with a relatively long implant duration

Masahiko Goya; Michio Nagashima; Kenichi Hiroshima; Kentaro Hayashi; Yu Makihara; Masato Fukunaga; Yoshimori An; Masatsugu Ohe; Takeshi Sasaki; Shinya Shiohira; Yasuhiro Shirai; Mihoko Kawabata; Kenji Ando; Mitsuaki Isobe; Kenzo Hirao

BACKGROUND Optimal management of advisory implantable cardioverter defibrillator (ICD) leads has not been established. Several studies were reported concerning the lead extraction of advisory ICD leads, but the implant duration of those studies was short. We estimated the efficacy of lead extractions of advisory ICD leads with a relatively longer duration in Japanese patients. METHODS We retrospectively analyzed 28 patients who underwent a lead extraction at Kokura Memorial Hospital and Tokyo Medical and Dental University Hospital [Fidelis (Medtronic, Minneapolis, MN, USA): n=19, Riata (St. Jude Medical, Sylmar, CA, USA): n=8, Isoline (SORIN CRM SAS, Clamart, France): n=1]. The mean implant duration was 63.3±19.3 months. The indications were device related infections in 3, electrical lead failures in 18, electrical lead failures and venous obstructions in 3, and prophylactic reasons in 4 patients. Inappropriate shocks because of electrical lead failures were observed in 9 patients. RESULTS Complete removals were achieved of all 28 advisory leads. In 23 out of 28 patients, new ICD leads were implanted during the same procedure. In one patient, open chest surgery was performed for a hemothorax that occurred during a new ICD lead implantation just after successfully removing the advisory ICD lead. There were no other major or minor complications. CONCLUSION Transvenous extractions of advisory ICD leads with relatively long implant duration were performed with a high success rate and low complication and mortality rate in Japanese patients.

Collaboration


Dive into the Masato Fukunaga's collaboration.

Top Co-Authors

Avatar

Kenichi Hiroshima

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar

Michio Nagashima

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar

Kenji Ando

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar

Yoshimori An

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar

Kentaro Hayashi

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar

Masahiko Goya

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar

Yu Makihara

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar

J. Morita

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar

Masatsugu Ohe

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar

S. Tohoku

Memorial Hospital of South Bend

View shared research outputs
Researchain Logo
Decentralizing Knowledge