Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Mateusz Puslecki is active.

Publication


Featured researches published by Mateusz Puslecki.


Disaster and Emergency Medicine Journal | 2017

High-fidelity simulation — the first DCD-ECMO procedure in Poland

Mateusz Puslecki; Marcin Ligowski; Marek Dabrowski; Maciej Sip; Sebastian Stefaniak; Tomasz Klosiewicz; Lukasz Gasiorowski; Marek Karczewski; Tomasz Małkiewicz; Malgorzata Ladzinska; Marcin Zieliński; Aleksander Pawlak; Agata Dabrowska; Piotr Ziemak; Bartłomiej Perek; Marcin Misterski; Sławomir Katarzyński; Piotr Buczkowski; Wojciech Telec; Ilona Kiel-Puslecka; Michał Kiel; Michael Czekajlo; Marek Jemielity

Mateusz Puslecki, Marcin Ligowski, Marek Dabrowski, Maciej Sip, Sebastian Stefaniak, Tomasz Klosiewicz, Lukasz Gasiorowski, Marek Karczewski, Tomasz Malkiewicz, Malgorzata Ladzinska, Marcin Zielinski, Aleksander Pawlak, Agata Dabrowska, Piotr Ziemak, Bartlomiej Perek, Marcin Misterski, Slawomir Katarzynski, Piotr Buczkowski, Wojciech Telec, Ilona Kiel-Puslecka, Michal Kiel, Michael Czekajlo, Marek Jemielity Poznan University of Medical Sciences, Department of Cardiac Surgery and Transplantology, Clinical Hospital SKPP, Poznan, Poland Poznan University of Medical Sciences, Department of Rescue and Disaster Medicine, Poznan, Poland Polish Society of Medical Simulation, Poland Poznan University of Medical Sciences, Center for Medical Simulation, Poznan, Poland Poznan University of Medical Sciences, Department of Intensive Care and Pain Treatment, Poznan, Poland Poznan University of Medical Sciences, Department of Transplantology, General, Vascular and Plastic Surgery, Poznan, Poland Poznan University of Medical Sciences, Department of Anesthesiology and Intensive Care, Clinical Hospital H. Święcickiego, Poznan, Poland Voivodeship Emergency Medical Services, Poznan, Poland Poznan University of Medical Sciences, Department of Palliative Medicine, Poznan, Poland ZF RTW, Częstochowa, Poland Hunter Holmes McGuire VA Medical Center, Department of Surgery, Richmond, United States of America Lublin Medical University, Lublin, Poland


Journal of Thoracic Disease | 2018

An innovative panel to assess endothelial integrity of pedicled and skeletonized internal thoracic artery used as aortocoronary bypass graft: a randomized comparative histologic and immunohistochemical study

Mateusz Puslecki; Piotr Buczkowski; Michał Nowicki; Patrycja Sujka-Kordowska; Marcin Ligowski; Marcin Misterski; Sebastian Stefaniak; Marek Dąbrowski; Agata Dabrowska; Michal Bocianski; Lukasz Szarpak; Kurt Ruetzler; Marek Jemielity; Bartłomiej Perek

Background Optimal preservation of endothelial integrity of the vessels used as aortocoronary grafts is a crucial determinant of long-term clinical success of coronary artery bypass grafting (CABG). The purpose of this study was to evaluate an impact of two common techniques to harvest left internal thoracic artery (LITA) on endothelial integrity. Methods One hundred twenty consecutive patients (84 males and 36 females) with a mean age of 64.9±8.8 years undergoing CABG were randomized to receive pedicled (group P; n=60) or skeletonized (group S; n=60) LITA grafts. During surgery LITA was harvested by the same experienced cardiac surgeon. The most peripheral surplus segments of LITA were obtained and then analysed histologically under light microscope. Additionally, endothelial expression of CD31, CD34, CD133 and nitric oxide synthase (eNOS) were evaluated by means of immunohistochemistry. Results In both groups, no cases of major arterial wall damage such as disruption, dissection, thrombosis or subadventitial hematoma were noted on LITA cross sections. Immunohistochemical assessment of protein expression revealed no differences in endothelial expression of CD133, CD34 antigens (markers of regeneration potential) and eNOS (indicating preserved functional integrity) between studied groups. Contrary to them, endothelial immunoreactivity of CD31, a marker of the morphological integrity of the endothelium, was revealed to be stronger in group P. Conclusions The skeletonized method of LITA harvesting may be associated with worse preservation of morphological integrity of endothelium but without compromising functional integrity and potential for tissue regeneration.


Heart and Vessels | 2018

Vascular restenosis in coronary artery bypass grafting might be associated with VEGF-C/VEGFR-3 signaling pathway

Zuzanna Podemska-Jedrzejczak; Agnieszka Malinska; Patrycja Sujka-Kordowska; Michał Nowicki; Mateusz Puslecki; Marek Jemielity; Bartłomiej Perek

The vascular endothelial growth factor (VEGF) family of peptides and caveolins (CAVs) are reported to contribute, in early graft failure in patients, a coronary artery bypass grafting (CABG). To investigate the possible association of ultimate luminal occlusion to VEGFs and CAVs expression, a functional analysis (based on the molecular biology, bioinformatics, histology, and clinical studies) was performed. Twenty-four hundred and sixty-eight CABG patients diagnosed with multivessel stable coronary artery disease (CAD) were enrolled into prospective study and assigned to two subgroups: double- and triple-vessel CAD subjects. Distal parts of all the harvested saphenous vein (SV) and internal thoracic artery (ITA) segments were used for further tests. ITA graft failure did not differ between double-vessel and triple-vessel CAD patients. The number of SV occlusions was significantly higher in triple-vessel CAD subjects. The microarray analysis performed on SV and ITA samples obtained exclusively from triple-vessel CAD patients who developed early graft occlusion revealed 383 genes with increased and 301 genes with decreased expression in ITA samples as compared to SV grafts. This was followed by functional analysis of ‘blood vessel development’ group of genes. Average VEGF-C expression in ITA grafts was higher than in corresponding SV grafts; FLT4 expression was significantly higher in SV than in ITA transplants. VEGFR-3 and CAV3 expression demonstrated immunohistochemically in SMCs of the tunica media of SV grafts predicted their early restenosis in triple-vessel CAD patients. CAV2 protein expression in SMCs of ITA grafts indicated the risk of early graft failure both in double-vessel and triple-vessel CAD subjects.


Journal of Thoracic Disease | 2017

Post-traumatic acute thoracic aortic injury (TAI)—a single center experience

Piotr Buczkowski; Mateusz Puslecki; Sebastian Stefaniak; Robert Juszkat; Jerzy Kulesza; Bartłomiej Perek; Marcin Misterski; Tomasz Urbanowicz; Marcin Ligowski; Bartosz Zabicki; Marek Dabrowski; Lukasz Szarpak; Marek Jemielity

Background We assess the effectiveness and our experience in emergency thoracic endovascular aortic repair (TEVAR) in patients with post-traumatic acute thoracic aortic injury (TAI) and associated multiorgan trauma. TAI is a life-threatening condition. It usually results from a sudden deceleration caused by vehicle accident, a fall or some other misfortune. Techniques of endovascular aortic repair have become promising methods to treat emergent TAI. Methods Since 2007, 114 patients with thoracic aorta pathologies have been treated by TEVAR. Our study involved 15 (incl. 14 men) of them (13%) who underwent stent graft implantation for post-traumatic either aortic rupture or pseudoaneurysm. The procedural access was limited to small skin incision in one groin and percutaneous puncture of the contralateral femoral artery. We evaluated technical success, early and long-term mortality, complication rate of procedure and throughout clinical and instrumental follow-up. Results Technical success rate was 100%. All patients survived the endovascular interventions. No additional procedures or conversions to open surgery were necessary. After the operation, none of the patients had symptoms of stroke or spinal cord ischemia (SCI). No serious stent-graft-related adverse events such as endoleak, infection or migration were noted during follow-up period that ranged from 6 to 108 months. Conclusions In our department, techniques of TEVAR with stentgraft implantation have become methods of choice in treatment of traumatic TAIs since they have enabled to minimize operational risk, particularly in unstable multitrauma patients in severe clinical status. TEVAR for TAI performed in emergency settings provide favorable long-term results.


Kardiologia Polska | 2014

AED use in public places: a study of acquisition time

Wojciech Telec; Artur Baszko; Marek Dabrowski; Agata Dabrowska; Maciej Sip; Mateusz Puslecki; Tomasz Klosiewicz; Patrycja Potyrała; Witold Jurczyk; Adrian Maciejewski; Radoslaw Zalewski; Magdalena Witt; Jerzy Robert Ladny; Lukasz Szarpak

BACKGROUND Sudden cardiac arrest (SCA) is a frequent cause of death in the developed world. Early defibrillation, preferably within the first minutes of the incident, significantly increases survival rates. Accessible automated external defibrillators (AED) in public areas have been promoted for many years, and several locations are equipped with these devices. AIM The aim of the study was to assess the real-life availability of AEDs and assess possible sources of delay. METHODS The study took place in the academic towns of Poznan, Lodz, and Warsaw, Poland. The researchers who were not aware of the exact location of the AED in the selected public locations had to deliver AED therapy in simulated SCA scenarios. For the purpose of the trial, we assumed that the SCA takes place at the main entrance to the public areas equipped with an AED. RESULTS From approximately 200 locations that have AEDs, 78 sites were analysed. In most places, the AED was located on the ground floor and the median distance from the site of SCA to the nearest AED point was 15 m (interquartile range [IQR] 7-24; range: 2-163 m). The total time required to deliver the device was 96 s (IQR 52-144 s). The average time for discussion with the person responsible for the AED (security officer, staff, etc.) was 16 s (IQR 0-49). The AED was located in open access cabinets for unrestricted collection in 29 locations; in 10 cases an AED was delivered by the personnel, and in 29 cases AED utilisation required continuous personnel assistance. The mode of accessing the AED device was related to the longer discussion time (p < 0.001); however, this did not cause any significant delay in therapy (p = 0.132). The AED was clearly visible in 34 (43.6%) sites. The visibility of AED did not influence the total time of simulated AED implementation. CONCLUSIONS We conclude that the access to AED is relatively fast in public places. In the majority of assessed locations, it meets the recommended time to early defibrillation of under 3 min from the onset of the cardiac arrest; however, there are several causes for possible delays. The AED signs indicating the location of the device should be larger. AEDs should also be displayed in unrestricted areas for easy access rather than being kept under staff care or in cabinets.


Kardiologia Polska | 2014

Zastosowanie AED w miejscach publicznych: badanie czasu użycia

Wojciech Telec; Artur Baszko; Marek Dabrowski; Agata Dabrowska; Maciej Sip; Mateusz Puslecki; Tomasz Klosiewicz; Patrycja Potyrała; Witold Jurczyk; Adrian Maciejewski; Radoslaw Zalewski; Magdalena Witt; Jerzy Robert Ladny; Lukasz Szarpak

BACKGROUND Sudden cardiac arrest (SCA) is a frequent cause of death in the developed world. Early defibrillation, preferably within the first minutes of the incident, significantly increases survival rates. Accessible automated external defibrillators (AED) in public areas have been promoted for many years, and several locations are equipped with these devices. AIM The aim of the study was to assess the real-life availability of AEDs and assess possible sources of delay. METHODS The study took place in the academic towns of Poznan, Lodz, and Warsaw, Poland. The researchers who were not aware of the exact location of the AED in the selected public locations had to deliver AED therapy in simulated SCA scenarios. For the purpose of the trial, we assumed that the SCA takes place at the main entrance to the public areas equipped with an AED. RESULTS From approximately 200 locations that have AEDs, 78 sites were analysed. In most places, the AED was located on the ground floor and the median distance from the site of SCA to the nearest AED point was 15 m (interquartile range [IQR] 7-24; range: 2-163 m). The total time required to deliver the device was 96 s (IQR 52-144 s). The average time for discussion with the person responsible for the AED (security officer, staff, etc.) was 16 s (IQR 0-49). The AED was located in open access cabinets for unrestricted collection in 29 locations; in 10 cases an AED was delivered by the personnel, and in 29 cases AED utilisation required continuous personnel assistance. The mode of accessing the AED device was related to the longer discussion time (p < 0.001); however, this did not cause any significant delay in therapy (p = 0.132). The AED was clearly visible in 34 (43.6%) sites. The visibility of AED did not influence the total time of simulated AED implementation. CONCLUSIONS We conclude that the access to AED is relatively fast in public places. In the majority of assessed locations, it meets the recommended time to early defibrillation of under 3 min from the onset of the cardiac arrest; however, there are several causes for possible delays. The AED signs indicating the location of the device should be larger. AEDs should also be displayed in unrestricted areas for easy access rather than being kept under staff care or in cabinets.


Cardiovascular Journal of Africa | 2014

Closure of ruptured aneurysm of the sinus of Valsalva using a native aortic valve leaflet : online article - case report

Piotr Buczkowski; Maciej Walczak; Sebastian Stefaniak; Mateusz Puslecki; Izabela Katyńska; Marek Jemielity

We present a case of the native valve used to complete closure of a ruptured aneurysm of the sinus of Valsalva. Aneurysm of the sinus of Valsalva is rare and a non-coronary artery is affected in only 20% of cases. To close the rupture, we decided to use a non-coronary leaflet in a young patient with moderate aortic stenosis and fibrosis of the leaflets. In our opinion, use of a native non-coronary valve leaflet should be considered when making intra-operative decisions for repair of non-coronary aneurysm of the sinus of Valsalva.


Cardiovascular Journal of Africa | 2014

Closure of ruptured aneurysm of the sinus of Valsalva using a native aortic valve leaflet : case report

Piotr Buczkowski; Maciej Walczak; Sebastian Stefaniak; Mateusz Puslecki; Izabela Katyńska; Marek Jemielity

We present a case of the native valve used to complete closure of a ruptured aneurysm of the sinus of Valsalva. Aneurysm of the sinus of Valsalva is rare and a non-coronary artery is affected in only 20% of cases. To close the rupture, we decided to use a non-coronary leaflet in a young patient with moderate aortic stenosis and fibrosis of the leaflets. In our opinion, use of a native non-coronary valve leaflet should be considered when making intra-operative decisions for repair of non-coronary aneurysm of the sinus of Valsalva.


Resuscitation | 2018

Comparison of Pediatric NIO and EZ-IO intraosseous access devices during simulated resuscitation

Wojciech Wieczorek; Halla Kaminska; Jacek Smereka; Marek Dabrowski; Mateusz Puslecki; Lukasz Szarpak


Resuscitation | 2018

Can novice physicians recognize Torsades de Pointes

Lukasz Szarpak; Jacek Smereka; Jerzy Robert Ladny; Mateusz Puslecki; Michael Frass

Collaboration


Dive into the Mateusz Puslecki's collaboration.

Top Co-Authors

Avatar

Lukasz Szarpak

Medical University of Warsaw

View shared research outputs
Top Co-Authors

Avatar

Marek Dabrowski

Poznan University of Medical Sciences

View shared research outputs
Top Co-Authors

Avatar

Marek Jemielity

Poznan University of Medical Sciences

View shared research outputs
Top Co-Authors

Avatar

Agata Dabrowska

Poznan University of Medical Sciences

View shared research outputs
Top Co-Authors

Avatar

Maciej Sip

Poznan University of Medical Sciences

View shared research outputs
Top Co-Authors

Avatar

Piotr Buczkowski

Poznan University of Medical Sciences

View shared research outputs
Top Co-Authors

Avatar

Sebastian Stefaniak

Poznan University of Medical Sciences

View shared research outputs
Top Co-Authors

Avatar

Tomasz Klosiewicz

Poznan University of Medical Sciences

View shared research outputs
Top Co-Authors

Avatar

Jerzy Robert Ladny

Medical University of Białystok

View shared research outputs
Top Co-Authors

Avatar

Adrian Maciejewski

Poznan University of Medical Sciences

View shared research outputs
Researchain Logo
Decentralizing Knowledge