Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Mathias Schwarz is active.

Publication


Featured researches published by Mathias Schwarz.


Scientific Reports | 2012

Environmental toxins trigger PD-like progression via increased alpha-synuclein release from enteric neurons in mice

Francisco Pan-Montojo; Mathias Schwarz; Clemens Winkler; Mike Arnhold; Gregory A. O'Sullivan; Arun Pal; Jonas Said; Giovanni Marsico; Jean Marc Verbavatz; Margarita Rodrigo-Angulo; Gabriele Gille; Richard Funk; Heinz Reichmann

Pathological studies on Parkinsons disease (PD) patients suggest that PD pathology progresses from the enteric nervous system (ENS) and the olfactory bulb into the central nervous system. We have previously shown that environmental toxins acting locally on the ENS mimic this PD-like pathology progression pattern in mice. Here, we show for the first time that the resection of the autonomic nerves stops this progression. Moreover, our results show that an environmental toxin (i.e. rotenone) promotes the release of alpha-synuclein by enteric neurons and that released enteric alpha-synuclein is up-taken by presynaptic sympathetic neurites and retrogradely transported to the soma, where it accumulates. These results strongly suggest that pesticides can initiate the progression of PD pathology and that this progression is based on the transneuronal and retrograde axonal transport of alpha-synuclein. If confirmed in patients, this study would have crucial implications in the strategies used to prevent and treat PD.


Neoplasia | 2015

Pushing the Optical Imaging Limits of Cancer with Multi-Frequency-Band Raster-Scan Optoacoustic Mesoscopy (RSOM)

Murad Omar; Mathias Schwarz; Dominik Soliman; Panagiotis Symvoulidis; Vasilis Ntziachristos

Angiogenesis is a central cancer hallmark, necessary for supporting tumor growth and metastasis. In vivo imaging of angiogenesis is commonly applied, to understand dynamic processes in cancer development and treatment strategies. However, most radiological modalities today assess angiogenesis based on indirect mechanisms, such as the rate of contrast enhancement after contrast agent administration. We studied the performance of raster-scan optoacoustic mesoscopy (RSOM), to directly reveal the vascular network supporting melanoma growth in vivo, at 50 MHz and 100 MHz, through several millimeters of tumor depth. After comparing the performance at each frequency, we recorded, for the first time, high-resolution images of melanin tumor vasculature development in vivo, over a period of several days. Image validation was provided by means of cryo-slice sections of the same tumor after sacrificing the mice. We show how optoacoustic (photoacoustic) mesoscopy reveals a potentially powerful look into tumor angiogenesis, with properties and features that are markedly different than other radiological modalities. This will facilitate a better understanding of tumor’s angiogenesis, and the evaluation of treatment strategies.


Journal of Biophotonics | 2016

Three-dimensional multispectral optoacoustic mesoscopy reveals melanin and blood oxygenation in human skin in vivo

Mathias Schwarz; Andreas Buehler; Juan Aguirre; Vasilis Ntziachristos

Optical imaging plays a major role in disease detection in dermatology. However, current optical methods are limited by lack of three-dimensional detection of pathophysiological parameters within skin. It was recently shown that single-wavelength optoacoustic (photoacoustic) mesoscopy resolves skin morphology, i.e. melanin and blood vessels within epidermis and dermis. In this work we employed illumination at multiple wavelengths for enabling three-dimensional multispectral optoacoustic mesoscopy (MSOM) of natural chromophores in human skin in vivo operating at 15-125 MHz. We employ a per-pulse tunable laser to inherently co-register spectral datasets, and reveal previously undisclosed insights of melanin, and blood oxygenation in human skin. We further reveal broadband absorption spectra of specific skin compartments. We discuss the potential of MSOM for label-free visualization of physiological biomarkers in skin in vivo.


Optics Letters | 2014

Broadband mesoscopic optoacoustic tomography reveals skin layers

Juan Aguirre; Mathias Schwarz; Dominik Soliman; Andreas Buehler; Murad Omar; Vasilis Ntziachristos

We have imaged for the first time to our knowledge human skin in vivo with a raster-scan optoacoustic mesoscopy system based on a spherically focused transducer with a central frequency of 102.8 MHz and large bandwidth (relative bandwidth 105%). Using tissue phantoms we have studied the ability of the system to image vessels of sizes within the anatomically significant range from the key anatomical vasculature sites. The reconstructed images from experiments in vivo show several structures from the capillary loops at the dermal papillae, the horizontal plexus, and the difference between the dermis and the epidermis layers.


IEEE Transactions on Medical Imaging | 2015

Implications of Ultrasound Frequency in Optoacoustic Mesoscopy of the Skin

Mathias Schwarz; Murad Omar; Andreas Buehler; Juan Aguirre; Vasilis Ntziachristos

Raster-scan optoacoustic mesoscopy (RSOM) comes with high potential for in vivo diagnostic imaging in dermatology, since it allows for high resolution imaging of the natural chromophores melanin, and hemoglobin at depths of several millimeters. We have applied ultra-wideband RSOM, in the 10-160 MHz frequency band, to image healthy human skin at distinct locations. We analyzed the anatomical information contained at different frequency ranges of the optoacoustic (photoacoustic) signals in relation to resolving features of different skin layers in vivo. We further compared results obtained from glabrous and hairy skin and identify that frequencies above 60 MHz are necessary for revealing the epidermal thickness, a prerequisite for determining the invasion depth of melanoma in future studies. By imaging a benign nevus we show that the applied RSOM system provides strong contrast of melanin-rich structures. We further identify the spectral bands responsible for imaging the fine structures in the stratum corneum, assessing dermal papillae, and resolving microvascular structures in the horizontal plexus.


Journal of Biophotonics | 2015

Isotropic high resolution optoacoustic imaging with linear detector arrays in bi-directional scanning

Mathias Schwarz; Andreas Buehler; Vasilis Ntziachristos

Optoacoustic (photoacoustic) imaging is often performed with one-dimensional transducer arrays, in analogy to ultrasound imaging. Optoacoustic imaging using linear arrays offers ease of implementation but comes with several performance drawbacks, in particular poor elevation resolution, i.e. the resolution along the axis perpendicular to the focal plane. Herein, we introduce and investigate a bi-directional scanning approach using linear arrays that can improve the imaging performance to quasi-isotropic transverse resolution. We study the approach theoretically and perform numerical simulations and phantom measurements to evaluate its performance under defined conditions. Finally, we discuss the features and the limitations of the proposed method.


IEEE Transactions on Medical Imaging | 2014

24-MHz Scanner for Optoacoustic Imaging of Skin and Burn

Laetitia Vionnet; Jérôme Gateau; Mathias Schwarz; Andreas Buehler; Volodymir Ermolayev; Vasilis Ntziachristos

Optoacoustic (photoacoustic) imaging uniquely visualizes optical contrast in high resolution and comes with very attractive characteristics for clinical imaging applications. In this paper, we showcase the performance of a scanner based on a 24 MHz center-frequency 128 element array, developed for applications in dermatology. We perform system characterization to examine the imaging performance achieved. We then showcase its imaging ability on healthy tissue and cancer. Finally, we image burns and human lesions in vivo and gain insights on the benefits and challenges of this approach as it is considered for diagnostic and treatment follow-up applications in dermatology and beyond.


IEEE Transactions on Medical Imaging | 2017

Optoacoustic Dermoscopy of the Human Skin: Tuning Excitation Energy for Optimal Detection Bandwidth With Fast and Deep Imaging in vivo

Mathias Schwarz; Dominik Soliman; Murad Omar; Andreas Buehler; Saak V. Ovsepian; Juan Aguirre; Vasilis Ntziachristos

Optoacoustic (photoacoustic) dermoscopy offers two principal advantages over conventional optical imaging applied in dermatology. First, it yields high-resolution cross-sectional images of the skin at depths not accessible to other non-invasive optical imaging methods. Second, by resolving absorption spectra at multiple wavelengths, it enables label-free 3D visualization of morphological and functional features. However, the relation of pulse energy to generated bandwidth and imaging depth remains poorly defined. In this paper, we apply computer models to investigate the optoacoustic frequency response generated by simulated skin. We relate our simulation results to experimental measurements of the detection bandwidth as a function of optical excitation energy in phantoms and human skin. Using raster-scan optoacoustic mesoscopy, we further compare the performance of two broadband ultrasonic detectors (a bandwidth of 20–180 and 10–90MHz) in acquiring optoacoustic readouts. Based on the findings of this paper, we propose energy ranges required for skin imaging with considerations of laser safety standards.


Scientific Reports | 2017

Motion correction in optoacoustic mesoscopy

Mathias Schwarz; N. Garzorz-Stark; Kilian Eyerich; Juan Aguirre; Vasilis Ntziachristos

Raster-scan optoacoustic mesoscopy (RSOM), also termed photoacoustic mesoscopy, offers novel insights into vascular morphology and pathophysiological biomarkers of skin inflammation in vivo at depths unattainable by other optical imaging methods. Using ultra-wideband detection and focused ultrasound transducers, RSOM can achieve axial resolution of 4 micron and lateral resolution of 20 micron to depths of several millimeters. However, motion effects may deteriorate performance and reduce the effective resolution. To provide high-quality optoacoustic images in clinical measurements, we developed a motion correction algorithm for RSOM. The algorithm is based on observing disruptions of the ultrasound wave front generated by the vertical movement of the melanin layer at the skin surface. From the disrupted skin surface, a smooth synthetic surface is generated, and the offset between the two surfaces is used to correct for the relative position of the ultrasound detector. We test the algorithm in measurements of healthy and psoriatic human skin and achieve effective resolution up to 5-fold higher than before correction. We discuss the performance of the correction algorithm and its implications in the context of multispectral mesoscopy.


Light-Science & Applications | 2017

Optical imaging of post-embryonic zebrafish using multi orientation raster scan optoacoustic mesoscopy

Murad Omar; Johannes Rebling; Kai Wicker; Tobias Schmitt-Manderbach; Mathias Schwarz; Jérôme Gateau; Hernán López-Schier; Timo Mappes; Vasilis Ntziachristos

Whole-body optical imaging of post-embryonic stage model organisms is a challenging and long sought-after goal. It requires a combination of high-resolution performance and high-penetration depth. Optoacoustic (photoacoustic) mesoscopy holds great promise, as it penetrates deeper than optical and optoacoustic microscopy while providing high-spatial resolution. However, optoacoustic mesoscopic techniques only offer partial visibility of oriented structures, such as blood vessels, due to a limited angular detection aperture or the use of ultrasound frequencies that yield insufficient resolution. We introduce 360° multi orientation (multi-projection) raster scan optoacoustic mesoscopy (MORSOM) based on detecting an ultra-wide frequency bandwidth (up to 160 MHz) and weighted deconvolution to synthetically enlarge the angular aperture. We report unprecedented isotropic in-plane resolution at the 9–17 μm range and improved signal to noise ratio in phantoms and opaque 21-day-old Zebrafish. We find that MORSOM performance defines a new operational specification for optoacoustic mesoscopy of adult organisms, with possible applications in the developmental biology of adulthood and aging.

Collaboration


Dive into the Mathias Schwarz's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bianca Menchicchi

University of Erlangen-Nuremberg

View shared research outputs
Top Co-Authors

Avatar

Birgitta Carlé

University of Erlangen-Nuremberg

View shared research outputs
Top Co-Authors

Avatar

Christina Kersten

University of Erlangen-Nuremberg

View shared research outputs
Top Co-Authors

Avatar

Clemens Neufert

University of Erlangen-Nuremberg

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge