Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Matias Ubilla is active.

Publication


Featured researches published by Matias Ubilla.


American Journal of Roentgenology | 2008

Dual-Source CT for Visualization of the Coronary Arteries in Heart Transplant Patients with High Heart Rates

Gorka Bastarrika; Carlo N. De Cecco; Maria Arraiza; Stefano Mastrobuoni; Jesús C. Pueyo; Matias Ubilla; Gregorio Rábago

OBJECTIVE The purpose of this study was to evaluate the quality of dual-source CT images of the coronary arteries in heart transplant recipients with high heart rates. SUBJECTS AND METHODS Contrast-enhanced dual-source CT coronary angiography was performed on 23 heart transplant recipients (20 men, three women; mean age, 61.1 +/- 12.8 years). Data sets were reconstructed in 5% steps from 30% to 80% of the R-R interval. Two blinded independent readers using a 5-point scale (0, not evaluative; 4, excellent quality) assessed the quality of images of coronary segments. RESULTS The mean heart rate during scanning was 89.2 +/- 10.4 beats/min. Interobserver agreement on the quality of images of the whole coronary tree was a kappa value of 0.78 and for selection of the optimal reconstruction interval was a kappa value of 0.82. The optimal reconstruction interval was systole in 17 (74%) of the 23 of heart transplant recipients. At the best reconstruction interval, diagnostic image quality (score >or= 2) was obtained in 92.1% (303 of 329) of the coronary artery segments. The mean image quality score for the whole coronary tree was 3.1 +/- 1.01. No significant correlation between mean heart rate (rho = 0.31) or heart rate variability (rho = 0.23) and overall image quality score was observed (p = not significant). CONCLUSION Dual-source CT acquisition yields coronary angiograms of diagnostic quality in heart transplant recipients. Mean heart rate and heart rate variability during scanning do not have a negative effect on the overall quality of images of the coronary arteries.


Transplantation | 2009

Dual-source CT coronary angiogram in heart transplant recipients in comparison with dobutamine stress echocardiography for detection of cardiac allograft vasculopathy.

Stefano Mastrobuoni; Gorka Bastarrika; Matias Ubilla; Sara Castaño; Pedro Azcárate; Eduardo Alegria Barrero; Jose M. Castellano; Jesús Herreros; Gregorio Rábago

Conventional coronary angiography (CCA) is the gold standard in the diagnosis of cardiac allograft vasculopathy (CAV) in heart transplant recipients. Dobutamine stress echocardiography (DSE) is a useful technique for screening. Dual-source computed tomography (DSCT) is the last generation of computed tomography scanners, which could be useful to noninvasively assess CAV. Thirty cardiac transplant recipients underwent DSE and DSCT coronary angiogram. Exclusion criteria were as follows: renal insufficiency, iodinated contrast media allergy, less than 12 months since transplant, and unstable clinical conditions. DSE showed ischemia in two patients. At DSCT scan 13 patients had a normal angiogram, 13 ones wall thickening and four significant diseases. DSCT showed a sensitivity of 100% with a specificity of 92%. DSCT allowed detection of more patients with CAV than DSE. Four patients showed significant CAV at DSCT compared with two at DSE. Thirteen patients showed initial signs of disease at DSCT despite a normal DSE.


Journal of Thoracic Imaging | 2009

Dual-source CT in heart transplant recipients: quantification of global left ventricular function and mass.

Gorka Bastarrika; Maria Arraiza; Carlo N. De Cecco; J. Broncano; Stefano Mastrobuoni; Matias Ubilla; Jesús C. Pueyo; Gregorio Rábago

Objective To evaluate reliability of global left ventricular (LV) function and mass quantification in heart transplant recipients undergoing cardiac dual-source computed tomography examinations by means of manual contour tracing and using a region-growing–based semiautomatic segmentation analysis software tool. Materials and Methods Twenty-six consecutive heart transplant recipients undergoing cardiac dual-source computed tomography examinations with tube current modulation were included. Double-oblique short-axis 8-mm slice thickness multiphase image reconstructions were used for manual contouring and axial 0.75 mm slices were used for the semiautomated segmentation. LV ejection fraction, end-diastolic volume, end-systolic volume, stroke volume, cardiac output, and myocardial mass were assessed by both segmentation methods. Length of time needed for manual contour tracing and for the semiautomated software was recorded. Contrast-to-noise ratio was calculated in end-diastolic and end-systolic images. Results No statistically significant differences were observed in LV functional parameters derived from semiautomatic contour detection algorithm as compared with manual contouring, with excellent agreement (concordance-correlation coefficient ≥0.80). The semiautomated contour detection algorithm overestimated LV mass (mean difference 12.84±3.39) (P<0.001). The evaluated software allowed to quantify LV parameters in a significantly shorter period of time (mean difference 201.68±121.98 s, P<0.001). Contrast-to-noise ratio in end-systole and end-diastole statistically differed (mean difference 5.29±2.94 Hounsfield units; P<0.01) but did not significantly hamper the semiautomated segmentation. Conclusions Objective quantification of LV volumes using the evaluated semiautomated segmentation software is precise, reproducible, and time effective.


Artificial Organs | 2010

In Vivo Assessment of a New Method of Pulsatile Perfusion Based on a Centrifugal Pump

Jesús Herreros; Matias Ubilla; Enrique Berjano; Juan E. Vila-Nuñez; José A. Páramo; Josu Sola; Salvador Mercé

The aim of this study was to assess platelet dysfunction and damage to organs after extracorporeal circulation using a pump based on a new method that adds a pulsatile flow to the continuous flow provided by a centrifugal pump. The continuous component of the total flow (2-3 L/min) is created by a Bio-Pump centrifugal pump, while the pulsatile component is created by the pulsating of an inner membrane pneumatically controlled by an intra-aortic counterpulsation balloon console (systolic volume of 37.5 mL in an asynchronous way with a frequency of 60 bpm). Six pigs were subjected to a partial cardiopulmonary bypass lasting 180 min and were sacrificed 60 min after extracorporeal circulation was suspended. The hematological study included the measurement of hematocrit, hemoglobin, leukocytes, and platelet function. The new pump did not significantly alter either platelet count or platelet function. In contrast, hematocrit and hemoglobin were significantly reduced during extracorporeal circulation (approximately 5% P = 0.011, and 2 g/dL P = 0.01, respectively). The leukocyte count during extracorporeal circulation showed a tendency to decrease, but this was not significant. In general, the short-term use of the new pump (4 h) did not cause any serious morphological damage to the heart, lung, kidney, or liver. The results suggest that the hemodynamic performance of the new pump is similar to a conventional centrifugal pump and could therefore be appropriate for use in extracorporeal circulation.


European Radiology | 2008

Quantification of left ventricular function and mass in heart transplant recipients using dual-source CT and MRI: initial clinical experience

Gorka Bastarrika; Maria Arraiza; Carlo N. De Cecco; Stefano Mastrobuoni; Matias Ubilla; Gregorio Rábago


Journal of Heart and Lung Transplantation | 2006

Prevalence of Metabolic Syndrome in Heart Transplant Patients: Role of Previous Cardiopathy and Years Since the Procedure—the TRACA Study

Alberto Cordero Fort; Juan J. Gavira; Eduardo Alegría-Barrero; Sara Castaño; Ana Martín; Matias Ubilla; Stefano Mastrobuoni; Eduardo Alegría Ezquerra; Jesús Herreros; Gregorio Rábago


European Radiology | 2008

Dual-source CT coronary imaging in heart transplant recipients: image quality and optimal reconstruction interval

Gorka Bastarrika; Carlo N. De Cecco; Maria Arraiza; Matias Ubilla; Stefano Mastrobuoni; Jesús C. Pueyo; Gregorio Rábago


Transplantation Proceedings | 2007

Impact on renal function of the use of sirolimus in cardiac transplantation.

Matias Ubilla; Stefano Mastrobuoni; A. Cordero; S. Castaño; Jesús Herreros; Gregorio Rábago


Transplantation Proceedings | 2007

Two-Dose Daclizumab, Tacrolimus, Mycophenolate Mofetil, and Steroid-Free Regimen in De Novo Cardiac Transplant Recipients: Early Experience

Stefano Mastrobuoni; Matias Ubilla; A. Cordero; Jesús Herreros; Gregorio Rábago


Revista Espanola De Cardiologia | 2007

Asistencia biventricular con cardiectomía

Matias Ubilla; Stefano Mastrobuoni; Gregorio Rábago

Collaboration


Dive into the Matias Ubilla's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Carlo N. De Cecco

Medical University of South Carolina

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge