Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Matthew L. Faron is active.

Publication


Featured researches published by Matthew L. Faron.


Journal of Clinical Microbiology | 2016

Multicenter Evaluation of the Xpert Norovirus Assay for Detection of Norovirus Genogroups I and II in Fecal Specimens

Mark D. Gonzalez; L. Claire Langley; Blake W. Buchan; Matthew L. Faron; Melanie Maier; Kate Templeton; Kimberly Walker; Melissa B. Miller; Arundhati Rao; Uwe G. Liebert; Nathan A. Ledeboer; Jan Vinjé; Carey-Ann D. Burnham

ABSTRACT Norovirus is the most common cause of sporadic gastroenteritis and outbreaks worldwide. The rapid identification of norovirus has important implications for infection prevention measures and may reduce the need for additional diagnostic testing. The Xpert Norovirus assay recently received FDA clearance for the detection and differentiation of norovirus genogroups I and II (GI and GII), which account for the vast majority of infections. In this study, we evaluated the performance of the Xpert Norovirus assay with both fresh, prospectively collected (n = 914) and frozen, archived (n = 489) fecal specimens. A Centers for Disease Control and Prevention (CDC) composite reference method was used as the gold standard for comparison. For both prospective and frozen specimens, the Xpert Norovirus assay showed positive percent agreement (PPA) and negative percent agreement (NPA) values of 98.3% and 98.1% for GI and of 99.4% and 98.2% for GII, respectively. Norovirus prevalence in the prospective specimens (collected from March to May of 2014) was 9.9% (n = 90), with the majority of positives caused by genogroup II (82%, n = 74). The positive predictive value (PPV) of the Xpert Norovirus assay was 75% for GI-positive specimens, whereas it was 86.5% for GII-positive specimens. The negative predictive values (NPV) for GI and GII were 100% and 99.9%, respectively.


Journal of Clinical Microbiology | 2016

Resistance Mechanisms, Epidemiology, and Approaches to Screening for Vancomycin-Resistant Enterococcus in the Health Care Setting

Matthew L. Faron; Nathan A. Ledeboer; Blake W. Buchan

ABSTRACT Infections attributable to vancomycin-resistant Enterococcus (VRE) strains have become increasingly prevalent over the past decade. Prompt identification of colonized patients combined with effective multifaceted infection control practices can reduce the transmission of VRE and aid in the prevention of hospital-acquired infections (HAIs). Increasingly, the clinical microbiology laboratory is being asked to support infection control efforts through the early identification of potential patient or environmental reservoirs. This review discusses the factors that contribute to the rise of VRE as an important health care-associated pathogen, the utility of laboratory screening and various infection control strategies, and the available laboratory methods to identify VRE in clinical specimens.


Journal of Clinical Microbiology | 2017

Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Use with Positive Blood Cultures: Methodology, Performance, and Optimization

Matthew L. Faron; Blake W. Buchan; Nathan A. Ledeboer

ABSTRACT Early initiation of effective antibiotics for septic patients is essential for patient survival. Matrix-assisted desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has revolutionized clinical microbiology for isolate identification and has the possibility to impact how blood culture testing is performed. This review discusses the various uses of MALDI-TOF MS for the identification and susceptibility testing of positive blood cultures, the performance of these methods, and the outcomes involved with its implementation.


Journal of Clinical Microbiology | 2016

Automatic Digital Analysis of Chromogenic Media for Vancomycin-Resistant-Enterococcus Screens Using Copan WASPLab

Matthew L. Faron; Blake W. Buchan; Christopher Coon; Theo Liebregts; Anita van Bree; Arjan Jansz; Geneviève Soucy; John Korver; Nathan A. Ledeboer

ABSTRACT Vancomycin-resistant enterococci (VRE) are an important cause of health care-acquired infections (HAIs). Studies have shown that active surveillance of high-risk patients for VRE colonization can aid in reducing HAIs; however, these screens generate a significant cost to the laboratory and health care system. Digital imaging capable of differentiating negative and “nonnegative” chromogenic agar can reduce the labor cost of these screens and potentially improve patient care. In this study, we evaluated the performance of the WASPLab Chromogenic Detection Module (CDM) (Copan, Brescia, Italy) software to analyze VRE chromogenic agar and compared the results to technologist plate reading. Specimens collected at 3 laboratories were cultured using the WASPLab CDM and plated to each sites standard-of-care chromogenic media, which included Colorex VRE (BioMed Diagnostics, White City, OR) or Oxoid VRE (Oxoid, Basingstoke, United Kingdom). Digital images were scored using the CDM software after 24 or 40 h of growth, and all manual reading was performed using digital images on a high-definition (HD) monitor. In total, 104,730 specimens were enrolled and automation agreed with manual analysis for 90.1% of all specimens tested, with sensitivity and specificity of 100% and 89.5%, respectively. Automation results were discordant for 10,348 specimens, and all discordant images were reviewed by a laboratory supervisor or director. After a second review, 499 specimens were identified as representing missed positive cultures falsely called negative by the technologist, 1,616 were identified as containing borderline color results (negative result but with no package insert color visible), and 8,234 specimens were identified as containing colorimetric pigmentation due to residual matrix from the specimen or yeast (Candida). Overall, the CDM was accurate at identifying negative VRE plates, which comprised 84% (87,973) of the specimens in this study.


Journal of Clinical Microbiology | 2015

Detection of Group A Streptococcus in Pharyngeal Swab Specimens by Use of the AmpliVue GAS Isothermal Helicase-Dependent Amplification Assay

Matthew L. Faron; Nathan A. Ledeboer; Paul A. Granato; Judy A. Daly; Kristina Pierce; Preeti Pancholi; Timothy S. Uphoff; Blake W. Buchan

ABSTRACT We evaluated the clinical performance (sensitivity and specificity) of the AmpliVue group A Streptococcus (GAS) isothermal helicase-dependent amplification assay using 1,192 pharyngeal swab specimens. AmpliVue GAS assay results were compared to the results of routine throat cultures on selective streptococcal blood agar plates. The sensitivity and specificity of the AmpliVue GAS assay were 98.3% (95% confidence interval [CI], 95 to 100%) and 93.2% (95% CI, 91 to 95%), respectively.


American Journal of Clinical Pathology | 2017

Multicenter Evaluation of the Bruker MALDI Biotyper CA System for the Identification of Clinically Important Bacteria and Yeasts

Deborah A. Wilson; Stephen Young; Karen Timm; Susan M. Novak-Weekley; Elizabeth M. Marlowe; Neil Madisen; Jennifer L. Lillie; Nathan A. Ledeboer; Rebecca J. Smith; Josh Hyke; Christen Griego-Fullbright; Patricia Jim; Paul A. Granato; Matthew L. Faron; Joven Cumpio; Blake W. Buchan; Gary W. Procop

Objectives A report on the multicenter evaluation of the Bruker MALDI Biotyper CA System (MBT-CA; Bruker Daltonics, Billerica, MA) for the identification of clinically important bacteria and yeasts. Methods In total, 4,399 isolates of medically important bacteria and yeasts were assessed in the MBT-CA. These included 2,262 aerobic gram-positive (AGP) bacteria, 792 aerobic gram-negative (AGN) bacteria 530 anaerobic (AnA) bacteria, and 815 yeasts (YSTs). Three processing methods were assesed. Results Overall, 98.4% (4,329/4,399) of all bacterial and yeast isolates were correctly identified to the genus and species/species complex level, and 95.7% of isolates were identified with a high degree of confidence. The percentage correctly identified and the percentage identified correctly with a high level of confidence, respectively, were as follows: AGP bacteria (98.6%/96.5%), AGN bacteria (98.5%/96.8%), AnA bacteria (98.5%/97.4%), and YSTs (97.8%/87.6%). The extended direct transfer method was only minimally superior to the direct transfer method for bacteria (89.9% vs 86.8%, respectively) but significantly superior for yeast isolates (74.0% vs 48.9%, respectively). Conclusions The Bruker MALDI Biotyper CA System accurately identifies most clinically important bacteria and yeasts and has optional processing methods to improve isolate characterization.


Journal of Clinical Microbiology | 2016

Multicenter Evaluation of Meridian Bioscience HSV 1&2 Molecular Assay for Detection of Herpes Simplex Virus 1 and 2 from Clinical Cutaneous and Mucocutaneous Specimens

Matthew L. Faron; Nathan A. Ledeboer; Anami Patel; Safedin H. Beqa; Belinda Yen-Lieberman; Debra Kohn; Amy Leber; Donna Mayne; William I. Northern; Blake W. Buchan

ABSTRACT Herpes simplex virus (HSV) causes acute and relapsing symptoms characterized by ulcerative lesions. Laboratory diagnosis of HSV in cutaneous or mucocutaneous lesions has historically been performed with the use of viral cell culture systems; however, these tests are laborious and suffer decreased sensitivity for advanced-stage lesions. The recent availability of FDA-cleared moderately complex assays has resulted in the increased use of molecular diagnostics for the routine detection of HSV in superficial swab specimens. We performed a clinical evaluation of the recently FDA-cleared illumigene HSV 1&2 loop-mediated isothermal amplification (LAMP) assay (Meridian Bioscience, Cincinnati OH) for the detection and differentiation of HSV-1 and HSV-2 in cutaneous and mucocutaneous swab specimens. A total of 1,153 clinical swab specimens were collected and tested at 7 different clinical centers. Each specimen was tested for the presence of HSV-1 and HSV-2 using the illumigene assay, and results were compared to those of the enzyme-linked virus-inducible system (ELVIS) as the reference method. Overall, the illumigene assay demonstrated a sensitivity and specificity of 94.8% and 95.5%, respectively, for the detection of HSV-1. Detection of HSV-2 was similar, with a sensitivity of 98.9% and a specificity of 95.5%. Discrepant analysis was performed using an alternative molecular test (AmpliVue HSV1+2 assay; Quidel Molecular, San Diego, CA) on 91/99 specimens that were recorded as false positive (FP) or false negative (FN) compared to the reference method. In total, 57/78 (73%) FP and 9/13 (69%) FN illumigene results were supported by the AmpliVue result. The illumigene HSV 1&2 assay demonstrated high sensitivity and specificity to detect and differentiate HSV in clinical specimens and identified 57 additional specimens that were positive for HSV compared to culture. The use of LAMP eliminates the need for the cycling of temperatures and provides results in less than 60 min, with approximately 2 min of hands-on time per specimen.


Journal of Clinical Microbiology | 2017

Clinical Evaluation and Cost Analysis of Great Basin Shiga Toxin Direct Molecular Assay for Detection of Shiga Toxin-Producing Escherichia coli in Diarrheal Stool Specimens

Matthew L. Faron; Nathan A. Ledeboer; Jessica Connolly; Paul A. Granato; Brenda R. Alkins; Jennifer Dien Bard; Judy A. Daly; Stephen Young; Blake W. Buchan

ABSTRACT The Shiga Toxin Direct molecular assay (ST Direct) relies on nucleic acid amplification and solid array-based amplicon detection to identify Shiga toxin-producing Escherichia coli (STEC) in preserved stool specimens. Genes encoding Shiga toxin (stx1 and stx2), as well as the E. coli serotype O:157-specific marker rfbE, are simultaneously detected within 2 h. ST Direct was evaluated using 1,084 prospectively collected preserved stool specimens across five clinical centers. An additional 55 retrospectively collected, frozen specimens were included to increase the number of positive specimens evaluated. Results were compared to results from routine culture and an enzyme immunoassay (EIA) specific for the recovery and identification of STEC. ST Direct was found to be 93.2% sensitive and 99.3% specific for detection of stx1 and stx2 and 95.7% sensitive and 99.3% specific for detection of E. coli serotype O:157. All specimens with false-positive results were found to contain stx1 or stx2 or were found to be positive for serotype O:157 when analyzed using alternative molecular methods. All 4 false-negative stx1 or stx2 results were reported for frozen, retrospectively tested specimens. In all cases, the specimens tested positive for stx by an alternative FDA-cleared nucleic acid amplification test (NAAT) but were negative for stx1 and stx2 following nucleic acid sequence analysis. Based on these data, culture and EIA-based methods for detection of STEC are only 33% sensitive compared to molecular tests. A retrospective cost analysis demonstrated 59% of the cost of routine stool culture to be attributable to the identification of STEC. Taken together, these data suggest that ST Direct may provide a cost-effective, rapid molecular alternative to routine culture for the identification of STEC in preserved stool specimens.


Journal of Clinical Microbiology | 2017

Evaluation of Copan FecalSwab as Specimen Type for Use in Xpert C. difficile Assay

Michael J. Mashock; Matthew L. Faron; Blake W. Buchan; Nathan A. Ledeboer

ABSTRACT Liquid-based microbiology (LBM) devices incorporating flocked swabs and preservation medium ease transport of specimens and improve specimen yield compared to traditional fiber wound swabs; however, the performance of LBM collection devices has not been evaluated in many molecular assays. It is unclear how the differences in matrix and specimen loading with an LBM device will affect test performance compared to traditional collection devices. The purpose of this study was to evaluate the performance of specimens collected in FecalSwab transport medium (Copan Diagnostics, Murrieta, CA) compared to unpreserved stool using the Cepheid Xpert C. difficile assay (Cepheid, Sunnyvale, CA). Results equivalent to unpreserved stool samples were obtained when 400 μl of FecalSwab-preserved stool was employed in the Xpert assay. The positive and negative percent agreement of specimens inoculated with FecalSwab medium (n = 281) was 97.0% (95% confidence interval [CI], 90.9 to 96.4%) and 99.4% (95% CI, 96.4 to 99.9%), respectively, compared to reference results obtained using unpreserved stool. Throughout this study, only four discrepant results occurred when comparing preserved specimens to unpreserved stool specimens in the Xpert C. difficile PCR assay. Post discrepant analysis, using the BD MAX Cdiff assay, the specificity and sensitivity both increased to 100%. The high positive and negative percent agreements observed in this study suggest that stool preserved in FecalSwab media yields equivalent results to using unpreserved stool when tested on the Xpert C. difficile assay, allowing laboratories to adopt this liquid-based microbiology collection device.


Journal of Clinical Microbiology | 2017

Multicenter Evaluation of the Portrait Staph ID/R Blood Culture Panel for Rapid Identification of Staphylococci and Detection of the mecA Gene

Gerald A. Denys; Vanessa Collazo-Velez; Stephen Young; Judy A. Daly; Marc Roger Couturier; Matthew L. Faron; Blake W. Buchan; Nathan A. Ledeboer

ABSTRACT Bloodstream infections are a leading cause of morbidity and mortality in the United States and are associated with increased health care costs. We evaluated the Portrait Staph ID/R blood culture panel (BCP) multiplex PCR assay (Great Basin Scientific, Salt Lake City, UT) for the rapid and simultaneous identification (ID) of Staphylococcus aureus, Staphylococcus lugdunensis, and Staphylococcus species to the genus level and the detection of the mecA gene directly from a positive blood culture bottle. A total of 765 Bactec bottles demonstrating Gram-positive cocci in singles or clusters were tested during the prospective trial at 3 clinical sites. The Portrait Staph ID/R BCP results were compared with results from conventional biochemical and cefoxitin disk methods performed at an independent laboratory. Discordant ID and mecA results were resolved by rpoB gene sequencing and mecA gene sequencing, respectively. A total of 658 Staphylococcus species isolates (S. aureus, 211 isolates; S. lugdunensis, 3 isolates; and Staphylococcus spp., 444 isolates) were recovered from monomicrobial and 33 polymicrobial blood cultures. After discrepant analysis, the overall ratios of Portrait Staph ID/R BCP positive percent agreement and negative percent agreement were 99.4%/99.9% for Staphylococcus ID and 99.7%/99.2% for mecA detection.

Collaboration


Dive into the Matthew L. Faron's collaboration.

Top Co-Authors

Avatar

Nathan A. Ledeboer

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar

Blake W. Buchan

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar

Paul A. Granato

State University of New York Upstate Medical University

View shared research outputs
Top Co-Authors

Avatar

Stephen Young

University of New Mexico

View shared research outputs
Top Co-Authors

Avatar

Judy A. Daly

Primary Children's Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge