Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Matthew R. Bersi is active.

Publication


Featured researches published by Matthew R. Bersi.


Journal of Biomechanical Engineering-transactions of The Asme | 2015

Decreased Elastic Energy Storage, Not Increased Material Stiffness, Characterizes Central Artery Dysfunction in Fibulin-5 Deficiency Independent of Sex

J. Ferruzzi; Matthew R. Bersi; S. Uman; Hiromi Yanagisawa; Jay D. Humphrey

Central artery stiffness has emerged over the past 15 years as a clinically significant indicator of cardiovascular function and initiator of disease. Loss of elastic fiber integrity is one of the primary contributors to increased arterial stiffening in aging, hypertension, and related conditions. Elastic fibers consist of an elastin core and multiple glycoproteins; hence defects in any of these constituents can adversely affect arterial wall mechanics. In this paper, we focus on mechanical consequences of the loss of fibulin-5, an elastin-associated glycoprotein involved in elastogenesis. Specifically, we compared the biaxial mechanical properties of five central arteries-the ascending thoracic aorta, descending thoracic aorta, suprarenal abdominal aorta, infrarenal abdominal aorta, and common carotid artery-from male and female wild-type and fibulin-5 deficient mice. Results revealed that, independent of sex, all five regions in the fibulin-5 deficient mice manifested a marked increase in structural stiffness but also a marked decrease in elastic energy storage and typically an increase in energy dissipation, with all differences being most dramatic in the ascending and abdominal aortas. Given that the primary function of large arteries is to store elastic energy during systole and to use this energy during diastole to work on the blood, fibulin-5 deficiency results in a widespread diminishment of central artery function that can have significant effects on hemodynamics and cardiac function.


Annals of Biomedical Engineering | 2014

Consistent Biomechanical Phenotyping of Common Carotid Arteries from Seven Genetic, Pharmacological, and Surgical Mouse Models

Matthew R. Bersi; J. Ferruzzi; John F. Eberth; Rudolph L. Gleason; Jay D. Humphrey

The continuing lack of longitudinal histopathological and biomechanical data for human arteries in health and disease highlights the importance of studying the many genetic, pharmacological, and surgical models that are available in mice. As a result, there has been a significant increase in the number of reports on the biomechanics of murine arteries over the past decade, particularly for the common carotid artery. Whereas most of these studies have focused on wild-type controls or comparing controls vs. a single model of altered hemodynamics or vascular disease, there is a pressing need to compare results across many different models to understand more broadly the effects of genetic mutations, pharmacological treatments, or surgical alterations on the evolving hemodynamics and the microstructure and biomechanical properties of these vessels. This paper represents a first step toward this goal, that is, a biomechanical phenotyping of common carotid arteries from control mice and seven different mouse models that represent alterations in elastic fiber integrity, collagen remodeling, and smooth muscle cell functionality.


Hypertension | 2016

Excessive Adventitial Remodeling Leads to Early Aortic Maladaptation in Angiotensin-Induced Hypertension.

Matthew R. Bersi; Chiara Bellini; Jing Wu; Kim Ramil C. Montaniel; David G. Harrison; Jay D. Humphrey

The primary function of central arteries is to store elastic energy during systole and to use it to sustain blood flow during diastole. Arterial stiffening compromises this normal mechanical function and adversely affects end organs, such as the brain, heart, and kidneys. Using an angiotensin II infusion model of hypertension in wild-type mice, we show that the thoracic aorta exhibits a dramatic loss of energy storage within 2 weeks that persists for at least 4 weeks. This diminished mechanical functionality results from increased structural stiffening as a result of an excessive accumulation of adventitial collagen, not a change in the intrinsic stiffness of the wall. A detailed analysis of the transmural biaxial wall stress suggests that the exuberant production of collagen results more from an inflammatory response than from a mechano-adaptation, hence reinforcing the need to control inflammation, not just blood pressure. Although most clinical assessments of arterial stiffening focus on intimal–medial thickening, these results suggest a need to measure and control the highly active and important adventitia.


Journal of Biomechanical Engineering-transactions of The Asme | 2016

Novel Methodology for Characterizing Regional Variations in the Material Properties of Murine Aortas

Matthew R. Bersi; Chiara Bellini; Paolo Di Achille; Jay D. Humphrey; Katia Genovese; Stéphane Avril

Many vascular disorders, including aortic aneurysms and dissections, are characterized by localized changes in wall composition and structure. Notwithstanding the importance of histopathologic changes that occur at the microstructural level, macroscopic manifestations ultimately dictate the mechanical functionality and structural integrity of the aortic wall. Understanding structure-function relationships locally is thus critical for gaining increased insight into conditions that render a vessel susceptible to disease or failure. Given the scarcity of human data, mouse models are increasingly useful in this regard. In this paper, we present a novel inverse characterization of regional, nonlinear, anisotropic properties of the murine aorta. Full-field biaxial data are collected using a panoramic-digital image correlation (p-DIC) system. An inverse method, based on the principle of virtual power (PVP), is used to estimate values of material parameters regionally for a microstructurally motivated constitutive relation. We validate our experimental-computational approach by comparing results to those from standard biaxial testing. The results for the nondiseased suprarenal abdominal aorta from apolipoprotein-E null mice reveal material heterogeneities, with significant differences between dorsal and ventral as well as between proximal and distal locations, which may arise in part due to differential perivascular support and localized branches. Overall results were validated for both a membrane and a thick-wall model that delineated medial and adventitial properties. Whereas full-field characterization can be useful in the study of normal arteries, we submit that it will be particularly useful for studying complex lesions such as aneurysms, which can now be pursued with confidence given the present validation.


Journal of Biomechanics | 2014

Characterization of evolving biomechanical properties of tissue engineered vascular grafts in the arterial circulation.

Brooks V. Udelsman; Kristin S. Miller; Ethan W. Dean; Matthew R. Bersi; Kevin A. Rocco; Tai Yi; Jay D. Humphrey; Christopher K. Breuer

We used a murine model to assess the evolving biomechanical properties of tissue engineered vascular grafts (TEVGs) implanted in the arterial circulation. The initial polymeric tubular scaffold was fabricated from poly(lactic acid)(PLA) and coated with a 50:50 copolymer of poly(caprolactone) and poly(lactic acid)(P[PC/LA]). Following seeding with syngeneic bone marrow derived mononuclear cells, TEVGs (n=50) were implanted as aortic interposition grafts in wild-type mice and monitored serially using ultrasound. A custom biaxial mechanical testing device was used to quantify the in vitro circumferential and axial mechanical properties of grafts explanted at 3 or 7 months. At both times, TEVGs were much stiffer than native tissue in both directions. Repeated mechanical testing of some TEVGs treated with elastase or collagenase suggested that elastin did not contribute significantly to the overall stiffness whereas collagen did contribute. Traditional histology and immunostaining revealed smooth muscle cell layers, significant collagen deposition, and increasing elastin production in addition to considerable scaffold at both 3 and 7 months, which likely dominated the high stiffness seen in mechanical testing. These results suggest that PLA has inadequate in vivo degradation, which impairs cell-mediated development of vascular neotissue having properties closer to native arteries. Assessing contributions of individual components, such as elastin and collagen, to the developing neovessel is needed to guide computational modeling that may help to optimize the design of the TEVG.


Journal of the Royal Society Interface | 2017

Differential cell-matrix mechanoadaptations and inflammation drive regional propensities to aortic fibrosis, aneurysm or dissection in hypertension

Matthew R. Bersi; A. J. Wujciak; David G. Harrison; Jay D. Humphrey

The embryonic lineage of intramural cells, microstructural organization of the extracellular matrix, local luminal and wall geometry, and haemodynamic loads vary along the length of the aorta. Yet, it remains unclear why certain diseases manifest differentially along the aorta. Toward this end, myriad animal models provide insight into diverse disease conditions—including fibrosis, aneurysm and dissection—but inherent differences across models impede general interpretations. We examined region-specific cellular, matrix, and biomechanical changes in a single experimental model of hypertension and atherosclerosis, which commonly coexist. Our findings suggest that (i) intramural cells within the ascending aorta are unable to maintain the intrinsic material stiffness of the wall, which ultimately drives aneurysmal dilatation, (ii) a mechanical stress-initiated, inflammation-driven remodelling within the descending aorta results in excessive fibrosis, and (iii) a transient loss of adventitial collagen within the suprarenal aorta contributes to dissection propensity. Smooth muscle contractility helps to control wall stress in the infrarenal aorta, which maintains mechanical properties near homeostatic levels despite elevated blood pressure. This early mechanoadaptation of the infrarenal aorta does not preclude subsequent acceleration of neointimal formation, however. Because region-specific conditions may be interdependent, as, for example, diffuse central arterial stiffening can increase cyclic haemodynamic loads on an aneurysm that is developing proximally, there is a clear need for more systematic assessments of aortic disease progression, not simply a singular focus on a particular region or condition.


Journal of the Royal Society Interface | 2017

Comparison of 10 murine models reveals a distinct biomechanical phenotype in thoracic aortic aneurysms

Chiara Bellini; Matthew R. Bersi; A. W. Caulk; J. Ferruzzi; Dianna M. Milewicz; Francesco Ramirez; Daniel B. Rifkin; George Tellides; Hiromi Yanagisawa; Jay D. Humphrey

Thoracic aortic aneurysms are life-threatening lesions that afflict young and old individuals alike. They frequently associate with genetic mutations and are characterized by reduced elastic fibre integrity, dysfunctional smooth muscle cells, improperly remodelled collagen and pooled mucoid material. There is a pressing need to understand better the compromised structural integrity of the aorta that results from these genetic mutations and renders the wall vulnerable to dilatation, dissection or rupture. In this paper, we compare the biaxial mechanical properties of the ascending aorta from 10 murine models: wild-type controls, acute elastase-treated, and eight models with genetic mutations affecting extracellular matrix proteins, transmembrane receptors, cytoskeletal proteins, or intracellular signalling molecules. Collectively, our data for these diverse mouse models suggest that reduced mechanical functionality, as indicated by a decreased elastic energy storage capability or reduced distensibility, does not predispose to aneurysms. Rather, despite normal or lower than normal circumferential and axial wall stresses, it appears that intramural cells in the ascending aorta of mice prone to aneurysms are unable to maintain or restore the intrinsic circumferential material stiffness, which may render the wall biomechanically vulnerable to continued dilatation and possible rupture. This finding is consistent with an underlying dysfunctional mechanosensing or mechanoregulation of the extracellular matrix, which normally endows the wall with both appropriate compliance and sufficient strength.


IEEE Transactions on Medical Imaging | 2017

Multi-Modality Imaging Enables Detailed Hemodynamic Simulations in Dissecting Aneurysms in Mice

Evan H. Phillips; Paolo Di Achille; Matthew R. Bersi; Jay D. Humphrey; Craig J. Goergen

A multi-modality imaging-based modeling approach was used to study complex unsteady hemodynamics and lesion growth in a dissecting abdominal aortic aneurysm model. We combined in vivo ultrasound (geometry and flow) and in vitro optical coherence tomography (OCT) (geometry) to obtain the high resolution needed to construct detailed hemodynamic simulations over large portions of the murine vasculature, which include fine geometric complexities. We illustrate this approach for a spectrum of dissecting abdominal aortic aneurysms induced in male apolipoprotein E-null mice by high-dose angiotensin II infusion. In vivo morphological and hemodynamic data provide information on volumetric lesion growth and changes in blood flowdynamics, respectively, occurring fromthe day of initial aortic expansion. We validated the associatedcomputational models by comparing results on time-varying outlet flows and vortical structureswithin the lesions. Three out of four lesions exhibited abrupt formation of thrombus, though different in size. We determined that a lesion without thrombus formed with a thickened vessel wall, which was resolvable by OCT and histology. We attribute differences in final sizes and compositions of these lesions to the different computed flow and vortical structures we obtained in our mouse-specific fluid dynamic models. Differences in morphology and hemodynamics play crucial roles in determining the evolution of dissecting abdominal aortic aneurysms. Coupled high resolution in vivo and in vitro imaging approaches provide much-improved geometric models for hemodynamic simulations. Our imaging-based computational findings suggest a link between perturbations in hemodynamic metrics and aneurysmal disease heterogeneity.


Journal of The Mechanical Behavior of Biomedical Materials | 2017

A hidden structural vulnerability in the thrombospondin-2 deficient aorta increases the propensity to intramural delamination

Chiara Bellini; Nina Kristofik; Matthew R. Bersi; Themis R. Kyriakides; Jay D. Humphrey

Mice lacking thrombospondin-2 (TSP2) represent an animal model of impaired collagen fibrillogenesis. Collagen constitutes ~1/3 of the wall of the normal murine descending thoracic aorta (DTA) and is thought to confer mechanical strength at high pressures. Microstructural analysis of the DTA from TSP2-null mice revealed irregular and disorganized collagen fibrils in the adventitia and at the interface between the media and adventitia. Yet, biaxial mechanical tests performed under physiologic loading conditions showed that most mechanical metrics, including stress and stiffness, were not different between mutant and control DTAs at 20- and 40-weeks of age, thus suggesting that the absence of TSP2 is well compensated under normal conditions. A detailed bilayered analysis of the wall mechanics predicted, however, that the adventitia of TSP2-null DTAs fails to engage at high pressures, which could render the media vulnerable to mechanical damage. Failure tests confirmed that the pressure at which the DTA ruptures is significantly lower in 20-week-old TSP2-null mice compared to age-matched controls (640±37 vs. 1120±45mmHg). Moreover, half of the 20-week-old and all 40-week-old mutant DTAs failed by delamination, not rupture. This delamination occurred at the interface between the media and the adventitia, with separation planes often observed at ~45 degrees with respect to the circumferential/axial directions. Combined with the observed microstructural anomalies, our theoretical-experimental biomechanical results suggest that TSP2-null DTAs are more susceptible to material failure when exposed to high pressures and this vulnerability may result from a reduced resistance to shear loading at the medial/adventitial border.


Arteriosclerosis, Thrombosis, and Vascular Biology | 2017

Deficient Circumferential Growth Is the Primary Determinant of Aortic Obstruction Attributable to Partial Elastin Deficiency

Yang Jiao; Guangxin Li; Arina Korneva; Alexander W. Caulk; Lingfeng Qin; Matthew R. Bersi; Qingle Li; Wei Li; Robert P. Mecham; Jay D. Humphrey; George Tellides

Objective— Williams syndrome is characterized by obstructive aortopathy attributable to heterozygous loss of ELN, the gene encoding elastin. Lesions are thought to result primarily from excessive smooth muscle cell (SMC) proliferation and consequent medial expansion, although an initially smaller caliber and increased stiffness of the aorta may contribute to luminal narrowing. The relative contributions of such abnormalities to the obstructive phenotype had not been defined. Approach and Results— We quantified determinants of luminal stenosis in thoracic aortas of Eln−/− mice incompletely rescued by human ELN. Moderate obstruction was largely because of deficient circumferential growth, most prominently of ascending segments, despite increased axial growth. Medial thickening was evident in these smaller diameter elastin-deficient aortas, with medial area similar to that of larger diameter control aortas. There was no difference in cross-sectional SMC number between mutant and wild-type genotypes at multiple stages of postnatal development. Decreased elastin content was associated with medial fibrosis and reduced aortic distensibility because of increased structural stiffness but preserved material stiffness. Elastin-deficient SMCs exhibited greater contractile-to-proliferative phenotypic modulation in vitro than in vivo. We confirmed increased medial collagen without evidence of increased medial area or SMC number in a small ascending aorta with thickened media of a Williams syndrome subject. Conclusions— Deficient circumferential growth is the predominant mechanism for moderate obstructive aortic disease resulting from partial elastin deficiency. Our findings suggest that diverse aortic manifestations in Williams syndrome result from graded elastin content, and SMC hyperplasia causing medial expansion requires additional elastin loss superimposed on ELN haploinsufficiency.

Collaboration


Dive into the Matthew R. Bersi's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jing Wu

Vanderbilt University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kasey C. Vickers

Vanderbilt University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge