Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Matthew Signal is active.

Publication


Featured researches published by Matthew Signal.


The New England Journal of Medicine | 2015

Neonatal Glycemia and Neurodevelopmental Outcomes at 2 Years

Christopher J.D. McKinlay; Jane M. Alsweiler; Judith M. Ansell; Nicola Anstice; J. Geoffrey Chase; G. Gamble; Deborah L. Harris; Robert J. Jacobs; Yannan Jiang; Nabin Paudel; Matthew Signal; Benjamin Thompson; Trecia A. Wouldes; Tzu-Ying Yu; Jane E. Harding

BACKGROUND Neonatal hypoglycemia is common and can cause neurologic impairment, but evidence supporting thresholds for intervention is limited. METHODS We performed a prospective cohort study involving 528 neonates with a gestational age of at least 35 weeks who were considered to be at risk for hypoglycemia; all were treated to maintain a blood glucose concentration of at least 47 mg per deciliter (2.6 mmol per liter). We intermittently measured blood glucose for up to 7 days. We continuously monitored interstitial glucose concentrations, which were masked to clinical staff. Assessment at 2 years included Bayley Scales of Infant Development III and tests of executive and visual function. RESULTS Of 614 children, 528 were eligible, and 404 (77% of eligible children) were assessed; 216 children (53%) had neonatal hypoglycemia (blood glucose concentration, <47 mg per deciliter). Hypoglycemia, when treated to maintain a blood glucose concentration of at least 47 mg per deciliter, was not associated with an increased risk of the primary outcomes of neurosensory impairment (risk ratio, 0.95; 95% confidence interval [CI], 0.75 to 1.20; P=0.67) and processing difficulty, defined as an executive-function score or motion coherence threshold that was more than 1.5 SD from the mean (risk ratio, 0.92; 95% CI, 0.56 to 1.51; P=0.74). Risks were not increased among children with unrecognized hypoglycemia (a low interstitial glucose concentration only). The lowest blood glucose concentration, number of hypoglycemic episodes and events, and negative interstitial increment (area above the interstitial glucose concentration curve and below 47 mg per deciliter) also did not predict the outcome. CONCLUSIONS In this cohort, neonatal hypoglycemia was not associated with an adverse neurologic outcome when treatment was provided to maintain a blood glucose concentration of at least 47 mg per deciliter. (Funded by the Eunice Kennedy Shriver National Institute of Child Health and Human Development and others.).


Annals of Intensive Care | 2011

Pilot proof of concept clinical trials of Stochastic Targeted (STAR) glycemic control.

Alicia Evans; Geoffrey M. Shaw; Aaron Le Compte; Chia -Siong Tan; Logan Ward; James Steel; Christopher G. Pretty; Leesa Pfeifer; Sophie Penning; Fatanah M. Suhaimi; Matthew Signal; Thomas Desaive; J. Geoffrey Chase

IntroductionTight glycemic control (TGC) has shown benefits but has been difficult to achieve consistently. STAR (Stochastic TARgeted) is a flexible, model-based TGC approach directly accounting for intra- and inter- patient variability with a stochastically derived maximum 5% risk of blood glucose (BG) < 4.0 mmol/L. This research assesses the safety, efficacy, and clinical burden of a STAR TGC controller modulating both insulin and nutrition inputs in pilot trials.MethodsSeven patients covering 660 hours. Insulin and nutrition interventions are given 1-3 hourly as chosen by the nurse to allow them to manage workload. Interventions are calculated by using clinically validated computer models of human metabolism and its variability in critical illness to maximize the overlap of the model-predicted (5-95th percentile) range of BG outcomes with the 4.0-6.5 mmol/L band while ensuring a maximum 5% risk of BG < 4.0 mmol/L. Carbohydrate intake (all sources) was selected to maximize intake up to 100% of SCCM/ACCP goal (25 kg/kcal/h). Maximum insulin doses and dose changes were limited for safety. Measurements were made with glucometers. Results are compared to those for the SPRINT study, which reduced mortality 25-40% for length of stay ≥3 days. Written informed consent was obtained for all patients, and approval was granted by the NZ Upper South A Regional Ethics Committee.ResultsA total of 402 measurements were taken over 660 hours (~14/day), because nurses showed a preference for 2-hourly measurements. Median [interquartile range, (IQR)] cohort BG was 5.9 mmol/L [5.2-6.8]. Overall, 63.2%, 75.9%, and 89.8% of measurements were in the 4.0-6.5, 4.0-7.0, and 4.0-8.0 mmol/L bands. There were no hypoglycemic events (BG < 2.2 mmol/L), and the minimum BG was 3.5 mmol/L with 4.5% < 4.4 mmol/L. Per patient, the median [IQR] hours of TGC was 92 h [29-113] using 53 [19-62] measurements (median, ~13/day). Median [IQR] results: BG, 5.9 mmol/L [5.8-6.3]; carbohydrate nutrition, 6.8 g/h [5.5-8.7] (~70% goal feed median); insulin, 2.5 U/h [0.1-5.1]. All patients achieved BG < 6.1 mmol/L. These results match or exceed SPRINT and clinical workload is reduced more than 20%.ConclusionsSTAR TGC modulating insulin and nutrition inputs provided very tight control with minimal variability by managing intra- and inter- patient variability. Performance and safety exceed that of SPRINT, which reduced mortality and cost in the Christchurch ICU. The use of glucometers did not appear to impact the quality of TGC. Finally, clinical workload was self-managed and reduced 20% compared with SPRINT.


Journal of diabetes science and technology | 2010

Continuous Glucose Monitors and the Burden of Tight Glycemic Control in Critical Care: Can They Cure the Time Cost?

Matthew Signal; Christopher G. Pretty; J. Geoffrey Chase; Aaron Le Compte; Geoffrey M. Shaw

Background: Tight glycemic control (TGC) in critical care has shown distinct benefits but has also proven to be difficult to obtain. The risk of severe hypoglycemia (<40 mg/dl) raises significant concerns for safety. Added clinical burden has also been an issue. Continuous glucose monitors (CGMs) offer frequent automated measurement and thus the possibility of using them for early detection and intervention of hypoglycemic events. Additionally, regular measurement by CGM may also be able to reduce clinical burden. Aim: An in silico study investigates the potential of CGM devices to reduce clinical effort in a published TGC protocol. Methods: This study uses retrospective clinical data from the Specialized Relative Insulin Nutrition Titration (SPRINT) TGC study covering 20 patients from a benchmark cohort. Clinically validated metabolic system models are used to generate a blood glucose (BG) profile for each patient, resulting in 33 continuous, separate BG episodes (6881 patient hours). The in silico analysis is performed with three different stochastic noise models: Two Gaussian and one first-order autoregressive. The noisy, virtual CGM BG values are filtered and used to drive the SPRINT TGC protocol. A simple threshold alarm is used to trigger glucose interventions to avert potential hypoglycemia. The Monte Carlo method was used to get robust results from the stochastic noise models. Results: Using SPRINT with simulated CGM noise, the BG time in an 80–110 mg/dl band was reduced no more than 4.4% to 45.2% compared to glucometer sensors. Antihypoglycemic interventions had negligible effect on time in band but eliminated all recorded hypoglycemic episodes in these simulations. Assuming 4–6 calibration measurements per day, the nonautomated clinical measurements are reduced from an average of 16 per day to as low as 4. At 2.5 min per glucometer measurement, a daily saving of ~25–30 min per patient could potentially be achieved. Conclusions: This paper has analyzed in silico the use of CGM sensors to provide BG input data to the SPRINT TGC protocol. A very simple algorithm was used for early hypoglycemic detection and prevention and tested with four different-sized intravenous glucose boluses. Although a small decrease in time in band (still clinically acceptable) was experienced with the addition of CGM noise, the number of hypoglycemic events was reduced. The reduction to time in band depends on the specific CGM sensor error characteristics and is thus a trade-off for reduced nursing workload. These results justify a pilot clinical trial to verify this study.


Journal of diabetes science and technology | 2010

Hypoglycemia Detection in Critical Care Using Continuous Glucose Monitors: An in Silico Proof of Concept Analysis

Christopher G. Pretty; J. Geoffrey Chase; Aaron Le Compte; Geoffrey M. Shaw; Matthew Signal

Background: Tight glycemic control (TGC) in critical care has shown distinct benefits but has also been proven difficult to obtain. The risk of severe hypoglycemia (<40 mg/dl) has been increased significantly in several, but not all, studies, raising significant concerns for safety. Continuous glucose monitors (CGMs) offer frequent measurement and thus the possibility of using them for early detection alarms to prevent hypoglycemia. Methods: This study used retrospective clinical data from the Specialized Relative Insulin Nutrition Titration TGC study covering seven patients who experienced severe hypoglycemic events. Clinically validated metabolic system models were used to recreate a continuous blood glucose profile. In silico analysis was enabled by using a conservative single Gaussian noise model based on reported CGM clinical data from a critical care study [mean absolute percent error (MAPE) 17.4%]. A novel median filter was implemented and further smoothed with a least mean squares-fitted polynomial to reduce sensor noise. Two alarm approaches were compared. An integral-based method is presented that examined the area between a preset threshold and filtered simulated CGM data. An alarm was raised when this value became too low. A simple glycemic threshold method was also used for comparison. To account for random noise skewing the results, each patient record was Monte Carlo simulated 100 times with a different random noise profile for a total of 700 runs. Different alarm thresholds were analyzed parametrically. Results are reported in terms of detection time before the clinically measured event and any false alarms. These retrospective clinical data were used with approval from the New Zealand South Island Regional Ethics Committee. Results: The median filter reduced MAPE from 17.4% [standard deviation (SD) 13%] to 9.3% (SD 7%) over the cohort. For the integral-based alarm, median per-patient detection times ranged, t, from −35 minutes (before event) to −170 minutes, with zero to two false alarms per patient over the cohort and different alarm parameters. For a simple glycemic threshold alarm (three consecutive values below threshold), median per-patient alarm times were −10 to −75 minutes and false alarms were zero to seven; however, in one case, five of seven subjects never alarmed at all, despite the hypoglycemic event. Conclusions: A retrospective study used clinical hypoglycemic events from a TGC study to develop and analyze an integral-based hypoglycemia alarm for use in critical care TGC studies. The integral-based approach was accurate, provided significant lead time before a hypoglycemic event, alarmed at higher glycemic levels, was robust to sensor noise, and had minimal false alarms. The approach is readily generalizable to similar scenarios, and results would justify a pilot clinical trial to verify this study.


Journal of diabetes science and technology | 2012

Glycemic levels in critically ill patients: are normoglycemia and low variability associated with improved outcomes?

Matthew Signal; Aaron Le Compte; Geoffrey M. Shaw; J. Geoffrey Chase

Background: Critically ill patients often experience high levels of insulin resistance and stress-induced hyperglycemia, which may negatively impact outcomes. In 2001, Van den Berghe and coauthors used intensive insulin therapy (IIT) to control blood glucose (BG) to normal levels and reported a reduction in intensive care unit (ICU) mortality from 8% to 4.6%. Many studies tried to replicate these results, with some showing reduced mortality, others failing to match these results, and many seeing no clinically significant difference. The interpretation of results is important when drawing conclusions about the benefits and risks of IIT. There is the potential for negative results to be falsely negative due to unintended patient crossover or cohort overlap. Aim: The aim of this study was to investigate the association between the amount of time each critically ill patient experiences good glucose control and hospital mortality. Methods: This study uses BG data from 784 patients admitted to the Christchurch Hospital ICU between January 2003 and May 2007. For each of the 5 days of analysis, all patients with BG data were pooled together in a single cohort before being stratified into two subcohorts based on glycemic performance, determined by cumulative time in band (cTIB). The cTIB metric is calculated per patient/per day and defined here as the percentage of time the patients BG levels have been cumulatively in a specific band (72–126 mg/dl) up to and including the considered day. Subcohort A had patients with cTIB ≥ threshold and subcohort B had patients with cTIB < threshold. Three cTIB thresholds were tested: 0.3 (30%), 0.5 (50%), and 0.7 (70%). The odds of living (OL) were then calculated for each subcohort and day, forming the basis of comparison between the subcohorts. A second analysis was run using only the 310 patients with BG data for 5 days or more to assess the impact of patient dropout. Results: Results show that, across all three cTIB threshold levels (0.3, 0.5, and 0.7) and all 5 days of analysis, patients with a cTIB ≥ threshold have a higher OL than patients with a cTIB < threshold. A cTIB threshold of 0.7 showed the strongest separation between the subcohorts, and on day 5, the OL for subcohort A was 4.4 versus 1.6 for subcohort B. The second analysis showed that patient dropout had little effect on the overall trends. Using a cTIB threshold of 0.7, the OL for subcohort A was 0.8 higher than the OL for subcohort B on day 1, which steadily increased over the 5 days of analysis. Conclusions: Results show that OL are higher for patients with cTIB ≥ 0.3–0.7 than patients with cTIB < 0.3–0.7, irrespective of how cTIB was achieved. A cTIB threshold of 0.5 was found to be a minimum acceptable threshold based on outcome. If cTIB is used in similar BG studies in the future, cTIB ≥ 0.7 may be a good target for glycemic control to ensure outcomes and to separate patients with good BG control from patients with poor control.


Journal of Critical Care | 2014

Does the achievement of an intermediate glycemic target reduce organ failure and mortality? A post hoc analysis of the Glucontrol trial.

Sophie Penning; Geoffrey Chase; Jean-Charles Preiser; Christopher G. Pretty; Matthew Signal; Christian Melot; Thomas Desaive

OBJECTIVE This research evaluates the impact of the achievement of an intermediate target glycemic band on the severity of organ failure and mortality. METHODS Daily Sequential Organ Failure Assessment (SOFA) score and the cumulative time in a 4.0 to 7.0 mmol/L band (cTIB) were evaluated daily up to 14 days in 704 participants of the multicentre Glucontrol trial (16 centers) that randomized patients to intensive group A (blood glucose [BG] target: 4.4-6.1 mmol/L) or conventional group B (BG target: 7.8-10.0 mmol/L). Sequential Organ Failure Assessment evolution was measured by percentage of patients with SOFA less than or equal to 5 on each day, percentage of individual organ failures, and percentage of organ failure-free days. Conditional and joint probability analysis of SOFA and cTIB 0.5 or more assessed the impact of achieving 4.0 to 7.0 mmol/L target glycemic range on organ failure. Odds ratios (OR) compare the odds risk of death for cTIB 0.5 or more vs cTIB less than 0.5, where a ratio greater than 1.0 indicates an improvement for achieving cTIB 0.5 or more independent of SOFA or glycemic target. RESULTS Groups A and B were matched for demographic and severity of illness data. Blood glucose differed between groups A and B (P<.05), as expected. There was no difference in the percentage of patients with SOFA less than or equal to 5, individual organ failures, and organ failure-free days between groups A and B over days 1 to 14. However, 20% to 30% of group A patients failed to achieve cTIB 0.5 or more for all days, and significant crossover confounds interpretation. Mortality OR was greater than 1.0 for patients with cTIB 0.5 or more in both groups but much higher for group A on all days. CONCLUSIONS There was no difference in organ failure in the Glucontrol study based on intention to treat to different glycemic targets. Actual outcomes and significant crossover indicate that this result may not be due to the difference in target or treatment. Odds ratios-associated achieving an intermediate 4.0 to 7.0 mmol/L range improved outcome.


Biomedical Engineering Online | 2012

Using Stochastic modelling to identify unusual continuous glucose monitor measurements and behaviour, in newborn infants

Matthew Signal; Aaron Le Compte; Deborah L. Harris; Phil Weston; Jane E. Harding; J. Geoffrey Chase

BackgroundAbnormal blood glucose (BG) concentrations have been associated with increased morbidity and mortality in both critically ill adults and infants. Furthermore, hypoglycaemia and glycaemic variability have both been independently linked to mortality in these patients. Continuous Glucose Monitoring (CGM) devices have the potential to improve detection and diagnosis of these glycaemic abnormalities. However, sensor noise is a trade-off of the high measurement rate and must be managed effectively if CGMs are going to be used to monitor, diagnose and potentially help treat glycaemic abnormalities.AimTo develop a tool that will aid clinicians in identifying unusual CGM behaviour and highlight CGM data that potentially need to be interpreted with care.MethodsCGM data and BG measurements from 50 infants at risk of hypoglycaemia were used. Unusual CGM measurements were classified using a stochastic model based on the kernel density method and historical CGM measurements from the cohort. CGM traces were colour coded with very unusual measurements coloured red, highlighting areas to be interpreted with care. A 5-fold validation of the model was Monte Carlo simulated 25 times to ensure an adequate model fit.ResultsThe stochastic model was generated using ~67,000 CGM measurements, spread across the glycaemic range ~2-10 mmol/L. A 5-fold validation showed a good model fit: the model 80% confidence interval (CI) captured 83% of clinical CGM data, the model 90% CI captured 91% of clinical CGM data, and the model 99% CI captured 99% of clinical CGM data. Three patient examples show the stochastic classification method in use with 1) A stable, low variability patient which shows no unusual CGM measurements, 2) A patient with a very sudden, short hypoglycaemic event (classified as unusual), and, 3) A patient with very high, potentially un-physiological, glycaemic variability after day 3 of monitoring (classified as very unusual).ConclusionsThis study has produced a stochastic model and classification method capable of highlighting unusual CGM behaviour. This method has the potential to classify important glycaemic events (e.g. hypoglycaemia) as true clinical events or sensor noise, and to help identify possible sensor degradation. Colour coded CGM traces convey the information quickly and efficiently, while remaining computationally light enough to be used retrospectively or in real-time.


Computer Methods and Programs in Biomedicine | 2014

Impact of sensor and measurement timing errors on model-based insulin sensitivity

Christopher G. Pretty; Matthew Signal; Liam M. Fisk; Sophie Penning; Aaron Le Compte; Geoffrey M. Shaw; Thomas Desaive; J. Geoffrey Chase

A model-based insulin sensitivity parameter (SI) is often used in glucose-insulin system models to define the glycaemic response to insulin. As a parameter identified from clinical data, insulin sensitivity can be affected by blood glucose (BG) sensor error and measurement timing error, which can subsequently impact analyses or glycaemic variability during control. This study assessed the impact of both measurement timing and BG sensor errors on identified values of SI and its hour-to-hour variability within a common type of glucose-insulin system model. Retrospective clinical data were used from 270 patients admitted to the Christchurch Hospital ICU between 2005 and 2007 to identify insulin sensitivity profiles. We developed error models for the Abbott Optium Xceed glucometer and measurement timing from clinical data. The effect of these errors on the re-identified insulin sensitivity was investigated by Monte-Carlo analysis. The results of the study show that timing errors in isolation have little clinically significant impact on identified SI level or variability. The clinical impact of changes to SI level induced by combined sensor and timing errors is likely to be significant during glycaemic control. Identified values of SI were mostly (90th percentile) within 29% of the true value when influenced by both sources of error. However, these effects may be overshadowed by physiological factors arising from the critical condition of the patients or other under-modelled or un-modelled dynamics. Thus, glycaemic control protocols that are designed to work with data from glucometers need to be robust to these errors and not be too aggressive in dosing insulin.


Journal of diabetes science and technology | 2014

Continuous Glucose Monitoring and Trend Accuracy News About a Trend Compass

Matthew Signal; Rebecca K. Gottlieb; Aaron Le Compte; J. Geoffrey Chase

Background: Continuous glucose monitoring (CGM) devices are being increasingly used to monitor glycemia in people with diabetes. One advantage with CGM is the ability to monitor the trend of sensor glucose (SG) over time. However, there are few metrics available for assessing the trend accuracy of CGM devices. Aim: The aim of this study was to develop an easy to interpret tool for assessing trend accuracy of CGM data. Methods: SG data from CGM were compared to hourly blood glucose (BG) measurements and trend accuracy was quantified using the dot product. Trend accuracy results are displayed on the Trend Compass, which depicts trend accuracy as a function of BG. A trend performance table and Trend Index (TI) metric are also proposed. The Trend Compass was tested using simulated CGM data with varying levels of error and variability, as well as real clinical CGM data. Results: The results show that the Trend Compass is an effective tool for differentiating good trend accuracy from poor trend accuracy, independent of glycemic variability. Furthermore, the real clinical data show that the Trend Compass assesses trend accuracy independent of point bias error. Finally, the importance of assessing trend accuracy as a function of BG level is highlighted in a case example of low and falling BG data, with corresponding rising SG data. Conclusions: This study developed a simple to use tool for quantifying trend accuracy. The resulting trend accuracy is easily interpreted on the Trend Compass plot, and if required, performance table and TI metric.


Journal of diabetes science and technology | 2015

Using Continuous Glucose Monitoring Data and Detrended Fluctuation Analysis to Determine Patient Condition A Review

Felicity Thomas; Matthew Signal; J. Geoffrey Chase

Patients admitted to critical care often experience dysglycemia and high levels of insulin resistance, various intensive insulin therapy protocols and methods have attempted to safely normalize blood glucose (BG) levels. Continuous glucose monitoring (CGM) devices allow glycemic dynamics to be captured much more frequently (every 2-5 minutes) than traditional measures of blood glucose and have begun to be used in critical care patients and neonates to help monitor dysglycemia. In an attempt to obtain a better insight relating biomedical signals and patient status, some researchers have turned toward advanced time series analysis methods. In particular, Detrended Fluctuation Analysis (DFA) has been a topic of many recent studies in to glycemic dynamics. DFA investigates the “complexity” of a signal, how one point in time changes relative to its neighboring points, and DFA has been applied to signals like the inter-beat-interval of human heartbeat to differentiate healthy and pathological conditions. Analyzing the glucose metabolic system with such signal processing tools as DFA has been enabled by the emergence of high quality CGM devices. However, there are several inconsistencies within the published work applying DFA to CGM signals. Therefore, this article presents a review and a “how-to” tutorial of DFA, and in particular its application to CGM signals to ensure the methods used to determine complexity are used correctly and so that any relationship between complexity and patient outcome is robust.

Collaboration


Dive into the Matthew Signal's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J.G. Chase

University of Canterbury

View shared research outputs
Top Co-Authors

Avatar

Hina Ismail

University of Canterbury

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge