Matthias C. Hofmann
Virginia Tech
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Matthias C. Hofmann.
Biomaterials | 2011
Bryce M. Whited; Jon Whitney; Matthias C. Hofmann; Yong Xu; Marissa Nichole Rylander
Electrospun polymer/apatite composite scaffolds are promising candidates as functional bone substitutes because of their ability to allow pre-osteoblast attachment, proliferation, and differentiation. However these structures usually lack an adequate pore size to permit sufficient cell migration and colonization of the scaffold. To overcome this limitation, we developed an apatite-coated electrospun PLLA scaffold with varying pore size and porosity by utilizing a three-step water-soluble PEO fiber inclusion, dissolution, and mineralization process. The temporal and spatial dynamics of cell migration into the scaffolds were quantified to determine the effects of enhanced pore size and porosity on cell infiltration. MC3T3-E1 pre-osteoblast migration into the scaffolds was found to be a function of both initial PEO content and time. Scaffolds with greater initial PEO content (50% and 75% PEO) had drastically accelerated cell infiltration in addition to enhanced cell distribution throughout the scaffold when compared to scaffolds with lower PEO content (0% and 25% PEO). Furthermore, scaffolds with an apatite substrate significantly upregulated MC3T3-E1 alkaline phosphatase activity, osteocalcin content, and cell-mediated mineralization as compared to PLLA alone. These findings suggest that such a scaffold enhances pre-osteoblast infiltration, colonization, and maturation in vitro and may lead to overall improved bone formation when implanted in vivo.
Optics Express | 2011
Chalongrat Daengngam; Matthias C. Hofmann; Zhiwen Liu; Anbo Wang; James R. Heflin; Yong Xu
We report the fabrication and characterization of a cylindrically symmetric fiber structure that possesses significant and thermodynamically stable second-order nonlinearity. Such fiber structure is produced through nanoscale self-assembly of nonlinear molecules on a silica fiber taper and possesses full rotational symmetry. Despite its highly symmetric configuration, we observed significant second harmonic generation (SHG) and obtained good agreement between experimental results and theoretical predictions.
PLOS ONE | 2013
Bryce M. Whited; Matthias C. Hofmann; Peng Lu; Yong Xu; Christopher G. Rylander; Ge Wang; Etai Sapoznik; Tracy Criswell; Sang Jin Lee; Shay Soker; Marissa Nichole Rylander
Bioengineering of vascular grafts holds great potential to address the shortcomings associated with autologous and conventional synthetic vascular grafts used for small diameter grafting procedures. Lumen endothelialization of bioengineered vascular grafts is essential to provide an antithrombogenic graft surface to ensure long-term patency after implantation. Conventional methods used to assess endothelialization in vitro typically involve periodic harvesting of the graft for histological sectioning and staining of the lumen. Endpoint testing methods such as these are effective but do not provide real-time information of endothelial cells in their intact microenvironment, rather only a single time point measurement of endothelium development. Therefore, nondestructive methods are needed to provide dynamic information of graft endothelialization and endothelium maturation in vitro. To address this need, we have developed a nondestructive fiber optic based (FOB) imaging method that is capable of dynamic assessment of graft endothelialization without disturbing the graft housed in a bioreactor. In this study we demonstrate the capability of the FOB imaging method to quantify electrospun vascular graft endothelialization, EC detachment, and apoptosis in a nondestructive manner. The electrospun scaffold fiber diameter of the graft lumen was systematically varied and the FOB imaging system was used to noninvasively quantify the affect of topography on graft endothelialization over a 7-day period. Additionally, results demonstrated that the FOB imaging method had a greater imaging penetration depth than that of two-photon microscopy. This imaging method is a powerful tool to optimize vascular grafts and bioreactor conditions in vitro, and can be further adapted to monitor endothelium maturation and response to fluid flow bioreactor preconditioning.
Journal of Biomedical Optics | 2011
Alexander X. Cong; Matthias C. Hofmann; Wenxiang Cong; Yong Xu; Ge Wang
Fluorescence microscopy allows real-time monitoring of optical molecular probes for disease characterization, drug development, and tissue regeneration. However, when a biological sample is thicker than 1 mm, intense scattering of light would significantly degrade the spatial resolution of fluorescence microscopy. In this paper, we develop a fluorescence microtomography technique that utilizes the Monte Carlo method to image fluorescence reporters in thick biological samples. This approach is based on an l(0)-regularized tomography model and provides an excellent solution. Our studies on biomimetic tissue scaffolds have demonstrated that the proposed approach is capable of localizing and quantifying the distribution of optical molecular probe accurately and reliably.
euro-american workshop on information optics | 2011
Matthias C. Hofmann; Bryce M. Whited; Aaron S. Goldstein; Joseph W. Freeman; Marissa Nichole Rylander; Chris Rylander; Mark E. Furth; Ge Wang; Shay Soker; Yong Xu
A major barrier for progress in regenerative medicine is the inability to observe the process of tissue regeneration non-destructively, in real time, and with cellular level resolution. In order to overcome this difficult challenge, we have proposed and developed an imaging-bioreactor system based on fiber micro-devices. Our system is based on directly incorporating multiple hollow core fibers (HCFs) into a biocompatible tissue scaffold. By inserting fiber-based micro-mirrors into the HCFs and applying a straightforward scanning-reconstruction algorithm, we have demonstrated an imaging resolution of ∼200 μm through an optically opaque scaffold.
ASME 2012 Summer Bioengineering Conference, Parts A and B | 2012
Bryce M. Whited; Matthias C. Hofmann; Peng Lu; Christopher G. Rylander; Shay Soker; Ge Wang; Yong Xu; Marissa Nichole Rylander
The clinical need for alternatives to autologous vein and artery grafts for small-diameter vascular reconstruction have led researches to a tissue-engineering approach. Bioengineered vascular grafts provide a mechanically robust conduit for blood flow while implanted autologous cells remodel the construct to form a fully functional vessel [1]. A typical tissue-engineering approach involves fabricating a vascular scaffold from natural or synthetic materials, seeding the lumen of a vessel with endothelial cells (EC) and the vessel wall with smooth muscle cells or fibroblasts to mimic the functional properties of a native vessel. The cell-seeded vascular scaffold is then preconditioned in vitro using a pulsatile bioreactor to mimic in vivo conditions to enhance vessel maturation before implantation (Fig. 1).Copyright
ASME 2012 Summer Bioengineering Conference, Parts A and B | 2012
Matthew DeWitt; Bryce M. Whited; Matthias C. Hofmann; Peng Lu; Yong Xu; Marissa Nichole Rylander
Laser based photothermal therapy is a minimally invasive technique that relies on the absorption of energy by an irradiated tissue sample and results in the deposition of heat to destroy cancerous cells. The inclusion of nanoparticles that act as intense infrared absorbers allows for higher selectivity and additional absorption of laser energy into heat in the desired material. One promising carbonaceous nanoparticle is single walled carbon nanohorns (SWNHs) which have been demonstrated to be effective photoabsorbers [1].Copyright
ASME 2011 Summer Bioengineering Conference, Parts A and B | 2011
Bryce M. Whited; Matthias C. Hofmann; Chris G. Rylander; Aaron S. Goldstein; Joseph W. Freeman; Mark E. Furth; Shay Soker; Ge Wang; Yong Xu; Marissa Nichole Rylander
The use of tissue engineered scaffolds in combination with progenitor cells has emerged as a promising strategy to restore or replace tissues damaged by disease or trauma. In addition to being biocompatible and exhibiting appropriate mechanical properties, scaffolds must be designed to sustain cell attachment, proliferation, and differentiation to ultimately produce the desired tissue once implanted in the patient [1]. Conventional techniques used to assess successful scaffold design include cell viability stains, DNA assays, and histological sectioning/staining. While significant information can be gained from using these methodologies, they are destructive to the sample and only provide snapshots of scaffold and cell development at a limited number of time points. Consequently, key temporal and spatial information relating to tissue regeneration in the scaffold is lost utilizing these techniques. Thus, the ability to non-destructively monitor cell viability, proliferation, and differentiation in real-time is of great importance for scaffold design and tissue engineering [2].Copyright
Tissue Engineering Part C-methods | 2012
Matthias C. Hofmann; Bryce M. Whited; Tracy Criswell; Marissa Nichole Rylander; Christopher G. Rylander; Shay Soker; Ge Wang; Yong Xu
Journal of Biomedical Optics | 2012
Matthias C. Hofmann; Bryce M. Whited; Josh Mitchell; William C. Vogt; Tracy Criswell; Christopher G. Rylander; Marissa Nichole Rylander; Shay Soker; Ge Wang; Yong Xu