Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Maurizio Marrale is active.

Publication


Featured researches published by Maurizio Marrale.


Radiation Research | 2011

Sensitivity of Alanine Dosimeters with Gadolinium Exposed to 6 MV Photons at Clinical Doses

Maurizio Marrale; Anna Longo; M. Spanò; A. Bartolotta; Maria Cristina D'Oca; Maria Brai

In this study we analyzed the ESR signal of alanine dosimeters with gadolinium exposed to 6 MV linear accelerator photons. We observed that the addition of gadolinium brings about an improvement in the sensitivity to photons because of its high atomic number. The experimental data indicated that the addition of gadolinium increases the sensitivity of the alanine to 6 MV photons. This enhancement was better observed at high gadolinium concentrations for which the tissue equivalence is heavily reduced. However, information about the irradiation setup and of the radiation beam features allows one to correct for this difference. Monte Carlo simulations were carried out to obtain information on the expected effect of the addition of gadolinium on the dose absorbed by the alanine molecules inside the pellets. These results are compared with the experimental values, and the agreement is discussed.


Radiation Research | 2009

Analysis of the Spatial Distribution of Free Radicals in Ammonium Tartrate by Pulse EPR Techniques

Maurizio Marrale; Maria Brai; Antonio Barbon; Marina Brustolon

Abstract Marrale, M., Brai, M., Barbon, A. and Brustolon, M. Analysis of the Spatial Distribution of Free Radicals in Ammonium Tartrate by Pulse EPR Techniques. Radiat. Res. 171, 349–359 (2009). Using pulse electron paramagnetic resonance (EPR) on a series of l(+)-ammonium tartrate (AT) dosimeters exposed to radiations with different linear energy transfer (LET), we assessed the ability of pulse EPR spectroscopy to discriminate the quality of various radiation beams such as 60Co γ-ray photons, protons and thermal neutrons at various doses by analyzing the local radical distributions produced by the different beams. We performed two types of pulse EPR investigations: two-pulse electron spin echo decay obtained by varying the microwave power, and a double electron-electron resonance (DEER) study. Both methods provide information about the dipolar interactions among the free radicals and about their spatial distributions. The first method provided information on the instantaneous diffusion and hence the microscopic concentration of the radicals that is compared with the macroscopic one obtained by CW-EPR. The DEER spectra yielded the distributions of distances between pairs of radicals two to five crystal cells apart produced by the same radiation event, a result reported here for the first time. The inter-radical distributions given by the DEER results have been simulated by modeling the radical distributions according to the details of the matter-radiation interactions for the various beams. The results of both types of pulse experiments are strongly dependent on the radiation quality. This was also observed for samples giving indistinguishable CW-EPR spectral profiles. We conclude that the pulse EPR measurements can be valuable tools for distinguishing the LET of the radiation beams, an important parameter for radiobiological considerations.


Physics in Medicine and Biology | 2007

Improvement of ESR dosimetry for thermal neutron beams through the addition of gadolinium

Maria Brai; Maurizio Marrale; G. Gennaro; A. Bartolotta; Maria Cristina D'Oca; G Rosi

In this paper, the addition of gadolinium is proposed as a useful tool to enhance the electron spin resonance (ESR) sensitivity of organic compounds to thermal neutrons. The target of this work is the detection, through the ESR technique, of the thermal neutron fluence in a mixed field of photons and neutrons. Gadolinium was chosen because it has a very high capture cross section to thermal neutrons; its nuclear reaction with thermal neutrons induces complex inner shell transitions that generate, besides other particles, Auger electrons, which in turn release their energy in the neighborhood (only several nanometers) of the place of reaction. Gadolinium was added to two organic molecules: alanine and ammonium tartrate. The main result obtained was a greater neutron sensitivity for dosimeters with gadolinium than for those without gadolinium for both organic molecules used. Since a dosimeter pair is required to discriminate between the two components of a mixed field, we studied the response of each dosimeter pair irradiated in a mixed field. Through a blind test we verified the usefulness of this dosimetric system and we obtained an estimate of the fluence in the mixed field with a relative uncertainty of 3%, when the pair composed of an alanine dosimeter and a dosimeter with alanine and gadolinium is used.


Applied Radiation and Isotopes | 2009

Monte Carlo simulation of the response of ESR dosimeters added with gadolinium exposed to thermal, epithermal and fast neutrons.

Maurizio Marrale; Salvatore Basile; Maria Brai; Anna Longo

Monte Carlo numerical calculations of the response of alanine and ammonium tartrate ESR (electron spin resonance) dosimeters exposed to neutron fields with different energy spectra are reported. Results have been obtained for various gadolinium concentrations inside the dosimeters. Furthermore, in order to simulate the in-phantom response we have carried out calculations by varying the depth of the dosimeter. We have found that a large enhancement is obtained for thermal neutrons, because of the very high capture cross section of gadolinium to thermal neutrons. A good enhancement was obtained for epithermal neutrons, whereas the sensitivity improvement in the case of fast neutron irradiation is poor. Furthermore, the simulations carried out by varying the depth suggests that an appreciable sensitivity to thermal and epithermal neutrons could be observed for in-phantom measurements in the 2-3 cm depth range. These results can provide useful insight for future experiments with epithermal neutron beams (such as those used in neutron capture therapy) and for future applications in neutron capture therapy dosimetry.


PLOS ONE | 2014

Assessing the Impact of Copy Number Variants on miRNA Genes in Autism by Monte Carlo Simulation

Maurizio Marrale; Nadia Ninfa Albanese; Francesco Calì; Valentino Romano

Autism Spectrum Disorders (ASDs) are childhood neurodevelopmental disorders with complex genetic origins. Previous studies have investigated the role of de novo Copy Number Variants (CNVs) and microRNAs as important but distinct etiological factors in ASD. We developed a novel computational procedure to assess the potential pathogenic role of microRNA genes overlapping de novo CNVs in ASD patients. Here we show that for chromosomes # 1, 2 and 22 the actual number of miRNA loci affected by de novo CNVs in patients was found significantly higher than that estimated by Monte Carlo simulation of random CNV events. Out of 24 miRNA genes over-represented in CNVs from these three chromosomes only hsa-mir-4436b-1 and hsa-mir-4436b-2 have not been detected in CNVs from non-autistic subjects as reported in the Database of Genomic Variants. Altogether the results reported in this study represent a first step towards a full understanding of how a dysregulated expression of the 24 miRNAs genes affect neurodevelopment in autism. We also propose that the procedure used in this study can be effectively applied to CNVs/miRNA genes association data in other genomic disorders beyond autism.


Radiation Research | 2014

Discrimination of Radiation Quality Through Second Harmonic Out-of- Phase cw-ESR Detection

Maurizio Marrale; Anna Longo; Maria Brai; Antonio Barbon; Marina Brustolon

The ability to discriminate the quality of ionizing radiation is important because the biological effects produced in tissue strongly depends on both absorbed dose and linear energy transfer (LET) of ionizing particles. Here we present an experimental electron spin resonance (ESR) analysis aimed at discriminating the effective LETs of various radiation beams (e.g., 19.3 MeV protons, 60Co photons and thermal neutrons). The measurement of the intensities of the continuous wave spectrometer signal channel first harmonic in-phase and the second harmonic out-of-phase components are used to distinguish the radiation quality. A computational analysis, was carried out to evaluate the dependence of the first harmonic in-phase and second harmonic out-of-phase components on microwave power, modulation amplitude and relaxation times, and highlights that these components could be used to point out differences in the relaxation times. On the basis of this numerical analysis the experimental results are discussed. The methodology described in this study has the potential to provide information on radiation quality.


Radiation Protection Dosimetry | 2014

Neutron ESR dosimetry through ammonium tartrate with low Gd content

Maurizio Marrale; Maria Brai; Anna Longo; Salvatore Panzeca; Luigi Tranchina; E. Tomarchio; A. Parlato; A. Buttafava; Daniele Dondi

This paper continues analyses on organic compounds for application in neutron dosimetry performed through electron spin resonance (ESR). Here, the authors present the results obtained by ESR measurements of a blend of ammonium tartrate dosemeters and gadolinium oxide (5 % by weight). The choice of low amount of Gd is due to the need of improving neutron sensitivity while not significantly influencing tissue equivalence. A study of the effect of gadolinium presence on tissue equivalence was carried out. The experiments show that the neutron sensitivity is enhanced by more than an order of magnitude even with this small additive content. Monte Carlo simulations on the increment of energy release due to gadolinium presence were carried, and the results were in good agreement with the experimental data.


Applied Radiation and Isotopes | 2015

Testing and linearity calibration of films of phenol compounds exposed to thermal neutron field for EPR dosimetry.

Salvatore Gallo; Salvatore Panzeca; Anna Longo; S. Altieri; A. Bentivoglio; Daniele Dondi; R.P. Marconi; Nicoletta Protti; Alberto Zeffiro; Maurizio Marrale

This paper reports the preliminary results obtained by Electron Paramagnetic Resonance (EPR) measurements on films of IRGANOX® 1076 phenols with and without low content (5% by weight) of gadolinium oxide (Gd2O3) exposed in the thermal column of the Triga Mark II reactor of LENA (Laboratorio Energia Nucleare Applicata) of Pavia (Italy). Thanks to their size, the phenolic films here presented are good devices for the dosimetry of beams with high dose gradient and which require accurate knowledge of the precise dose delivered. The dependence of EPR signal as function of neutron dose was investigated in the fluence range between 10(11) cm(-2) and 10(14) cm(-2). Linearity of EPR response was found and the signal was compared with that of commercial alanine films. Our analysis showed that gadolinium oxide (5% by weight) can enhance the thermal neutron sensitivity more than 18 times. Irradiated dosimetric films of phenolic compound exhibited EPR signal fading of about 4% after 10 days from irradiation.


Radiation Protection Dosimetry | 2014

EPR/alanine pellets with low Gd content for neutron dosimetry.

Maurizio Marrale; Maria Brai; Anna Longo; Salvatore Panzeca; Antonio Carlino; Luigi Tranchina; E. Tomarchio; A. Parlato; A. Buttafava; Daniele Dondi; Alberto Zeffiro

This paper reports on results obtained by electron paramagnetic resonance (EPR) measurements and Monte Carlo (MC) simulation on a blend of alanine added with low content of gadolinium oxide (5 % by weight) to improve the sensitivity to thermal neutron without excessively affecting tissue equivalence. The sensitivity is enhanced by this doping procedure of more an order of magnitude. The results are compared with those obtained with the addition of boric acid (50 % by weight) where boron is in its natural isotopic composition in order to produce low-cost EPR dosemeters. The gadolinium addition influences neutron sensitivity more than the boron addition. The presence of additives does not substantially change the fading of the EPR signal induced by neutrons. The MC simulations agree the experimental results in case of gadolinium addition.


Journal of Applied Physics | 2009

Electronic paramagnetic resonance power saturation of wooden samples

Maria Brai; Anna Longo; Antonella Maccotta; Maurizio Marrale

The deterioration of wood used for artifacts of artistic interest involves the production of different free radicals from the macromolecules of the wooden matrix (cellulose, lignin, and hemicellulose). Among the techniques able to provide information about these free radicals, the contribution of electronic paramagnetic resonance (EPR) can be very valuable. In this paper, the study of EPR signals (with g≈2) of both modern and ancient wooden taxa was undertaken in order to analyze some features of the free radicals in natural wood. In particular, we have studied the microwave power saturation behaviors of seasoned wooden samples from ten species, and we have found remarkable differences between softwoods and hardwoods. These differences can be correlated to dissimilarities in the relaxation times T1 and T2 attributable to the different microscopic structures of the two trees’ categories. The method has been also applied to ancient woods belonging to works of art in order to assess the conservation state of...

Collaboration


Dive into the Maurizio Marrale's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Salvatore Gallo

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge