Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Max Dieterich is active.

Publication


Featured researches published by Max Dieterich.


Annals of Surgery | 2009

The Oncological Safety of Skin Sparing Mastectomy with Conservation of the Nipple-Areola Complex and Autologous Reconstruction : An Extended Follow-Up Study

Bernd Gerber; Annette Krause; Max Dieterich; Günther Kundt; Toralf Reimer

Objective:To find out if skin sparing mastectomy (SSM) and nipple sparing mastectomy (NSM) with immediate autologous reconstruction as safe in oncological terms as modified radical mastectomy (MRM). Summary Background:The oncological safety of less radical surgical procedures like SSM and NSM cannot be evaluated by randomized trials. A careful and long lasting follow-up of patients, treated with SSM or NSM, is urgently needed. Patients and Methods:Between 1994–2000, 246 selected patients with an indication for MRM were treated with SSM, NSM, or MRM. Short term results were published in 2003.1 After a mean follow-up of 101 months (range 32–126), 238 evaluable patients with SSM (N = 48), NSM (N = 60), or MRM (N = 130) were analyzed for local and distant recurrences, breast cancer specific death, and esthetic results. Results:Local recurrences occurred in 10.4% (SSM), 11.7% (NSM) and 11.5% (MRM) of all patients (P = 0.974). With regard to isolated DM (25.0%, 23.3%, respectively 26.2%; P = 0.916) and breast cancer specific death (20.8%, 21.7%, respectively 21.5%; P = 0.993), there were no significant differences between subgroups. The re-evaluation of esthetic results by surgeons revealed a significant shift from 78.4% excellent results after 59 months to 47.9% after 101 months follow-up (SSM; P = 0.004) and from 73.8% to 51.7% (NSM; P = 0.025). An important risk factor for decreased cosmetic score was application of adjuvant radiotherapy. Conclusion:In patients who are candidates for a mastectomy, skin sparing mastectomy or nipple sparing mastectomy with immediate autologous reconstruction are oncologically safe techniques. Adjuvant radiotherapy decreases the esthetic results even after a longer period of time.


Plastic and Reconstructive Surgery | 2013

Implant-based breast reconstruction using a titanium-coated polypropylene mesh (TiLOOP Bra): a multicenter study of 231 cases.

Max Dieterich; Stefan Paepke; Karin Zwiefel; Holger Dieterich; Jens Uwe Blohmer; Andree Faridi; E Klein; Bernd Gerber; Carolin Nestle-Kraemling

Background: An alternative to implant-based breast reconstruction using acellular dermal matrix is the use of a titanium-coated polypropylene mesh. The mesh was approved for implant-based breast reconstruction in Europe in 2008, but only limited clinical data are available. Methods: Two hundred seven patients (231 breasts) with skin-sparing/nipple-sparing or modified radical mastectomy and immediate or delayed implant-based breast reconstruction using titanium-coated polypropylene mesh were evaluated retrospectively. The primary endpoints were identification of patient-related and surgical factors that were predictive for an adverse outcome and the development of recommendations for patients eligible for implant-based breast reconstruction using the mesh. Complications were divided into major (need for additional surgery), minor (conservative treatment), and implant loss. Univariate and multivariate logistic regression analyses were performed to determine the influence of the patient- and procedure-related characteristics on postoperative complications and implant loss. Results: No risk factors were observed for patient-associated complications. Major complications occurred in 13.4 percent, minor complications in 15.6 percent, and implant loss in 8.7 percent of patients. Univariate analysis revealed procedure-related risk factors for postoperative complications with a bilateral procedure (p = 0.013) or skin expansion before implant surgery (p = 0.043). Multivariate analysis confirmed these risk factors and revealed an increased risk for implant loss in patients with skin necrosis (p < 0.001) and capsule fibrosis (p < 0.001). Conclusions: This titanium-coated polypropylene mesh shows acceptable complication rates and can be a helpful device in implant-based breast reconstruction. The mesh should only be used in primary cases and, when adhering to the proposed indications, is a safe and convenient option in implant-based breast reconstruction. Clinical Question/Level of Evidence: Risk, III.


Ultraschall in Der Medizin | 2012

Differentiating between malignant and benign breast masses: factors limiting sonoelastographic strain ratio.

Angrit Stachs; Steffi Hartmann; Johannes Stubert; Max Dieterich; A. Martin; Günther Kundt; Toralf Reimer; Bernd Gerber

PURPOSE We compared strain ratio vs. qualitative elastography for the further differentiation of focal breast lesions, with special focus on limiting factors. MATERIALS AND METHODS 215 patients with 224 histologically proven breast masses (116 malignant, 108 benign) were prospectively examined using a high-end ultrasound system (Philips iU22) with serial elastography function. B-mode scans and available mammograms were reviewed according to the BIRADS classification, raw elastogram data was analyzed qualitatively using the Tsukuba score and semiquantitatively by calculating the strain ratio (fat to lesion ratio). For diagnostic performance, Receiver Operating Characteristic (ROC) curve analysis was obtained. A sub-group analysis regarding breast density, lesion size, lesion depth and histological subtypes was performed. RESULTS Mean strain ratio values were 3.04 ± 0.9 for malignant and 1.91 ± 0.75 for benign lesions (p < 0,001). The areas under the ROC curve values were 0.832 (95 % CI 0.777; 0.888) for strain ratio, 0.869 (95 % CI 0.822; 0.917) for Tsukuba score, 0.822 (95 % CI 0.768; 0.876) for B-mode ultrasound and 0.853 (95 % CI 0.799; 0.907) for mammography. Sensitivity, specificity, positive predictive value and negative predictive value of the strain ratio were 90.7 %, 58.2 %, 70.3 % and 85.1 %, when a cutoff point of 2.0 was used. Only lesion depth ≤ 4 mm was associated with diagnostic failure in the multivariate analysis of factors influencing accuracy, whereas no significant correlation between breast density and lesion size and the accuracy of the strain ratio could be found. CONCLUSION The addition of strain ratio to B-mode ultrasound increases specificity without loss of sensitivity in differentiating between malignant and benign breast tumors. Strain ratio measurements should not be carried out on tumors with a lesion depth ≤ 4 mm.


Ejso | 2012

A short-term follow-up of implant based breast reconstruction using a titanium-coated polypropylene mesh (TiLoop Bra)

Max Dieterich; Toralf Reimer; H. Dieterich; Johannes Stubert; Bernd Gerber

INTRODUCTION A new approach for implant based breast reconstruction (IBBR) is the use of a titanium-coated polypropylene mesh (TCPM) as an alternative to acellular dermal matrix (ADM). This TCPM has a good biocompatibility and can be used similarly to ADM. The aim of this study is to discuss indications, limitations and complications of TCPM in IBBR. METHODS A retrospective analysis of 42 patients undergoing immediate or delayed IBBR using a TCPM was performed. Primary endpoints were incidence of infection and expander/implant with mesh removal due to infected fluid collection or extrusion. RESULTS In two patients, mild hematoma, seroma or infection occurred. Skin necrosis or capsular contraction was observed in one patient. Mesh explantation was needed in 3 cases. These events were higher among the first cases and in patients with postoperative skin infection (p = 0.003). CONCLUSION In selected patients with adequate soft tissue cover TCPM seems to be a helpful tool for implant stabilization in terms of lateral stabilization and fixation of the musculus pectoralis major. In comparison to ADM, TCPM is cheaper and initial results are promising, but further follow-up data are necessary. In patients with poor soft tissue cover ADM should be used.


Breast Cancer Research and Treatment | 2011

Axillary lymph node dissection in early-stage invasive breast cancer: is it still standard today?

Bernd Gerber; Kristin Heintze; Johannes Stubert; Max Dieterich; Steffi Hartmann; Angrit Stachs; Toralf Reimer

Evaluation of axillary lymph node status by sentinel lymph node biopsy (SLNB) and complete axillary lymph node dissection (ALND) are an inherent part of breast cancer treatment. Increased understanding of tumor biology has changed the prognostic and therapeutic impact of lymph node status. Non-invasive imaging techniques like axillary ultrasound, FDG-PET, or MRI revealed moderate sensitivity and high specificity in evaluation of lymph node status. Therefore, they are not sufficient for lymph node staging. Otherwise, the impact of remaining micrometastases and even macrometastases for prognosis and treatment decisions is overestimated. Considering tumor biology, the distinction of axillary metastases in isolated tumor cells (ITC, pN0(i+)); micrometastases (pN1mi), and macrometastases (pN1a) is not comprehensible. Increasing data support the thesis that remaining axillary metastases neither increase the axillary recurrence rate nor decrease overall survival. It is doubtful that axillary tumor cells are capable to complete the complex multistep metastatic process. If applied, axillary metastases are sensitive to systemic treatment and are targeted by postoperative tangential breast irradiation. Therefore, the controversy about the clinical relevance of tumor cell clusters or micrometastases in SLN is a sophisticated but not contemporary discussion. Currently, there is no indication for axillary surgery in elderly patients with favorable tumors and clinically tumor-free lymph nodes. Nonetheless, a rational and evidence-based approach to the management of clinically and sonographically N0 patients with planned breast-conserving surgery and limited tumor size is needed now.


Archives of Gynecology and Obstetrics | 2012

Using a titanium-coated polypropylene mesh (TiLOOP® Bra) for implant-based breast reconstruction: case report and histological analysis

Max Dieterich; H. Dieterich; S. Timme; Toralf Reimer; Bernd Gerber; Johannes Stubert

In breast reconstruction (BR), autologous tissue is preferably used in patients who are not eligible for breast conserving therapy (BCT). With the improvement of surgical techniques and enhanced implant technology implantbased BR experiences new importance [1]. The invention of new materials like acellular dermal matrix (ADM) and the new titanium-coated polypropylene mesh (TCPM; TiLOOP Bra, pfm medical, Cologne, Germany) gives breast surgeons and patients new perspectives [2]. Disadvantages and difficulties of a subpectoral placement of the implant can be resolved through the use of supporting and covering materials like ADM or TCPM. These meshes provide additional cover to the skin in the lower lateral part of the breast where usually not enough muscle is available to completely cover the implant. Especially with the proven safety of skinand nipple-sparing mastectomy (SSM/NSM) and the introduction of mammography screening, immediate implant-based BR is emerging [3]. Additionally, the surgical extent and patients impairment by prosthesis reconstruction is much lower than that by autologous tissue. The use of ADM for immediate implant-based BR has been described before [4–9]. In this case, we present a patient undergoing implant-based BR using a TCPM.


Journal of Perinatal Medicine | 2014

Clinical differences between early- and late-onset severe preeclampsia and analysis of predictors for perinatal outcome

Johannes Stubert; Stefanie Ullmann; Max Dieterich; Doreen Diedrich; Toralf Reimer

Abstract Aims: To analyze the clinical differences between early- and late-onset cases of severe preeclampsia and to evaluate parameters that could help to predict perinatal outcome. Methods: Over a period of 6 years, all cases of severe preeclampsia (n=68) at our institution were included in a retrospective cohort analysis. Differences between early (<34 weeks, n=44) and late (≥34 weeks, n=24) onset of the disease were evaluated. Risk factors for low 5-min Apgar score (≤7), small-for-gestational-age (SGA) infants and neonatal acidosis (umbilical arterial pH <7.20) were identified and considered in a multiple logistic regression model. Results: Early- and late-onset severe preeclampsia differed from each other remarkably. Perinatal outcome was unfavorable in early-onset disease and seemed to be mainly a result of premature delivery and development of fetal growth restriction. Abnormal uterine Doppler velocimetry increased the risk of low 5-min Apgar values [odds ratio (OR) 8.0, P=0.012] and preterm birth <34+0 weeks (OR 17.9, P<0.001). An increased resistance of the umbilical artery was associated with a higher risk for SGA birth weight (OR 4.9, P=0.010). Conclusion: Preeclampsia is a heterogeneous syndrome even if only severe cases were analyzed. Abnormal Doppler flow characteristics facilitated the identification of patients who were at increased risk for worse perinatal outcome.


Archives of Gynecology and Obstetrics | 2015

Biocompatibility, cell growth and clinical relevance of synthetic meshes and biological matrixes for internal support in implant-based breast reconstruction

Max Dieterich; Johannes Stubert; Bernd Gerber; Toralf Reimer; Dagmar-Ulrike Richter

PurposeBiological matrixes and synthetic meshes are increasingly used in implant-based breast reconstruction (IBBR). The objective was to test different materials used for internal support in IBBR in regards to biocompatibility and discuss possible limitations in a clinical context.Materials and methodsIn vitro investigations were performed on four relevant cell lines: Normal Human Dermal Fibroblasts (NHDF), Human White Preadipocytes (HWP), Endothelial cells (HDMEC) and Skeletal muscle cells (SkMC). A titanium-coated polypropylene mesh (TiLOOP® Bra), a partially resorbable mesh (SERAGYN BR®) and a porcine derived biologic matrix (Strattice™) were investigated. Test of cytotoxicity, cell proliferation and oxidative stress was performed. Real-time cell analysis was used to determine adhesion rate. Light- and scanning electron microscopy investigated cell migration.ResultsNo relevant cytotoxicity was detected for any mesh or matrix. Good cell proliferation was observed in all materials with best results for NHDF and SkMC. For HWP and HDMEC decreased proliferation and adherence to the synthetic meshes and biologic matrix were observed. Real-time cell analysis of fibroblasts incubated with the corresponding material, showed increased impedance for the synthetic meshes. A morphologic cell change was observed within all materials. Scanning electron microscopy showed good cell penetration into the meshes and matrix. The material compositions did not seem to influence the clinical outcome, although the biological matrix was much thicker compared to the synthetic meshes.ConclusionBiochemical examination showed good biocompatibility for the investigated meshes and matrix. All products seem to have their value in IBBR and can be recommended for IBBR.


Breast Care | 2014

Medical Prevention of Breast Cancer

Johannes Stubert; Max Dieterich; Bernd Gerber

Breast cancer is the most common cancer of women in Western Europe and North America. Effective strategies of medical prevention could reduce the burden of breast cancer mortality. The best evidence for a risk reduction exists for hormonal agents such as tamoxifen and raloxifene (22-72%) or aromatase inhibitors (50-65%). However, the severity of side effects and the lack of evidence for an improved survival compromise the risk/benefit balance. In this review the results of chemoprevention studies, including new treatment approaches, are summarized with critical discussion of their use in clinical practice.


Hypertension in Pregnancy | 2014

miRNA expression profiles determined in maternal sera of patients with HELLP syndrome

Johannes Stubert; Dirk Koczan; Dagmar-Ulrike Richter; Max Dieterich; Björn Ziems; Hans-Jürgen Thiesen; Bernd Gerber; Toralf Reimer

Objective: Syndrome of hemolysis, elevated liver enzymes and low platelets (HELLP) represents a distinct subgroup of severe preeclampsia. The aim of our study was to identify differentially expressed miRNAs in sera of patients with HELLP syndrome in comparison to unaffected controls. Study design: Blood samples were obtained from patients with manifest HELLP syndrome and matched unaffected controls. The expression of 754 mature miRNAs was assessed using the TaqMan Array format (n = 12). Results of seven differentially expressed miRNAs were further validated by single quantitative real-time polymerase chain reaction (qPCR) assays. Results: Serum miRNA analysis allowed detection of maternal and fetal miRNAs. Distinct miRNA expressions were confirmed for miR-122, miR-758 and miR-133a represented by a median up-regulation ≥two-fold in the HELLP group. The liver specific miR-122 was 11.5-fold increased with an area under curve (AUC) of 0.82 in the receiver operating characteristic (ROC) analysis. Cluster analyses of our data uncovered subgroups of HELLP patients were associated with clinical subtypes and differences in organ manifestation. Conclusion: In our proof of principle study, we demonstrated that patients with HELLP syndrome showed alterations of serum miRNA expression patterns. Data analysis goes along with the hypothesis that HELLP syndrome is regarded to be a heterogeneous disease.

Collaboration


Dive into the Max Dieterich's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

B. Gerber

Paul Ehrlich Institute

View shared research outputs
Researchain Logo
Decentralizing Knowledge