Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Mee-Kyoung Son is active.

Publication


Featured researches published by Mee-Kyoung Son.


The Journal of Advanced Prosthodontics | 2010

Anthropometric analysis of maxillary anterior buccal bone of Korean adults using cone-beam CT

Seung-Lok Lee; Hee-Jung Kim; Mee-Kyoung Son; Chae-Heon Chung

PURPOSE The aim of this study was to evaluate the thickness of buccal and palatal alveolar bone and buccal bony curvature below root apex in maxillary anterior teeth of Korean adults using Cone-beam CT images. MATERIALS AND METHODS The 3D image was reconstructed with dicom file obtained through CBCT from 20 - 39 year old Korean subjects (n = 20). The thickness of buccal and palatal plate, root diameter, the buccal bony curvature angle below root apex and the distance from root apex to the deepest point of buccal bony curvature were measured on maxillary anterior teeth area using OnDemand3D program. RESULTS Mean thickness of buccal plate 3 mm below CEJ was 0.68 ± 0.29 mm at central incisor, 0.76 ± 0.59 mm at lateral incisor, and 1.07 ± 0.80 mm at canine. Mean thickness of palatal plate 3 mm below CEJ was 1.53 ± 0.55 mm of central incisor, 1.18 ± 0.66 mm of lateral incisor, 1.42 ± 0.77 mm of canine. Bucco-lingual diameter 3 mm below CEJ was 5.13 ± 0.37 mm of central incisor, 4.58 ± 0.46 mm of lateral incisor, and 5.93 ± 0.47 mm of canine. Buccal bony curvature angle below root apex was 134.7 ± 17.5° at central incisor, 151.0 ± 13.9° at lateral incisor, 153.0 ± 9.5° at canine. Distance between root apex and the deepest point of buccal bony curvature of central incisor was 3.67 ± 1.28 mm at central incisor, 3.90 ± 1.51 mm at lateral incisor, and 5.13 ± 1.70 mm at canine. CONCLUSION Within the limitation of this study in Korean adults, the thickness of maxillary anterior buccal plate was very thin within 1mm and the thickness of palatal plate was thick, relatively. The buccal bony curvature below root apex of maxillary central incisor was higher than that of lateral incisor and canine and it seems that the buccal bony plate below root apex of central incisor is most curved.


The Journal of Advanced Prosthodontics | 2013

Effect of various intraoral repair systems on the shear bond strength of composite resin to zirconia

In-Hae Han; Dong-Wan Kang; Chae-Heon Chung; Han-Cheol Choe; Mee-Kyoung Son

PURPOSE This study compared the effect of three intraoral repair systems on the bond strength between composite resin and zirconia core. MATERIALS AND METHODS Thirty zirconia specimens were divided into three groups according to the repair method: Group I- CoJet™ Repair System (3M ESPE) [chairside silica coating with 30 µm SiO2 + silanization + adhesive]; Group II- Ceramic Repair System (Ivoclar Vivadent) [etching with 37% phosphoric acid + Zirconia primer + adhesive]; Group III- Signum Zirconia Bond (Heraus) [Signum Zirconia Bond I + Signum Zirconia Bond II]. Composite resin was polymerized on each conditioned specimen. The shear bond strength was tested using a universal testing machine, and fracture sites were examined with FE-SEM. Surface morphology and wettability after surface treatments were examined additionally. The data of bond strengths were statistically analyzed with one-way ANOVA and Tamhane post hoc test (α=.05). RESULTS Increased surface roughness and the highest wettability value were observed in the CoJet sand treated specimens. The specimens treated with 37% phosphoric acid and Signum Zirconia Bond I did not show any improvement of surface irregularity, and the lowest wettability value were found in 37% phosphoric acid treated specimens. There was no significant difference in the bond strengths between Group I (7.80 ± 0.76 MPa) and III (8.98 ± 1.39 MPa). Group II (3.21 ± 0.78 MPa) showed a significant difference from other groups (P<.05). CONCLUSION The use of Intraoral silica coating system and the application of Signum Zirconia Bond are effective for increasing the bond strength of composite resin to zirconia.


Implant Dentistry | 2014

Reliability of 2 implant stability measuring methods in assessment of various periimplant bone loss: an in vitro study with the Periotest and Osstell Mentor.

Han-Hee Choi; Chae-Heon Chung; Su-Gwan Kim; Mee-Kyoung Son

Purpose:The aim of this in vitro study was to evaluate reliability of the Periotest and Osstell Mentor in assessment of periimplant vertical and circular bone loss. Materials and Methods:Sixteen dental implants were embedded into acrylic resin blocks. The portion of resin around the implant neck was successively removed to mimic periimplant vertical and circular bone loss. Measurement values of 2 devices were compared by assessing the change of Periotest value (PTV) and Implant Stability Quotient (ISQ) values, by calculating correlation analysis and by means of regression analysis referring to increasing bone loss. Results:Both devices were able to discriminate differences of circular bone loss. However, PTVs were not noticeably changed in buccal, buccal-mesial, and buccal-mesial-distal bone loss. The differences in buccal and buccal-mesial bone loss were not discriminated by Osstell Mentor. As the range of bone loss was increased, there was a noticeable correlation of the PTV and ISQ values. Conclusions:The results of this study suggest that both diagnostic devices for implant stability are useful in detecting the circular bone loss. However, the clinical reliability of both devices for detecting the partial vertical bone loss is low.


Journal of Periodontal & Implant Science | 2011

Gingival recontouring by provisional implant restoration for optimal emergence profile: report of two cases

Mee-Kyoung Son; Hyun-Seon Jang

Purpose The emergence profile concept of an implant restoration is one of the most important factors for the esthetics and health of peri-implant soft tissue. This paper reports on two cases of gingival recontouring by the fabrication of a provisional implant restoration to produce an optimal emergence profile of a definitive implant restoration. Methods After the second surgery, a preliminary impression was taken to make a soft tissue working cast. A provisional crown was fabricated on the model. The soft tissue around the implant fixture on the model was trimmed with a laboratory scalpel to produce the scalloped gingival form. Light curing composite resin was added to fill the space between the provisional crown base and trimmed gingiva. After 4 to 6 weeks, the final impression was taken to make a definitive implant restoration, where the soft tissue and tooth form were in harmony with the adjacent tooth. Results At the first insertion of the provisional restoration, gum bleaching revealed gingival pressure. Four to six weeks after placing the provisional restoration, the gum reformed with harmony between the peri-implant gingiva and adjacent dentition. Conclusions Gingival recontouring with a provisional implant restoration is a non-surgical and non-procedure-sensitive method. The implant restoration with the optimal emergence profile is expected to provide superior esthetic and functional results.


The Journal of Advanced Prosthodontics | 2009

Abrasion of abutment screw coated with TiN

Seok-Won Jung; Mee-Kyoung Son; Chae-Heon Chung; Hee-Jung Kim

STATEMENT OF PROBLEM Screw loosening has been a common complication and still reported frequently. PURPOSE The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.


The Journal of Advanced Prosthodontics | 2016

Antimicrobial, Antioxidant and Cytotoxic Activities of Dendropanax morbifera Léveille extract for mouthwash and denture cleaning solution

Ryeo-Woon Kim; Sook-Young Lee; Su-Gwan Kim; Yu-Ri Heo; Mee-Kyoung Son

PURPOSE The purpose of this study was to analyze the antimicrobial, antioxidant activity and cytotoxicity of Dendropanax morbifera Léveille extract for assessing whether Dendropanax morbifera Léveille can be used for the development of natural mouthwash and denture cleaning solution. MATERIALS AND METHODS The extract was obtained from branches of Dendropanax morbifera Léveille. The solvent fractions were acquired by fractionating Dendropanax morbifera Léveille extract using n-hexane, ethyl acetate, chloroform and butanol solvent. Paper disc test was used to evaluate the antimicrobial and antifungal activity of Dendropanax morbifera Léveille extract and solvent fractions against Streptococcus mutans and Candida albicans. The analysis of antioxidant activity was carried out through DPPH radical scavenging assay. The cytotoxicity of Dendropanax morbifera Léveille extract was analyzed through MTT assay using normal human oral keratinocytes. RESULTS Dendropanax morbifera Léveille extract showed antimicrobial activity against Streptococcus mutans and especially Candida albicans. The solvent fractions of Dendropanax morbifera Léveille showed strong antimicrobial activity against Streptococcus mutans and Candida albicans in n-hexane and butanol solvent fraction, respectively. Dendropanax morbifera Léveille extract also showed outstanding antioxidant activity. Butanol, ethyl acetate, and chloroform solvent fraction of Dendropanax morbifera Léveille tended to have increased antioxidant activity as the concentration increased. Dendropanax morbifera Léveille extract showed high cell survival rate in cytotoxicity test. CONCLUSION Dendropanax morbifera Léveille extract turned out to have antimicrobial, antioxidant activity and cytophilicity. Based on these results, it is expected that Dendropanax morbifera Léveille is applicable as an ingredient for natural mouthwash and denture cleanser.


The Journal of Advanced Prosthodontics | 2015

Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

Dae-Eun Jang; Ji-Young Lee; Hyun-Seon Jang; Jang-Jae Lee; Mee-Kyoung Son

PURPOSE The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. RESULTS All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. CONCLUSION Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed.


Transactions of Nonferrous Metals Society of China | 2009

Electrochemical behavior of dental implant system before and after clinical use

Chae-Heon Chung; Hee-Jung Kim; Yong-Tae Jeong; Mee-Kyoung Son; Yong-Hoon Jeong; Han-Cheol Choe

Abstract Electrochemical behavior of dental implant system before and after clinical use (in vivo and in vitro) was researched by using abutment and titanium fixture. To simulate an oral environment, the samples of clinically used and non-used implant systems as a working electrode were exposed to artificial saliva at (36.5±1) °C. Electrochemical tests were carried out using a potentiostat. After electrochemical test, the corrosion morphology of each sample was investigated by FE-SEM and EDS. The corrosion potential and pitting potential of clinically used implant system are lower than those of non-used implant system, and clinically used implant system exhibits a lower range of passivation, indicating a less degree of inherent resistance against chloride ion. The polarization resistance decreases in the case of clinically used implant system, whereas, R p for clinically non-used implant system increases compared with clinically used implant system.


The Journal of Advanced Prosthodontics | 2015

Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.

Seok-Gyu Kim; Chae-Heon Chung; Mee-Kyoung Son

PURPOSE The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.


The Journal of Advanced Prosthodontics | 2009

Sinking and fit of abutment of locking taper implant system

Seung-Jin Moon; Hee-Jung Kim; Mee-Kyoung Son; Chae-Heon Chung

STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each loads step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.

Collaboration


Dive into the Mee-Kyoung Son's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge