Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Meng P. Chiao is active.

Publication


Featured researches published by Meng P. Chiao.


Proceedings of SPIE | 2016

The Astro-H High Resolution Soft X-Ray Spectrometer

Richard L. Kelley; Hiroki Akamatsu; Phillipp Azzarell; Tom Bialas; Gregory V. Brown; Edgar Canavan; Meng P. Chiao; E. Costantini; Michael DiPirro; Megan E. Eckart; Yuichiro Ezoe; Ryuichi Fujimoto; D. Haas; Jan Willem den Herder; Akio Hoshino; Kumi Ishikawa; Yoshitaka Ishisaki; Naoko Iyomoto; Caroline A. Kilbourne; Mark O. Kimball; Shunji Kitamoto; Saori Konami; Shu Koyama; Maurice A. Leutenegger; Dan McCammon; Joseph Miko; Kazuhisa Mitsuda; Ikuyuki Mitsuishi; Harvey Moseley; Hiroshi Murakami

We present the overall design and performance of the Astro-H (Hitomi) Soft X-Ray Spectrometer (SXS). The instrument uses a 36-pixel array of x-ray microcalorimeters at the focus of a grazing-incidence x-ray mirror Soft X-Ray Telescope (SXT) for high-resolution spectroscopy of celestial x-ray sources. The instrument was designed to achieve an energy resolution better than 7 eV over the 0.3-12 keV energy range and operate for more than 3 years in orbit. The actual energy resolution of the instrument is 4-5 eV as demonstrated during extensive ground testing prior to launch and in orbit. The measured mass flow rate of the liquid helium cryogen and initial fill level at launch predict a lifetime of more than 4 years assuming steady mechanical cooler performance. Cryogen-free operation was successfully demonstrated prior to launch. The successful operation of the SXS in orbit, including the first observations of the velocity structure of the Perseus cluster of galaxies, demonstrates the viability and power of this technology as a tool for astrophysics.


Proceedings of SPIE | 2016

The design, implementation, and performance of the Atro-H SXS calorimeter array and anti-coincidence detector

Caroline A. Kilbourne; Joseph S. Adams; Regis P. Brekosky; James A. Chervenak; Meng P. Chiao; Megan E. Eckart; E. Figueroa-Feliciano; M. Galeazzi; Christoph H. Grein; Richard L. Kelley; Daniel P. Kelly; Maurice A. Leutenegger; Dan McCammon; F. Scott Porter; Andrew E. Szymkowiak; Tomomi Watanabe; J. Zhao

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS has a square array of 36 microcalorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistorbearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance.


Proceedings of SPIE | 2016

In-orbit operation of the ASTRO-H SXS

Masahiro Tsujimoto; Kazuhisa Mitsuda; Richard L. Kelley; Jan Willem den Herder; Hiroki Akamatsu; Thomas G. Bialas; Gregory V. Brown; Meng P. Chiao; E. Costantini; Cor P. de Vries; Michael DiPirro; Megan E. Eckart; Yuichiro Ezoe; Ryuichi Fujimoto; D. Haas; Akio Hoshino; Kumi Ishikawa; Yoshitaka Ishisaki; Naoko Iyomoto; Caroline A. Kilbourne; Shunji Kitamoto; Shu Koyama; Maurice A. Leutenegger; Dan McCammon; Ikuyuki Mitsuishi; Hiroshi Murakami; Masahide Murakami; Hirofumi Noda; Mina Ogawa; Naomi Ota

We summarize all the in-orbit operations of the Soft X-ray Spectrometer (SXS) onboard the ASTRO-H (Hit- omi) satellite. The satellite was launched on 2016/02/17 and the communication with the satellite ceased on 2016/03/26. The SXS was still in the commissioning phase, in which the setups were progressively changed. This article is intended to serve as a reference of the events in the orbit to properly interpret the SXS data taken during its short life time, and as a test case for planning the in-orbit operation for future micro-calorimeter missions.


Proceedings of SPIE | 2016

Performance of the helium dewar and cryocoolers of ASTRO-H SXS

Ryuichi Fujimoto; Yoh Takei; Kazuhisa Mitsuda; Noriko Y. Yamasaki; Masahiro Tsujimoto; Shu Koyama; Kumi Ishikawa; Hiroyuki Sugita; Yoichi Sato; Keisuke Shinozaki; Atsushi Okamoto; Shunji Kitamoto; Akio Hoshino; Kosuke Sato; Yuichiro Ezoe; Yoshitaka Ishisaki; S. Yamada; Hiromi Seta; Takaya Ohashi; Toru Tamagawa; Hirofumi Noda; Makoto Sawada; Makoto Tashiro; Yoichi Yatsu; Ikuyuki Mitsuishi; Kenichi Kanao; Seiji Yoshida; Mikio Miyaoka; Shoji Tsunematsu; Kiyomi Otsuka

The Soft X-ray Spectrometer (SXS) is a cryogenic high-resolution X-ray spectrometer onboard the ASTRO-H satellite, that achieves energy resolution better than 7 eV at 6 keV, by operating the detector array at 50 mK using an adiabatic demagnetization refrigerator. The cooling chain from room temperature to the ADR heat sink is composed of 2-stage Stirling cryocoolers, a 4He Joule-Thomson cryocooler, and super uid liquid He, and is installed in a dewar. It is designed to achieve a helium lifetime of more than 3 years with a minimum of 30 liters. The satellite was launched on 2016 February 17, and the SXS worked perfectly in orbit, until March 26 when the satellite lost its function. It was demonstrated that the heat load on the He tank was about 0.7 mW, which would have satisfied the lifetime requirement. This paper describes the design, results of ground performance tests, prelaunch operations, and initial operation and performance in orbit of the flight dewar and cryocoolers.


Proceedings of SPIE | 2016

In-flight performance of the Soft X-ray Spectrometer detector system on Astro-H

F. S. Porter; Meng P. Chiao; Megan E. Eckart; Ryuichi Fujimoto; Yoshitaka Ishisaki; Richard L. Kelley; Caroline A. Kilbourne; Maurice A. Leutenegger; Dan McCammon; Kazuhisa Mitsuda; Kosuke Sato; Hiromi Seta; Makoto Sawada; Gary A. Sneiderman; Andrew E. Szymkowiak; Yoh Takei; Makoto Tashiro; Masahiro Tsujimoto; Tomomi Watanabe; S. Yamada

The SXS instrument was launched aboard the Astro-H observatory on February 17, 2016. The SXS spectrometer is based on a high sensitivity x-ray calorimeter detector system that has been successfully deployed in many ground and sub-orbital spectrometers. The instrument was to provide essential diagnostics for nearly every class of x-ray emitting objects from the atmosphere of Jupiter to the outskirts of galaxy clusters, without degradation for spatially extended objects. The SXS detector system consisted of a 36-pixel cryogenic microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the detector system demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous band-pass from below 0.3 keV to above 12 keV with a timing precision better than 100 μs. In addition, a solid-state anti-coincidence detector was placed directly behind the detector array for background suppression. The detector error budget included the measured interference from the SXS cooling system and the spacecraft. Additional margin for on-orbit gain-stability, and on-orbit spacecraft interference were also included predicting an on-orbit performance that meets or exceeds the 7 eV FWHM at 6 keV requirement. The actual on-orbit spectral resolution was better than 5 eV FWHM at 6 keV, easily satisfying the instrument requirement. Here we discuss the actual on-orbit performance of the SXS detector system and compare this to performance in pre-flight testing and the on-orbit predictions. We will also discuss the on-orbit gain stability, additional on-orbit interference, and measurements of the on-orbit background.


Proceedings of SPIE | 2016

In-flight performance of pulse processing system of the ASTRO-H soft x-ray spectrometer

Yoshitaka Ishisaki; S. Yamada; Hiromi Seta; Makoto Tashiro; Sawako Takeda; Yukikatsu Terada; Yuka Kato; Masahiro Tsujimoto; Shu Koyama; Kazuhisa Mitsuda; Makoto Sawada; Meng P. Chiao; Tomomi Watanabe; Maurice A. Leutenegger; Megan E. Eckart; F. Scott Porter; Caroline A. Kilbourne; Richard L. Kelley

We summarize results of the initial in-orbit performance of the pulse shape processor (PSP) of the soft x-ray spectrometer instrument onboard ASTRO-H (Hitomi). Event formats, kind of telemetry, and the pulse processing parameters are described, and the parameter settings in orbit are listed. PSP was powered-on two days after launch, and the event threshold was lowered in orbit. PSP worked fine in orbit, and there were no memory error nor SpaceWire communication error until the break-up of spacecraft. Time assignment, electrical crosstalk, and the event screening criteria are studied. It is confirmed that the event processing rate at 100% CPU load is ~200 c/s/array, compliant with the requirement on PSP.


Proceedings of SPIE | 2016

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

Caroline A. Kilbourne; Joseph S. Adams; Petar Arsenovic; Travis Ayers; Meng P. Chiao; Michael DiPirro; Megan E. Eckart; Ryuichi Fujimoto; John D. Kazeva; Richard L. Kelley; Kari L. Kripps; Bruce Lairson; Maurice A. Leutenegger; Heidi Lopez; Dan McCammon; Daniel S. McGuinness; Kazuhisa Mitsuda; Samuel J. Moseley; F. S. Porter; Andrea N. Schweiss; Yoh Takei; Rosemary S. Thorpe; Tomomi Watanabe; Noriko Y. Yamasaki; Seiji Yoshida

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The properties that make the SXS array a powerful x-ray spectrometer also make it sensitive to photons from the entire electromagnetic band, and particles as well. If characterized as a bolometer, it would have a noise equivalent power (NEP) of < 4x10-18 W/(Hz)0.5. Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. Both of these needs are addressed by a series of five thin-film radiation-blocking filters, anchored to the nested temperature stages, that block long-wavelength radiation while minimizing x-ray attenuation. The aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three outer filters also have been equipped with thermometers and heaters for decontamination. We present the requirements, design, implementation, and performance of the SXS aperture assembly and blocking filters.


Proceedings of SPIE | 2016

Vibration isolation system for cryocoolers of Soft X-ray Spectrometer (SXS) onboard ASTRO-H (Hitomi)

Yoh Takei; Susumu Yasuda; Kosei Ishimura; Naoko Iwata; Atsushi Okamoto; Yoichi Sato; Mina Ogawa; Makoto Sawada; Taro Kawano; Shingo Obara; Chikara Natsukari; Atsushi Wada; S. Yamada; Ryuichi Fujimoto; Motohide Kokubun; Noriko Y. Yamasaki; Hiroyuki Sugita; Kenji Minesugi; Yasuo Nakamura; Kazuhisa Mitsuda; Tadayuki Takahashi; Seiji Yoshida; Shoji Tsunematsu; Kenichi Kanao; Katsuhiro Narasaki; Kiyomi Otsuka; Richard L. Kelley; F. Scott Porter; Caroline A. Kilbourne; Meng P. Chiao

Soft X-ray Spectrometer (SXS) onboard ASTRO-H (named Hitomi after launch) is a microcalorimeter-type spectrometer, installed in a dewar to be cooled at 50 mK. The energy resolution of the SXS engineering model suffered from micro-vibration from cryocoolers mounted on the dewar. This is mitigated for the flight model by introducing vibration isolation systems between the cryocoolers and the dewar. The detector performance of the flight model was verified before launch of the spacecraft in both ambient condition and thermal-vac condition, showing no detectable degradation in energy resolution. The in-orbit performance was also consistent with that on ground, indicating that the cryocoolers were not damaged by launch environment. The design and performance of the vibration isolation system along with the mechanism of how the micro-vibration could degrade the cryogenic detector is shown.


Proceedings of SPIE | 2016

In-flight verification of the calibration and performance of the ASTRO-H (Hitomi) Soft X-Ray Spectrometer

Maurice A. Leutenegger; Marc Audard; Gregory V. Brown; Meng P. Chiao; Megan E. Eckart; Ryuichi Fujimoto; Akihiro Furuzawa; Matteo Guainazzi; D. Haas; Jan-Willem den Herder; Takayuki Hayashi; Ryo Iizuka; Manabu Ishida; Yoshitaka Ishisaki; Richard L. Kelley; Naomichi Kikuchi; Caroline A. Kilbourne; Shu Koyama; Sho Kurashima; Yoshitomo Maeda; Maxim Markevitch; Dan McCammon; Kazuhisa Mitsuda; Hideyuki Mori; Nozomi Nakaniwa; Takashi Okajima; Stephane Paltani; Robert Petre; F. Scott Porter; Kosuke Sato

The Soft X-ray Spectrometer (SXS) onboard the Astro-H (Hitomi) orbiting x-ray observatory featured an array of 36 silicon thermistor x-ray calorimeters optimized to perform high spectral resolution x-ray imaging spectroscopy of astrophysical sources in the 0.3-12 keV band. Extensive pre- flight calibration measurements are the basis for our modeling of the pulse-height-energy relation and energy resolution for each pixel and event grade, telescope collecting area, detector efficiency, and pulse arrival time. Because of the early termination of mission operations, we needed to extract the maximum information from observations performed only days into the mission when the onboard calibration sources had not yet been commissioned and the dewar was still coming into thermal equilibrium, so our technique for reconstructing the per-pixel time-dependent pulse-height-energy relation had to be modified. The gain scale was reconstructed using a combination of an absolute energy scale calibration at a single time using a fiducial from an onboard radioactive source, and calibration of a dominant time-dependent gain drift component using a dedicated calibration pixel, as well as a residual time-dependent variation using spectra from the Perseus cluster of galaxies. The energy resolution was also measured using the onboard radioactive sources. It is consistent with instrument-level measurements accounting for the modest increase in noise due to spacecraft systems interference. We use observations of two pulsars to validate our models of the telescope area and detector efficiency, and to derive a more accurate value for the thickness of the gate valve Be window, which had not been opened by the time mission operations ceased. We use observations of the Crab pulsar to refine the pixel-to-pixel timing and validate the absolute timing.


Review of Scientific Instruments | 2015

Invited article: First flight in space of a wide-field-of-view soft x-ray imager using lobster-eye optics: Instrument description and initial flight results

M. R. Collier; Frederik S. Porter; David G. Sibeck; J. A. Carter; Meng P. Chiao; Dennis J. Chornay; T. E. Cravens; M. Galeazzi; John W. Keller; Dimitra Koutroumpa; Joseph Kujawski; K. D. Kuntz; A. M. Read; Ina P. Robertson; Steve Sembay; Steven L. Snowden; Nicholas Thomas; Y. Uprety; B. M. Walsh

We describe the development, launch into space, and initial results from a prototype wide field-of-view soft X-ray imager that employs lobster-eye optics and targets heliophysics, planetary, and astrophysics science. The sheath transport observer for the redistribution of mass is the first instrument using this type of optics launched into space and provides proof-of-concept for future flight instruments capable of imaging structures such as the terrestrial cusp, the entire dayside magnetosheath from outside the magnetosphere, comets, the Moon, and the solar wind interaction with planetary bodies like Venus and Mars [Kuntz et al., Astrophys. J. (in press)].

Collaboration


Dive into the Meng P. Chiao's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Megan E. Eckart

Goddard Space Flight Center

View shared research outputs
Top Co-Authors

Avatar

Richard L. Kelley

Goddard Space Flight Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kazuhisa Mitsuda

Japan Aerospace Exploration Agency

View shared research outputs
Top Co-Authors

Avatar

Dan McCammon

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Yoshitaka Ishisaki

Tokyo Metropolitan University

View shared research outputs
Top Co-Authors

Avatar

F. S. Porter

Goddard Space Flight Center

View shared research outputs
Top Co-Authors

Avatar

Joseph S. Adams

Goddard Space Flight Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge