Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Michael A. Acker is active.

Publication


Featured researches published by Michael A. Acker.


The New England Journal of Medicine | 2014

Unexpected Abrupt Increase in Left Ventricular Assist Device Thrombosis

Randall C. Starling; Nader Moazami; Scott C. Silvestry; Gregory A. Ewald; Joseph G. Rogers; Carmelo A. Milano; J. Eduardo Rame; Michael A. Acker; Eugene H. Blackstone; John Ehrlinger; Lucy Thuita; Maria Mountis; Edward G. Soltesz; Bruce W. Lytle; Nicholas G. Smedira

BACKGROUND We observed an apparent increase in the rate of device thrombosis among patients who received the HeartMate II left ventricular assist device, as compared with preapproval clinical-trial results and initial experience. We investigated the occurrence of pump thrombosis and elevated lactate dehydrogenase (LDH) levels, LDH levels presaging thrombosis (and associated hemolysis), and outcomes of different management strategies in a multi-institutional study. METHODS We obtained data from 837 patients at three institutions, where 895 devices were implanted from 2004 through mid-2013; the mean (±SD) age of the patients was 55±14 years. The primary end point was confirmed pump thrombosis. Secondary end points were confirmed and suspected thrombosis, longitudinal LDH levels, and outcomes after pump thrombosis. RESULTS A total of 72 pump thromboses were confirmed in 66 patients; an additional 36 thromboses in unique devices were suspected. Starting in approximately March 2011, the occurrence of confirmed pump thrombosis at 3 months after implantation increased from 2.2% (95% confidence interval [CI], 1.5 to 3.4) to 8.4% (95% CI, 5.0 to 13.9) by January 1, 2013. Before March 1, 2011, the median time from implantation to thrombosis was 18.6 months (95% CI, 0.5 to 52.7), and from March 2011 onward, it was 2.7 months (95% CI, 0.0 to 18.6). The occurrence of elevated LDH levels within 3 months after implantation mirrored that of thrombosis. Thrombosis was presaged by LDH levels that more than doubled, from 540 IU per liter to 1490 IU per liter, within the weeks before diagnosis. Thrombosis was managed by heart transplantation in 11 patients (1 patient died 31 days after transplantation) and by pump replacement in 21, with mortality equivalent to that among patients without thrombosis; among 40 thromboses in 40 patients who did not undergo transplantation or pump replacement, actuarial mortality was 48.2% (95% CI, 31.6 to 65.2) in the ensuing 6 months after pump thrombosis. CONCLUSIONS The rate of pump thrombosis related to the use of the HeartMate II has been increasing at our centers and is associated with substantial morbidity and mortality.


Circulation | 2012

Use of an Intrapericardial, Continuous-Flow, Centrifugal Pump in Patients Awaiting Heart Transplantation

Keith D. Aaronson; Mark S. Slaughter; Leslie W. Miller; Edwin C. McGee; William G. Cotts; Michael A. Acker; Mariell Jessup; Igor D. Gregoric; Pranav Loyalka; O.H. Frazier; Valluvan Jeevanandam; Allen S. Anderson; Robert L. Kormos; Jeffrey J. Teuteberg; Wayne C. Levy; Richard M. Bittman; Francis D. Pagani; David R. Hathaway; Steven W. Boyce

Background— Contemporary ventricular assist device therapy results in a high rate of successful heart transplantation but is associated with bleeding, infections, and other complications. Further reductions in pump size, centrifugal design, and intrapericardial positioning may reduce complications and improve outcomes. Methods and Results— We studied a small, intrapericardially positioned, continuous-flow centrifugal pump in patients requiring an implanted ventricular assist device as a bridge to heart transplantation. The course of investigational pump recipients was compared with that of patients implanted contemporaneously with commercially available devices. The primary outcome, success, was defined as survival on the originally implanted device, transplantation, or explantation for ventricular recovery at 180 days and was evaluated for both noninferiority and superiority. Secondary outcomes included a comparison of survival between groups and functional and quality-of-life outcomes and adverse events in the investigational device group. A total of 140 patients received the investigational pump, and 499 patients received a commercially available pump implanted contemporaneously. Success occurred in 90.7% of investigational pump patients and 90.1% of controls, establishing the noninferiority of the investigational pump (P<0.001; 15% noninferiority margin). At 6 months, median 6-minute walk distance improved by 128.5 m, and both disease-specific and global quality-of-life scores improved significantly. Conclusions— A small, intrapericardially positioned, continuous-flow, centrifugal pump was noninferior to contemporaneously implanted, commercially available ventricular assist devices. Functional capacity and quality of life improved markedly, and the adverse event profile was favorable. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT00751972.


The New England Journal of Medicine | 2014

Mitral-Valve Repair versus Replacement for Severe Ischemic Mitral Regurgitation

Michael A. Acker; Michael K. Parides; Louis P. Perrault; Alan J. Moskowitz; Annetine C. Gelijns; Pierre Voisine; Peter K. Smith; Judy Hung; Eugene H. Blackstone; John D. Puskas; Michael Argenziano; James S. Gammie; Michael J. Mack; Deborah D. Ascheim; Emilia Bagiella; Ellen Moquete; T. Bruce Ferguson; Keith A. Horvath; Nancy L. Geller; Marissa A. Miller; Y. Joseph Woo; David A. D'Alessandro; Gorav Ailawadi; François Dagenais; Timothy J. Gardner; Patrick T. O'Gara; Robert E. Michler; Irving L. Kron

BACKGROUND Ischemic mitral regurgitation is associated with a substantial risk of death. Practice guidelines recommend surgery for patients with a severe form of this condition but acknowledge that the supporting evidence for repair or replacement is limited. METHODS We randomly assigned 251 patients with severe ischemic mitral regurgitation to undergo either mitral-valve repair or chordal-sparing replacement in order to evaluate efficacy and safety. The primary end point was the left ventricular end-systolic volume index (LVESVI) at 12 months, as assessed with the use of a Wilcoxon rank-sum test in which deaths were categorized below the lowest LVESVI rank. RESULTS At 12 months, the mean LVESVI among surviving patients was 54.6±25.0 ml per square meter of body-surface area in the repair group and 60.7±31.5 ml per square meter in the replacement group (mean change from baseline, -6.6 and -6.8 ml per square meter, respectively). The rate of death was 14.3% in the repair group and 17.6% in the replacement group (hazard ratio with repair, 0.79; 95% confidence interval, 0.42 to 1.47; P=0.45 by the log-rank test). There was no significant between-group difference in LVESVI after adjustment for death (z score, 1.33; P=0.18). The rate of moderate or severe recurrence of mitral regurgitation at 12 months was higher in the repair group than in the replacement group (32.6% vs. 2.3%, P<0.001). There were no significant between-group differences in the rate of a composite of major adverse cardiac or cerebrovascular events, in functional status, or in quality of life at 12 months. CONCLUSIONS We observed no significant difference in left ventricular reverse remodeling or survival at 12 months between patients who underwent mitral-valve repair and those who underwent mitral-valve replacement. Replacement provided a more durable correction of mitral regurgitation, but there was no significant between-group difference in clinical outcomes. (Funded by the National Institutes of Health and the Canadian Institutes of Health; ClinicalTrials.gov number, NCT00807040.).


Circulation | 1995

Reverse Remodeling From Cardiomyoplasty in Human Heart Failure External Constraint Versus Active Assist

David A. Kass; Kenneth L. Baughman; Peter H. Pak; Peter W. Cho; Howard R. Levin; Timothy J. Gardner; Henry R. Halperin; Joshua E. Tsitlik; Michael A. Acker

BACKGROUND Cardiomyoplasty (CM) is a novel surgical therapy for dilated cardiomyopathy. In this procedure, the latissimus dorsi muscle is wrapped around the heart and chronically paced synchronously with ventricular systole. While studies have found symptomatic improvement from this therapy, the mechanisms by which CM confers benefit remain uncertain. This study sought to better define these mechanisms by means of serial pressure-volume relation analysis. METHODS AND RESULTS Serial pressure-volume studies were performed by the conductance catheter method in three patients (total to date) with dilated cardiomyopathy (New York Heart Association class III) who underwent CM. Data were measured at baseline (before surgery) and at 6 and 12 months after CM. Chronic left ventricular (LV) systolic and diastolic changes induced by CM were evaluated with the stimulator in its stable pacing mode (every other beat) and after temporarily suspending pacing. CM-stimulated beats were compared with pacing-off beats to evaluate active systolic assist effects of CM. In each patient, CM resulted in a chronic lowering of cardiac end-diastolic volume and an increased ejection fraction. Most notably, the end-systolic pressure-volume relation shifted leftward, consistent with reversal of chronic chamber remodeling. In contrast, the diastolic pressure-volume relation was minimally altered, and the loops shifted down along the same baseline relation. These marked chronic changes in LV function measurable with CM stimulation off contrasted to only minor acute effects observed when the muscle wrap was activated. This suggests that the benefit of CM derived less from active systolic assist than from remodeling, perhaps because of an external elastic constraint. CONCLUSIONS These data, while limited to a small number of patients, suggest that CM can reverse remodeling of the dilated failing heart. While systolic squeezing assist effects of CM may play a role in some patients, our study found that this was not required to achieve substantial benefits from the procedure. We speculate that CM may act more passively, like an elastic girdle around the heart, to help reverse chamber remodeling.


Journal of Heart and Lung Transplantation | 2008

Risk Score Derived from Pre-operative Data Analysis Predicts the Need for Biventricular Mechanical Circulatory Support

J. Raymond Fitzpatrick; John R. Frederick; Vivian M. Hsu; Elliott D. Kozin; Mary Lou O'Hara; Elan Howell; Deborah Dougherty; Ryan C. McCormick; Carine Laporte; Jeffrey E. Cohen; Kevin W. Southerland; Jessica L. Howard; Mariell Jessup; Rohinton J. Morris; Michael A. Acker; Y. Joseph Woo

BACKGROUND Right ventricular (RV) failure after left ventricular assist device (LVAD) placement is a serious complication and is difficult to predict. In the era of destination therapy and the total artificial heart, predicting post-LVAD RV failure requiring mechanical support is extremely important. METHODS We reviewed patient characteristics, laboratory values and hemodynamic data from 266 patients who underwent LVAD placement at the University of Pennsylvania from April 1995 to June 2007. RESULTS Of 266 LVAD recipients, 99 required RV assist device (BiVAD) placement (37%). We compared 36 parameters between LVAD (n = 167) and BiVAD patients (n = 99) to determine pre-operative risk factors for RV assist device (RVAD) need. By univariate analysis, 23 variables showed statistically significant differences between the two groups (p < or = 0.05). By multivariate logistic regression, cardiac index < or =2.2 liters/min/m(2) (odds ratio [OR] 5.7), RV stroke work index < or =0.25 mm Hg . liter/m(2) (OR 5.1), severe pre-operative RV dysfunction (OR 5.0), pre-operative creatinine > or =1.9 mg/dl (OR 4.8), previous cardiac surgery (OR 4.5) and systolic blood pressure < or =96 mm Hg (OR 2.9) were the best predictors of RVAD need. CONCLUSIONS The most significant predictors for RVAD need were cardiac index, RV stroke work index, severe pre-operative RV dysfunction, creatinine, previous cardiac surgery and systolic blood pressure. Using these data, we constructed an algorithm that can predict which LVAD patients will require RVAD with >80% sensitivity and specificity.


Journal of Heart and Lung Transplantation | 2014

Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device

James K. Kirklin; David C. Naftel; Robert L. Kormos; Francis D. Pagani; S.L. Myers; Lynne Warner Stevenson; Michael A. Acker; Daniel L. Goldstein; Scott C. Silvestry; Carmelo A. Milano; J.T. Baldwin; Sean Pinney; J. Eduardo Rame; Marissa A. Miller

BACKGROUND Pump thrombosis remains an uncommon but potentially catastrophic complication of durable continuous-flow left ventricular assist devices (LVAD). A perceived increase in the incidence of pump thrombosis in the HeartMate II (HMII) LVAD (Thoratec, Pleasanton, CA) by clinicians prompted this analysis of the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) database. METHODS Between 2006 and June 2013, 8,988 United States patients aged older than 18 years received a durable LVAD. Of these, 6,910 adult patients from 132 institutions who received a HMII LVAD were entered in the INTERMACS database and constitute the study group for this analysis. RESULTS Overall survival (with censoring at transplant or explant for recovery) with the HMII LVAD was 80% at 1 year and 69% at 2 years and was not significantly different when stratified by era of implant. Freedom from device exchange or death due to thrombosis decreased from 99% at 6 months in 2009 to 94% in 2012 (p < 0.0001). Multivariable hazard function analysis showed risk factors for pump thrombosis included later implant year (p < 0.0001), younger age (p < 0.0001), higher creatinine (p = 0.002), larger body mass index (p = 0.004), white race (p = 0.0004), left ventricular ejection fraction above 20% (p = 0.02), and higher lactate dehydrogenase level at 1 month (p < 0.0001). Survival (p < 0.0001) and freedom from infection (p = 0.008) and cerebrovascular accident (p < 0.0001) were lower after pump exchange than after primary implant. CONCLUSIONS Pump exchange or death due to pump thrombosis increased during 2011 and 2012, but the magnitude of the increase remained relatively small. Survival remains high (80% at 1 year) with the HMII LVAD. Risk factor analysis suggests that a number of patient-related factors contribute to the risk of thrombosis. Markedly elevated lactate dehydrogenase in the first month is a predictor of pump thrombosis. This analysis could not examine the potential role of technical factors during implant, such as sub-optimal pump or graft positioning, changes in patient management paradigms with pump speed settings, improved recognition and change in the threshold for pump exchange, or design or production changes with the pump, as contributors to the risk of pump thrombosis.


The New England Journal of Medicine | 2016

Two-Year Outcomes of Surgical Treatment of Severe Ischemic Mitral Regurgitation

Robert E. Michler; Peter K. Smith; Michael K. Parides; Gorav Ailawadi; Vinod H. Thourani; Alan J. Moskowitz; Michael A. Acker; Judy Hung; Helena L. Chang; Louis P. Perrault; A. Marc Gillinov; Michael Argenziano; Emilia Bagiella; Jessica R. Overbey; Ellen Moquete; Lopa N. Gupta; Marissa A. Miller; Wendy C. Taddei-Peters; Neal Jeffries; Richard D. Weisel; Eric A. Rose; James S. Gammie; Joseph J. DeRose; John D. Puskas; François Dagenais; Sandra G. Burks; Ismail El-Hamamsy; Carmelo A. Milano; Pavan Atluri; Pierre Voisine

BACKGROUND In a trial comparing coronary-artery bypass grafting (CABG) alone with CABG plus mitral-valve repair in patients with moderate ischemic mitral regurgitation, we found no significant difference in the left ventricular end-systolic volume index (LVESVI) or survival after 1 year. Concomitant mitral-valve repair was associated with a reduced prevalence of moderate or severe mitral regurgitation, but patients had more adverse events. We now report 2-year outcomes. METHODS We randomly assigned 301 patients to undergo either CABG alone or the combined procedure. Patients were followed for 2 years for clinical and echocardiographic outcomes. RESULTS At 2 years, the mean (±SD) LVESVI was 41.2±20.0 ml per square meter of body-surface area in the CABG-alone group and 43.2±20.6 ml per square meter in the combined-procedure group (mean improvement over baseline, -14.1 ml per square meter and -14.6 ml per square meter, respectively). The rate of death was 10.6% in the CABG-alone group and 10.0% in the combined-procedure group (hazard ratio in the combined-procedure group, 0.90; 95% confidence interval, 0.45 to 1.83; P=0.78). There was no significant between-group difference in the rank-based assessment of the LVESVI (including death) at 2 years (z score, 0.38; P=0.71). The 2-year rate of moderate or severe residual mitral regurgitation was higher in the CABG-alone group than in the combined-procedure group (32.3% vs. 11.2%, P<0.001). Overall rates of hospital readmission and serious adverse events were similar in the two groups, but neurologic events and supraventricular arrhythmias remained more frequent in the combined-procedure group. CONCLUSIONS In patients with moderate ischemic mitral regurgitation undergoing CABG, the addition of mitral-valve repair did not lead to significant differences in left ventricular reverse remodeling at 2 years. Mitral-valve repair provided a more durable correction of mitral regurgitation but did not significantly improve survival or reduce overall adverse events or readmissions and was associated with an early hazard of increased neurologic events and supraventricular arrhythmias. (Funded by the National Institutes of Health and Canadian Institutes of Health Research; ClinicalTrials.gov number, NCT00806988.).


The Journal of Thoracic and Cardiovascular Surgery | 2009

Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device

J. Raymond Fitzpatrick; John R. Frederick; William Hiesinger; Vivian M. Hsu; Ryan C. McCormick; Elliott D. Kozin; Carine M. Laporte; Mary Lou O'Hara; Elan Howell; Deborah Dougherty; Jeffrey E. Cohen; Kevin W. Southerland; Jessica L. Howard; E. Carter Paulson; Michael A. Acker; Rohinton J. Morris; Y. Joseph Woo

OBJECTIVE It is generally accepted that patients who require biventricular assist device support have poorer outcomes than those requiring isolated left ventricular assist device support. However, it is unknown how the timing of biventricular assist device insertion affects outcomes. We hypothesized that planned biventricular assist device insertion improves survival compared with delayed conversion of left ventricular assist device support to biventricular assist device support. METHODS We reviewed and compared outcomes of 266 patients undergoing left ventricular assist device or biventricular assist device placement at the University of Pennsylvania from April 1995 to June 2007. We subdivided patients receiving biventricular assist devices into planned biventricular assist device (P-BiVAD) and delayed biventricular assist device (D-BiVAD) groups based on the timing of right ventricular assist device insertion. We defined the D-BiVAD group as any failure of isolated left ventricular assist device support. RESULTS Of 266 patients who received left ventricular assist devices, 99 (37%) required biventricular assist device support. We compared preoperative characteristics, successful bridging to transplantation, survival to hospital discharge, and Kaplan-Meier 1-year survival between the P-BiVAD (n = 71) and D-BiVAD (n = 28) groups. Preoperative comparison showed that patients who ultimately require biventricular support have similar preoperative status. Left ventricular assist device (n = 167) outcomes in all categories exceeded both P-BiVAD and D-BiVAD group outcomes. Furthermore, patients in the P-BiVAD group had superior survival to discharge than patients in the D-BiVAD group (51% vs 29%, P < .05). One-year and long-term Kaplan-Meier survival distribution confirmed this finding. There was also a trend toward improved bridging to transplantation in the P-BiVAD (n = 55) versus D-BiVAD (n = 22) groups (65% vs 45%, P = .10). CONCLUSION When patients at high risk for failure of isolated left ventricular assist device support are identified, proceeding directly to biventricular assist device implantation is advised because early institution of biventricular support results in dramatic improvement in survival.


Journal of Heart and Lung Transplantation | 2013

HeartWare ventricular assist system for bridge to transplant: Combined results of the bridge to transplant and continued access protocol trial

Mark S. Slaughter; Francis D. Pagani; Edwin C. McGee; Emma J. Birks; William G. Cotts; Igor D. Gregoric; O. Howard Frazier; T.B. Icenogle; Samer S. Najjar; Steven W. Boyce; Michael A. Acker; Ranjit John; David R. Hathaway; Kevin B. Najarian; Keith D. Aaronson

BACKGROUND The HeartWare Ventricular Assist System (HeartWare Inc, Framingmam, MA) is a miniaturized implantable, centrifugal design, continuous-flow blood pump. The pivotal bridge to transplant and continued access protocols trials have enrolled patients with advanced heart failure in a bridge-to-transplant indication. METHODS The primary outcome, success, was defined as survival on the originally implanted device, transplant, or explant for ventricular recovery at 180 days. Secondary outcomes included an evaluation of survival, functional and quality of life outcomes, and adverse events. RESULTS A total of 332 patients in the pivotal bridge to transplant and continued access protocols trial have completed their 180-day primary end-point assessment. Survival in patients receiving the HeartWare pump was 91% at 180 days and 84% at 360 days. Quality of life scores improved significantly, and adverse event rates remain low. CONCLUSIONS The use of the HeartWare pump as a bridge to transplant continues to demonstrate a high 180-day survival rate despite a low rate of transplant. Adverse event rates are similar or better than those observed in historical bridge-to-transplant trials, despite longer exposure times due to longer survival and lower transplant rates.


Journal of the American College of Cardiology | 2015

Randomized Comparison of Percutaneous Repair and Surgery for Mitral Regurgitation: 5-Year Results of EVEREST II.

Ted Feldman; Saibal Kar; Sammy Elmariah; Steven C. Smart; Alfredo Trento; Robert J. Siegel; Patricia Apruzzese; Peter S. Fail; Michael J. Rinaldi; Richard W. Smalling; James B. Hermiller; David A. Heimansohn; William A. Gray; Paul A. Grayburn; Michael J. Mack; D. Scott Lim; Gorav Ailawadi; Howard C. Herrmann; Michael A. Acker; Frank E. Silvestry; Elyse Foster; Andrew Wang; Donald D. Glower; Laura Mauri

BACKGROUND In EVEREST II (Endovascular Valve Edge-to-Edge Repair Study), treatment of mitral regurgitation (MR) with a novel percutaneous device showed superior safety compared with surgery, but less effective reduction in MR at 1 year. OBJECTIVES This study sought to evaluate the final 5-year clinical outcomes and durability of percutaneous mitral valve (MV) repair with the MitraClip device compared with conventional MV surgery. METHODS Patients with grade 3+ or 4+ MR were randomly assigned to percutaneous repair with the device or conventional MV surgery in a 2:1 ratio (178:80). Patients prospectively consented to 5 years of follow-up. RESULTS At 5 years, the rate of the composite endpoint of freedom from death, surgery, or 3+ or 4+ MR in the as-treated population was 44.2% versus 64.3% in the percutaneous repair and surgical groups, respectively (p = 0.01). The difference was driven by increased rates of 3+ to 4+ MR (12.3% vs. 1.8%; p = 0.02) and surgery (27.9% vs. 8.9%; p = 0.003) with percutaneous repair. After percutaneous repair, 78% of surgeries occurred within the first 6 months. Beyond 6 months, rates of surgery and moderate-to-severe MR were comparable between groups. Five-year mortality rates were 20.8% and 26.8% (p = 0.4) for percutaneous repair and surgery, respectively. In multivariable analysis, treatment strategy was not associated with survival. CONCLUSIONS Patients treated with percutaneous repair more commonly required surgery for residual MR during the first year after treatment, but between 1- and 5-year follow-up, comparably low rates of surgery for MV dysfunction with either percutaneous or surgical therapy endorse the durability of MR reduction with both repair techniques. (EVEREST II Pivotal Study High Risk Registry; NCT00209274).

Collaboration


Dive into the Michael A. Acker's collaboration.

Top Co-Authors

Avatar

Pavan Atluri

University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Mariell Jessup

University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Ann C. Gaffey

University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Joseph E. Bavaria

University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Jessica L. Howard

University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Robert C. Gorman

University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Joseph H. Gorman

University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

Lee R. Goldberg

University of Pennsylvania

View shared research outputs
Top Co-Authors

Avatar

James J. Pilla

University of Pennsylvania

View shared research outputs
Researchain Logo
Decentralizing Knowledge